WLS27XY850DSQ [BANNER]
WLS27 LED Strip Light;型号: | WLS27XY850DSQ |
厂家: | Banner Engineering |
描述: | WLS27 LED Strip Light |
文件: | 总2页 (文件大小:173K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
WLS27 LED Strip Light
Datasheet
For additional technical information about this product, including complete instructions, dimensions, accessories, and
specifications, see http://www.bannerengineering.com and search for 185590.
Models
Lighted
Length (mm)
Family
Cascadable
LED Color
Window Construction Connector
S
WLS27
C
Q
W
145
D
S = Sealed
145
285
430
570
710
850
990
1130
C = Cascadable
X = Non-cascadable
W = Cool white
WW = Warm white
R = Red
D = Diffused plastic
Q = Integral 4-pin M12 QD
(mating cordset required)
G = Green
B = Blue
Y = Yellow
Specifications
Supply Voltage
12 to 30 V dc
Typical Current
24 V dc
Max. Current
A
Light Length
Use only with suitable Class 2 power supply (UL) or a SELV power supply
12 V dc
30 V dc
(CE).
145 mm
285 mm
430 mm
570 mm
710 mm
850 mm
990 mm
1130 mm
0.33 A
0.66 A
1.01 A
1.36 A
1.75 A
2.13 A
2.59 A
3.04 A
0.15 A
0.30 A
0.46 A
0.61 A
0.77 A
0.92 A
1.08 A
1.24 A
0.12 A
0.24 A
0.36 A
0.48 A
0.60 A
0.73 A
0.85 A
0.97 A
0.4
0.8
1.2
1.6
2.0
2.4
2.8
3.2
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Application Note
When connecting cascadable lights in series at 100% intensity, it is
important not to exceed maximum current limitations:
Maximum length of light at 12 V dc: 1.4 m (4.6 ft)
Maximum length of light at 24 V dc: 3.0 m (9.8 ft)
Maximum length of light at 30 V dc: 3.1 m (10.2 ft)
At 50% intensity, double the lengths.
Construction
Clear anodized aluminum housing; FDA-grade copolyester outer housing
Mounting
Bracket LMBWLS27EC included (2 for lights up to 570 mm or 3 for lights
710 mm and longer)
Environmental Rating
Rated IEC IP66, IP67, and IP69K, per DIN 40050
Connections
Operating Temperature
–40 °C to +70 °C (–40 °F to +158 °F)
Integral 4-pin M12 male quick disconnect (QD) (4-pin connecting cordset
required)
Light output begins to decrease above 50 °C (122 °F) and will be
approximately 65% of max intensity at 60 °C (140 °F) and 30% of max
intensity at 70 °C (158 °F)
Certifications
Storage Temperature
–40 °C to +70 °C (–40 °F to +158 °F)
D
Vibration and Mechanical Shock
Vibration 10-55 Hz 1.0 mm p-p amplitude per IEC 60068-2-6
Shock 15G 11 ms duration, half sine wave per IEC 60068-2-27
Note: Do not spray cable with high-pressure
sprayer, or cable damage will result.
Original Document
189555 Rev. D
25 January 2019
189555
WLS27 LED Strip Light
Dimensions
L3
L2
L1
17.6
[.69]
17.6
[.69]
16.8
[.66]
16.8
[.66]
27.0
[1.06]
M12 X 1
Figure 1. Quick Disconnect Models
L4
27.0
[1.06]
17.6
[.69]
16.8
[.66]
16.8
[.66]
17.6
[.69]
M12 X 1
M12 X 1
Figure 2. Cascade Models
L2
Models
L1
L3
L4
WLS27..145..
WLS27..285..
WLS27..430..
WLS27..570..
WLS27..710..
WLS27..850..
WLS27..990..
WLS27..1130..
145 mm (5.7 in)
286 mm (11.3 in)
427 mm (16.8 in)
569 mm (22.4 in)
708 mm (27.9 in)
849 mm (33.4 in)
991 mm (39 in)
189 mm (7.4 in)
330 (13 in)
208.5 mm (8.2 in)
349.5 mm (13.8 in)
490.5 mm (13.3 in)
631.5 mm (24.9 in)
771.5 mm (30.4 in)
912.5 mm (35.9 in)
1054.5 mm (41.5 in)
1183.5 mm (46.4 in)
217 mm (8.5 in)
358 mm (14.1 in)
499 mm (19.6 in)
640 mm (25.2 in)
780 mm (30.7 in)
921 mm (36.2 in)
1063 mm (41.8 in)
1192 mm (46.9 in)
471 mm (18.5 in)
612 mm (24.1 in)
752 mm (29.6 in)
893 mm (35.2 in)
1035 mm (40.8 in)
1164 mm (45.8 in)
1120 mm (44.1 in)
Wiring Diagram
4-pin M12/Euro-style male QD
Pin
Wire Color Connection
1
3
4
brown
blue
12 to 30 V dc
dc common
1
4
2
3
black
Connect to 12 to 30 V dc for 50% maximum intensity. For maximum intensity, leave
the black wire floating or connected to common .
2
white
Not used
Banner Engineering Corp. Limited Warranty
Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or
replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not
cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO
BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES
RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT,
STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously
manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the
product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will
void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at
any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to:
www.bannerengineering.com.
For patent information, see www.bannerengineering.com/patents.
©
Banner Engineering Corp. All rights reserved
相关型号:
©2020 ICPDF网 联系我们和版权申明