TL70 Wireless Communication Segment  
Datasheet  
®
Sure Cross Wireless TL70 Tower Lights combine the best of Banner's popular Tower Light family with its reliable, field proven,  
Sure Cross wireless architecture.  
Benefits  
Enables machine monitoring and Overall Equipment Effectiveness by collecting available machine data for analysis and to  
identify causes of lost production  
Lowers the cost and complexity of line and plant reconfigurations  
Provides an easy way to implement remote monitoring and the Industrial Internet of Things (IIoT)  
Easy Installation—Adds wireless communication and networking capabilities to new  
or existing TL70 Tower Lights  
Power Options—Works with either the standard dc-powered or ac-powered TL70  
base  
Input Flexibility—Accepts PNP or NPN inputs  
No Constant Power—Uses machine input power for lights and stores power to keep  
radio in sync  
Industrial Design—Rugged, water-resistant IP65 housing with UV-stabilized material  
Event Counter—Configure input wires as auxiliary sourcing inputs from external  
devices or as a 20 Hz, 32-bit event counter  
Powerful Radio—Available in 900 MHz (1 watt) and 2.4 GHz (65 mW) ISM Bands  
Models  
Model  
Base Color  
Black  
Frequency  
Input  
Output  
SG-TL70-DXN9  
SG-TL70-DXN9C  
SG-TL70-DXN2  
SG-TL70-DXN2C  
900 MHz ISM Band  
Six PNP/NPN discrete, 32-bit Synchronous Event  
Counter (enabled using DIP switches storing  
counter value with inputs 5 and 6)  
Gray  
Six Discrete Out  
Black  
2.4 GHz ISM Band  
Gray  
Configuration Instructions  
Set the Radio Module DIP Switches  
Before applying power to the device, set the radio module's DIP  
switches. Default configurations are noted with (*).  
DIP Switches  
Bank # 1 (1-4)  
DIP Switches  
Bank # 2 (5-8)  
LED  
Binding  
Push Button  
DIP Switch 1—The 900 MHz radios transmit at 1 Watt (30 dBm) or 250 mW (24 dBm). Refer to your Gateway's datasheet for more  
information.  
DIP Switch 1: Radio Transmit Power  
900 MHz Models  
2.4 GHz Models  
OFF *  
ON  
1 Watt (30 dBm) operation  
250 mW (24 dBm) operation  
Disabled  
Original Document  
204207 Rev. B  
13 March 2018  
204207  
TL70 Wireless Communication Segment  
DIP Switch 2—Use DIP switch 2 if:  
There are no light segments attached to the tower light base; or  
In conjunction with DIP switch 5 and constant power to read inputs back to the Gateway and control light segments  
independently from the Gateway using the output registers.  
DIP Switch 2: Input Wires  
900 MHz Models and 2.4 GHz Models  
OFF *  
ON  
Input wires control light segments  
Disables input wire control of light segments; input state is still reported back to the Gateway  
DIP Switch 3—In the default position (OFF), inputs 1 through 6 control the tower lights. When DIP switch 3 is ON, the input wire for  
Module 5 is the counter input and the input wire for Module 6 is disabled. Registers 5 and 6 store the 32- bit synchronous counter  
count. Inputs 5 and 6 are independent from the lights and will not drive any lights they are wired to. Input wires 1 through 4  
function normally. Using the counter input requires a TL70 with an 8-pin base to support the additional counting input.  
DIP Switch 3: Event Counter  
OFF *  
900 MHz Models and 2.4 GHz Models  
Default I/O operation  
Configure input 5 as a 32-bit synchronous counter at a maximum frequency of 20 Hz; disable input 6 (the  
counter requires two registers)  
ON  
DIP Switch 4—Bit packing uses a single register, or range of contiguous registers, to represent I/O values. This allows you to read  
or write multiple I/O values with a single Modbus message. Input 1 is stored in the least significant bit of register 1. Output 1 is  
stored in the least significant bit of register 9. DIP switch 4 in the ON position does not work with DIP switch 6 for flashing  
recognition.  
DIP Switch 4: Bit Packing I/O  
OFF *  
900 MHz Models and 2.4 GHz Models  
Default I/O operation  
Bit-packed I/O with all inputs in Modbus register 1 and all outputs in Modbus register 9. All other Modbus  
registers are disabled.  
ON  
DIP Switch 5—Enabling dc-powered mode with DIP switch 5 configures the input wire for Module 6 to accept a constant 24 V dc  
input. The TL70 can still accept inputs for up to 5 tower light segments and remotely control light segments from the Gateway.  
DIP Switch 5: Configure DC Power Mode  
900 MHz Models and 2.4 GHz Models  
Default I/O operation  
OFF *  
ON  
Enable dc-powered mode and remote light segment control  
DIP Switch 6—Enables the TL70 Wireless Node Segment to recognize a 0.8 Hz to 6 Hz flashing state produced on the input. This  
feature allows each light segment attached to have two separate states that can be recognized and tracked for reporting or  
triggering rules/functions when paired with the DXM100 Wireless Controller. The input register will alternate between a value of 2  
and 3 when the flashing state is active. DIP switch 6 in the ON position cannot be used in conjunction with DIP switch 4 (ON  
position).  
DIP Switch 6: Enable Flash Recognition  
900 MHz Models and 2.4 GHz Models  
OFF *  
ON  
Default I/O operation (Input register values: 0 = OFF, 1 = ON)  
Enables flash recognition (Input register values: 0 = OFF, 1 = ON, 2 = Flashing OFF, 3 = Flashing ON)  
DIP Switch 7—Allows the user to trigger the output of a light in a specific flash pattern. To use this feature constant power is  
required and DIP switch 5 must be turned ON. See Creating Host Controlled Flash Patterns on page 5 for more information.  
DIP Switch 7: Enable Host Controlled Flash  
900 MHz Models and 2.4 GHz Models  
Patterns  
OFF *  
ON  
Default I/O operation  
Enables host controlled flash patterns  
2
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 204207 Rev. B  
TL70 Wireless Communication Segment  
Event Counter  
To use the event counter, the measured (logic high) signal must be greater  
than or equal to 25 ms. The 32-bit count is stored in I/O registers 5 and 6.  
To zero out (clear) the event counter,  
Correct  
Map an input/button on a Gateway to Node register 14 to clear the  
counter when the input/button is activated; or  
From a host system, write a 1 (the output must transition from a zero  
to a one to reset the counter) to Node register 14 or write a 5424  
(0x1530) to Node control register 15.  
Incorrect  
RF firmware revision 5.3 or higher (on all products released after 3/20/2015) is  
required to use this feature.  
t = 0  
25 ms 50 ms 75 ms 100 ms  
Bind the TL70 to the Gateway and Assign the Node Address  
Before beginning the binding procedure, apply power to all the devices.  
DIP Switches  
Bank # 1 (1-4)  
DIP Switches  
Bank # 2 (5-8)  
LED  
Binding  
Push Button  
1. Enter binding mode on the Gateway.  
For housed models, triple-click button 2.  
For board-level modules, triple-click the button.  
For DXM models, under the ISM Radio menu, use the down arrow button to highlight the Binding menu. Click ENTER.  
On the board modules, the green/red LED flashes. On the housed models, both LEDs flash red.  
2. Assign the TL70 a Node address using the Gateway's rotary dials or the DXM's arrow keys. Use the left rotary dial for the  
left digit and the right rotary dial for the right digit. For example, to assign your TL70 to Node 01, set the left dial to 0 and  
the right dial to 1.  
Valid Node addresses are 01 through 47.  
3. Remove any components to access the circuit board in the radio module of the TL70.  
4. Enter binding mode on the TL70 by triple-clicking the button.  
The bicolor LED flashes alternately while it searches for a Gateway in binding mode. After the TL70 is bound, the LED is  
red and green for four seconds (looks amber), then it flashes four times (looks amber). The TL70 automatically exits binding  
mode, cycles power, and enters Run mode.  
5. For DXM Gateways, click BACK to exit binding for that specific Node address.  
6. Label the Node with the assigned address for future references.  
This makes it easier to identify the physical Node location within a multi-Node network.  
7. Reassemble the components back onto the base.  
8. Repeat steps 2 through 5 for as many TL70 Wireless Communication Segments as are needed for your network.  
9. After binding all TL70s, exit binding mode on the Gateway.  
For housed models, double-click button 2.  
For board-level modules, double-click the button.  
For DXM models, click BACK until you return to the main menu.  
LED Behavior for the Nodes  
Nodes do not sample inputs until they are communicating with the Gateway. The radios and antennas must be a minimum distance  
apart to function properly. Recommended minimum distances are:  
900 MHz 150 mW and 250 mW radios: 6 feet  
900 MHz 1 Watt radios: 15 feet  
2.4 GHz 65 mW radios: 1 foot  
P/N 204207 Rev. B  
www.bannerengineering.com - Tel: +1-763-544-3164  
3
TL70 Wireless Communication Segment  
LED (Bi-color)  
Node Status  
Flashing green  
Radio link okay  
In Binding mode  
Binding mode is complete  
Radio link error  
Device error  
Green and red flashing alternately  
Both colors are solid for 4 seconds, then flash 4 times; looks amber  
Flashing red, once every 3 seconds  
Flashing red, once every second  
Assemble the TL70 Wireless Communication Segment  
To assemble the modules:  
1. Position the TL70 Wireless Communication Segment on the base.  
The communication segment must mount directly to the TL70 base.  
2. Align the notches on each module and press together.  
3. Rotate the top module clockwise to lock into place (notches shown in  
the locked position).  
4. Assemble the remaining modules in the desired order.  
Follow the instructions and wiring diagrams on the TL70 Modular Tower Light  
datasheet, using either the standard or AC voltage base for triggering  
appropriate inputs.  
Align the notches  
Notches shown in locked position  
®
Sure Cross User Configuration Tool  
The User Configuration Tool (UCT) offers an easy way to link I/O points in your wireless network, view I/O register values, and set  
system communication parameters when a host system is not part of the wireless network. The software runs on any computer  
with the Windows Vista, Windows 7, Windows 8, or Windows 10 operating system.  
Use a USB to RS-485 adapter cable to connect a standalone DX80 Gateway to the  
computer. For DXM Controllers with an internal DX80 radio, connect a computer to the  
DXM Controller using a USB or Ethernet connection. Download the most recent revisions  
of the UCT software from Banner Engineering's website: www.bannerengineering.com/  
wireless.  
The USB to RS-485 adapter cable is not required for the DXM Controller. For standalone  
DX80 Gateway devices use:  
USB to RS-485 adapter cable model BWA-UCT-900 for 1 Watt radios  
USB to RS-485 adapter cable model BWA-HW-006 for all other radios  
Modbus Registers  
Modbus holding registers for the 8-pin models. On 5-pin models, the M5 and M6 modules are not available. When DIP Switch 7 and 5 are enabled, the I/O range for  
all outputs is up to 0xFFFF, based on which flash pattern message is being created. Input register values: 0 = OFF, 1 = ON and if DIP Switch 6 is enabled then 2 =  
Flashing OFF, 3 = Flashing ON is added.  
I/O  
Modbus Holding Register  
I/O Type  
I/O Range  
Holding Register  
Module #  
Representation (Dec.)  
Gateway  
Any Node  
Min.  
Max.  
Min.  
0
Max.  
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
1 + (Node# × 16)  
2 + (Node# × 16)  
3 + (Node# × 16)  
4 + (Node# × 16)  
5 + (Node# × 16)  
6 + (Node# × 16)  
7 + (Node# × 16)  
8 + (Node# × 16)  
9 + (Node# × 16)  
Discrete IN 1 / Bit-packed inputs ¹  
Discrete IN 2  
0
0
0
0
0
0
3 / 63  
3 / 63  
M1  
M2  
M3  
M4  
M5  
M6  
3
0
3
Discrete IN 3  
3
0
3
Discrete IN 4  
3
0
3
Discrete IN 5 / 32-bit event counter high word ²  
Discrete IN 6 / 32-bit event counter low word ²  
Reserved  
3 / 65535  
3 / 65535  
0
3 / 65535  
3 / 65535  
0
Device Message  
Discrete OUT 9 / Bit-picked outputs ¹  
0
1 / 63  
0
1 / 63  
M1  
4
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 204207 Rev. B  
TL70 Wireless Communication Segment  
I/O  
Modbus Holding Register  
I/O Type  
I/O Range  
Holding Register  
Module #  
Representation (Dec.)  
Gateway  
Any Node  
Min.  
Max.  
Min.  
Max.  
10  
11  
12  
13  
14  
15  
16  
10  
11  
12  
13  
14  
15  
16  
10 + (Node# × 16)  
11 + (Node# × 16)  
12 + (Node# × 16)  
13 + (Node# × 16)  
14 + (Node# × 16)  
15 + (Node# × 16)  
16 + (Node# × 16)  
Discrete OUT 10  
0
0
0
0
0
1
1
1
1
1
0
0
0
0
0
1
1
1
1
1
M2  
M3  
M4  
M5  
M6  
Discrete OUT 11  
Discrete OUT 12  
Discrete OUT 13  
Discrete OUT 14 / Zero out (clear) the counter ²  
Control Message  
Reserved  
¹ Active when DIP Switch 4 is enabled  
²Active when DIP Switch 3 is enabled  
Creating Host Controlled Flash Patterns  
When DIP switch 7 is enabled, a host controlled system can write a value of 0x0000 to 0xFFFF to an output register to enable that  
light segment in that specific flash pattern.  
Flash a TL70 light by entering a time-based bit mask into the output register. Bit 0 represents the first 62.5 ms time window, bit 1  
represents the second 62.5 ms window, etc.  
For example, turn ON the output from 0 to 250 ms, OFF from 250 to 500 ms, ON from 500 to 750 ms, then OFF again from 750 ms  
to 1 second by writing 0x0F0F to the appropriate output.  
Bit  
15  
0
14  
0
13  
0
12  
0
11  
1
10  
1
9
1
8
1
7
0
6
0
5
0
4
0
3
1
2
1
1
1
0
1
Bin  
Hex  
Light  
0
F
0
F
Turned off from 750 ms to 1 s  
Turned on from 500 to 750 ms  
Turned off from 250 to 500 ms  
Turned on from 0 to 250 ms  
Specifications  
Performance Radio with Internal Antenna Specifications  
Radio Range1  
900 MHz Compliance (1 Watt)  
900 MHz, 1 Watt (Internal antenna): Up to 3.2 km (2 miles) with line of sight  
FCC ID UE3RM1809: This device complies with FCC Part 15, Subpart C,  
15.247  
2.4 GHz, 65 mW (Internal antenna): Up to 1000 m (3280 ft) with line of sight  
IC: 7044A-RM1809  
Antenna Minimum Separation Distance  
900 MHz, 150 mW and 250 mW: 2 m (6 ft)  
900 MHz, 1 Watt: 4.57 m (15 ft)  
2.4 GHz Compliance  
FCC ID UE300DX80-2400 - This device complies with FCC Part 15, Subpart  
C, 15.247  
ETSI EN 300 328: V1.8.1 (2012-06)  
IC: 7044A-DX8024  
2.4 GHz, 65 mW: 0.3 m (1 ft)  
Radio Transmit Power  
900 MHz, 1 Watt: 30 dBm (1 W) conducted (up to 36 dBm EIRP)  
2.4 GHz, 65 mW: 18 dBm (65 mW) conducted, less than or equal to 20 dBm  
(100 mW) EIRP  
Link Timeout  
Gateway: Configurable via User Configuration Tool (UCT) software  
Node: Defined by Gateway  
Spread Spectrum Technology  
Radiated Immunity HF  
10 V/m (EN 61000-4-3)  
FHSS (Frequency Hopping Spread Spectrum)  
1
Range depends on the environment and decreases significantly without line of sight. Always verify your wireless network's range by performing a Site Survey.  
P/N 204207 Rev. B  
www.bannerengineering.com - Tel: +1-763-544-3164  
5
TL70 Wireless Communication Segment  
Tower Light Specifications  
Supply Voltage and Current  
Audible Alarm  
12 V dc to 30 V dc (Outside the USA: 12 V dc to 24 V dc, 10ꢀ) 2  
900 MHz Consumption: Maximum current draw is < 40 mA and typical  
current draw is < 30 mA at 24 V dc. (2.4 GHz consumption is less.)  
Standard Audible: 2.6 KHz 250 Hz oscillation frequency; maximum  
intensity (typical) 92 dB at 1 m (3.3 ft)  
Loud Audible: 2.6 KHz 250 Hz oscillation frequency; maximum intensity  
(typical) at 1 m (3.3 ft)  
Maximum Current (mA)  
Indicator Color or Audible Model  
DIP Switches  
Max Intensity (Loud Audible)  
at 12 V dc  
420  
285  
30  
at 30 V dc  
150  
120  
30  
9
10  
ON  
Blue, Green, White  
ON  
OFF  
ON  
OFF  
Intensity 4: 101 dB  
Intensity 3: 99 dB  
Intensity 2: 92 dB  
Intensity 1: 85 dB  
Red, Yellow, Orange  
Standard Audible  
ON  
OFF  
OFF  
Loud Audible (Intensity 1)  
Loud Audible (Intensity 2)  
Loud Audible (Intensity 3)  
Loud Audible (Intensity 4)  
18  
14  
40  
28  
160  
350  
70  
Audible Adjustment  
110  
Standard Audible: Rotate the cover until the desired volume is reached  
Loud Audible Adjustment: Select the desired volume using DIP switches 9  
and 10  
Typical Reduction in Sound Intensity with Audible Adjustment (maximum to  
Supply Protection Circuitry  
minimum):  
Protected against transient voltages  
Standard Audible: 8 dB  
Loud Audible: 16 dB  
Indicators  
Connections  
1 to 6 colors depending on model (Green, Red, Yellow, Blue, White, and  
5-pin M12/Euro-style quick disconnect, 8-pin M12/Euro-style quick  
disconnect, 150 mm (5.9 in) PVC cable with an M12/Euro-style quick  
disconnect, or 2 m (6.5 ft) unterminated cable, depending on model  
Orange)  
LEDs are independently selected  
Flash Rates: 1.5 Hz 10ꢀ and 3 Hz 10ꢀ  
Construction  
Indicator Response Time  
Bases, Segments, Covers: Polycarbonate  
Off Response: 150 µs (maximum) at 12 V dc to 30 V dc  
On Response: 180 ms (maximum) at 12 V dc; 50 ms (maximum) at 30 V dc  
Vibration and Mechanical Shock  
Vibration 10 Hz to 55 Hz 0.5 mm p-p amplitude per IEC 60068-2-6  
Shock 15G 11 ms duration, half sine wave per IEC 60068-2-27  
Indicator Characteristics  
Required Overcurrent Protection  
3
WARNING: Electrical connections must be  
made by qualified personnel in accordance with  
local and national electrical codes and  
regulations.  
Color  
Dominant Wavelength (nm)  
or Color Temperature (CCT)  
Color Coordinates  
Lumen  
Output  
(Typical at  
25 °C)  
x
y
Overcurrent protection is required to be provided by end product  
application per the supplied table.  
Green  
Red  
525 nm  
625 nm  
590 nm  
470 nm  
5000 K  
92  
40  
22  
32  
125  
33  
Overcurrent protection may be provided with external fusing or via Current  
Limiting, Class 2 Power Supply.  
Supply wiring leads < 24 AWG shall not be spliced.  
For additional product support, go to www.bannerengineering.com.  
Yellow  
Blue  
Supply Wiring (AWG)  
Required Overcurrent Protection (Amps)  
White  
Orange  
20  
22  
24  
26  
28  
30  
5.0  
3.0  
2.0  
1.0  
0.8  
0.5  
0.66  
0.33  
Operating Conditions  
–40 °C to +50 °C (–40 °F to +122 °F)  
95ꢀ at +50 °C maximum relative humidity (non-condensing)  
Environmental Rating  
IEC IP65  
Radiated Immunity HF  
10 V/m (EN 61000-4-3)  
Certifications  
2
For European applications, power this device from a Limited Power Source as defined in EN 60950-1.  
Refer to CIE 1931 chromaticity diagram or color chart, to show equivalent color with indicated color coordinates.  
3
6
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 204207 Rev. B  
TL70 Wireless Communication Segment  
Dimensions  
Model  
1 light module  
Height (H)  
87.6 mm (3.45 in)  
144.3 mm (5.68 in)  
137.3 mm (5.41 in)  
1 light module, 1 audible module  
2 light modules  
2 light modules, 1 audible  
module  
194 mm (7.64 in)  
187 mm (7.36 in)  
3 light modules  
3 light modules, 1 audible  
module  
243.7 mm (9.59 in)  
236.7 mm (9.32 in)  
293.4 mm (11.55 in)  
286.4 mm (11.28 in)  
343.1 mm (13.5 in)  
4 light modules  
4 light modules, 1 audible  
module  
5 light modules  
5 light modules, 1 audible  
module  
M30 × 1.5  
(mounting nut  
included)  
24.9 mm  
[0.98”]  
Internal threads  
1/2-14 NPT  
Max Torque: 2.25 Nm  
[20 in-lbf]  
M12 × 1  
Banner Engineering Corp. Limited Warranty  
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or  
replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not  
cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.  
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.  
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO  
BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES  
RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT,  
STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.  
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously  
manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the  
product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will  
void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at  
any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to:  
www.bannerengineering.com.  
©
Banner Engineering Corp. All rights reserved  

相关型号:

SG-TL70-DXN9

TL70 Wireless Communication Segment
BANNER

SG-TL70-DXN9C

TL70 Wireless Communication Segment
BANNER

SG-TL70-GR

TL70 Multicolor Tower Light Module
BANNER

SG-TL70-GY

TL70 Multicolor Tower Light Module
BANNER

SG-TL70-GYR

TL70 Multicolor Tower Light Module
BANNER

SG-XA3XXXX

HF/UHF SMD TCVCXO
ETC

SG010M3R0GB

3GHz low phase noise CW signal generator
NDK

SG01S

Ultraviolet selective SiC based UV sensor
ETC

SG02D0512A

2W DC/DC CONVERTER, SMD-Package, High isolation
DELTA

SG02D0515A

2W DC/DC CONVERTER, SMD-Package, High isolation
DELTA

SG02D1212A

2W DC/DC CONVERTER, SMD-Package, High isolation
DELTA

SG02D1215A

2W DC/DC CONVERTER, SMD-Package, High isolation
DELTA