QS18EP6LP [BANNER]
WORLD-BEAM® QS18E Series;型号: | QS18EP6LP |
厂家: | Banner Engineering |
描述: | WORLD-BEAM® QS18E Series |
文件: | 总11页 (文件大小:860K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
®
WORLD-BEAM QS18E Series
Datasheet
•
Easy-to-use Expert-style Staꢀc and Dynamic TEACH opꢀons, plus Window, Light, and Dark
SET, via push buꢁon or remote input
•
•
Smart power-control algorithm to maximize performance in low-contrast applicaꢀons
Easy push-buꢁon or remote sensor setup opꢀons:
◦
◦
Dark-Operate/Light-Operate select
Selectable 30 ms output OFF-delay
•
•
•
•
•
•
Less than 1 millisecond output response for excellent sensing repeatability
Tough ABS housing is rated IEC IP67; NEMA 6
Bright LED operaꢀng status indicators are visible from 360°
Discrete PNP or NPN output, depending on model
Mulꢀple connecꢀon opꢀons available (see Models)
Compact housing, easy barrel-mount (some models) or side-mount installaꢀon
WARNING: Not To Be Used for Personnel Protecꢀon
Never use this device as a sensing device for personnel protecꢀon. Doing so could lead to serious injury or death. This device
does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applicaꢀons. A sensor failure
or malfuncꢀon can cause either an energized or de-energized sensor output condiꢀon.
Model
Sensing Mode
Range
Output
Model
Sensing Mode
Range
Output
QS18EN6LP
660 nm Visible Red
NPN
QS18EN6CV15
660 nm Visible Red
NPN
3.5 m (12 ꢂ)
16 mm (0.65
in)
1
P
QS18EP6LP
PNP
QS18EP6CV15
PNP
POLAR RETRO
CONVERGENT
QS18EN6D
QS18EP6D
QS18EN6DB
NPN
PNP
NPN
QS18EN6CV45
QS18EP6CV45
QS18EN6FP
NPN
PNP
NPN
800 mm (31.5
in)
43 mm (1.7
in)
660 nm Visible Red
Varies by
mode and
fiber opꢀcs
used
940 nm Infrared
500 mm (19.7
in)
QS18EP6DB
QS18EN6W
QS18EP6W
PNP
NPN
PNP
QS18EP6FP
QS18EN6DV
QS18EP6DV
PNP
NPN
PNP
PLASTIC FIBER
DIFFUSE
660 nm Visible Red
300 mm (11.8
in)
600 mm
(23.6 in)
DIFFUSE
The standard 2 m (6.5 ꢂ) cable models are listed. To order the 9 m (30 ꢂ) cable models, add the suffix "W/30" to the cabled model number. For example, QS18EN6FP W/30. Models with a
quick disconnect (QD) connector require a maꢀng cable.
To order a model with a 4-pin QD 150 mm (6 in) Euro-style pigtail, add suffix “Q5” (for example, QS18EN6FPQ5).
To order a model with a 4-pin 150 mm (6 in) Pico-style pigtail, add suffix “Q” (for example, QS18EN6FPQ).
To order a model with a 4-pin Integral Euro-style QD, add suffix “Q8” (for example, QS18EN6FPQ8).
To order a model with a 4-pin Integral Pico-style QD, add suffix “Q7” (for example, QS18EN6FPQ7).
1
Specified using BRT-84 reflector (sold separately)
Original Document
136564 Rev. E
14 March 2017
136564
®
WORLD-BEAM QS18E Series
Overview of QS18E Expert Series Sensors
The QS18E Expert Sensors family of sensors provides high-performance sensing in a compact package.
The sensors feature a discrete output (NPN or PNP, depending on model), two bright LEDs for easy
status monitoring during configuraꢀon and operaꢀon, mulꢀple configuraꢀon opꢀons, remote
configuraꢀon, and security lockout opꢀons.
1
2
1. Amber output LED
2. Green power indicator LED
3. Receiver port
4. Emiꢁer port
5. Configuraꢀon buꢁon
3
Indicators (Two LEDs: One Green, One Amber)
Sensor Condiꢀon (Run Mode)
Output OFF
Green LED
ON
Amber LED
OFF
4
Output ON
ON
ON
Output ON, marginal signal
Output Short Circuit
ON
Flashing
OFF
Flashing
5
Figure 1. Sensor features
Wiring Diagrams
NPN (Sinking) Outputs
PNP (Sourcing) Outputs
10–30 V dc
10-30V dc
Load
Load
Remote
Remote
Programming
(N.O.)
