WLB92ZCB550PBQMN [BANNER]

WLB92 Industrial LED Light Bar (AC Quick Disconnect);
WLB92ZCB550PBQMN
型号: WLB92ZCB550PBQMN
厂家: Banner Engineering    Banner Engineering
描述:

WLB92 Industrial LED Light Bar (AC Quick Disconnect)

文件: 总6页 (文件大小:503K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
WLB92 Industrial LED Light Bar (AC Quick  
Disconnect)  
Datasheet  
Banner's WLB92 is a very bright LED fixture/luminaire that features an even light output for a no glare 'glow'. The WLB92 series is  
designed for a wide variety of environments and applications, including but not limited to work stations, machine lighting, and low  
bay lighting. The WLB92 uses advanced LED lighting technology to provide a high-quality and maintenance free industrial lighting  
solution.  
Increase worker productivity and ergonomics with bright, high-quality, uniform light  
Exceptionally energy efficient for overall cost savings  
Durable light stands up to your environment with a rugged metal housing and shatter-resistant window  
Easy installation with snap clips  
Intensity can be controlled from 15% to 100% using the attached knob  
Rated for use at 120 V ac in North America  
Rated for use at 100 V ac to 277 V ac outside North America  
These AC quick disconnect models can be used as continuous run models that can be cascaded or "daisy-chained" together for a  
continuous length of lighting using a double-ended accessory cordset (see Accessories (p. 5)). Each light bar can be turned on,  
off, or dimmed independently of the other lights, upstream or downstream, in the chain.  
WLB92 Industrial LED Light Bars are available in several configurations including different lengths and cord options. WLB92 (AC)  
Daylight White and Warm White models come with a five year, limited warranty. To view or download the latest technical  
information about this product, including specifications, dimensions, accessories, and wiring, see www.bannerengineering.com.  
Important: Lea el siguiente instructivo antes de operar el luminario. Por favor descargue desde  
www.bannerengineering.com toda la documentación técnica de los WLB92 Industrial LED Light Bar (AC Quick  
Disconnect), disponibles en múltiples idiomas, para detalles del uso adecuado, aplicaciones, advertencias, y las  
instrucciones de instalación de estos dispositivos.  
Important: Lisez les instructions suivantes avant d'utiliser le luminaire. Veuillez télécharger la documentation  
technique complète des WLB92 Industrial LED Light Bar (AC Quick Disconnect) sur notre site  
www.bannerengineering.com pour les détails sur leur utilisation correcte, les applications, les notes de sécurité  
et les instructions de montage.  
Models  
Lighted  
Control  
Family  
Voltage Cascadable  
Length (mm)  
Connector  
Plug Type (1.8 m cable)  
LED Color  
WLB92  
Z
C
550  
QM  
B
PB  
Z = AC  
C = Cascadable Blank = Daylight White  
550  
1100  
QM = Custom Quick  
Disconnect (QD) *  
PB = Switch,  
Dimming  
Knob  
B = North & Central America, Japan, Taiwan  
D = India, Sri Lanka, Nepal, Namibia  
WW = Warm White  
G = Green  
R = Red  
EF = France, Belgium, Slovakia, Tunisia, Germany,  
Austria, Netherlands, Spain,  
S. Korea  
Y = Yellow  
B = Blue  
G = UK, Ireland, Cyprus, Malta, Malaysia,  
Singapore, Hong Kong, Vietnam  
* QD models require a mating cordset  
I = Australia, New Zealand, Papua New Guinea,  
Argentina, China  
N = Brazil, South Africa  
C = AC connector with flying leads  
Blank = no power cord  
Original Document  
183984 Rev. H  
22 August 2019  
183984  
WLB92 Industrial LED Light Bar (AC Quick Disconnect)  
Installing the WLB92 Industrial LED Light Bar (AC Quick Disconnect Models)  
Figure 1. Attaching the snap brackets (step 6)  
Figure 2. Installing the cascade cover (step 9)  
1. Attach the snap brackets to the light.  
2. Select a suitable horizontal or vertical dry mounting location. The maximum distance to the power receptacle cannot be  
farther than the length of the power cord used.  
3. Place the light in the mounting location and mark the positions of the snap bracket mounting holes.  
4. Remove the brackets from the light.  
5. Drill the holes and use appropriate screws to secure the snap bracket to the mounting location.  
6. Snap the light onto the brackets.  
7. When installing cascading lights, repeat steps 1 through 6 to mount additional lights. See the application note in the  
Specifications section for the maximum cascaded lights and maximum allowed cable run when choosing mounting  
locations.  
8. Connect the cascaded lights together using an applicable cordset (see Accessories (p. 5)).  
9. Install the supplied cover over the output connector on the last light in the chain.  
10. Plug the power cord from the first light into the wall outlet. A 3 m (10 ft) cord is available for applications requiring a longer  
cord for cabinet installations.  
CAUTION: To reduce the risk of fire, electrical shock, or injury to personal:  
Use only insulated staples or plastic ties to secure cords  
