VTBN6RQ [BANNER]
VTB Pick-to-Light Optical Touch Button;型号: | VTBN6RQ |
厂家: | Banner Engineering |
描述: | VTB Pick-to-Light Optical Touch Button |
文件: | 总7页 (文件大小:440K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
VTB Pick-to-Light Optical Touch Button
Datasheet
Ergonomic optical touch button for pick-to-light applications
•
•
Microcontroller-based photoelectric touch buttons
A cost-effective and easy-to-install alternative to capacitive touch switches and
mechanical push buttons for errorproofing and parts-verification applications
•
•
Ergonomically designed to eliminate hand, wrist, and arm stresses associated
with repeated switch operation; requires no physical pressure to operate
Illuminated base provides a bright, easy-to-see job light in one or two colors,
depending on model
•
•
•
•
LED power and output indicators
NPN or PNP output, depending on model
Immune to ambient light, EMI and RFI interference
High excess gain cuts through heavy airborne contamination to function in almost
any environment; optional protective field cover available
•
12 to 30 V dc operation
One-Color Job Light Models
Job Light Color
Red
Cable*
Upper Housing
Polysulfone
Output Type
Job Light Input
Green
Blue
VTBN6
VTBN6R
VTBN6B
VTBN6BQ
VTBN6BL
VTBN6BLQ
VTBP6B
2 m 4-wire cable
4-pin Euro QD
2 m 4-wire cable
4-pin Euro QD
2 m 4-wire cable
4-pin Euro QD
2 m 4-wire cable
4-pin Euro QD
VTBN6Q
VTBN6L
VTBN6LQ
VTBP6
VTBN6RQ
VTBN6RL
VTBN6RLQ
VTBP6R
NPN
0 V dc
Polycarbonate
Polysulfone
VTBP6Q
VTBP6L
VTBP6LQ
VTBP6RQ
VTBP6RL
VTBP6RLQ
VTBP6BQ
VTBP6BL
VTBP6BLQ
PNP
+4 to 30 V dc
Polycarbonate
Two-Color Job Light Models
Green and Red (see Wiring)
VTBN6GR
Cable*
Upper Housing
Output Type
Job Light Input
2 m 5-wire cable
5-pin Euro QD
2 m 5-wire cable
5-pin Euro QD
2 m 5-wire cable
5-pin Euro QD
2 m 5-wire cable
5-pin Euro QD
Polysulfone
VTBN6GRQ
NPN
0 V dc
VTBN6GRL
Polycarbonate
Polysulfone
VTBN6GRLQ
VTBP6GR
VTBP6GRQ
PNP
+4 to 30V dc
VTBP6GRL
Polycarbonate
VTBP6GRLQ
To order the 9 m (30 ft) cable models, add the suffix "W/30" to the cabled model number. (For example, VTBN6 W/30.)
Models with a quick disconnect (QD) connector require a mating cable. (See Quick Disconnect (QD) Cables on page 5).
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to
serious injury or death. This device does not include the self-checking redundant circuitry necessary
to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an
energized or de-energized sensor output condition.
Original Document
67570 Rev. E
16 May 2016
67570
VTB Pick-to-Light Optical Touch Button
Overview
Banner VTB Series touch buttons are ergonomically designed to eliminate the hand, wrist, and arm stresses associated
with mechanical push buttons. They require no physical pressure to operate. LED indicators light when power is on and
outputs are activated.
The solid-state output interfaces to a system controller, which is pre-programmed for a specific sequence of tasks.
Mounted in or near each bin in an assembler’s work station, the sensor job light signals the assembler which bins contain
items to be picked in a given operation and in what order they should be picked.
As the assembler takes a part in sequence, then reaches a finger into the yoke of the corresponding Touch Button, the
sensor senses that the part was removed and it sends an output signal to the controller. The controller then verifies if the
correct part was taken and may respond by turning that job light OFF, activating the job light of the next bin in the
sequence.
If multiple parts are to be removed from one bin, the job light may remain ON until the appropriate number of signals is
returned to the controller. If an incorrect part is selected, the control system may be wired to signal an alarm for the
assembler and/or a supervisor, or it may be programmed to interpret the action as a call for parts.
All models are immune to EMI, RFI, and ambient light interference. VTBs have either a black polysulfone or red
polycarbonate upper housing (depending on model) and a translucent white polycarbonate base. Environmental
considerations for use of the two upper housing types differ; see specifications. The entire base section lights to provide a
bright job light where a task is to be performed. The 30 mm threaded base on all models provides easy mounting.
Indicators
Output
Conducting
LED
Power ON/OFF (red):
Steady ON when power is applied
Output Conducting (red):
Switch
"Touch Area"
Steady ON when button is activated
OFF when button is not activated
Job Light:
Steady ON or flashing* when a task is to be
performed
Power ON/OFF
LED
* Flashing job light is dependent on wiring. Color is
dependent on model and wiring.
Black Polysulfone
or Red Polycarbonate
Translucent White
Polycarbonate
Base/Job Light
Installation
Consider ergonomic principles to avoid unnecessary fatigue in the installation of the hand controls. Install the touch
buttons at a height and in a location that will be comfortable for the user.
The following figure shows two methods for mounting the touch buttons, to prevent accidental switch actuation. When
mounting them on top of the control bar, the protective field covers should be in place, as shown; or for added protection,
mount the touch buttons sideways under and/or behind a protective hood, rather than on top of the bar, without using the
field covers. This side mount prevents an object from being left in the path of the beam. In addition, shields, covers, rings,
collars, dividers, or similar protection may be used to prevent accidental switch actuation.
2
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 67570 Rev. E
VTB Pick-to-Light Optical Touch Button
Figure 1. Protect VTB touch buttons to prevent defeat or inadvertent actuation
CAUTION: Install Hand Controls to Prevent Accidental Actuation
Total protection for the two-hand control system from defeat is not possible. However, the user is
required by U.S. and International standards to arrange and protect hand controls to
minimize the possibility of defeat or accidental actuation.
CAUTION: Hand Controls
The environment in which hand controls are installed must not adversely affect the means of
actuation. Severe contamination or other environmental influences may cause slow response or false
On conditions of mechanical or ergonomic buttons. This may result in exposure to a hazard.
Wiring
Single-color models may be wired for either a solid or flashing job light. The wiring of two-color models determines the job
light. Color flashing job light is not available. Cabled model wiring shown. Cabled and QD model wiring is functionally
identical.
•
•
For solid color, use the standard wiring diagram.
For flashing (2 Hz), use the alternate wiring diagrams.
One-Color Job Light, NPN
(Sinking) Output Models
One-Color Job Light, PNP
(Sourcing) Output Models
Two-Color Job Light Models
NPN (Sinking) Output Models
Solid Job Light
Solid Job Light
bn
+
bn
bn
+
12-30V dc
bu
bk
wh
gy
+
-
12-30V dc
bu
bk
wh
12-30 V dc
bu
bk
wh
-
-
Load
Green Job Light Enable — 0V dc
Red Job Light Enable — 0V dc
Load
Load
Job Light Enable
+4-30 V dc
Job Light Enable
0V dc
Flashing Job Light
Flashing Job Light
PNP (Sourcing) Output Models
bn
bn
-
+
bn
12-30 V dc
bu
12-30V dc
-
bu
bk
wh
-
+
12-30 V dc
bu
bk
wh
bk
wh
gy
+
Load
Load
Green Job Light Enable — +4-30 V dc
Red Job Light Enable — +4-30 V dc
Load
Job Light Enable
0V dc
Job Light Enable
+4-30 V dc
P/N 67570 Rev. E
www.bannerengineering.com - Tel: +1-763-544-3164
3
VTB Pick-to-Light Optical Touch Button
Specifications
Supply Voltage and Current
Indicators
2 green LED indicators: Power ON and Output Conducting
One-color job light models: Less than 120 mA max current at 12 V dc
and less than 70 mA max current at 30 V dc (exclusive of load)
Two-color job light models: Less than 67 mA max current at 12 V dc;
less than 40 mA max current at 24 V dc; and less than 35 mA max
current at 30 V dc (exclusive of load)
Base lights green, red or blue (depending on model and wiring) as a
job light when input line is enabled. One-color models may be wired for
flashing, rather than solid color operation.
Connections
Supply Protection Circuitry
PVC-jacketed 2 m (6.5 ft) cables or 4-pin M12/Euro-style QD fitting,
depending on model; integral 9 m (30 ft) cables are also available.
Accessory QD cables required for QD models.
Protected against reverse polarity and transient voltages (fast-transient
and overvoltage)
Output Configuration
Ambient Light Immunity
1 current sinking (NPN) open collector transistor or 1 current sourcing
(PNP) open collector transistor, depending on model
Up to 120,000 lux (direct sunlight)
EMI/RFI Immunity
Output Rating
Immune to EMI and RFI noise sources, per IEC 947-5-2
Max. load: 150 mA
On-state saturation voltage: < 1.5 V at 150 mA
Off-state leakage current: < 10 μA
Construction
Totally encapsulated, non-metallic enclosure. Black polysulfone or red
polycarbonate upper housing (see Application Note below); translucent
white polycarbonate base. Electronics fully epoxy-encapsulated.
Output Protection Circuitry
All models protected against false pulse on power-up (outputs held OFF
for 1 second at power-up), overload and short-circuits.
Output Response Time
100 milliseconds ON/OFF
Operating Conditions
−20 °C to +50 °C (−4 °F to +122 °F)
90% at +55 °C maximum relative humidity (non-condensing)
Required Overcurrent Protection
WARNING: Electrical connections must be
made by qualified personnel in accordance
with local and national electrical codes and
regulations.
Environmental Rating
Meets NEMA standards 1, 3, 4, 4X, 12, and 13; IEC IP66
Application Notes
Environmental considerations for models with polysulfone upper
housings: The polysulfone upper housing will become brittle with
prolonged exposure to outdoor sunlight. Window glass effectively filters
longer wavelength ultraviolet light and provides excellent protection
from sunlight. Avoid contact with strong alkalis. Clean periodically
using mild soap solution and a soft cloth.
Environmental considerations for models with polycarbonate upper
housings: Avoid prolonged exposure to hot water and moist high
temperature environments above 66° C (150° F). Avoid contact with
aromatic hydrocarbons (such as xylene and toluene), halogenated
hydrocarbons and strong alkalis. Clean periodically using mild soap
solution and a soft cloth.
Overcurrent protection is required to be provided by end product
application per the supplied table.
Overcurrent protection may be provided with external fusing or via
Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to http://
www.bannerengineering.com.
Supply Wiring
Required Overcurrent Protection
20
22
24
26
28
30
5.0 Amps
3.0 Amps
2.0 Amps
1.0 Amps
0.8 Amps
0.5 Amps
Certifications
4
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 67570 Rev. E
VTB Pick-to-Light Optical Touch Button
Dimensions
43.2 mm
[1.70"]
59.9 mm
[2.36"]
27.9 mm
[1.10"]
35.0 mm
[1.38"]
VTBP6
VTBP6
22.1 mm
[0.87"]
22.1 mm
[0.87"]
15.2 mm
[0.60"]
NPSM
Internal Threads
M30 External Threads
Jam Nut, Lock Ring, and
Seal Washers are Supplied
max. torque 4.5 N·m [40 lbf·in]
Accessories
Quick Disconnect (QD) Cables
Use the 4-pin Euro-style cordsets with the one-color job light models.
4-Pin Threaded M12/Euro-Style Cordsets
Model
Length
Style
Dimensions
Pinout (Female)
MQDC-406
MQDC-415
MQDC-430
1.83 m (6 ft)
4.57 m (15 ft)
9.14 m (30 ft)
44 Typ.
Straight
M12 x 1
2
3
1
4
ø 14.5
MQDC-450
15.2 m (50 ft)
MQDC-406RA
MQDC-415RA
MQDC-430RA
1.83 m (6 ft)
4.57 m (15 ft)
9.14 m (30 ft)
32 Typ.
[1.26"]
1 = Brown
2 = White
3 = Blue
30 Typ.
[1.18"]
Right-Angle
4 = Black
MQDC-450RA
15.2 m (50 ft)
M12 x 1
ø 14.5 [0.57"]
Use the 5-pin Euro-style cordsets with the two-color job light models.
P/N 67570 Rev. E
www.bannerengineering.com - Tel: +1-763-544-3164
5
VTB Pick-to-Light Optical Touch Button
5-Pin Threaded M12/Euro-Style Cordsets—Single Ended
Model
Length
Style
Dimensions
Pinout (Female)
MQDC1-501.5
MQDC1-506
MQDC1-515
0.50 m (1.5 ft)
1.83 m (6 ft)
4.57 m (15 ft)
44 Typ.
Straight
M12 x 1
2
ø 14.5
MQDC1-530
9.14 m (30 ft)
1
4
3
MQDC1-506RA
MQDC1-515RA
1.83 m (6 ft)
4.57 m (15 ft)
5
32 Typ.
[1.26"]
1 = Brown
2 = White
3 = Blue
30 Typ.
[1.18"]
Right-Angle
4 = Black
5 = Gray
MQDC1-530RA
9.14 m (30 ft)
M12 x 1
ø 14.5 [0.57"]
Brackets
SMB30A
SMB30MM
45
•
Right-angle bracket with
curved slot for versatile
•
12-ga. stainless steel bracket
with curved mounting slots
for versatile orientation
57
70
C
B
orientation
C
61
57
•
•
•
Clearance for M6 (¼ in)
hardware
•
•
Clearance for M6 (¼ in)
hardware
B
A
A
Mounting hole for 30 mm
sensor
Mounting hole for 30 mm
sensor
69
12-ga. stainless steel
Hole center spacing: A = 51, A to B = 25.4
Hole size: A = 42.6 x 7, B = ø 6.4, C = ø 30.1
Hole center spacing: A to B=40
Hole size: A=ø 6.3, B= 27.1 x 6.3, C=ø 30.5
SMBAMS30P
SMBAMS30RA
45
•
•
Flat SMBAMS series bracket
•
•
•
•
Right-angle SMBAMS series
bracket
45
C
30 mm hole for mounting
sensors
C
A
30 mm hole for mounting
sensors
53
93
A
•
•
Articulation slots for 90°+
rotation
B
B
Articulation slots for 90°+
rotation
48
12-ga. 300 series stainless
steel
12-ga. (2.6 mm) cold-rolled
steel
Hole center spacing: A=26.0, A to B=13.0
Hole size: A=26.8 x 7.0, B=ø 6.5, C=ø 31.0
Hole center spacing: A=26.0, A to B=13.0
Hole size: A=26.8 x 7.0, B=ø 6.5, C=ø 31.0
6
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 67570 Rev. E
VTB Pick-to-Light Optical Touch Button
SMB30SC
SMB30FA
67
•
•
•
Swivel bracket with 30 mm
•
Swivel bracket with tilt and
B
83.2
mounting hole for sensor
pan movement for precise
adjustment
58
Black reinforced
thermoplastic polyester
•
Mounting hole for 30 mm
sensor
Stainless steel mounting and
swivel locking hardware
included
68.9
36.3
B
29
•
•
12-ga. 304 stainless steel
A
A
Easy sensor mounting to
extrude rail T-slot
Hole center spacing: A=ø 50.8
Hole size: A=ø 7.0, B=ø 30.0
•
Metric and inch size bolt
available
Bolt thread: SMB30FA, A= 3/8 - 16 x 2 in; SMB30FAM10, A= M10 -
1.5 x 50
Hole size: B= ø 30.1
Field Covers
Field covers are designed to prevent inadvertent activation of optical touch buttons by objects that accidentally block the
sensing beam. Field covers are constructed of rugged polypropylene and are highly resistant to abrasion and to damage by
most chemicals. A variety of colors is available, allowing color-coding when multiple touch buttons are used. Note that
when a field cover is used, it also blocks a portion of the job light.
Model
Description
Black cover
Green cover
Red cover
OTC-1-BK
OTC-1-GN
OTC-1-RD
OTC-1-YW
OTC Series
Field Cover
74.0 mm
(2.9")
Yellow cover
51.0 mm
(2.0")
69.0 mm
(2.7")
Banner Engineering Corp Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following
the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture
which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty
does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR
IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR
TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO
EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR
ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR
SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE
PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY,
NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any
obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp.
www.bannerengineering.com - Tel: +1-763-544-3164
相关型号: