TL50A [BANNER]
TL50A Audible Indicators;型号: | TL50A |
厂家: | Banner Engineering |
描述: | TL50A Audible Indicators |
文件: | 总5页 (文件大小:511K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
TL50A Audible Indicators
Datasheet
General-Purpose Audible Indicators
•
•
•
•
•
Rugged, cost-effective and easy to install
Compact devices are self-contained, no controller needed
Immune to EMI and RFI interference
Choose IEC IP50 or Sealed IEC IP67 model, black or light gray housing
12 V dc to 30 V dc, or 24 V ac operation
Models
1
2
Standard Audible Models
Connection
Inputs
TL50AQ
Integral 4-pin M12/Euro-style quick disconnect
Bimodal (NPN or PNP)
1
Sealed Audible Models
2
Connection
Inputs
Continuous
TL50ALSQ
Pulsed at 1.6 Hz
TL50ALS3Q
Staccato
TL50ALS4Q
Integral 4-pin M12/Euro-style quick disconnect
Bimodal (NPN or PNP)
1
Omni-Directional Sealed Audible Models
Pulsed at 1.6 Hz
2
Connection
Inputs
Continuous
TL50AOSQ
Staccato
TL50AOS4Q
TL50AOS3Q
Integral 4-pin M12/Euro-style quick disconnect
Bimodal (NPN or PNP)
1
Omni-Directional Sealed Audible Models with Intensity Adjustment
2
Connection
Inputs
Continuous
TL50AOSIQ
Pulsed at 1.6 Hz
Staccato
TL50AOS4IQ
TL50AOS3IQ
Integral 4-pin M12/Euro-style quick disconnect
Bimodal (NPN or PNP)
Wiring Diagrams
PNP Input
NPN Input
Key
1 = Brown
2 = White
3 = Blue
4 = Black
3
4
3
4
12-30V dc
or 24V ac
12-30V dc
or 24V ac
A
A
1
2
1
2
No Connection
No Connection
No Connection
No Connection
1
2
Models with black housing are listed. For gray housing, add the suffix "C" at the end of the cabled model number or before the "Q" in quick disconnect model numbers. For
example, TL50AC or TL50ACQ.
Integral quick disconnect models are listed.
•
•
•
To order the 150 mm (6 in) PVC cable model with a M12/Euro-style quick disconnect, replace the suffix "Q" with "QP" in the model number. For example, TL50AQP.
To order the 2 m (6.5 ft) PVC cable model, omit the suffix "Q" in the model number. For example, TL50A.
Models with a quick disconnect require a mating cordset.
Original Document
155019 Rev. J
7 May 2019
155019
TL50A Audible Indicators
Specifications
Supply Voltage and Current
Required Overcurrent Protection
WARNING: Electrical connections must be made by
qualified personnel in accordance with local and
12 V dc to 30 V dc; or 24 V ac ( 3 V ac) at 50 Hz to 60 Hz
Standard Audible Alarm: 25 mA maximum current
Sealed Audible Alarm: 35 mA maximum current
Omni-Directional Sealed Audible Alarm: 45 mA maximum current
national electrical codes and regulations.
Audible Alarm
Standard Audible Alarm: 2.7 kHz 500 Hz oscillation frequency; maximum intensity 92
dB at 1 m (3.3 ft) (typical)
Sealed Audible Alarm: 2.9 kHz 250 Hz oscillation frequency; maximum intensity 94
dB at 1m (3.3 ft) (typical)
Overcurrent protection is required to be provided by end product application per the
supplied table.
Overcurrent protection may be provided with external fusing or via Current Limiting,
Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to www.bannerengineering.com.
Omni-Directional Sealed Audible Alarm: 2.1 kHz 250 Hz oscillation frequency;
maximum intensity 99 dB at 1 m (3.3 ft) (typical)
Audible Adjustment
Supply Wiring (AWG)
Required Overcurrent Protection (Amps)
Standard Audible Alarm: Unscrew the cover (up to 1.5 turns maximum) to adjust the
audible intensity (do not exceed 1.5 turns or the cover may detach during operation).
For maximum intensity, rotate the center plug 180° counterclockwise to remove it.
Sealed Audible Alarm and Omni-Directional Sealed Audible Alarm with Intensity
Adjustment: Rotate the front cover until the desired intensity is reached.
Typical Reduction in Sound Intensity with Audible Adjustment (maximum to minimum):
20
22
24
26
28
30
5.0
3.0
2.0
1.0
0.8
0.5
•
•
•
Standard Audible Alarm: 30 dB
Sealed Audible Alarm: 20 dB
Omni-Directional Sealed Audible Alarm: 12 dB
Connections
Integral 4-pin M12/Euro-style quick disconnect, 150 mm (6 in) PVC cable with a M12/
Euro-style quick disconnect, or 2 m (6.5 ft) integral PVC cable, depending on model
Models with a quick disconnect require a mating cordset
Certifications
Vibration and Mechanical Shock
Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 1.0 mm amplitude, 5
minutes sweep, 30 minutes dwell)
Meets IEC 60068-2-27 requirements (Shock: 30G 11 ms duration, half sine wave)
Operating Conditions
–20 °C to +50 °C (–4 °F to +122 °F)
95% at +50 °C maximum relative humidity (non-condensing)
Environmental Rating
UL Type 4X Indoor and UL Type 13
Standard models: IEC IP50
Sealed models: IEC IP67
Dimensions
Standard Audible Models
Sealed Audible Models
Omni-Directional Models
93.4
[3.68]
107.5
[4.23]
26.9
[1.06]
111
[4.37]
2
▲
19
[0.75]
19.0
[0.75]
M30 X 1.5
19
[0.75]
M30 X 1.5-6 g
M30 X 1.5-6 g
45.0
[1.77]
M12 X 1-6 g
ø45
[1.77]
45
[1.77]
ø50
[1.97]
1/2-14 NPSM
ø50
[1.97]
1/2-14 NPSM
1/2-14 NPSM
ø50
[1.97]
All measurements are listed in millimeters [inches], unless noted otherwise.
2
www.bannerengineering.com - Tel: + 1 888 373 6767
P/N 155019 Rev. J
TL50A Audible Indicators
Accessories
Cordsets
4-Pin Threaded M12/Euro-Style Cordsets—Single Ended
Model
Length
Style
Dimensions
Pinout (Female)
MQDC-406
MQDC-415
MQDC-430
1.83 m (6 ft)
4.57 m (15 ft)
9.14 m (30 ft)
44 Typ.
Straight
M12 x 1
MQDC-450
15.2 m (50 ft)
2
3
ø 14.5
1
4
MQDC-406RA
MQDC-415RA
MQDC-430RA
1.83 m (6 ft)
4.57 m (15 ft)
9.14 m (30 ft)
32 Typ.
[1.26"]
1 = Brown
2 = White
3 = Blue
30 Typ.
[1.18"]
Right-Angle
4 = Black
MQDC-450RA
15.2 m (50 ft)
M12 x 1
ø 14.5 [0.57"]
Mounting Brackets
All measurements are listed in millimeters [inches], unless noted otherwise.
83.2
SMB30A
•
SMB30FA
•
45
Right-angle bracket with curved slot
for versatile orientation
Clearance for M6 (¼ in) hardware
Mounting hole for 30 mm sensor
12-ga. stainless steel
Swivel bracket with tilt and pan
movement for precise adjustment
Mounting hole for 30 mm sensor
12-ga. 304 stainless steel
Easy sensor mounting to extrude rail
T-slot
Metric and inch size bolt available
C
•
•
•
•
•
•
61
B
68.9
36.3
B
•
A
A
69
Hole center spacing: A to B=40
Hole size: A=ø 6.3, B= 27.1 x 6.3, C=ø 30.5
Bolt thread: SMB30FA, A= 3/8 - 16 x 2 in; SMB30FAM10, A= M10 - 1.5 x 50
Hole size: B= ø 30.1
SMB30MM
SMBAMS30P
45
•
12-ga. stainless steel bracket with
curved mounting slots for versatile
orientation
Clearance for M6 (¼ in) hardware
Mounting hole for 30 mm sensor
•
•
•
•
Flat SMBAMS series bracket
57
70
30 mm hole for mounting sensors
Articulation slots for 90°+ rotation
12-ga. 300 series stainless steel
C
•
•
C
A
93
57
B
B
A
Hole center spacing: A = 51, A to B = 25.4
Hole size: A = 42.6 x 7, B = ø 6.4, C = ø 30.1
Hole center spacing: A=26.0, A to B=13.0
Hole size: A=26.8 x 7.0, B=ø 6.5, C=ø 31.0
SMBAMS30RA
SMB30SC
67
45
•
•
•
•
Right-angle SMBAMS series bracket
30 mm hole for mounting sensors
Articulation slots for 90°+ rotation
12-ga. (2.6 mm) cold-rolled steel
•
•
•
Swivel bracket with 30 mm mounting
hole for sensor
Black reinforced thermoplastic
polyester
Stainless steel mounting and swivel
locking hardware included
B
C
53
58
A
B
48
29
A
Hole center spacing: A=26.0, A to B=13.0
Hole size: A=26.8 x 7.0, B=ø 6.5, C=ø 31.0
Hole center spacing: A=ø 50.8
Hole size: A=ø 7.0, B=ø 30.0
P/N 155019 Rev. J
www.bannerengineering.com - Tel: + 1 888 373 6767
3
TL50A Audible Indicators
LMBE12RA35
LMBE12RA45
55
35
65
•
Direct mounting of stand-off pipe, with common
•
Direct mounting of stand-off pipe, with common
45
bracket type
38.25
bracket type
38.25
•
•
•
Zinc-plated steel
•
•
•
Zinc-plated steel
1/2-14 NPSM nut
1/2-14 NPSM nut
Mounting distance from the wall to the center of
the 1/2-14 NPSM nut is 35 mm
Mounting distance from the wall to the center of
the 1/2-14 NPSM nut is 45 mm
1/2 - 14
NPSM NUT
1/2 - 14
NPSM NUT
57
81
Hole center spacing: 20.0
Hole center spacing: 35.0
2X Ø9
2X Ø11
Pipe Mounting Flange
Pipe Mounting Flange
Model
Features
Construction
54
1/2-14
NPSM
4x ø5.5
•
•
Elevated-use stand-off pipes (½ in, NPSM/
DN15)
Die-cast zinc base with black
paint
SA-F12
ø28
ø70
M5 mounting hardware and nitrile gasket
included
10
ø40
•
•
Elevated-use stand-off pipes (½ in, NPSM/
1/2-14 NPSM
2 x 120°
DN15)
SA-F12-3
Black Polycarbonate
M4 mounting hardware and nitrile blend gasket
included
29
8.77
ø60
LMB Sealed Right-Angle Bracket
Model
Description
Construction
LMB30RA
Black polycarbonate
Direct-Mount Models: Bracket kit with base, 30 mm adapter,
set screw, fasteners, O-rings, and gaskets.
LMB30RAC
LMBE12RA
LMBE12RAC
Gray polycarbonate
Black polycarbonate
Gray polycarbonate
Pipe-Mount Models: Bracket kit with base, ½-14 pipe adapter,
set screw, fasteners, O-rings, and gaskets. For use with
stand-off pipe (listed and sold separately).
Elevated Mount System
Model
Features
Components
SA-M30TE12 - Black Acetal
•
•
•
Streamlined black acetal or white UHMW stand-off pipe
adapter/cover
Connects between 30 mm light base and ½ in. NPSM/DN15
SA-M30TE12C - White UHMW
pipe
Mounting hardware included
Polished 304 Stainless Steel Black Anodized Aluminum
Clear Anodized Aluminum
SOP-E12-150SS
150 mm (6 in) long
SOP-E12-150A
150 mm (6 in) long
SOP-E12-150AC
150 mm (6 in) long
•
•
Elevated-use stand-off pipe (½ in. NPSM/DN15)
Polished 304 stainless steel, black anodized aluminum, or
clear anodized aluminum surface
SOP-E12-300SS
300 mm (12 in) long
SOP-E12-300A
300 mm (12 in) long
SOP-E12-300AC
300 mm (12 in) long
•
•
½ in. NPT thread at both ends
Compatible with most industrial environments
SOP-E12-900SS
900 mm (36 in) long
SOP-E12-900A
900 mm (36 in) long
SOP-E12-900AC
900 mm (36 in) long
SA-E12M30 - Black Acetal
•
•
•
Streamlined black acetal or white UHMW mounting base
adapter/cover
Connects between ½ in. NPSM/DN15 pipe and 30 mm
(1-3/16 in) drilled hole
SA-E12M30C - White UHMW
Mounting hardware included
4
www.bannerengineering.com - Tel: + 1 888 373 6767
P/N 155019 Rev. J
TL50A Audible Indicators
Banner Engineering Corp. Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge,
any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the
improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER
PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR
FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner
Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such
purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this
document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is
provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com.
For patent information, see www.bannerengineering.com/patents.
©
Banner Engineering Corp. All rights reserved
相关型号:
TL50ALS3Q
TL50A Audible IndicatorsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER
TL50ALS4Q
TL50A Audible IndicatorsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER
TL50ALSQ
TL50A Audible IndicatorsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER
TL50AOS3IQ
TL50A Audible IndicatorsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER
TL50AOS4IQ
TL50A Audible IndicatorsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER
TL50AOSIQ
TL50A Audible IndicatorsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER
TL50AQ
TL50A Audible IndicatorsWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER
TL50BGYRALS3Q
TL50 Tower LightWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER
TL50BGYRALS4Q
TL50 Tower LightWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER
TL50BGYRALSQ
TL50 Tower LightWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER
TL50BGYRAOS3IQ
TL50 Tower LightWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER
TL50BGYRAOS3Q
TL50 Tower LightWarning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER
©2020 ICPDF网 联系我们和版权申明