Route and secure cords so that they will not be pinched or damaged when the cabinet is pushed to the  
wall  
Position the portable cabinet light with respect to the cabinet so the lamp replacement markings are  
able to be read during relamping  
Do not recess into ceilings or soffits  
Do not conceal the cords. The National Electrical Code (NEC) does not permit cords to be concealed  
where damage to insulation may go unnoticed. To prevent fire danger, do not run cords behind walls,  
ceilings, soffits, or cabinets where it may be inaccessible for examination. Cords should be visually  
examined periodically and immediately replaced when any damage is noted.  
CAUTION: To Reduce the Risk of Fire. Do not install the 550 mm models in a compartment smaller than 305  
mm by 305 mm by 675 mm. Do not install the 1100 mm models in a compartment smaller than 305 mm by 305  
mm by 1350 mm.  
2
www.bannerengineering.com - Tel: + 1 888 373 6767  
P/N 183984 Rev. H  
WLB92 Industrial LED Light Bar (AC Quick Disconnect)  
Specifications  
Supply Voltage  
Construction  
Nominal voltage: 120 V ac, 60 Hz in North America  
Nominal voltage: 100 V ac to 277 V ac, 50/60 Hz outside North America  
Power factor: > 0.95 at 120 V ac and > 0.90 at 230 V ac  
Total harmonic distortion (THD): < 20%  
Anodized aluminum housing, polycarbonate window and end caps, and  
stainless steel mounting brackets  
Spacing Criterion  
Vertical: 1.20  
Horizontal: 1.32  
See electrical characteristics on product label  
Supply Current  
Connections  
Integral custom quick disconnect (connecting cordset required)  
Typical Current Draw (A)  
Lighted Length  
(mm)  
Max. Current Draw  
(A) at 90 V ac  
Mounting  
120 V ac  
230 V ac  
Snap mount brackets included (two for the 550 mm model; three for the  
1100 mm model)  
Compatible with integral 45 mm aluminum framing mounting slots  
550  
0.425  
0.850  
0.270  
0.540  
0.135  
0.250  
1100  
Operating Temperature  
550 Lighted Length: –35 °C to +50 °C (–31 °F to +122 °F) for 24 hours per  
day for 5 years of operation  
1100 Lighted Length: –40 °C to +45 °C (–40 °F to +113 °F) for 16 hours per  
day for 5 years of operation; or –40 °C to +35 °C (–40 °F to +95 °F) for 24  
hours per day for 5 years of operation  
Supply Protection Circuitry  
Protected against transient voltages  
Light Characteristics  
Daylight White and Warm White Efficacy: 110 lumens/watt typical at 120 V  
ac at 25 °C (77 °F)  
CRI: 82, typical  
Storage Temperature  
–40 °C to +70 °C (–40 °F to +158 °F)  
Vibration and Mechanical Shock  
Vibration: 10 Hz to 55 Hz, 0.5 mm peak-to-peak amplitude per IEC  
60068-2-6  
Shock: 5G 11 ms duration, half sine wave per IEC 60068-2-27  
Color  
Dominant Wavelength  
(nm) or Color  
Lighted Length Lumens  
(Typical at 25 °C)  
Temperature (CCT)  
Application Notes  
550 mm  
3510  
1100 mm  
When connecting continuous run/cascadable lights in series, see table for  
maximum number of units. Do not exceed a maximum wiring distance of  
100 m (328 ft) in the main power cable and any cascading cables.  
Daylight  
White  
5000 K ( 300 K)  
7150  
7150  
Maximum Unit Limit (when using both model lengths)  
Warm  
White  
3000 K (+225 K, -125 K)  
3510  
550 mm Lights  
1100 mm Lights  
Green  
Red  
525 nm  
625 nm  
590 nm  
470 nm  
1430  
745  
620  
405  
2975  
1545  
1295  
840  
10  
8
0
1
2
3
4
5
6
Yellow  
Blue  
4
2
0
Test Data  
LM-79, LM-80, TM-21  
For example, if you use four 550 mm lights, you may add up to three 1100  
mm lights within the same continuous run.  
Environmental Rating  
IEC IP40  
Certifications  
LED Lifetime  
Lumen Maintenance - L70  
When operating within specifications, output will decrease less than 30%  
after 50,000 hours.  
Switch/Dimming Knob  
On/Off Switch and dimming knob, dimmable to 15% intensity  
Spacing Criteria (SC)  
The spacing criteria is the fixture-spacing-to-mounting-height ratio and aids in laying out a pattern of fixtures. Multiply the spacing  
criteria by the mounting height to get the maximum fixture spacing that still provides even illumination (no shadowing between  
fixtures).  
Luminaire Spacing = SC × Height to Illuminated Plane  
The mounting height is the distance from the fixture to the surface you are lighting.  
P/N 183984 Rev. H  
www.bannerengineering.com - Tel: + 1 888 373 6767  
3
WLB92 Industrial LED Light Bar (AC Quick Disconnect)  
Performance Curves  
550 mm Models - Daylight White and Warm White  
Illuminance at a Distance  
Polar Candela Distribution  
Isolux Pattern  
6
3
3
6
0 m  
Center Beam (lux)  
3,630 lux  
1,117 lux  
496 lux  
Beam Width (m)  
1.08 m 2.33 m  
2.15 m 4.67 m  
3.23 m 7.00 m  
4.30 m 9.33 m  
5.38 m 11.67 m  
6.45 m 14.00 m  
180°  
170°  
160°  
6
3
1100  
917  
733  
550  
367  
183  
0
150°  
140°  
130°  
0.5 m  
1.0 m  
1.5 m  
2.0 m  
120°  
110°  
100°  
279 lux  
179 lux  
2.5 m  
3.0 m  
90°  
80°  
124 lux  
0 m  
183  
367  
550  
733  
917  
1100  
Vert.  
Horiz.  
70°  
60°  
50°  
40°  
Vertical Spread: 94.2°  
Horizontal Spread: 133.6°  
3
6
30°  
20°  
10°  
0°  
Vertical Angle:  
0° Vertical 90° Horizontal  
Mount height of 3 meters (3 m)  
100 lux  
75 lux  
50 lux  
40 lux  
30 lux  
20 lux  
10 lux  
5 lux  
50% max.  
candela  
1100 mm Models - Daylight White and Warm White  
Polar Candela Distribution  
Isolux Pattern  
Illuminance at a Distance  
6
3
3
6
0 m  
Center Beam (lux)  
5,060 lux  
1,870 lux  
932 lux  
Beam Width (m)  
1.12 m 2.26 m  
2.25 m 4.53 m  
3.37 m 6.79 m  
4.50 m 9.06 m  
5.62 m 11.32 m  
6.74 m 13.58 m  
180°  
170°  
160°  
6
3
2200  
1833  
1467  
1100  
733  
150°  
140°  
130°  
0.5 m  
1.0 m  
1.5 m  
2.0 m  
120°  
110°  
100°  
524 lux  
367  
335 lux  
2.5 m  
3.0 m  
0
90°  
80°  
233 lux  
0 m  
367  
Vert.  
Horiz.  
733  
70°  
60°  
50°  
40°  
Vertical Spread: 96.7°  
1100  
1467  
1833  
2200  
Horizontal Spread: 132.3°  
3
6
30°  
20°  
10°  
0°  
Vertical Angle:  
0° Vertical 90° Horizontal  
Mount height of 3 meters (3 m)  
200 lux  
150 lux  
100 lux  
75 lux  
50 lux  
25 lux  
10 lux  
5 lux  
50% max.  
candela  
Dimensions  
L1  
L2  
104  
[4.1]  
14  
[.56]  
97  
[3.8]  
45  
[1.8]  
Model  
L1  
L2  
WLB92ZC...550PBQM  
WLB92ZC...1100PBQM  
543 mm (21.4 in)  
1098 mm (43.2 in)  
651 mm (25.6 in)  
1206 mm (47.5 in)  
4
www.bannerengineering.com - Tel: + 1 888 373 6767  
P/N 183984 Rev. H  
WLB92 Industrial LED Light Bar (AC Quick Disconnect)  
Accessories  
Wall Plug Cordsets  
Model  
Plug Type  
Countries  
Length  
Dimensions  
LQMAC-306  
Flying Leads  
NEMA 5-15 grounded (IEC Type  
B)  
United States, Canada, Japan,  
Puerto Rico, Taiwan  
LQMAC-306B  
LQMAC-306D  
BS 546 (IEC Type D)  
India  
Germany, France, South Korea,  
The Netherlands, Poland, Spain,  
Turkey  
38  
LQMAC-306EF  
LQMAC-306G  
CEE 7/7 (IEC Type E or F)  
1.8 m (6 ft)  
10  
United Kingdom, Ireland,  
Singapore, Vietnam  
BS 1363 (IEC Type G)  
LQMAC-306I  
LQMAC-306N  
AS/NZS 3112 (IEC Type I)  
NBR 14136 (IEC Type N)  
China, Australia, New Zealand  
Brazil  
18  
NEMA 5-15 grounded (IEC Type  
B)  
United States, Canada, Japan,  
Puerto Rico, Taiwan  
LQMAC-310B  
3 m (10 ft)  
For other lengths of the LQMAC-306 cables, contact the factory. LQMAC-310B is available for applications requiring a 3 m (10 ft)  
cord for cabinet installation. For complete listing of countries and wall plug types, see the IEC World Plugs website.  
Continuous Run/Cascade Cordsets  
Model  
Length  
Style  
Dimensions  
LQMAEC-3005SS  
LQMAEC-301SS  
LQMAEC-303SS  
LQMAEC-306SS  
LQMAEC-312SS  
LQMAEC-320SS  
LQMAEC-330SS  
0.15 m (0.5 ft)  
0.31 m (1 ft)  
0.91 m (3 ft)  
1.83 m (6 ft)  
3.66 m (12 ft)  
6.1 m (20 ft)  
9.14 m (30 ft)  
38  
Male straight/Male straight  
10  
14  
38  
18  
14  
Brackets  
LMBWLB92CLIP  
89  
Snap clip allows for tool-less installation  
Stainless steel  
20  
Ø6.5  
Includes four snap clips, four screws, and  
two insulator caps  
The LMBWLB92CLIP bracket replaces the bracket that ships  
with the WLB92 light.  
P/N 183984 Rev. H  
www.bannerengineering.com - Tel: + 1 888 373 6767  
5
WLB92 Industrial LED Light Bar (AC Quick Disconnect)  
Banner Engineering Corp. Limited Warranty  
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for five years on daylight white and warm white models and one year on all other  
models following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is  
found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner  
product.  
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.  
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO  
BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES  
RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT,  
STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.  
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously  
manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the  
product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will  
void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at  
any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to:  
www.bannerengineering.com.  
For patent information, see www.bannerengineering.com/patents.  
FCC Part 15 and CAN ICES-3 (B)/NMB-3(B)  
This device complies with part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions:  
1.  
2.  
This device may not cause harmful interference, and  
This device must accept any interference received, including interference that may cause undesired operation.  
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). These limits are  
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not  
installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a  
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is  
encouraged to try to correct the interference by one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
Consult the manufacturer.  
Mexican Importer  
Banner Engineering de Mèxico, S. de R.L. de C.V.  
David Alfaro Siqueiros 103 Piso 2 Valle oriente  
San Pedro Garza Garcia Nuevo Leòn, C. P. 66269  
81 8363.2714  
©
Banner Engineering Corp. All rights reserved  

相关型号:

WLB92ZCG1100ACT

WLB92 Industrial LED Light Bar (AC Conduit)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER

WLB92ZCG1100PBQMB

WLB92 Industrial LED Light Bar (AC Quick Disconnect)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER

WLB92ZCG1100PBQMC

WLB92 Industrial LED Light Bar (AC Quick Disconnect)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER

WLB92ZCG1100PBQMD

WLB92 Industrial LED Light Bar (AC Quick Disconnect)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER

WLB92ZCG1100PBQMEF

WLB92 Industrial LED Light Bar (AC Quick Disconnect)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER

WLB92ZCG1100PBQMG

WLB92 Industrial LED Light Bar (AC Quick Disconnect)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER

WLB92ZCG1100PBQMI

WLB92 Industrial LED Light Bar (AC Quick Disconnect)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER

WLB92ZCG1100PBQMN

WLB92 Industrial LED Light Bar (AC Quick Disconnect)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER

WLB92ZCG550ACT

WLB92 Industrial LED Light Bar (AC Conduit)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER

WLB92ZCG550PBQMB

WLB92 Industrial LED Light Bar (AC Quick Disconnect)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER

WLB92ZCG550PBQMC

WLB92 Industrial LED Light Bar (AC Quick Disconnect)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER

WLB92ZCG550PBQMD

WLB92 Industrial LED Light Bar (AC Quick Disconnect)

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
BANNER