Programming
(N.O.)
Cabled wiring diagrams are shown. Quick disconnect (QD) wiring diagrams are funcꢀonally idenꢀcal.
2
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 136564 Rev. E
®
WORLD-BEAM QS18E Series
Sensor Conꢁguraꢀon
Configure the sensor using any of five TEACH or Set opꢀons (by push buꢁon or the remote wire) to
define the sensing limits. Use a Setup procedure to enable a 30 ms OFF-delay or to change the Light-/
Dark-Operate seꢃng (see Sensor Setup on page 3). Sensing limit configuraꢀon opꢀons include:
•
•
Staꢀc TEACH: one switching threshold, determined by two taught condiꢀons
Dynamic (on-the-fly) TEACH: one switching threshold, determined by mulꢀple sampled
condiꢀons
•
•
Light Set and Dark Set: one switching threshold, offset from a single sensing condiꢀon (the
“dark” condiꢀon or the “light” condiꢀon; see Figure)
Window Set: a sensing window, centered around a single sensing condiꢀon
The sensor’s output is disabled during all TEACH and Set procedures, and is enabled upon return to Run
mode.
Following any TEACH or Set procedure other than Staꢀc TEACH, the Output ON condiꢀon (Light- or
Dark-Operate seꢃng) remains as it was last configured. To change that seꢃng or the OFF-delay seꢃng,
see Sensor Setup on page 3.
Figure 2. Dark Sensing Condiꢀon
Remote Conꢁguraꢀon
Use the remote funcꢀon to configure the sensor remotely or to disable the push buꢁon for security. Connect the white wire of the sensor to ground (0V
dc), through a remote programming switch. Pulse the remote line according to the diagrams in the configuraꢀon procedures. The length of the individual
programming pulses is equal to the value T: 0.04 seconds ≤ T ≤ 0.8 seconds
Push Buꢂon Enable/Disable
The remote input may be used to disable the sensor push buꢁon to prevent unauthorized adjustment. Connect the white wire of the sensor as described
above to perform the procedure below to either enable or disable the feature.
Push Buꢂon Enable/Disable
Push Buꢂon ( 0.04 seconds ≤ "Click" ≤
Remote Line ( 0.04 seconds ≤ T ≤ 0.8 seconds)
Result
0.8 seconds)
Not available
From Run mode, four-pulse the remote line.
Sensor toggles between enable/disable seꢃngs and returns to RUN
mode.
T
T
T
T
Power LED: Flashes 3x, then ON Green
2
Output LED: OFF, then ON or OFF, depending on output state
T
T
T
Returning to RUN Mode without Saving Seꢃngs
Exit Staꢀc TEACH and Set modes aꢂer the automaꢀc 60-second ꢀme-out or by manually exiꢀng the process. To manual exit, press and hold the push
buꢁon (or hold the remote line low) for 2 seconds. The sensor returns to Run mode without saving any new seꢃngs.
Sensor Setup
Access setup funcꢀons directly from Run mode using the following procedures.
30 ms OFF-Delay (Pulse Stretcher) Enable/Disable
Push Buꢂon (0.04 seconds ≤ “Click” ≤ 0.8
seconds)
Remote Line (0.04 seconds ≤ T ≤ 0.8 seconds)
Results
From Run mode, six-click the push buꢁon. From Run mode, six-pulse remote line.
Sensor toggles between enable/disable seꢃngs and
returns to Run mode.
T
T
T
T
T
T
Power LED: Flashes 3x, then ON Green
3
Output LED: Enabled – ON,
Disabled – OFF,
T
T
T
T
T
3
Then ON or OFF, depending on output state
2
3
Iniꢀal output LED condiꢀon is simultaneous with Power LED 3-flash
Iniꢀal Output LED condiꢀon is simultaneous with Power LED 3-flash.
P/N 136564 Rev. E
www.bannerengineering.com - Tel: +1-763-544-3164
3
®
WORLD-BEAM QS18E Series
Light-Operate/Dark-Operate Select
Push Buꢂon (0.04 seconds ≤ “Click” ≤ 0.8
seconds)
Remote Line (0.04 seconds ≤ T ≤ 0.8 seconds)
Results
From Run mode, seven-click the push
buꢁon.
From Run mode, seven-pulse remote line.
Sensor toggles between Light-/Dark-Operate seꢃngs
and returns to Run mode.
T
T
T
T
T
T
T
Power LED: Flashes 3x, then ON Green
3
Output LED: Light Operate – ON,
Dark Operate – OFF,
T
T
T
T
T
T
3
Then ON or OFF, depending on output state
Staꢀc TEACH
•
Staꢀc TEACH locates a single switching threshold (switchpoint) at
the opꢀmal locaꢀon between the two taught condiꢀons, with the
Output ON condiꢀon on one side, and the Output OFF condiꢀon
on the other.
2nd Taught
Condition
1st Taught
Condition
Sensor positions
threshold between
presented conditions
•
•
During Staꢀc TEACH, the first condiꢀon taught is the ON
condiꢀon. Output ON and OFF condiꢀons may be reversed by
switching the TEACH order or by changing the Light-/Dark-
Operate seꢃng in setup mode (see Sensor Setup on page 3).
Staꢀc TEACH is recommended for applicaꢀons where two
condiꢀons can be presented individually.
Output OFF
Output ON
Darkest
(no signal)
Most Light
(saturated
signal)
Figure 3. Staꢀc TEACH (Light Operate shown)
1. Access the Staꢀc TEACH Mode.
Method
Acꢀon
Result
The sensor waits for the first sensing condiꢀon.
Push Buꢂon
Remote Line
Press and hold the push buꢁon 2 to 4 seconds.
Power LED Indicator: OFF
Output LED Indicator: Slow flash (1Hz)
No acꢀon required; the sensor is ready for the first sensing condiꢀon.
2. Teach the first sensing condiꢀon.
Method
Acꢀon
Result
Present the first (ON) sensing condiꢀon, then click the
push buꢁon.
Push Buꢂon
Power LED Indicator: OFF
Output LED Indicator: Double-flash
T
Present the first sensing condiꢀon, then single-pulse the
remote line.
Remote Line
3. Teach the second sensing condiꢀon.
Method
Acꢀon
Result
TEACH Accepted
Present the second (OFF) sensing condiꢀon, then click the
push buꢁon.
Push Buꢂon
Power LED Indicator: Flashes 3 ꢀmes, then
solid green
Output LED Indicator: OFF
The sensor returns to Run mode with the new
seꢃngs.
TEACH Not Accepted
Power LED Indicator: OFF
Output LED Indicator: Slow flash (1 Hz)
T
Present the second sensing condiꢀon, then single-pulse
the remote line.
Remote Line
The sensor returns to the wait state, ready for
the first sensing condiꢀon.
4
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 136564 Rev. E
®
WORLD-BEAM QS18E Series
Dynamic TEACH
•
•
Dynamic TEACH sets a single switching threshold (switchpoint).
Darkest Presented
Condition
Lightest Presented
Condition
Dynamic TEACH is used to teach during actual sensing condiꢀons,
taking mulꢀple samples of the light and dark condiꢀons and
automaꢀcally seꢃng the threshold at the opꢀmum level.
The Output ON state (Light- or Dark-Operate seꢃng) remains as it
was last configured. To change the Light-/Dark-Operate seꢃng,
see Sensor Setup on page 3.
Sensor positions
threshold between
•
•
presented conditions
Dynamic TEACH is recommended for applicaꢀons where a
machine or process may not be stopped for teaching.
Output OFF
Output ON
Darkest
(no signal)
Most Light
(saturated
signal)
Figure 4. Dynamic TEACH (Light Operate shown)
1. Access the Dynamic TEACH mode.
Method
Acꢀon
Result
Push Buꢂon
Press and hold the push buꢁon for longer than 4 seconds.
Power LED Indicator: OFF
Output LED Indicator: Quick flash (2 Hz)
Hold the remote line low (to ground) for longer than 2
seconds.
2 seconds
Remote Line
2. Teach the sensing condiꢀon.
Method
Acꢀon
Result
Conꢀnue to hold the push buꢁon and present the Output
ON and OFF condiꢀons mulꢀple ꢀmes.
Push Buꢂon
Power LED Indicator: OFF
Output LED Indicator: Quick flash (2 Hz)
Conꢀnue to hold the remote line low (to ground) and
present the Output ON and OFF condiꢀons mulꢀple
ꢀmes.
Remote Line
3. Return to Run mode.
Method
Acꢀon
Result
TEACH Accepted
Push Buꢂon
Release the push buꢁon.
Power LED Indicator: Flashes 3 ꢀmes, then
solid green
4
Output LED Indicator: OFF , then ON or OFF
depending on the output state
The sensor returns to Run mode with the new
seꢃngs.
TEACH Not Accepted
Remote Line
Release the remote line/switch.
Power LED Indicator: Flashes 3 ꢀmes, then
solid green
4
Output LED Indicator: ON , then ON or OFF
depending on the output state
The sensor returns to Run mode without
changing seꢃngs.
4
The iniꢀal output LED indicator condiꢀon is simultaneous with the power LED indicator 3-flash
P/N 136564 Rev. E
www.bannerengineering.com - Tel: +1-763-544-3164
5
®
WORLD-BEAM QS18E Series
Light Set
•
•
•
Light Set sets a threshold approximately 12.5% below the
presented sensing condiꢀon.
Any condiꢀon darker than the threshold causes the output to
change state.
In Light-Operate mode, the presented condiꢀon is the Output ON
condiꢀon. In Dark-Operate mode, the presented condiꢀon is the
Output OFF condiꢀon. To change the Light-/Dark-Operate seꢃng,
see Sensor Setup on page 3.
Sensor positions
threshold ≈12.5% below
the presented condition
Output OFF
Output ON
•
Light Set is recommended for applicaꢀons where only one
condiꢀon is known, for example a stable light background with
varying darker targets, or in retroreflecꢀve applicaꢀons.
Darkest
(no signal)
Single
Presented
Condition
Most Light
(saturated
signal)
Figure 5. Light Set (Light Operate shown)
1. Access the Light Set mode.
Method
Acꢀon
Result
The sensor waits for the sensing condiꢀon.
Push Buꢂon
Press and hold the push buꢁon 2 to 4 seconds.
Power LED Indicator: OFF
Output LED Indicator: Slow flash (1 Hz)
The sensor waits for the sensing condiꢀon.
T
Remote Line
Single-pulse the remote line.
Power LED Indicator: OFF
Output LED Indicator: Double-flash
2. Set the sensing condiꢀon.
Method
Acꢀon
Result
TEACH Accepted
Present the sensing condiꢀon, then four-click the push
buꢁon.
Push Buꢂon
Power LED Indicator: Flashes 3 ꢀmes, then
solid green
5
Output LED Indicator: OFF , then ON or OFF,
depending on the output state
The sensor returns to Run mode with the new
seꢃngs.
Present the sensing condiꢀon, then four-pulse the remote line.
T
T
T
T
TEACH Not Accepted
Power LED Indicator: OFF
Output LED Indicator: Slow flash (1 Hz)
Remote Line
T
T
T
The sensor returns to the wait state, ready for
the sensing condiꢀon.
Dark Set
•
Dark Set sets a threshold approximately 12.5% above the
presented sensing condiꢀon.
Sensor positions
threshold ≈12.5% above
the presented condition
•
•
Any condiꢀon lighter than the threshold causes the output to
change state.
In Light-Operate mode, the presented condiꢀon is the Output OFF
condiꢀon. In Dark-Operate mode, the presented condiꢀon is the
Output ON condiꢀon. To change the Light-/Dark-Operate seꢃng,
see Sensor Setup on page 3.
Output OFF
Output ON
•
Dark Set is recommended for applicaꢀons where only one
condiꢀon is known, for example a stable dark background with
varying lighter targets, or when maximum excess gain is required.
Single
Presented
Condition
Darkest
(no signal)
Most Light
(saturated
signal)
Figure 6. Dark Set (Light Operate shown)
1. Access the Dark Set mode.
Method
Acꢀon
Result
The sensor waits for the sensing condiꢀon.
Push Buꢂon
Press and hold the push buꢁon 2 to 4 seconds.
Power LED Indicator: OFF
Output LED Indicator: Slow flash (1 Hz)
5
The iniꢀal output LED indicator condiꢀon is simultaneous with the power LED indicator 3-flash.
6
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 136564 Rev. E
®
WORLD-BEAM QS18E Series
Method
Acꢀon
Result
The sensor waits for the sensing condiꢀon.
T
Remote Line
Single-pulse the remote line.
Power LED Indicator: OFF
Output LED Indicator: Double-flash
2. Set the sensing condiꢀon.
Method
Acꢀon
Result
TEACH Accepted
Present the sensing condiꢀon, then five-click the push
buꢁon.
Push Buꢂon
Power LED Indicator: Flashes 3 ꢀmes, then
solid green
6
Output LED Indicator: OFF , then ON or OFF,
depending on the output state
Present the sensing condiꢀon, then five-pulse the remote line.
The sensor returns to Run mode with the new
seꢃngs.
TEACH Not Accepted
Power LED Indicator: OFF
Output LED Indicator: Slow flash (1 Hz)
T
T
T
T
T
Remote Line
T
T
T
T
The sensor returns to the wait state, ready for
the sensing condiꢀon.
Window Set
•
In Window Set, the single ON condiꢀon window extends
approximately 12.5% above and below the presented condiꢀon
when Light Operate is selected. Output ON and OFF condiꢀons
may be reversed by changing the Light-/Dark-Operate seꢃng (see
Sensor Setup on page 3).
12.5%
Sensor positions
window thresholds
≈12.5% from the
presented condition
•
•
Lighter or darker condiꢀons outside of the window cause the
output to change state.
Output
ON
Window Set is recommended for applicaꢀons where the target to
be sensed may not always appear in the same place, or when
other unwanted signals may appear.
Output OFF
Output OFF
Darkest
(no signal)
Single
Presented
Condition
Most Light
(saturated
signal)
Figure 7. Window Set (Light Operate shown)
1. Access the Window Set mode.
Method
Acꢀon
Result
The sensor waits for the sensing condiꢀon.
Push Buꢂon
Press and hold the push buꢁon 2 to 4 seconds.
Power LED Indicator: OFF
Output LED Indicator: Slow flash (1 Hz)
The sensor waits for the sensing condiꢀon.
T
Remote Line
Single-pulse the remote line.
Power LED Indicator: OFF
Output LED Indicator: Double-flash
2. Set the sensing condiꢀon.
Method
Acꢀon
Result
TEACH Accepted
Present the sensing condiꢀon, then double-click the push
buꢁon.
Push Buꢂon
Power LED Indicator: Flashes 3 ꢀmes, then
solid green
7
Output LED Indicator: OFF , then ON or OFF,
depending on the output state
The sensor returns to Run mode with the new
seꢃngs.
T
T
Present the sensing condiꢀon, then double-pulse the
remote line.
TEACH Not Accepted
Remote Line
Power LED Indicator: OFF
Output LED Indicator: Slow flash (1 Hz)
T
The sensor returns to the wait state, ready for
the sensing condiꢀon.
6
7
The iniꢀal output LED indicator condiꢀon is simultaneous with the power LED indicator 3-flash.
The iniꢀal output LED indicator condiꢀon is simultaneous with the power LED indicator 3-flash.
P/N 136564 Rev. E
www.bannerengineering.com - Tel: +1-763-544-3164
7
®
WORLD-BEAM QS18E Series
Speciꢁcaꢀons
Supply Voltage
Output Protecꢀon Circuitry
10 to 30 V dc (10% maximum ripple) at less than 35 mA, exclusive of load; 10 to 24 V dc
at > 55º C
Protected against false pulse on power-up and conꢀnuous overload or short-circuit of
output
Supply Protecꢀon Circuitry
Output Response
Protected against reverse polarity and transient voltages
Note: Momentary delay on power-up; output does not conduct during this ꢀme
600 µs ON/OFF
Output Conꢁguraꢀon
Repeatability
Current sourcing (PNP) or current sinking (NPN), depending on model; Light- or dark-
operate selectable; Selectable 30 ms output OFF-delay
75 µs
Raꢀng: 100 mA max
Construcꢀon
Off-state leakage current: less than 50 µA at 30 V dc (see Applicaꢀon Note 1)
ON-state saturaꢀon voltage: less than 1.5 V at 100 mA (1.7V for 30 ꢂ cable models)
ABS housing, PMMA lens
Connecꢀons
PVC-jacketed 4-conductor 2 m (6.5 ꢂ) or 9 m (30 ꢂ) unterminated cable, or 4-pin Euro-
style or 4-pin Pico-style quick-disconnect (QD), either integral or 150 mm (6 in) pigtail,
are available. QD cordsets are ordered separately.
Operaꢀng Condiꢀons
Required Overcurrent Protecꢀon
Temperature: −20 °C to +70 °C (−4 °F to +158 °F)
Relaꢀve Humidity: 95% at +50 °C maximum relaꢀve humidity (non-condensing)
WARNING: Electrical connecꢀons must be made by
qualified personnel in accordance with local and
naꢀonal electrical codes and regulaꢀons.
