T30UXUC [BANNER]

T30UX Series with Analog Output;
T30UXUC
型号: T30UXUC
厂家: Banner Engineering    Banner Engineering
描述:

T30UX Series with Analog Output

文件: 总11页 (文件大小:583K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
®
U-GAGE T30UX Series with Analog Output  
Datasheet  
Ultrasonic Sensor with TEACH-Mode Configuration  
1, 2 and 3 m (3.28, 6.56, and 9.84 ft) versions with short dead zones  
(10% of max range)  
Built-in temperature compensation  
Fast, easy-to-use TEACH-Mode programming; no potentiometer  
adjustments  
Configure with either a positive or negative analog output slope  
Remote TEACH for security and convenience  
Wide operating temperature range of 40° to +70° C (40° to +158° F)  
Choose either 0 to 10V dc or 4 to 20 mA output model  
Compact, self-contained, right-angle sensor package with fully  
encapsulated electronics  
Models  
1
Models  
Range and Frequency  
Cable  
Supply Voltage  
Analog Output  
0 to 10 V dc  
4 to 20 mA  
Response Time  
T30UXUA  
T30UXIA  
T30UXUB  
T30UXIB  
T30UXUC  
T30UXIC  
100 mm to 1 m (3.9 in to 39 in)  
224 kHz  
45 ms or 105 ms selectable  
200 mm to 2 m (7.8 in to 78 in)  
174 kHz  
0 to 10 V dc  
4 to 20 mA  
Standard 2 m  
(6.5 ft) cable  
10 to 30 V dc  
92 ms or 222 ms selectable  
135 ms or 318 ms selectable  
300 mm to 3 m (11.8 in to 118 in)  
114 kHz  
0 to 10 V dc  
4 to 20 mA  
WARNING: Not To Be Used for Personnel Protection  
Never use this device as a sensing device for personnel protection. Doing so could lead to  
serious injury or death. This device does not include the self-checking redundant circuitry necessary  
to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an  
energized or de-energized sensor output condition.  
Overview  
®
The U-GAGE T30UX is an easy-to-use ultrasonic sensor with extended  
Power ON/OFF  
LED (Green)  
Signal Strength  
LED (Red)  
range and built-in temperature compensation. Simple push button  
configuration provides flexibility for a variety of applications.  
Discrete Output  
LED (Amber)  
Easy-to-see indicator LEDs communicate the status of the sensor. The Green  
“Power” LED ON indicates that the sensor is in Run Mode (the sensor’s  
normal operating condition). The Red “Signal” LED indicates the target  
signal strength. The Amber “Output” LED indicates that the output is  
enabled and the sensor is receiving a signal within the window limits. The  
Amber “Mode” LED indicates the currently selected mode(fast or slow).  
Mode LEDs  
(Amber)  
Figure 1. Features  
1
Only standard 2 m (6.5 ft) cable models are listed. To order the 4-Pin Euro-Style integral QD, add suffix “Q8” to the model number (for example,  
T30UXUAQ8). To order the 150 mm (6 in) PUR pigtail cable with 4-Pin threaded Euro-Style QD, add suffix “QPMA” to the model number (for  
example, T30UXUAQPMA). To order the 9 m (30 ft) cable, add suffix “W/30” to the model number (for example, T30UXUA W/30). A model  
with a QD connector requires a mating cable; see Quick-Disconnect Cables on page 10.  
Original Document  
141958 Rev. E  
19 September 2016  
141958  
®
U-GAGE T30UX Series with Analog Output  
Principles of Operation  
Ultrasonic sensors emit one or multiple pulses of ultrasonic energy, which travel through the air at the speed of sound. A  
portion of this energy reflects off the target and travels back to the sensor. The sensor measures the total time required  
for the energy to reach the target and return to the sensor. The distance to the object is then calculated using the  
following formula: D = ct ÷ 2  
D = distance from the sensor to the target  
c = speed of sound in air  
t = transit time for the ultrasonic pulse  
To improve accuracy, an ultrasonic sensor may average the results of several pulses before outputting a new value.  
Temperature Effects  
The speed of sound is dependent upon the composition, pressure and temperature of the gas in which it is traveling. For  
most ultrasonic applications, the composition and pressure of the gas are relatively fixed, while the temperature may  
fluctuate.  
In air, the speed of sound varies with temperature according to the following approximation:  
In metric  
units:  
In English units:  
C
=
=
C
ft/s  
49 460 + T  
F
20 273 + T  
m/s  
C
Cm/s = speed of sound in meters per second  
TC = temperature in °C  
Cft/s = speed of sound in feet per second  
TF = temperature in °F  
Temperature Compensation  
Changes in air temperature affect the speed of sound, which in turn affects the total time for the echo measured by the  
sensor. An increase in air temperature shifts both sensing window limits closer to the sensor. Conversely, a decrease in air  
temperature shifts both limits farther away from the sensor. This shift is approximately 3.5% of the limit distance for a 20°  
C change in temperature.  
The T30UX series ultrasonic sensors are temperature compensated. This reduces the error due to temperature by about  
90%. The sensor will maintain its window limits to within 2.2% over the -40° to +70° C (40° to +158° F) operating  
range of the sensor.  
NOTE:  
Exposure to direct sunlight can affect the sensor’s ability to accurately compensate for changes  
in temperature.  
If the sensor is measuring across a temperature gradient, the compensation will be less  
effective.  
Configuration Instructions  
Sensor Configuration  
Two TEACH methods may be used to configure the sensor:  
Teach individual minimum and maximum limits, or  
Use Auto-Window feature to center a sensing window around the taught position.  
The sensor may be configured either via its push button, or via a remote switch. Remote configuration also may be used to  
disable the push button, preventing unauthorized personnel from adjusting the configuration settings. To access this  
feature, connect the white wire of the sensor to 0V dc, with a remote configuration switch between the sensor and the  
voltage.  
Configuration is accomplished by following the sequence of input pulses. The duration of each pulse (corresponding to a  
push button “click”), and the period between multiple pulses, are as “T”: 0.04 seconds < T < 0.8 seconds  
Remote line configuration requires a greater than 1 second pause between pulse sequences.  
Mode Setup - Response Speed  
Analog sensor models can be set up for either “Fast” or “Slow” response time. A button click or pulse on the remote line is:  
0.04 s < T < 0.8 s.  
1. Enter Response Speed Mode setup mode.  
2
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 141958 Rev. E  
®
U-GAGE T30UX Series with Analog Output  
Method  
Action  
Result  
Power LED: OFF  
Push Button  
Push and hold MODE push button for > 2 seconds.  
Mode LED: Flashing Amber shows  
previously selected mode  
Power LED: OFF  
T
T
Remote Input  
Mode LED: Flashing Amber shows  
previously selected mode  
T
Double-pulse the remote line.  
2. Select the speed.  
Method  
Action  
Result  
Power LED: OFF  
Mode LED: Amber flashes to indicate  
Push Button  
Click the MODE button to cycle to the correct selection: Fast or Slow.  
Single-pulse to select Slow; double-pulse to select Fast.  
currently selected mode (120 second time  
2
out )  
Power LED: ON Green  
Remote Input  
Mode LED: ON Amber shows selected  
mode (Sensor returns to RUN mode)  
3. Save and return to Run mode.  
Method  
Action  
Result  
Power LED: ON Green  
Push Button  
Remote Input  
Push and hold the MODE button for more than 2 seconds.  
No action is required; the sensor will return to Run Mode.  
Mode LED: ON Amber for selected mode  
None  
Analog Output  
The U-GAGE T30UX series sensor may be configured for either a positive or a negative output slope, based on which  
condition is taught first (see Figure 2 on page 3). If the near limit is taught first, the slope will be positive; if the far  
limit is taught first, the slope will be negative. Banner’s scalable analog output automatically distributes the output signal  
over the width of the programmed sensing window.  
The U-GAGE T30UX also features a 2-second hold upon loss of the received signal, which is useful for harsh and unstable  
applications. In the event of signal loss for longer than 2 seconds, the analog output goes to 3.6 mA or 0V dc, which may  
be used to trigger an alarm.  
Current-Sourcing Models  
Voltage-Sourcing Models  
20  
10  
Positive  
Slope  
Positive  
Slope  
Negative  
Slope  
Negative  
Slope  
4
0
Near  
Window  
Far  
Window  
Near  
Window  
Far  
Window  
Target Position  
Target Position  
Figure 2. Positive and Negative Output Slopes  
Teaching Minimum and Maximum Limits  
General Notes on Teaching  
The sensor returns to RUN mode if the first TEACH condition is not registered within 120 seconds after the initial 2  
second hold on the Analog button.  
2
The sensor will revert to previously saved configuration and return to RUN mode if TEACH is inactive for 120 seconds after the initial 2 second  
hold on push button  
P/N 141958 Rev. E  
www.bannerengineering.com - Tel: +1-763-544-3164  
3
®
U-GAGE T30UX Series with Analog Output  
To exit TEACH mode without saving any changes, press and hold the Analog button or remote line longer than 2  
seconds (before teaching the second limit). The sensor reverts to the last saved limits.  
After the first limit is taught, the sensor remains in TEACH mode until the TEACH sequence is finished or exited by  
a 2 second hold on the Analog button or remote line.  
A button click or pulse on the remote line is: 0.04 s < T < 0.8 s.  
1. Enter TEACH mode.  
Method  
Action  
Result  
Power LED: OFF  
Output LED: ON  
Push Button  
Remote Input  
Push and hold the Analog push button longer than 2 seconds.  
No action required; sensor is ready for first limit teach.  
None  
2. Teach the first limit.  
Method  
Action  
Position the target for the first limit (120 second time out).  
Result  
Signal LED: Must be ON Red or Flashing  
3
Red  
Teach Accepted  
Push Button  
Power LED: OFF  
Output LED: Flashing  
“Click” the Analog button.  
Teach Not Accepted  
Output LED: ON  
Signal LED: Must be ON Red or Flashing  
Red  
Position the target for the first limit.  
3
Teach Accepted  
Remote Input  
Power LED: OFF  
Output LED: Flashing  
T
Single-pulse the remote line.  
Teach Not Accepted  
Power LED: ON  
3. Teach the second limit.  
Method  
Action  
Result  
Signal LED: Must be ON Red or Flashing  
Red  
Position the target for the second limit (no time out).  
Teach Accepted  
Output LED: ON  
Power LED: ON  
Push Button  
“Click” the Analog button.  
Teach Not Accepted  
Output LED: Flashing  
Power LED: OFF  
Signal LED: Must be ON Red or Flashing  
Red.  
Position the target for the second limit (no time out).  
Teach Accepted  
Output LED: Turns ON  
Power LED: ON  
Remote Input  
T
Single-pulse the remote line.  
Teach Not Accepted  
Output LED: Flashing  
Power LED: OFF  
Teaching Limits Using the Auto-Window Feature  
Teaching the same limit twice automatically centers a 100 mm window on the taught position .  
General Notes on Teaching  
The sensor returns to RUN mode if the TEACH condition is not registered within 120 seconds after the initial 2  
second hold on the Analog button.  
To exit TEACH mode without saving any changes, press and hold the Analog button or remote line longer than 2  
seconds (before teaching the second limit). The sensor will revert to the last saved limits.  
3
Sensor will not Teach or indicate “Teach Not Accepted” when there is no signal present (Signal LED Red or Flashing Red)  
4
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 141958 Rev. E  
®
U-GAGE T30UX Series with Analog Output  
After the first limit is taught, the sensor remains in TEACH mode until the TEACH sequence is finished or exited by  
a 2 second hold on the Analog button or remote line.  
A button click or pulse on the remote line is: 0.04 s < T < 0.8 s.  
1. Enter TEACH mode.  
Method  
Action  
Result  
Power LED: OFF  
Output LED: ON  
Push Button  
Remote Input  
Push and hold the Analog button longer than 2 seconds.  
No action required; the sensor is ready for the first limit teach.  
None  
2. Teach the first limit.  
Method  
Action  
Result  
Signal LED: Must be ON Red or Flashing  
Red  
Position the target for the center of window (120 second time out).  
4
Teach Accepted  
Push Button  
Power LED: OFF  
Output LED: Flashing  
Click the Analog push button.  
Teach Not Accepted  
Output LED: ON  
Signal LED: Must be ON Red or Flashing  
Red  
Position the target for the center of window.  
4
Teach Accepted  
Single-pulse the remote line.  
Remote Input  
Power LED: OFF  
T
Output LED: Flashing  
Teach Not Accepted  
Output LED: ON  
3. Re-teach the limit.  
Method  
Action  
Result  
Teach Accepted  
Output LED: ON  
Power LED: ON  
Push Button  
Without moving the target, “click” the Analog push button again  
Teach Not Accepted  
Output LED: Flashing  
Power LED: OFF  
Teach Accepted  
Without moving the target, single-pulse the remote line again.  
Output LED: ON  
Power LED: ON  
T
Remote Input  
Teach Not Accepted  
Output LED: Flashing  
Power LED: OFF  
Remote Line TEACH  
General Notes  
Run Mode is the sensor’s normal operating condition  
The duration of each Pulse is defined as “T”: 0.04 < T < 0.8 s  
T
A Hold will exit TEACH MODE and return to Run Mode with previously saved changes. The duration of a Hold is: T  
> 2 s  
A Timeout will occur if a condition is not registered within 120 seconds, causing the sensor to return to Run Mode  
(during sensor configuration only)  
Sensor configuration user feedback shown on Green LED. See flowchart.  
4
Sensor will not Teach or indicate “Teach Not Accepted” when there is no signal present (Signal LED Red or Flashing Red)  
P/N 141958 Rev. E  
www.bannerengineering.com - Tel: +1-763-544-3164  
5
®
U-GAGE T30UX Series with Analog Output  
The Red Signal LED will be ON whenever the target is in view.  
Power LED ON,  
Exit  
Run Mode All other LEDs in normal  
operating condition  
No valid target  
1x  
TEACH MODE  
(1st pulse teaches 1st limit)  
Power LED OFF,  
Output LED Flashing  
2 s Hold  
1x  
Power LED ON,  
Output LED ON  
Teach 2nd limit  
No valid target  
2x  
Power LED OFF.  
Mode LED Flashing  
Output Configuration Menu  
1x  
2x  
3x  
Slow Speed (default)  
Fast Speed  
Slow LED ON  
Fast LED ON  
Positive Slope  
(default)  
Flash Power 3x,  
Repeat twice  
4x  
Flash Power 4x,  
Repeat twice  
Negative Slope  
2 s Hold  
120 second Timeout  
3x  
Advanced Sensor  
Configuration Menu  
Power LED OFF,  
Mode LEDs OFF  
1x  
Push button  
enabled (default)  
Flash Power 1x,  
Repeat twice  
2x  
3x  
Push button  
disabled  
Flash Power 2x,  
Repeat twice  
Temp. comp  
enabled (default)  
Flash Power 3x,  
Repeat twice  
4x  
Temp. comp  
disabled  
Flash Power 4x,  
Repeat twice  
2 s Hold  
120 second Timeout  
4x  
8x  
Flash Power:  
1x for enabled, Repeat twice  
2x for disabled, Repeat twice  
Toggle push button enable /disable  
(legacy method)  
Restore factory defaults  
All LEDs off for 1 s  
6
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 141958 Rev. E  
®
U-GAGE T30UX Series with Analog Output  
Wiring  
1
3
4
+
10-30V dc  
Wiring Key  
1 = Brown  
2 = White  
3 = Blue  
4-20 mA  
or 0-10V  
2
Remote  
Teach  
0-2V dc  
4 = Black  
Shield*  
Cable and QD hookups are functionally identical. It is recommended that the shield wire be connected to earth ground.  
Shielded cordsets are recommended for all QD models.  
Specifications  
Sensing Range  
Minimum Window Size  
“A” suffix models: 100 mm to 1 m (3.9 in to 39 in)  
“B” suffix models: 200 mm to 2 m (7.8 in to 78 in)  
“C” suffix models: 300 mm to 3 m (11.8 in to 118 in)  
10 mm (0.4 in)  
Adjustments  
Sensing window limits: TEACH-Mode of near and far window limits  
may be set using the push button or remotely via TEACH input.  
Response speed selection: Fast or Slow (see Mode Setup - Response  
Speed on page 2 or Remote Line TEACH on page 5)  
Advanced configuration options: Analog output slope, push button  
enabled/disabled, temperature compensation enabled/disabled (see  
Remote Line TEACH on page 5)  
Ultrasonic Frequency  
“A” suffix models: 224 kHz  
“B” suffix models: 174 kHz  
“C” suffix models: 114 kHz  
Supply Voltage  
10 to 30 V dc (10% maximum ripple) at 40 mA, exclusive of load  
Indicators  
Supply Protection Circuitry  
See Figure 1 on page 1  
Protected against reverse polarity and transient voltages  
Loss of Signal Indication  
Output Configuration  
0 to 10V dc models: Analog output goes to 0V  
4 to 20 mA models: Analog output goes to 3.6 mA  
Analog Output: 0 to 10V dc or 4 to 20 mA, depending on model  
Output Rating  
Construction  
Analog Voltage Output: 2.5 kΩ min. load resistance; Minimum  
supply for a full 10V output is 12V dc (for supply voltages between 10  
and 12, V out max. is at least V supply -2)  
Analog Current Output: 1 kΩ max. at 24V input; max. load  
resistance = (Vcc-4)/0.02Ω  
Housing: PBT polyester  
Push buttons: polyester  
Transducer: epoxy /ceramic composite  
Environmental Rating  
Leakproof design, ratedIEC IP67 (NEMA 6)  
For current output (4-20 mA) models, ideal results are achieved  
when the total load resistance  
R = [(Vin – 4)/0.020]Ω. Example, at Vin = 24V dc, R 1 kΩ (1 watt)  
Connections  
2 m (6.5 ft) or 9 m (30 ft) shielded 4-conductor (with drain) PVC cable,  
150 mm (6 in) PUR Euro-style pigtail (QPMA), or 4-pin integral Euro-  
style connector (Q8)  
Output Protection Circuitry  
Protected against short circuit conditions  
Temperature Effect  
Linearity  
0.02% of distance/°C  
0.25% of distance  
Delay at Power-up  
Resolution  
500 ms  
“A” suffix models: 0.1% of distance (0.5 mm min.)  
“B” suffix models: 0.1% of distance (1.0 mm min.)  
“C” suffix models: 0.1% of distance (1.5 mm min.)  
Output Response Time  
“A” suffix models: 45 ms (fast); 105 ms (slow)  
“B” suffix models: 92 ms (fast); 222 ms (slow)  
“C” suffix models: 135 ms (fast); 318 ms (slow)  
P/N 141958 Rev. E  
www.bannerengineering.com - Tel: +1-763-544-3164  
7
®
U-GAGE T30UX Series with Analog Output  
Operating Conditions  
Required Overcurrent Protection  
Temperature: 40 °C to +70 °C (40 °F to +158 °F)  
Humidity: 95% at +50 °C maximum relative humidity (non-  
condensing)  
WARNING: Electrical connections must be  
made by qualified personnel in accordance  
with local and national electrical codes and  
regulations.  
Vibration and Mechanical Shock  
All models meet Mil. Std. 202F requirements method 201A (vibration:  
10 to 60 Hz max., double amplitude 0.06 in, max acceleration 10G).  
Also meets IEC 947-5-2; 30G 11 ms duration, half sine wave  
Overcurrent protection is required to be provided by end product  
application per the supplied table.  
Overcurrent protection may be provided with external fusing or via  
Current Limiting, Class 2 Power Supply.  
Certifications  
Supply wiring leads < 24 AWG shall not be spliced.  
For additional product support, go to http://  
www.bannerengineering.com.  
Supply Wiring (AWG)  
Required Overcurrent Protection (Amps)  
20  
22  
24  
26  
28  
30  
5.0  
3.0  
2.0  
1.0  
0.8  
0.5  
Application Note  
The temperature warmup drift upon power-up is less than 1% of the  
sensing distance.  
Performance Curves  
With Plate Target (Typical)  
1-Meter Models  
2-Meter Models  
3-Meter Models  
200 mm  
150 mm  
100 mm  
50 mm  
0
8.0"  
6.0"  
4.0"  
2.0"  
0
400 mm  
300 mm  
200 mm  
100 mm  
0
16.0"  
12.0"  
8.0"  
400 mm  
16.0"  
12.0"  
8.0"  
4.0"  
0
300 mm  
200 mm  
100 mm  
0
100 x 100 mm  
100 x 100 mm  
4.0"  
100 x 100 mm  
0
Width  
Width  
Width  
100 mm  
200 mm  
300 mm  
400 mm  
4.0"  
8.0"  
12.0"  
100 mm  
200 mm  
300 mm  
400 mm  
4.0"  
8.0"  
12.0"  
16.0"  
50 mm  
100 mm  
150 mm  
200 mm  
2.0"  
4.0"  
6.0"  
8.0"  
16.0"  
0
400 mm  
(16.0")  
800 mm 1200 mm 1600 mm 2000 mm  
0
600 mm 1200 mm 1800 mm 2400 mm 3000 mm  
(24.0") (48.0") (72.0") (96.0") (120.0")  
Distance  
0
200 mm  
(8.0")  
400 mm  
(16.0")  
600 mm  
(24.0")  
800 mm 1000 mm  
(32.0")  
(32.0")  
(48.0")  
(64.0"  
(80.0")  
(40.0")  
Distance  
Distance  
With Rod Target (Typical)  
1-Meter Models  
2-Meter Models  
3-Meter Models  
200 mm  
150 mm  
100 mm  
8.0"  
400 mm  
300 mm  
200 mm  
100 mm  
0
16.0"  
400 mm  
300 mm  
200 mm  
100 mm  
0
16.0"  
12.0"  
8.0"  
4.0"  
0
12.0"  
8.0"  
4.0"  
0
6.0"  
4.0"  
2.0"  
0
25 mm Rod  
25 mm Rod  
25 mm Rod  
50 mm  
0
10 mm Rod  
10 mm Rod  
Width  
Width  
Width  
10 mm Rod  
100 mm  
200 mm  
300 mm  
400 mm  
4.0"  
8.0"  
12.0"  
16.0"  
100 mm  
200 mm  
300 mm  
400 mm  
4.0"  
8.0"  
12.0"  
16.0"  
50 mm  
100 mm  
150 mm  
200 mm  
2.0"  
4.0"  
6.0"  
8.0"  
0
400 mm  
(16.0")  
800 mm 1200 mm 1600 mm 2000 mm  
(32.0") (48.0") (64.0") (80.0")  
Distance  
0
600 mm 1200 mm 1800 mm 2400 mm 3000 mm  
(24.0") (48.0") (72.0") (96.0") (120.0")  
Distance  
0
200 mm  
(8.0")  
400 mm  
(16.0")  
600 mm  
(24.0")  
800 mm 1000 mm  
(32.0") (40.0")  
Distance  
8
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 141958 Rev. E  
®
U-GAGE T30UX Series with Analog Output  
Maximum Target Rotation Angle  
30  
1 meter Target Rotation  
2 meter Target Rotation  
3 meter Target Rotation  
20  
10  
0
Target Rotation  
(Degrees)  
10  
20  
30  
0
500 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm  
(20.0")  
(40.0")  
(60.0")  
(80.0")  
(100.0")  
(120.0")  
Distance  
Dimensions  
45.0  
[1.77"]  
22.5  
[0.89"]  
Ø40.2  
[1.58"]  
51.1  
[2.01"]  
63.6  
[2.50"]  
23.4  
[0.92"]  
M12 x 1  
M30 x 1.5  
Max. Torque 2.3 Nm (20 in-lbs.)  
ø 15  
[0.6"]  
Locknut (included with all models)  
10  
Washer (included with all models)  
M30 x 1.5  
Ø40  
[1.6"]  
[0.4"]  
Ø39.6  
[1.56"]  
1.6  
[0.06"]  
Ø30  
[1.2"]  
3x 36.1  
[1.42"]  
5
[0.2"]  
P/N 141958 Rev. E  
www.bannerengineering.com - Tel: +1-763-544-3164  
9
®
U-GAGE T30UX Series with Analog Output  
Accessories  
Quick-Disconnect Cables  
4-Pin Threaded M12/Euro-Style Cordsets with Shield  
Model  
Length  
Style  
Dimensions  
Pinout (Female)  
MQDEC2-406  
MQDEC2-415  
1.83 m (6 ft)  
4.57 m (15 ft)  
44 Typ.  
Straight  
M12 x 1  
MQDEC2-430  
9.14 m (30 ft)  
2
3
ø 14.5  
1
4
MQDEC2-406RA  
MQDEC2-415RA  
1.83 m (6 ft)  
4.57 m (15 ft)  
32 Typ.  
[1.26"]  
1 = Brown  
2 = White  
3 = Blue  
30 Typ.  
[1.18"]  
Right-Angle  
4 = Black  
MQDEC2-430RA  
9.14 m (30 ft)  
M12 x 1  
ø 14.5 [0.57"]  
Brackets  
All measurements are in mm.  
SMB30A  
SMB1815SF  
45  
51  
Right-angle bracket with  
curved slot for versatile  
orientation  
Clearance for M6 (¼ in)  
hardware  
Mounting hole for 30 mm  
sensor  
12-ga. stainless steel  
Swivel with set screws  
for mounting sensors by  
the cable hub  
B
C
B
61  
Black reinforced  
thermoplastic polyester  
Stainless steel swivel  
locking hardware and  
hex wrench included  
39  
A
69  
A
25  
Hole center spacing: A to B=40  
Hole size: A=ø 6.3, B= 27.1 x 6.3, C=ø 30.5  
Hole center spacing: A = 36.0  
Hole size: A = ø 5.0, B = ø 15.0  
SMB30FA  
SMB30SC  
67  
83.2  
Swivel bracket with tilt and  
pan movement for precise  
adjustment  
Mounting hole for 30 mm  
sensor  
12-ga. 304 stainless steel  
Easy sensor mounting to  
extrude rail T-slot  
Swivel bracket with 30 mm  
mounting hole for sensor  
Black reinforced  
B
58  
thermoplastic polyester  
Stainless steel mounting and  
swivel locking hardware  
included  
68.9  
36.3  
B
29  
A
A
Metric and inch size bolt  
available  
Hole center spacing: A=ø 50.8  
Hole size: A=ø 7.0, B=ø 30.0  
Bolt thread: SMB30FA, A= 3/8 - 16 x 2 in; SMB30FAM10, A= M10 -  
1.5 x 50  
Hole size: B= ø 30.1  
10  
www.bannerengineering.com - Tel: +1-763-544-3164  
P/N 141958 Rev. E  
®
U-GAGE T30UX Series with Analog Output  
Banner Engineering Corp. Limited Warranty  
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp.  
will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty  
period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.  
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION,  
ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE  
OF DEALING OR TRADE USAGE.  
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE  
LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL,  
CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER  
ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.  
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product  
previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection  
applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval  
by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product  
specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most  
recent version of any documentation, refer to: www.bannerengineering.com.  
©
Banner Engineering Corp. All rights reserved  

相关型号:

T30W1NR-F

High Voltage Paper-Film/Foil Capacitors
CDE

T30W6NR-F

High Voltage Paper-Film/Foil Capacitors
CDE

T30XRYNQ

DC-Operated LED Indicators with Two or Three Colors
ETC

T30XRYPQ

DC-Operated LED Indicators with Two or Three Colors
ETC

T31-A230X

SURGE ARRESTER 3-electrode arrester
EPCOS

T31-A350X

SURGE ARRESTER 3-electrode arrester
EPCOS

T310042300J0G

Barrier Strip Terminal Block
AMPHENOL

T310045100J0G

Barrier Strip Terminal Block,
AMPHENOL

T310046300J0G

Barrier Strip Terminal Block
AMPHENOL

T310048300J0G

Barrier Strip Terminal Block
AMPHENOL

T310048400J0G

Barrier Strip Terminal Block
AMPHENOL

T310049400J0G

Barrier Strip Terminal Block
AMPHENOL