WLB92ZCR1100ACT [BANNER]
WLB92 Industrial LED Light Bar (AC Conduit);型号: | WLB92ZCR1100ACT |
厂家: | Banner Engineering |
描述: | WLB92 Industrial LED Light Bar (AC Conduit) |
文件: | 总5页 (文件大小:623K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
WLB92 Industrial LED Light Bar (AC Conduit)
Datasheet
Banner's WLB92 is a very bright LED fixture/luminaire that features an even light output for a no glare glow. The WLB92 series is designed for a wide
variety of environments and applications, including but not limited to work stations, machine lighting, and low bay lighting. The WLB92 uses
advanced LED lighting technology to provide a high-quality and maintenance free industrial lighting solution.
•
•
•
•
•
•
Increase worker productivity and ergonomics with bright, high-quality, uniform light
Exceptionally energy efficient for overall cost savings
Durable light with a rugged metal housing and shatter-resistant window
Easy installation with surface mount brackets or choice of snap, swivel, or hanging brackets
Intensity can be controlled from 10% to 100% using a compatible dimmer
Rated for use at 100 V ac to 277 V ac
WLB92 Industrial LED Light Bar, AC conduit versions, are continuous run models that come with 1/2-inch conduit knockouts on the side and back of
both end caps that allow for lights to be cascaded or "daisy-chained" for a continuous length of light. All conduit models are compatible with select
dimming units (see Accessories). WLB92 (AC) Daylight White and Warm White models come with a five year, limited warranty.
To view or download the latest technical information about this product, including specifications, dimensions, accessories, and wiring, see
www.bannerengineering.com.
Important: Lea el siguiente instructivo antes de operar el luminario. Por favor descargue desde www.bannerengineering.com
toda la documentación técnica de los WLB92 Industrial LED Light Bar (AC Conduit), disponibles en múltiples idiomas, para
detalles del uso adecuado, aplicaciones, advertencias, y las instrucciones de instalación de estos dispositivos.
Important: Lisez les instructions suivantes avant d'utiliser le luminaire. Veuillez télécharger la documentation technique
complète des WLB92 Industrial LED Light Bar (AC Conduit) sur notre site www.bannerengineering.com pour les détails sur leur
utilisation correcte, les applications, les notes de sécurité et les instructions de montage.
Models
Lighted
Length (mm) Control
Family
Voltage Cascadable
LED Color
Connector
WLB92
Z
C
550
A
CT
550
1100
A = 0-10 V Analog CT = Conduit Entry
Dimming
Z = AC C = Cascadable Blank = Daylight White
WW = Warm White
G = Green
R = Red
Y = Yellow
B = Blue
Installing the WLB92 Industrial LED Light Bar (AC Conduit Models)
WARNING: Risk of Electric Shock
Disconnect or turn off power before installing,
removing, or servicing luminaire.
•
•
Luminaire must be installed and connected in
accordance with the National Electrical Code (NEC)
and any applicable local code requirements.
Luminaire must be supplied with a 120–277 V ac
50/60 Hz fuse box or circuit breaker
•
Figure 1. Mounting the luminaire to the surface mount brackets
To mount the WLB92 Industrial LED Light Bar, follow these steps.
Original Document
183985 Rev. I
22 August 2019
183985
WLB92 Industrial LED Light Bar (AC Conduit)
1. Remove luminaire from packaging and inspect for damage before installing.
2. Locate the supplied surface mount brackets. (For suspended installation, refer to the separate hanging bracket kit and instructions.)
3. Insert the screws into the bracket and then screw on the t-nuts. Attach bracket assembly to luminaire housing as shown. Fully tighten the
screws to lock in place.
4. Place the light in the mounting location and mark the positions of the bracket mounting holes.
5. Drill the holes and use the appropriate screws to secure the luminaire to the mounting location.
CAUTION: To Reduce the Risk of Fire. Do not install the 550 mm models in a compartment smaller than 305 mm by 305 mm
by 675 mm. Do not install the 1100 mm models in a compartment smaller than 305 mm by 305 mm by 1350 mm.
Wiring the WLB92 Industrial LED Light Bar
Follow these steps to wire your WLB92 Industrial LED Light Bar AC Conduit models.
1/2” Trade Size Knockouts
Wiring Chamber
Remove
access cap
Pull latch out
to release or
insert wire
1. Loosen the screws to remove the access cap from the wiring chamber.
2. Connect the power.
•
•
•
To connect the power from the back of the luminaire, remove the knockout from the back of the access cap and install either 1/2-inch
conduit or an AC power cord with strain relief.
To connect the power from the side of the luminaire: remove the knockout from the side of the access cap and install either 1/2-inch
conduit or an AC power cord with strain relief on the luminaire wires.
If using rigid conduit, the conduit hub/connector must be approved for use in dry or damp locations and must be connected to the
conduit before the hub/connector is connected to the luminaire.
3. Pull the luminaire wires out of the wiring chamber, then pull the field wires through the knockouts and out of the wiring chamber.
4. Lift the latch a full 90° on the unused terminal block locations and make the following electrical connections:
a) Connect the green/yellow luminaire wire to the AC ground power wire
b) Connect the white luminaire wire to the AC neutral power wire
c) Connect the black luminaire wire to the AC line power wire
d) If using 0–10 V analog dimming, connect the purple luminaire wire to the positive dimming wire
e) If using 0–10 V analog dimming, connect the gray luminaire wire to the negative dimming wire
5. Close the latches on each terminal block when you have finished wiring, and push all wires back into the wiring chamber.
6. Re-attach the access cap to the wiring chamber.
7. Repeat steps 1 through 5 on other end of the luminaire if you are connecting to more than one luminaire in a continuous run.
Wiring Diagram
Diagram
Wire
Connection
L - Black
N - White
Line/Hot
Neutral
L
L
Earth ground
N
N
- Green/Yellow
Dim (+) - Purple
0–10 V dc analog dimming
Dim (+)
Dim (-)
Dim (+)
Dim (-)
Dim (-) - Gray
Return analog dimming
2
www.bannerengineering.com - Tel: + 1 888 373 6767
P/N 183985 Rev. I
WLB92 Industrial LED Light Bar (AC Conduit)
Specifications
Supply Voltage
Dimming
Compatible with 0–10 V analog LED dimming, dimmable to 10% intensity
Compatible dimmers are listed in the Accessories section.
Nominal voltage: 120 V ac to 277 V ac, 60 Hz in North America
Nominal voltage: 100 V ac to 277 V ac, 50/60 Hz outside North America
Power factor: > 0.95 at 120 V ac and > 0.90 at 277 V ac
Total harmonic distortion (THD): < 20%
Construction
Anodized aluminum housing, polycarbonate window and end caps, and stainless steel
mounting brackets
See electrical characteristics on product label
Supply Current
Spacing Criterion
Vertical: 1.20
Horizontal: 1.32
Typical Current Draw (A)
230 V ac
Max. Current
Draw (A) at
90 V ac
Lighted
Length (mm)
Mounting
120 V ac
277 V ac
Surface mount brackets included (2)
Compatible with integral 45 mm aluminum framing mounting slots
Several optional mounting brackets available (see Accessories)
550
0.425
0.850
0.270
0.540
0.145
0.285
0.135
0.250
1100
Connections
1/2-inch trade size conduit knockout
Environmental Rating
IEC IP40
Supply Protection Circuitry
Protected against transient voltages
Light Characteristics
Daylight White and Warm White Efficacy: 110 lumens/watt typical at 120 V ac at 25 °C
(77 °F)
CRI: 82, typical
Operating Temperature for 550 mm Lighted Length Models
Surface Mount Installation: –35 °C to +50 °C (–31 °F to +122 °F) for 24 hours per day
for 5 years of operation
Hanging Installation (> 0.5 m from ceiling): –35 °C to +50 °C (–31 °F to +122 °F) for 24
hours per day for 5 years of operation
Operating Temperature for 1100 mm Lighted Length Models
Surface Mount Installation: –40 °C to +45 °C (–40 °F to +113 °F) for 16 hours per day
for 5 years of operation; or –40 °C to +35 °C (–40 °F to +95 °F) for 24 hours per day for
5 years of operation
Hanging Installation (> 0.5 m from ceiling): –40 °C to +50 °C (–40 °F to +122 °F) for 16
hours per day for 5 years of operation; or –40 °C to +45 °C (–40 °F to +113 °F) for 24
hours per day for 5 years of operation
Color
Dominant Wavelength (nm)
or Color Temperature
(CCT)
Lighted Length Lumens
(Typical at 25 °C)
550 mm
3510
1100 mm
7150
Daylight
White
5000 K ( 300 K)
Storage Temperature
–40 °C to +70 °C (–40 °F to +158 °F)
Warm
White
3510
7150
3000 K
(+225 K, -125 K)
Vibration and Mechanical Shock
Vibration: 10 Hz to 55 Hz, 0.5 mm peak-to-peak amplitude per IEC 60068-2-6
Shock: 5G 11 ms duration, half sine wave per IEC 60068-2-27
Green
Red
525 nm
625 nm
590 nm
470 nm
1430
745
620
405
2975
1545
1295
840
Application Notes
When connecting continuous run/cascadable lights in series, it is important not to
exceed maximum current limitations of 14 AWG, 75 °C wire, in accordance with the
National Electrical Code (NEC) and any applicable local code requirements.
Yellow
Blue
Certifications
LED Lifetime
Lumen Maintenance - L70
When operating within specifications, output will decrease less than 30% after 50,000
hours.
Test Data
LM-79, LM-80, TM-21
Spacing Criteria (SC)
The spacing criteria is the fixture-spacing-to-mounting-height ratio and aids in laying out a pattern of fixtures. Multiply the spacing criteria by the
mounting height to get the maximum fixture spacing that still provides even illumination (no shadowing between fixtures).
Luminaire Spacing = SC × Height to Illuminated Plane
The mounting height is the distance from the fixture to the surface you are lighting.
Performance Curves
550 mm Models - Daylight White and Warm White
Illuminance at a Distance
Polar Candela Distribution
Isolux Pattern
6
3
3
6
0 m
Center Beam (lux)
3,630 lux
1,117 lux
496 lux
Beam Width (m)
1.08 m 2.33 m
2.15 m 4.67 m
3.23 m 7.00 m
4.30 m 9.33 m
5.38 m 11.67 m
6.45 m 14.00 m
180°
170°
160°
6
3
1100
917
733
550
367
183
0
150°
140°
130°
0.5 m
1.0 m
1.5 m
2.0 m
120°
110°
100°
279 lux
179 lux
2.5 m
3.0 m
90°
80°
124 lux
0 m
183
367
550
733
917
1100
Vert.
Horiz.
70°
60°
50°
40°
Vertical Spread: 94.2°
Horizontal Spread: 133.6°
3
6
30°
20°
10°
0°
Vertical Angle:
0° Vertical 90° Horizontal
Mount height of 3 meters (3 m)
100 lux
75 lux
50 lux
40 lux
30 lux
20 lux
10 lux
5 lux
50% max.
candela
P/N 183985 Rev. I
www.bannerengineering.com - Tel: + 1 888 373 6767
3
WLB92 Industrial LED Light Bar (AC Conduit)
1100 mm Models - Daylight White and Warm White
Polar Candela Distribution
Isolux Pattern
Illuminance at a Distance
6
3
3
6
0 m
Center Beam (lux)
5,060 lux
1,870 lux
932 lux
Beam Width (m)
180°
170°
160°
6
3
2200
1833
1467
1100
733
150°
140°
130°
1.12 m 2.26 m
2.25 m 4.53 m
3.37 m 6.79 m
4.50 m 9.06 m
5.62 m 11.32 m
6.74 m 13.58 m
0.5 m
1.0 m
1.5 m
2.0 m
120°
110°
100°
524 lux
367
335 lux
2.5 m
3.0 m
0
90°
80°
233 lux
0 m
367
Vert.
Horiz.
733
70°
60°
50°
40°
Vertical Spread: 96.7°
1100
1467
1833
2200
Horizontal Spread: 132.3°
3
6
30°
20°
10°
0°
Vertical Angle:
0° Vertical 90° Horizontal
Mount height of 3 meters (3 m)
200 lux
150 lux
100 lux
75 lux
50 lux
25 lux
10 lux
5 lux
50% max.
candela
Dimensions
L1
L2
104
[4.1]
97
[3.8]
22.2 [0.88]
45
[1.8 ]
Model
WLB92ZC...550ACT
L1
L2
543 mm (21.4 in)
1098 mm (43.2 in)
651 mm (25.6 in)
1206 mm (47.5 in)
WLB92ZC...1100ACT
Accessories
Brackets
LMBWLB92
LMBWLB92CLIP
25.4
89
•
Standard bracket that ships with the WLB92
light
•
•
•
Snap clip allows for tool-less installation
Stainless steel
150
•
•
Stainless steel
Includes four snap clips, four screws, and two
insulator caps
9.7
20
Ø6.5
Includes two surface mount brackets, four
screws, and four t-nuts
4 x Ø7
4
www.bannerengineering.com - Tel: + 1 888 373 6767
P/N 183985 Rev. I
WLB92 Industrial LED Light Bar (AC Conduit)
LMBWLB92HK5
LMBWLB92RAS
40
•
Hanging bracket kit allows for suspended
•
Swivel brackets allow for 180° of movement in
79
installation
seven fixed positions
70
•
Includes two hanging bracket assemblies, four
screws, four t-nuts, and two 15-24 mm cables
•
•
Stainless steel
Includes two swivel bracket assemblies, eight
screws, and four t-nuts
2 x Ø7
60
21
2X M6 BHCS
65
LMBWLB92S
80
105
•
Surface mount brackets allow for mounting at
the end of the light
•
•
Stainless steel
9.7
Includes two end brackets, four screws, and
four t-nuts
4 x Ø7
Dimmers
Dimmers with Full Dimming Range:
Dimmers with Limited Dimming Range:
Lutron Diva Family
DVST-XX
DVSCSTV-XX
Leviton Illumatech Family
IP710-LFZ
Leviton Renoir II Family
AWSMT-7DW
AWSMG-7DW
Lutron Nova T Family
NTSTV-DV-XX
AWRMG-7DW
Lutron Maestro Family (dimmer with sensor)
MS-Z101-XX
Banner Engineering Corp. Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for five years on daylight white and warm white models and one year on all other models following the date of
shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period.
This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER
PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR
FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner
Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such
purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this
document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is
provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com.
For patent information, see www.bannerengineering.com/patents.
FCC Part 15 and CAN ICES-3 (B)/NMB-3(B)
This device complies with part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the manufacturer.
Mexican Importer
Banner Engineering de Mèxico, S. de R.L. de C.V.
David Alfaro Siqueiros 103 Piso 2 Valle oriente
San Pedro Garza Garcia Nuevo Leòn, C. P. 66269
81 8363.2714
©
Banner Engineering Corp. All rights reserved
相关型号:
©2020 ICPDF网 联系我们和版权申明