Applicaꢀon Notes
If the push buꢁon does not appear to be responsive, perform the push buꢁon enable
procedure
Overcurrent protecꢀon is required to be provided by end product applicaꢀon per the
supplied table.
To maintain backwards compaꢀbility with earlier models, 3 remote line pulses or a push
buꢁon hold followed by 3 push buꢁon clicks will perform a Dark SET.
Overcurrent protecꢀon may be provided with external fusing or via Current Limiꢀng,
Class 2 Power Supply.
Cerꢀꢁcaꢀons
Supply wiring leads < 24 AWG shall not be spliced.
For addiꢀonal product support, go to www.bannerengineering.com.
Supply Wiring (AWG)
Required Overcurrent Protecꢀon (Amps)
20
22
24
26
28
30
5.0
3.0
2.0
1.0
0.8
0.5
Dimensions
Model Suffix E, EV, R, FF
Model Suffix EB, RB
Model Suffix DB, W
Model Suffix FP
31.0 mm
(1.22")
27.5 mm
(1.09")
21.1 mm
(0.82")
21.1 mm
(0.82")
15.0 mm
(0.59")
17.1 mm
Yellow
LED
Green
LED
17.1 mm
(0.67")
(0.67")
15.0 mm
(0.59")
3.0 mm
(0.12")
3.0 mm
(0.12")
7.5 mm
(0.30")
3.0 mm
(0.12")
13.4 mm
(0.53")
24.1 mm
(0.95")
35.0 mm
(1.38")
5.2 mm
(0.21")
7.6 mm
(0.30")
Ø3.3 mm (0.13")
Max. torque 0.9 Nm (8 lbf. in)
QS18...FP Fiber InstallationA
C
Model Suffix F
Model Suffix CV15, CV45, D, DL, LV, LP
31.0 mm†
36.9 mm
(1.45")
A.Slide the fiber clip to open.
Single-turn
(1.22")
Sensitivity
B.Insert fiber ends into each port,
as far as they will go.
C.Slide the fiber clip closed,
locking fibers into position.
3.0 mm
17.1 mm
(0.67")
19.8 mm
(0.78")
Adjustment
(0.12")
B
*Model Suffix Q
(e.g. QS186EQ)
*Model Suffix Q5
(e.g. QS186EQ5)
*Model Suffix Q7
(e.g. QS186EQ7)
*Model Suffix Q8
(e.g. QS186EQ8)
M18x1 Thread
Max. torque 2.3 Nm (20 lbf. in)
Slot for
Fiber Clip
† CV Models:
33.2 mm (1.31")
M18 x 1 Jam Nut
41.5 mm
(1.63")
49 mm
(1.93")
M3 Hardware Packet Contents:
2 – M3 x 0.5 x 20 mm SS screw
2 – M3 x 0.5 SS hex nut
24.2 mm(0.95")
Packing List
Sensor
M18 x 1 jam nut
M3 hardware packet
Installation sheet P/N 63687
150 mm (6")
Euro-style
Pigtail
2 – M3 SS washer
8.0 mm(0.32")
Integral
4-pin
Pico-Style QD
Integral
4-pin
Euro-Style QD
150 mm (6")
Pico-style
Pigtail
All measurements are listed in millimeters [inches], unless noted otherwise.
8
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 136564 Rev. E
®
WORLD-BEAM QS18E Series
Performance Curves
Performance using Dark Set, performed in no-light condiꢀon.
Polarized Retroreꢄecꢀve
Excess Gain
Beam Paꢂern
Diffuse (Based on use of 90% reꢄectance white test card.)
Excess Gain
Beam Paꢂern
Excess Gain
Beam Paꢂern
Convergent
Excess Gain
Beam Paꢂern
Excess Gain
Beam Paꢂern
Fiber Opꢀc - Plasꢀc
Excess Gain
Beam Paꢂern
Excess Gain
Beam Paꢂern
P/N 136564 Rev. E
www.bannerengineering.com - Tel: +1-763-544-3164
9
®
WORLD-BEAM QS18E Series
Accessories
4-Pin Snap-on M8/Pico-Style Cordsets
Model
Length
Style
Dimensions
Pinout (Female)
32 Typ.
PKG4-2
2 m (6.56 ꢂ)
Straight
ø 9.0
4
2
1
3
29 Typ.
1 = Brown
2 = White
3 = Blue
PKW4Z-2
2 m (6.56 ꢂ)
Right-Angle
15 Typ.
4 = Black
ø 10.9
4-Pin Threaded M12/Euro-Style Cordsets
Model
Length
Style
Dimensions
Pinout (Female)
MQDC-406
MQDC-415
MQDC-430
1.83 m (6 ꢂ)
4.57 m (15 ꢂ)
9.14 m (30 ꢂ)
44 Typ.
Straight
M12 x 1
ø 14.5
2
MQDC-450
15.2 m (50 ꢂ)
1
4
3
MQDC-406RA
MQDC-415RA
MQDC-430RA
1.83 m (6 ꢂ)
4.57 m (15 ꢂ)
9.14 m (30 ꢂ)
32 Typ.
[1.26"]
1 = Brown
2 = White
3 = Blue
30 Typ.
[1.18"]
Right-Angle
4 = Black
MQDC-450RA
15.2 m (50 ꢂ)
M12 x 1
ø 14.5 [0.57"]
SMB312S
SMBQS18DIN
B
C
•
Right-angle bracket
assembly for mounꢀng on
35 mm DIN rail
•
Stainless steel 2-axis, side-
mount bracket
46
•
300 series stainless steel
and glass filled nylon; zinc-
plated screws
A
32
20
A = 4.3 × 7.5, B = diam. 3, C = 3 × 15.3
10
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 136564 Rev. E
®
WORLD-BEAM QS18E Series
2x
8
SMBQS18Y
SMB18A
30
3.4 mm
[0.13"]
•
•
•
Die-cast bracket for 18 mm
15.5 mm
[0.61"]
•
Right-angle mounꢀng
bracket with a curved slot
for versaꢀle orientaꢀon
holes
4.5 mm
[0.18"]
7.8 mm
[0.31"]
C
41
Includes metal hex nut and
lock washer
Allows ± 8° for cabled
sensors
A
B
•
•
12-ga. stainless steel
2x R24.1 mm
[0.95"]
24.1 mm
[0.94"]
18 mm sensor mounꢀng
38.0 mm
[1.50"]
hole
46
•
Clearance for M4 (#8)
hardware
Hole size: A = ø 15.3
12.0 mm
[0.47"]
25.4 mm
[1"]
Hole center spacing: A to B = 24.2
Hole size: A = ø 4.6, B = 17.0 × 4.6, C = ø 18.5
16.4 mm
[0.65"]
9.8 mm
[0.38"]
19.5 mm
[0.77"]
14.5 mm
[0.57"]
SMB4050YL
SMB3018SC
67
•
•
•
•
Heavy-duty die-cast bracket
•
•
•
18 mm swivel side or barrel-
for industrial protecꢀon
mount bracket
B
Replaceable window for use
with some sensor models
M18 verꢀcal mounꢀng
opꢀon
Nut and lock washer
included
Black reinforced
thermoplasꢀc polyester
Stainless steel swivel locking
hardware included
59
29
A
A = ø 15.3
Hole center spacing: A = 50.8
Hole size: A = ø 7.0, B = ø 18.0
Addiꢀonal available brackets: SMB46A, SMB18SF, SMBQS18RA, SMB18FA, SMBQS18A
For a list of reflectors or fiber opꢀc assemblies, refer to the Accessories secꢀon of your current Banner Sensors catalog or visit
www.bannerengineering.com for complete informaꢀon.
Banner Engineering Corp. Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any
product of its manufacture which, at the ꢀme it is returned to the factory, is found to have been defecꢀve during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the
improper applicaꢀon or installaꢀon of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discreꢀon of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR
ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO
USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligaꢀons or liabiliꢀes relaꢀng to any product previously manufactured by Banner
Engineering Corp. Any misuse, abuse, or improper applicaꢀon or installaꢀon of this product or use of the product for personal protecꢀon applicaꢀons when the product is idenꢀfied as not intended for such purposes
will void the product warranty. Any modificaꢀons to this product without prior express approval by Banner Engineering Corp will void the product warranꢀes. All specificaꢀons published in this document are subject
to change; Banner reserves the right to modify product specificaꢀons or update documentaꢀon at any ꢀme. Specificaꢀons and product informaꢀon in English supersede that which is provided in any other language.
For the most recent version of any documentaꢀon, refer to: www.bannerengineering.com.
©
Banner Engineering Corp. All rights reserved
相关型号: