SMB30RAVK [BANNER]
EZ-LIGHT® Touch Gen 2 K50 Specialty Pick-to-Light;型号: | SMB30RAVK |
厂家: | Banner Engineering |
描述: | EZ-LIGHT® Touch Gen 2 K50 Specialty Pick-to-Light |
文件: | 总4页 (文件大小:404K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
®
EZ-LIGHT Touch Gen 2 K50 Specialty Pick-to-Light
Datasheet
Compact, Single-Point Devices for Error-Proofing of Bin-Picking Operaꢀons
•
•
Excellent immunity to false triggering by water spray, detergents, oils, and other foreign
materials
Rugged, cost-eꢀecꢁve and easy-to-install soluꢁons for error-proofing and parts-
verificaꢁon applicaꢁons
•
•
•
•
•
•
Compact devices are completely self contained—no controller needed
Waterproof IEC IP69K construcꢁon for washdown environments
Easy actuaꢁon—no force required
12 V dc to 30 V dc operaꢁon
Can be actuated with bare hands or gloves
Compact models available for lower profile applicaꢁons
Standard Model
Compact Model
WARNING: Not To Be Used for Personnel Protecꢀon
Never use this device as a sensing device for personnel protecꢀon. Doing so could lead to serious injury or death. This device
does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applicaꢁons. A sensor failure
or malfuncꢁon can cause either an energized or de-energized sensor output condiꢁon.
Models
Indicators
1
2
Model
Funcꢀon
Output
Connecꢀon
Job
Mispick
Sense
K50APT2GRYC3Q
K50RPT2GRYC3Q
K50APT2GRYC4Q
K50RPT2GRYC4Q
•
•
Job light always illuminated with job input unꢁl touched
PNP, N.O.
Touch acꢁvates output and overrides job light with sense
light
Green
Red
Yellow
PNP, N.C.
PNP, N.O.
PNP, N.C.
•
Touch with inacꢁve job input acꢁvates mispick light and
acꢁvates output
Integral 5-pin M12/
Euro-style male quick
disconnect (QD)
•
•
Job light always illuminated with job input unꢁl touched
Touch acꢁvates output and overrides job light with sense
light unꢁl job input is removed
Green
Red
Yellow
•
Touch with inacꢁve job input acꢁvates mispick light for 5
seconds aꢂer touched and acꢁvates output
Wiring Diagrams
NPN Models
Wiring Key
PNP Models
1 = Brown
1
3
2 = White
3 = Blue
4 = Black
5 = Gray
1
3
+
+
12-30V dc
–
12-30V dc
–
4
4
2
5
Load
Load
2
5
Job Light Enable,
Input High >7V
Job Light Enable,
Input Low <1.0V
Not Used
Not Used
Note: Cabled wiring diagrams are shown. Quick disconnect (QD) wiring diagrams are funcꢁonally idenꢁcal.
1
2
Integral 5-pin M12/Euro-style quick disconnect models are listed.
•
•
To order the 2 m (6.5 ꢂ) PVC cable model, omit the suffix "Q" in the model number. For example K50APT2GRYC3.
To order the 150 mm (6 in) PUR cable model with a 5-Pin M12/Euro-style quick disconnect, replace the suffix "Q" with "QPMA" in the model number. For example,
K50APT2GRYC3QPMA.
•
To order the 150 mm (6 in) PVC cable model with a 5-pin M12/Euro-style quick disconnect, replace the suffix "Q" with "QP" in the model number. For example,
K50APT2GRYC3QP.
•
•
To order a compact model, add the suffix "C" aꢂer K50 in the model number. For example, K50CAPTLGRYC3Q.
Models with a quick disconnect require a maꢁng cordset.
PNP models only are listed. For other output types, contact Banner Engineering.
Original Document
189831 Rev. D
23 June 2017
189831
®
EZ-LIGHT Touch Gen 2 K50 Specialty Pick-to-Light
Indicator and Output Behavior
Indicator
Sensor Condiꢀons
Output Signal Status
C3 Models
C4 Models
Hand/pick absent
Hand/pick present
Hand/pick absent
Hand/pick present
On Green
On Green
Oꢀ
On
Oꢀ
On
Job input acꢁve
On Yellow
Oꢀ
On Yellow unꢁl job input is removed
Oꢀ
No job input
On Red
On Red for 5 seconds aꢂer hand/pick is removed
Note: "C3" and "C4" models as referenced in the table pertain to a part of the product model number, immediately preceding the designaꢁon.
Speciꢁcaꢀons
Supply Voltage
Indicator Lumens
12 V dc to 30 V dc
Color
Green
Red
Typical Wavelength
525 nm
Typical Intensity (lm)
Supply Current
< 75 mA max current at 12 V dc (exclusive of load)
< 50 mA max current at 30 V dc (exclusive of load)
29
13
24
625 nm
Supply Protecꢀon Circuitry
Protected against reverse polarity and transient voltages
Yellow
591 nm
Output Raꢀng
Maximum load: 150 mA
ON-state saturaꢁon voltage: < 2 V dc at 10 mA; < 2.5 V dc at 150 mA
OFF-state leakage current: <10 µA at 30 V dc
Mounꢀng
M30 × 1.5 threaded base max. torque 4.5 N·m (40 in·lbf)
Output Response Time
50 milliseconds On
Environmental Raꢀng
IEC IP67, IP69K per DIN 40050-9.
Cabled models also meet IP69K if the cable and cable entrance are protected from high-
pressure spray.
500 milliseconds leading edge Oꢀ
Power-Up Delay
300 milliseconds
Operaꢀng Condiꢀons
Required Overcurrent Protecꢀon
–40 °C to +50 °C (–40 °F to +122 °F)
90% at 50 °C maximum relaꢁve humidity (non-condensing)
WARNING: Electrical connecꢁons must be made by
qualified personnel in accordance with local and naꢁonal
electrical codes and regulaꢁons.
Storage Condiꢀons
–40 °C to +70 °C (–40 °F to +158 °F)
Overcurrent protecꢁon is required to be provided by end product applicaꢁon per the
supplied table.
Construcꢀon
Housing: polycarbonate
Translucent dome: polycarbonate
Mounꢁng nut: PBT
Overcurrent protecꢁon may be provided with external fusing or via Current Limiꢁng, Class
2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For addiꢁonal product support, go to www.bannerengineering.com.
Connecꢀons
5-pin integral M12/Euro-style QD, 2 m (6.5 ꢂ) PVC integral cable, 5-pin 150 mm (6 in)
M12/Euro-style PUR cable QD, or 5-pin 150 mm (6 in) M12/Euro-style PVC cable QD
Supply Wiring (AWG)
Required Overcurrent Protecꢀon (Amps)
Vibraꢀon and Mechanical Shock
20
22
24
26
28
30
5.0
3.0
2.0
1.0
0.8
0.5
Vibraꢁon 10 Hz to 55 Hz 1.0 mm p-p amplitude per IEC 60068-2-6
Shock 30G 11 ms duraꢁon, half sine wave per IEC 60068-2-27
Cerꢀꢁcaꢀons
Dimensions
Standard Models
Compact Models
35 mm
[1.38”]
55 mm
[2.17”]
17 mm
[0.67”]
37.0 mm
[1.46”]
48.0 mm
[1.89”]
66 mm
[2.6”]
M30 x 1.5
Ø50 mm
[1.97”]
Ø50 mm
[1.97”]
M12 x 1
2
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 189831 Rev. D
®
EZ-LIGHT Touch Gen 2 K50 Specialty Pick-to-Light
All measurements are listed in millimeters [inches], unless noted otherwise.
Accessories
Cordsets
5-Pin Threaded M12/Euro-Style Cordsets—Single Ended
Model
Length
Style
Dimensions
Pinout (Female)
MQDC1-501.5
MQDC1-506
MQDC1-515
0.50 m (1.5 ꢂ)
1.83 m (6 ꢂ)
4.57 m (15 ꢂ)
44 Typ.
Straight
M12 x 1
2
MQDC1-530
9.14 m (30 ꢂ)
ø 14.5
1
4
3
5
MQDC1-506RA
MQDC1-515RA
1.83 m (6 ꢂ)
32 Typ.
[1.26"]
4.57 m (15 ꢂ)
1 = Brown
2 = White
3 = Blue
4 = Black
5 = Gray
30 Typ.
[1.18"]
Right-Angle
MQDC1-530RA
9.14 m (30 ꢂ)
M12 x 1
ø 14.5 [0.57"]
All measurements are listed in millimeters [inches], unless noted otherwise.
Brackets
SMB30A
SMB30FA
83.2
45
•
Right-angle bracket with curved slot
•
Swivel bracket with ꢁlt and pan
for versaꢁle orientaꢁon
movement for precise adjustment
C
•
•
•
Clearance for M6 (¼ in) hardware
Mounꢁng hole for 30 mm sensor
12-ga. stainless steel
•
•
•
Mounꢁng hole for 30 mm sensor
12-ga. 304 stainless steel
Easy sensor mounꢁng to extrude rail
T-slot
61
B
68.9
36.3
B
A
•
Metric and inch size bolt available
A
69
Hole center spacing: A to B=40
Hole size: A=ø 6.3, B= 27.1 x 6.3, C=ø 30.5
Bolt thread: SMB30FA, A= 3/8 - 16 x 2 in; SMB30FAM10, A= M10 - 1.5 x 50
Hole size: B= ø 30.1
SMB30FVK
SMB30MM
•
•
•
V-clamp, flat bracket and fasteners
•
12-ga. stainless steel bracket with
curved mounꢁng slots for versaꢁle
orientaꢁon
Clearance for M6 (¼ in) hardware
Mounꢁng hole for 30 mm sensor
57
70
for mounꢁng to pipe or extensions
46
A
118
Clamp accommodates 28 mm dia.
tubing or 1 in. square extrusions
30 mm hole for mounꢁng sensors
•
•
C
57
B
A
Hole size: A= ø 31
Hole center spacing: A = 51, A to B = 25.4
Hole size: A = 42.6 x 7, B = ø 6.4, C = ø 30.1
P/N 189831 Rev. D
www.bannerengineering.com - Tel: +1-763-544-3164
3
®
EZ-LIGHT Touch Gen 2 K50 Specialty Pick-to-Light
SMB30RAVK
SMB30SC
67
A
•
V-clamp, right-angle bracket and
•
Swivel bracket with 30 mm mounꢁng
fasteners for mounꢁng sensors to
hole for sensor
B
pipe or extrusion
•
•
Black reinforced thermoplasꢁc
polyester
Stainless steel mounꢁng and swivel
locking hardware included
46
•
•
Clamp accommodates 28 mm dia.
58
tubing or 1 in. square extrusions
30 mm hole for mounꢁng sensors
90
57
29
A
Hole size: A = ø 30.5
Hole center spacing: A=ø 50.8
Hole size: A=ø 7.0, B=ø 30.0
SMBAMS30P
SMBAMS30RA
45
45
•
•
•
•
Flat SMBAMS series bracket
•
•
•
•
Right-angle SMBAMS series bracket
30 mm hole for mounꢁng sensors
Arꢁculaꢁon slots for 90°+ rotaꢁon
12-ga. 300 series stainless steel
30 mm hole for mounꢁng sensors
Arꢁculaꢁon slots for 90°+ rotaꢁon
12-ga. (2.6 mm) cold-rolled steel
C
C
53
A
A
93
B
B
48
Hole center spacing: A=26.0, A to B=13.0
Hole size: A=26.8 x 7.0, B=ø 6.5, C=ø 31.0
Hole center spacing: A=26.0, A to B=13.0
Hole size: A=26.8 x 7.0, B=ø 6.5, C=ø 31.0
Ø A
TC-K50-CL
•
Touch cover
B
Diameter: A = 67 mm
Height: B = 42.5 mm
Banner Engineering Corp. Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any
product of its manufacture which, at the ꢁme it is returned to the factory, is found to have been defecꢁve during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the
improper applicaꢁon or installaꢁon of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discreꢁon of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR
ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO
USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligaꢁons or liabiliꢁes relaꢁng to any product previously manufactured by Banner
Engineering Corp. Any misuse, abuse, or improper applicaꢁon or installaꢁon of this product or use of the product for personal protecꢁon applicaꢁons when the product is idenꢁfied as not intended for such purposes
will void the product warranty. Any modificaꢁons to this product without prior express approval by Banner Engineering Corp will void the product warranꢁes. All specificaꢁons published in this document are subject
to change; Banner reserves the right to modify product specificaꢁons or update documentaꢁon at any ꢁme. Specificaꢁons and product informaꢁon in English supersede that which is provided in any other language.
For the most recent version of any documentaꢁon, refer to: www.bannerengineering.com.
FCC Part 15 and CAN ICES-3 (B)/NMB-3(B)
This device complies with part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). Operaꢁon is subject to the following two condiꢁons:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operaꢁon.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). These limits are designed to provide reasonable
protecꢁon against harmful interference in a residenꢁal installaꢁon. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instrucꢁons, may cause
harmful interference to radio communicaꢁons. However, there is no guarantee that interference will not occur in a parꢁcular installaꢁon. If this equipment does cause harmful interference to radio or television
recepꢁon, which can be determined by turning the equipment oꢀ and on, the user is encouraged to try to correct the interference by one or more of the following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separaꢁon between the equipment and receiver.
Connect the equipment into an outlet on a circuit diꢀerent from that to which the receiver is connected.
Consult the manufacturer.
©
Banner Engineering Corp. All rights reserved
相关型号: