WLB32ZC850..QM [BANNER]
WLB32 Industrial LED Light Bar (AC);型号: | WLB32ZC850..QM |
厂家: | Banner Engineering |
描述: | WLB32 Industrial LED Light Bar (AC) |
文件: | 总8页 (文件大小:2163K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
WLB32 Industrial LED Light Bar (AC)
Datasheet
Banner’s WLB32 is an ultra-bright LED fixture that features an even light
output for a no glare ‘glow’. Suitable for a variety of environments and
applications, including work stations, machine lighting, control cabinets,
and manufacturing lines, the WLB32 uses advanced LED lighting
technology to provide a high-quality and maintenance free industrial
lighting solution for years.
•
•
•
•
•
•
•
Highly energy efficient for overall cost savings
High/Low/Off switch
Models with eye shield block side glare
Daisy chain power to multiple lights
Motion detection models available
Metal housing, shatterproof window
Easy installation with snap clips, or a choice of magnetic or
angle brackets
Model without
Motion Detector
WLB32 Industrial LED Light Bars are available as cascadable models
that can be "daisy-chained" together for a continuous length of lighting,
with a minimum of wiring. Each light bar can be turned to high, low, or
off independently of the other lights, upstream or downstream, in the
chain. A double-ended accessory cordset must be used between each
pair of cascading lights.
Model with
Motion Detector Shield and
Motion Detector
Model with Eye
90 to 264 V ac Models
Models
Lighted Length (mm)
Connector
Lumens
WLB32ZC285PBQMB
WLB32ZC570PBQMB
WLB32ZC850PBQMB
WLB32ZC1130PBQMB
285
570
750
1500
2250
3000
Custom Quick Disconnect
850
1130
The listed models include a U.S. power cable.
•
To order model with no power cable, omit the suffix "B" from the model number. For example, WLB32ZC285PBQM. For a
list of other countries' wall plug cables, refer to the Accessories list.
•
•
To order the light without the integral switch, omit the "PB" from the model number. For example, WLB32ZC285QMB.
To order the light with the integral motion detector, replace the 'PB' from the model number with 'M'. For example,
WLB32ZC285MQMB.
•
To order the light with the eye shield, add an 'E' after the length. For example, WLB32ZC285EPBQMB.
Important: Lea el siguiente instructivo antes de operar el luminario. Por favor descargue desde
www.bannerengineering.com toda la documentación técnica de los WLB32 Industrial LED Light Bar (AC),
disponibles en múltiples idiomas, para detalles del uso adecuado, aplicaciones, advertencias, y las
instrucciones de instalación de estos dispositivos.
Important: Lisez les instructions suivantes avant d'utiliser le luminaire. Veuillez télécharger la documentation
technique complète des WLB32 Industrial LED Light Bar (AC) sur notre site www.bannerengineering.com pour
les détails sur leur utilisation correcte, les applications, les notes de sécurité et les instructions de montage.
Original Document
176314 Rev. J
13 August 2019
176314
WLB32 Industrial LED Light Bar (AC)
Installing the WLB32 AC Series Lights
Figure 1. Attaching the Snap Brackets (Step 1)
Figure 2. Installing the Cascade Cover (Step 8)
1. Attach the snap brackets to the light.
2. Select a suitable horizontal or vertical dry mounting location.
3. Place the light in the mounting location and mark the positions of the snap bracket mounting holes.
4. Drill the holes and use appropriate screws to secure the snap bracket to the mounting location.
5. Snap the light onto the brackets.
6. When daisy chaining multiple lights, follow steps 1 through 5 to mount additional lights. See the application note in the
Specifications for the maximum allowed lights daisy chained together and maximum allowed cable run when choosing
mounting locations.
7. Connect the daisy chained units together using cascade cordsets (see Accessories).
8. Install the supplied cascade cover over the output connector on the last light in the chain.
9. Plug the power cord from the first light into the wall outlet.
CAUTION: To reduce the risk of fire, electric shock, or injury to personnel:
•
•
Use only insulated staples or plastic ties to secure cords;
Route and secure cords so that they will not be pinched or damaged when the cabinet is pushed to the
wall;
•
Position the portable cabinet light with respect to the cabinet so the lamp replacement markings are
able to be read during relamping;
•
•
Do not recess into ceilings or soffits; and
Do not conceal the cords. The National Electrical Code (NEC) does not permit cords to be concealed
where damage to insulation may go unnoticed. To prevent fire danger, do not run cord behind walls,
ceilings, soffits, or cabinets where it may be inaccessible for examination. Cords should be visually
examined periodically and immediately replaced when any damage is noted.
Specifications
Operating Voltage
90 to 264 V ac (50 or 60 Hz)
Power factor > 0.95 on high setting at 120 V ac
See electrical characteristics on product label
Supply Current
Light Length (mm)
Max Current Draw (A) at 90 V ac
Typical Current Draw (A)
120 V ac
230 V ac
285
570
0.125
0.250
0.375
0.500
0.075
0.150
0.225
0.300
0.045
0.080
0.115
0.150
850
1130
2
www.bannerengineering.com - Tel: + 1 888 373 6767
P/N 176314 Rev. J
WLB32 Industrial LED Light Bar (AC)
Supply Protection Circuitry
Protected against transient voltages
Environmental Rating
IEC IP50
Light Characteristics
Vibration and Mechanical Shock
Color: Daylight white
Vibration 10-55 Hz 1.0 mm p-p amplitude per IEC60068-2-6
Shock 15G 11 ms duration, half sine wave per IEC60068-2-27
Color temperature (CCT): 5000K ( 300K)
Lumen output: 750 ( 5ꢀ) per foot, typical at 25 ꢁC (77 ꢁF)
CRI: 85 typical
Operating Temperature
–25 ꢁC to +45 ꢁC (–13 ꢁF to 113 ꢁF)
Models with Motion Detection: –20 ꢁC to +45 ꢁC (–4 ꢁF to +113 ꢁF)
Eye shield reduces lumens by approximately 25ꢀ
LED Lifetime
Lumen Maintenance - L
When operating within specifications, output will decrease less than
30ꢀ after 50,000 hours.
Storage Temperature
–40 ꢁC to +70 ꢁC (–40 ꢁF to +158 ꢁF)
70
Test Data
LM-79, LM-80, TM-21
Push Button
II = 100ꢀ light intensity
I = 50ꢀ light intensity
O = Standby
Certifications
Models with Motion Detection
Light turns off after approximately 60 seconds without detecting
motion.
Range: 12 m; 45ꢁ field of view
Standby current: 170 µA
E476617
UL Listed only for
120 V ac, 60 Hz
UL Recognized for
easy installation in
control cabinets
Construction
Anodized aluminum housing; polycarbonate window and end caps;
Application Note
stainless steel mounting brackets
When connecting cascadable lights in series, do not exceed the
maximum unit limit of 10, regardless of light size, and do not
exceed a maximum wiring distance of 100 m (328 ft)
Spacing Criterion
Vertical: 1.22
Horizontal: 1.32
Mounting
Snap clips; optional magnetic mount or swivel bracket accessories
available
Connections
Integral custom QD (connecting cordset required)
Spacing Criteria (SC)
The spacing criteria is the fixture-spacing-to-mounting-height ratio and aids in laying out a pattern of fixtures. Multiply the spacing
criteria by the mounting height to get the maximum fixture spacing that still provides even illumination (no shadowing between
fixtures).
Luminaire Spacing = SC × Height to Illuminated Plane
The mounting height is the distance from the fixture to the surface you are lighting.
Light Characteristics
Illuminance at a Distance
Isolux Pattern
Polar Candela Distribution
2
1
1
2
0 m
2
1
180°
170°
160°
230
192
153
115
77
Center Beam (lux)
3682 lux
1979 lux
825 lux
Beam Width (m)
0.4 m 0.7 m
0.8 m 1.4 m
1.2 m 2.1 m
1.6 m 2.8 m
2.0 m 3.5 m
2.4 m 4.2 m
150°
140°
130°
0.17 m
0.33 m
0.50 m
0.67 m
120°
110°
100°
439 lux
38
345 lux
0
90°
80°
0 m
0.83 m
1.00 m
38
223 lux
77
70°
60°
50°
40°
Vert.
Horiz.
115
153
192
230
Vertical Spread: 101.5°
Horizontal Spread: 128.8°
1
2
30°
20°
10°
0°
Vertical Angle:
0° Vertical 90° Horizontal
Mount height of 1 meter (1 m)
150 lux
125 lux
100 lux
75 lux
50 lux
25 lux
10 lux
5 lux
50% max.
candela
Figure 3. 285 mm Models
P/N 176314 Rev. J
www.bannerengineering.com - Tel: + 1 888 373 6767
3
WLB32 Industrial LED Light Bar (AC)
Illuminance at a Distance
Isolux Pattern
Polar Candela Distribution
2
1
1
2
0 m
2
1
180°
170°
160°
460
383
307
230
153
77
Center Beam (lux)
4721 lux
2937 lux
1359 lux
785 lux
Beam Width (m)
0.4 m 0.7 m
0.8 m 1.4 m
1.2 m 2.1 m
1.6 m 2.7 m
2.0 m 3.4 m
2.4 m 4.1 m
150°
140°
130°
0.17 m
0.33 m
0.50 m
0.67 m
120°
110°
100°
621 lux
0
90°
80°
0 m
1
0.83 m
1.00 m
77
451 lux
153
230
307
383
460
70°
60°
50°
40°
Vert.
Horiz.
Vertical Spread: 101.5°
Horizontal Spread: 128.2°
30°
20°
10°
0°
Vertical Angle:
2
0° Vertical 90° Horizontal
Mount height of 1 meter (1 m)
300 lux
250 lux
200 lux
150 lux
100 lux
50 lux
25 lux
10 lux
50% max.
candela
Figure 4. 570 mm Models
Illuminance at a Distance
Isolux Pattern
Polar Candela Distribution
2
1
1
2
0 m
2
1
180°
170°
160°
650
542
433
325
217
108
0
Center Beam (lux)
5371 lux
3470 lux
1831 lux
1103 lux
Beam Width (m)
0.4 m 0.7 m
0.8 m 1.4 m
1.3 m 2.1 m
1.7 m 2.9 m
2.1 m 3.6 m
2.5 m 4.3 m
150°
140°
130°
0.17 m
0.33 m
0.50 m
0.67 m
120°
110°
100°
899 lux
90°
80°
0 m
0.83 m
1.00 m
108
217
325
433
542
650
647 lux
70°
60°
50°
40°
Vert.
Horiz.
Vertical Spread: 102.7°
1
2
Horizontal Spread: 130.1°
30°
20°
10°
0°
Vertical Angle:
0° Vertical 90° Horizontal
Mount height of 1 meter (1 m)
450 lux
375 lux
300 lux
225 lux
150 lux
75 lux
25 lux
10 lux
Illuminance at a Distance
50% max.
candela
Figure 5. 850 mm Models
Illuminance at a Distance
Isolux Pattern
Polar Candela Distribution
2
1
1
2
0 m
2
1
180°
170°
160°
870
725
580
435
290
145
0
Center Beam (lux)
5371 lux
Beam Width (m)
0.4 m 0.7 m
0.8 m 1.4 m
1.3 m 2.1 m
1.7 m 2.9 m
2.1 m 3.6 m
2.5 m 4.3 m
150°
140°
130°
0.17 m
0.33 m
0.50 m
0.67 m
3639 lux
120°
110°
100°
2008 lux
1274 lux
1065 lux
90°
80°
0 m
0.83 m
1.00 m
145
290
435
580
725
870
869 lux
70°
60°
50°
40°
Vert.
Horiz.
Vertical Spread: 103.3°
Horizontal Spread: 129.7°
1
2
30°
20°
10°
0°
Vertical Angle:
0° Vertical 90° Horizontal
Mount height of 1 meter (1 m)
600 lux
500 lux
400 lux
300 lux
200 lux
100 lux
50 lux
25 lux
50% max.
candela
Figure 6. 1130 mm Models
4
www.bannerengineering.com - Tel: + 1 888 373 6767
P/N 176314 Rev. J
WLB32 Industrial LED Light Bar (AC)
Illuminance at a Distance
Isolux Pattern
Polar Candela Distribution
2
1
1
2
0 m
2
1
180°
170°
160°
250
208
167
125
83
Center Beam (lux)
3654 lux
2024 lux
813 lux
Beam Width (m)
0.4 m 0.4 m
0.8 m 0.8 m
1.2 m 1.3 m
1.6 m 1.7 m
2.0 m 2.1 m
2.3 m 2.5 m
150°
140°
130°
0.17 m
0.33 m
0.50 m
0.67 m
120°
110°
100°
442 lux
42
345 lux
0
90°
80°
0 m
0.83 m
1.00 m
42
250 lux
83
70°
60°
50°
40°
Vert.
Horiz.
125
167
208
250
Vertical Spread: 98.7°
1
2
Horizontal Spread: 102.8°
30°
20°
10°
0°
Vertical Angle:
0° Vertical 90° Horizontal
Mount height of 1 meter (1 m)
150 lux
125 lux
100 lux
75 lux
50 lux
25 lux
10 lux
5 lux
50% max.
candela
Figure 7. 285 mm Models with Eye Shields
Illuminance at a Distance
Isolux Pattern
Polar Candela Distribution
2
1
1
2
0 m
2
1
180°
170°
160°
500
417
333
250
167
83
Center Beam (lux)
5334 lux
3313 lux
1595 lux
884 lux
Beam Width (m)
0.3 m 0.4 m
0.6 m 0.8 m
0.9 m 1.1 m
1.2 m 1.5 m
1.5 m 1.9 m
1.8 m 2.3 m
150°
140°
130°
0.17 m
0.33 m
0.50 m
0.67 m
120°
110°
100°
706 lux
0
90°
80°
0 m
0.83 m
1.00 m
83
484 lux
167
250
333
417
500
70°
60°
50°
40°
Vert.
Horiz.
Vertical Spread: 83.5°
1
2
Horizontal Spread: 97.0°
30°
20°
10°
0°
Vertical Angle:
0° Vertical 90° Horizontal
Mount height of 1 meter (1 m)
300 lux
250 lux
200 lux
150 lux
100 lux
50 lux
25 lux
10 lux
50% max.
candela
Figure 8. 570 mm Models with Eye Shields
Illuminance at a Distance
Isolux Pattern
Polar Candela Distribution
2
1
1
2
0 m
2
1
180°
170°
160°
630
525
420
315
210
105
0
Center Beam (lux)
5533 lux
3460 lux
1815 lux
1096 lux
896 lux
Beam Width (m)
0.3 m 0.5 m
0.6 m 1.0 m
0.9 m 1.6 m
1.2 m 2.1 m
1.4 m 2.6 m
1.7 m 3.1 m
150°
140°
130°
0.17 m
0.33 m
0.50 m
0.67 m
120°
110°
100°
90°
80°
0 m
0.83 m
1.00 m
105
210
315
420
525
630
623 lux
70°
60°
50°
40°
Vert.
Horiz.
Vertical Spread: 81.4°
Horizontal Spread: 114.2°
1
2
30°
20°
10°
0°
Vertical Angle:
0° Vertical 90° Horizontal
Mount height of 1 meter (1 m)
450 lux
375 lux
300 lux
225 lux
150 lux
75 lux
25 lux
10 lux
50% max.
candela
Figure 9. 850 mm Models with Eye Shields
P/N 176314 Rev. J
www.bannerengineering.com - Tel: + 1 888 373 6767
5
WLB32 Industrial LED Light Bar (AC)
Illuminance at a Distance
Isolux Pattern
Polar Candela Distribution
2
1
1
2
0 m
2
1
180°
170°
160°
820
683
547
410
273
137
0
Center Beam (lux)
5733 lux
Beam Width (m)
0.3 m 0.6 m
0.6 m 1.3 m
0.9 m 1.9 m
1.2 m 2.6 m
1.5 m 3.2 m
1.8 m 3.8 m
150°
140°
130°
0.17 m
0.33 m
0.50 m
0.67 m
3904 lux
120°
110°
100°
2203 lux
1390 lux
1139 lux
90°
80°
0 m
0.83 m
1.00 m
137
273
410
547
683
820
806 lux
70°
60°
50°
40°
Vert.
Horiz.
Vertical Spread: 83.8°
Horizontal Spread: 124.8°
1
2
30°
20°
10°
0°
Vertical Angle:
0° Vertical 90° Horizontal
Mount height of 1 meter (1 m)
600 lux
500 lux
400 lux
300 lux
200 lux
100 lux
50 lux
25 lux
50% max.
candela
Figure 10. 1130 mm Models with Eye Shields
Dimensions
L1
Motion Detector and/or Eye Shield Models
L2
Specific to models with shield
Model
Models without Motion Detector
L1
Models with Motion Detector and/or Eye Shield
L2
WLB32ZC285..QM
WLB32ZC570..QM
WLB32ZC850..QM
WLB32ZC1130..QM
298 mm (11.7 in)
580 mm (22.8 in)
862 mm (33.9 in)
1144 mm (45.0 in)
368 mm (14.5 in)
650 mm (25.6 in)
932 mm (36.7 in)
1214 mm (47.8 in)
6
www.bannerengineering.com - Tel: + 1 888 373 6767
P/N 176314 Rev. J
WLB32 Industrial LED Light Bar (AC)
Accessories
Wall Plug Cordsets
Model
LQMAC-306
Plug Type
Countries
Wire Gauge
Length
Dimensions
Flying Leads
United States, Canada,
Japan, Puerto Rico, Taiwan
LQMAC-306B
LQMAC-306D
NEMA 5-15 grounded (IEC Type B)
BS 546 (IEC Type D)
India
Germany, France, South
Korea, The Netherlands,
Poland, Spain, Turkey
LQMAC-306EF
LQMAC-306G
CEE 7/7 (IEC Type E or F)
BS 1363 (IEC Type G)
38
1.8 m (6 ft)
18 AWG
United Kingdom, Ireland,
Singapore, Vietnam
10
China, Australia, New
Zealand
LQMAC-306I
LQMAC-306N
LQMAC-310B
AS/NZS 3112 (IEC Type I)
18
NBR 14136 (IEC Type N)
Brazil
United States, Canada,
Japan, Puerto Rico, Taiwan
NEMA 5-15 grounded (IEC Type B)
3 m (10 ft)
Continuous Run/Cascade Cordsets
Model
Length
Style
Wire Gauge
Dimensions
LQMAEC-3005SS
LQMAEC-301SS
LQMAEC-303SS
LQMAEC-306SS
LQMAEC-312SS
LQMAEC-320SS
LQMAEC-330SS
0.15 m (0.5 ft)
0.31 m (1 ft)
0.91 m (3 ft)
1.83 m (6 ft)
3.66 m (12 ft)
6.1 m (20 ft)
9.14 m (30 ft)
38
Male straight/Male straight
18 AWG
10
14
38
18
14
Enclosure Accessories
LMBEDS Switch
•
•
Bracket with plunger switch to power lights when the enclosure is opened
Refer to datasheet 160672 for more information
Mounting Brackets
LMBWLB32
LMBWLB32-180S
20
12
20
42
•
Replaces the bracket that ships with the
•
Swivel bracket kit allows 180ꢁ of
movement
WLB32 light
•
•
Stainless steel
36
Includes 4 snap clips, 4 screws, and 2
insulator caps
36
2X Ø6.5
Ø6.4
P/N 176314 Rev. J
www.bannerengineering.com - Tel: + 1 888 373 6767
7
WLB32 Industrial LED Light Bar (AC)
Mounting Brackets
LMBWLB32MAG
LMBWLB32U
19
20
41
•
Magnetic mounting bracket for easy
attachment to steel and iron surfaces
•
•
Die cast bracket for rugged applications
Secured to light with included thumb
screw
18
36
•
Clearance hole for 6 mm (1/4 in) button
head screw
20
Ø36
LMBWLB32UT
41
•
•
Die cast bracket for rugged applications
Secured to light with included thumb
screw
18
•
Integral 1/4-20 stud for mounting
20
27
Banner Engineering Corp. Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or
replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not
cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO
BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES
RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT,
STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously
manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the
product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will
void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at
any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to:
www.bannerengineering.com.
For patent information, see www.bannerengineering.com/patents.
FCC Part 15 and CAN ICES-3 (B)/NMB-3(B)
This device complies with part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions:
1.
2.
This device may not cause harmful interference, and
This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the manufacturer.
Mexican Importer
Banner Engineering de Mexico, S de RL de CV
CALLE CABO VERDE 104
VISTA HERMOSA NUEVO LEÓN 64620
81 8363.2714
©
Banner Engineering Corp. All rights reserved
相关型号:
©2020 ICPDF网 联系我们和版权申明