SL10VB6V [BANNER]

SL10 Series Slot Sensor;
SL10VB6V
型号: SL10VB6V
厂家: Banner Engineering    Banner Engineering
描述:

SL10 Series Slot Sensor

文件: 总4页 (文件大小:464K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
SL10 Series Slot Sensor  
Datasheet  
Self-Contained Opposed-Mode Sensor Pair  
An easy-to-use self-contained opposed-mode sensor pair in a rugged U-shaped housing  
Easy and economical to mount  
Molded-in beam guides simplify mounting and beam placement  
10 mm slot width for a wide variety of sensing applications  
Applications include label detection, hole detection, gear tooth detection, edge guiding, parts  
detection and counting  
2 mm effective beam  
10 to 30V dc operation  
Bipolar PNP/NPN outputs  
Visible red beam  
Choose 1 millisecond or 300 microsecond response  
4-turn potentiometer sensitivity adjustment  
Dark or light operate  
Choose integral, unterminated cable or QD models  
WARNING: Not To Be Used for Personnel Protection  
Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device  
does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A sensor  
failure or malfunction can cause either an energized or de-energized sensor output condition.  
Models  
1
Models  
Sensing Beam  
Slot Width  
Cable  
Supply  
Voltage  
Output Type  
Response  
Repeatability  
SL10VB6V  
2 m (6.5ft) 5-wire cable  
5-Pin Euro-style QD  
2 m (6.5ft) 5-wire cable  
5-Pin Euro-style QD  
1 ms  
250 µs  
75 µs  
SL10VB6VQ  
SL10VB6VY  
SL10VB6VYQ  
10 V dc to 30 Bipolar NPN  
V dc and PNP  
Visible red, 680 nm  
10 mm (0.4 in)  
300 µs  
Overview  
The SL10 Series Slot Sensor (sometimes called a “Fork Sensor”)  
comprises an opposed-mode emitter and its receiver inside a single  
convenient housing.  
Opposed-mode sensing is very reliable, and the single self-contained  
housing provides easy installation, with no sensor alignment required. In  
addition, the molded-in arrow on the emitter portion of the housing and  
the slotted design on the receiver portion of the housing show at a  
glance the position of the beam, simplifying installation placement.  
Emitter  
Signal LED  
Power ON LED  
Receiver (Beam Aligns at Groove)  
Sensitivity  
Adjustment  
Figure 1. Features  
1
To order the 9 m (30 ft) PVC cable model, add the suffix "W/30" to the cabled model number. For example, Models with a quick disconnect require a mating  
cordset.  
Original Document  
58341 Rev. D  
23 February 2018  
58341  
SL10 Series Slot Sensor  
Gear Tooth Detection  
Edge Detection  
Register Mark Detection on Clear Film  
Packaging Film  
Register Marks  
Figure 2. Typical Applications  
LED Indicators  
The Slot Sensor features two LED Indicators: Power (green) and Signal (amber). They indicate the following:  
Green ON: Power ON  
Amber ON: Sensor sees light  
Amber flashing: Excess gain is marginal (1 to 1.5×) in light condition  
Select Light Operate/Dark Operate  
Connect the gray wire to +V (10 V dc to 30 V dc) for Dark Operate; and to dc common (or open) for Light Operate. See wiring diagrams.  
Wiring Diagrams  
Wiring Key  
1
+
1. Brown  
2. White  
3. Blue  
4. Black  
5. Gray*  
10-30V dc  
3
2
4
L
L
*For Dark operate, connect gray wire to + (brown). For Light operate, connect gray wire to - (blue).  
5*  
Note: Quick disconnect (QD) wiring diagrams are functionally identical.  
Adjust the Sensitivity  
Adjust the sensitivity by turning the 4-turn clutched Sensitivity potentiometer with a small slotted screwdriver.  
1. Apply power to the sensor.  
2. Turn the potentiometer fully counter-clockwise, 4 full turns or more to set the sensor to the minimum sensitivity.  
3. Present the Light condition.  
If the amber Signal Condition indicator is ON, that is the Light condition sensitivity position. If not, proceed to the next step.  
4. Turn the potentiometer clockwise, just until the amber Signal Condition indicator turns ON and note the position of the potentiometer.  
5. Present the Dark condition.  
6. Turn the potentiometer clockwise, just until the amber Signal Condition indicator turns ON, and note the position of the potentiometer.  
7. For maximum reliability, the difference between these two positions should be at least one full turn. Set the sensitivity midway between the  
two positions for best sensing results.  
If the object to be sensed is very thin and non-metallic, the sensor may emit too much light energy for the object to completely block the beam. To  
test this, place the object in the sensing position, and decrease the sensitivity until the amber LED goes OFF. Remove the object; verify that the  
indicator comes ON solidly. If this does not occur, investigate other sensing alternatives.  
2
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 58341 Rev. D  
SL10 Series Slot Sensor  
Specifications  
Supply Voltage and Current  
Environmental Rating  
IEC IP67; NEMA 6  
10 to 30V dc (10% max. ripple), 30 mA  
Supply Protection Circuitry  
Operating Conditions  
Protected against reverse polarity and transient voltages  
−40 °C to +70 °C (−40 °F to +158 °F)  
90% at +50 °C maximum relative humidity (non-condensing)  
Required Overcurrent Protection  
Output Configuration  
Bipolar: NPN and PNP  
Output Rating  
WARNING: Electrical connections must be made by  
150 mA, each output  
qualified personnel in accordance with local and  
Output Protection Circuitry  
national electrical codes and regulations.  
Protected against output short-circuit and false pulse on power up  
Overcurrent protection is required to be provided by end product application per the  
supplied table.  
Output Response Time  
1 millisecond or 300 microseconds, depending on model  
Overcurrent protection may be provided with external fusing or via Current Limiting,  
Class 2 Power Supply.  
Repeatability  
250 microseconds or 75 microseconds, depending on model  
Supply wiring leads < 24 AWG shall not be spliced.  
For additional product support, go to www.bannerengineering.com.  
Adjustments  
4-turn clutched potentiometer sensitivity adjustment  
Supply Wiring (AWG)  
Required Overcurrent Protection (Amps)  
Slot Opening  
10 mm (0.4 in) wide x 45 mm (1.8 in) deep overall; beam set in 10 mm (0.4 in) from  
20  
22  
24  
26  
28  
30  
5.0  
3.0  
2.0  
1.0  
0.8  
0.5  
outer edge  
Indicators  
Green: Power on/off indicator  
Amber: Signal condition indicator  
Construction  
Housing: ABS/polycarbonate blend  
Optic windows: acrylic  
Connections  
2 m (6.5 ft) or 9 m (30 ft) 5-conductor PVC-jacketed attached cable or 5-pin Euro-style  
quick-disconnect (QD) connector  
Certifications  
E224071  
Dimensions  
10.0 mm  
(0.39)  
10.0 mm  
(0.39)  
45.0 mm  
(1.77")  
72.0 mm  
(2.84")  
Power LED  
(Green)  
Signal LED  
(Amber)  
6.0 mm  
(0.24")  
20.2 mm (0.80")  
40.0 mm  
(1.58")  
2x ø5.6 mm  
(0.22")  
6.0 mm  
(0.24")  
M12 x 1  
52.0 mm  
(2.05")  
17.5 mm  
(0.69")  
18.8 mm  
(0.74")  
11.5 mm  
(0.45")  
All measurements are listed in millimeters [inches], unless noted otherwise.  
P/N 58341 Rev. D  
www.bannerengineering.com - Tel: +1-763-544-3164  
3
SL10 Series Slot Sensor  
Accessories  
Cordsets  
5-Pin Threaded M12/Euro-Style Cordsets—Single Ended  
Model  
Length  
Style  
Dimensions  
Pinout (Female)  
MQDC1-501.5  
MQDC1-506  
MQDC1-515  
0.50 m (1.5 ft)  
1.83 m (6 ft)  
4.57 m (15 ft)  
44 Typ.  
Straight  
M12 x 1  
2
MQDC1-530  
9.14 m (30 ft)  
ø 14.5  
1
4
3
5
MQDC1-506RA  
MQDC1-515RA  
1.83 m (6 ft)  
32 Typ.  
[1.26"]  
4.57 m (15 ft)  
1 = Brown  
2 = White  
3 = Blue  
4 = Black  
5 = Gray  
30 Typ.  
[1.18"]  
Right-Angle  
MQDC1-530RA  
9.14 m (30 ft)  
M12 x 1  
ø 14.5 [0.57"]  
Brackets  
SMBSL  
52  
Angled bracket  
304 stainless steel  
Hardware included  
6 X  
40  
Ø5.5  
41  
19  
Banner Engineering Corp. Limited Warranty  
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge,  
any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or  
the improper application or installation of the Banner product.  
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR  
FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.  
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER  
PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR  
FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.  
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner  
Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such  
purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this  
document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is  
provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com.  
©
Banner Engineering Corp. All rights reserved  

相关型号:

SL10VB6VQ

SL10 Series Slot Sensor
BANNER

SL10VB6VY

SL10 Series Slot Sensor
BANNER

SL10VB6VYQ

SL10 Series Slot Sensor
BANNER

SL11

Ceramic Capacitor, Ceramic, Through Hole Mount, AXIAL LEADED
MURATA

SL1100

SEVEN-SEGMENT NUMERIC LED DISPLAY,1-CHARACTER,RED,DIP
ONSEMI

SL110A

Surface Mount Schottky Barrier Rectifier
GOOD-ARK

SL110N0

Telecom and Datacom Connector, 110 Contact(s), Male, Solder Terminal
MOLEX

SL110N1

Telecom and Datacom Connector, 110 Contact(s), Male, Solder Terminal
MOLEX

SL110N2

Telecom and Datacom Connector, 110 Contact(s), Male, Solder Terminal
MOLEX

SL110N3

Telecom and Datacom Connector, 110 Contact(s), Male, Solder Terminal
MOLEX

SL110N4

Telecom and Datacom Connector, 110 Contact(s), Male, Solder Terminal
MOLEX

SL110P0

Telecom and Datacom Connector, 110 Contact(s), Male, Crimp Terminal
MOLEX