295330101500 [BELDEN]

VFD, 3C 250MCM Str BC XLPO Ins #3 Symm. Seg.;
295330101500
型号: 295330101500
厂家: Belden    Belden
描述:

VFD, 3C 250MCM Str BC XLPO Ins #3 Symm. Seg.

文件: 总3页 (文件大小:244K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Product: 29533  
VFD, 3C 250MCM Str BC XLPO Ins + #3 Symm. Seg. Gnd (3 of #8) Str BC,  
CTS, Blk PVC Jkt, 2000V TC-ER 1000V CSA 22.2 No. 230 TC SUN RES OIL  
RES DIR BUR  
Product Description  
Belden Basics VFD, 3 Conductor 250MCM (37x.0822) Bare Copper XLPO Insulation M4 Color Code + 3AWG Symmetrical Segmented Ground (3 of 8AWG)  
Bare Copper Stranded, Overall Dual Copper Tapes Helically Applied Shield, Black PVC Outer Jacket, 2000V TC-ER 1000V CSA 22.2 No. 230 TC SUN RES  
DIR BUR Oil Resistant  
Technical Specifications  
Product Overview  
Suitable Applications:  
AC Motor drives, VFD, Variable Frequency drives  
Physical Characteristics (Overall)  
Conductor  
Element  
AWG  
Stranding  
Material  
No. of Conductors  
250 MCM 37x.0822 BC - Bare Copper  
3
Ground Wire  
8
7x16  
BC - Bare Copper  
3
Conductor Count:  
Insulation  
Material  
Nominal Wall Thickness  
XLPE - Cross Linked Polyethylene 0.105 in  
Outer Shield Material  
Type Layer  
Material  
Coverage [%]  
Tape  
Tape  
1
2
Spiral Copper 100 %  
Spiral Copper 100 %  
Outer Jacket Material  
Material  
Nominal Diameter  
PVC - Polyvinyl Chloride 1.912 in  
Electrical Characteristics  
Conductor DCR  
Nominal Conductor DCR  
0.05 Ohm/1000ft  
Capacitance  
Nom. Capacitance Conductor to  
Conductor  
Nom. Capacitance Conductor to Other Conductor to Shield  
54 pF/ft  
97 pF/ft  
Inductance  
Nominal Inductance  
0.136 µH/ft  
Impedance  
Nominal Characteristic Impedance  
44 Ohm  
Current  
Max. Recommended Current [A]  
290 Amps per conductor @ 30°C (per NEC)  
Voltage  
UL Voltage Rating  
2000 V RMS (Type TC)  
Temperature Range  
UL Temp Rating:  
90°C Dry, 90°C Wet  
-40°C To +90°C  
Operating Temp Range:  
Mechanical Characteristics  
Bulk Cable Weight:  
3730 lbs/1000ft  
6000 lbs  
Max Recommended Pulling Tension:  
Min Bend Radius/Minor Axis:  
34.4 in  
Standards  
NEC Articles:  
336 - ER  
NEC/(UL) Specification:  
CSA AWM Specification:  
TC-ER  
C22.2 #230 Type TC  
Applicable Environmental and Other Programs  
EU Directive 2000/53/EC (ELV):  
EU Directive 2003/96/EC (BFR):  
EU Directive 2011/65/EU (ROHS II):  
EU Directive 2012/19/EU (WEEE):  
EU Directive 2015/863/EU:  
Yes  
Yes  
Yes  
Yes  
Yes  
EU Directive Compliance:  
EU Directive 2003/11/EC (BFR)  
EU CE Mark:  
Yes  
EU RoHS Compliance Date (yyyy-mm-dd):  
CA Prop 65 (CJ for Wire & Cable):  
MII Order #39 (China RoHS):  
2012-06-11  
Yes  
Yes  
Suitability  
Suitability - Burial:  
Yes  
Yes  
Yes  
Yes  
Yes  
Suitability - Indoor:  
Suitability - Oil Resistance:  
Suitability - Outdoor:  
Suitability - Sunlight Resistance:  
Flammability, LS0H, Toxicity Testing  
UL Flammability:  
CSA Flammability:  
IEEE Flammability:  
UL voltage rating:  
UL1685 UL Loading  
FT4  
IEEE 1202, IEEE 383 Vertical Tray Flame Test (70,000 BTU)  
2000 V RMS (NEC Type TC)  
Plenum/Non-Plenum  
Plenum (Y/N):  
No  
Part Number  
Variants  
Item #  
Color  
UPC  
Length  
29533 0101500 Black 612825138334 1,500 m  
29533 0102000 Black 612825353140  
29533 0102300 Black 612825138341 2,300 ft  
History  
Update and Revision:  
Revision Number: 0.299 Revision Date: 09-10-2019  
© 2019 Belden, Inc  
All Rights Reserved.  
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without  
notice, and the listing of such information and specifications does not ensure product availability.  
Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages  
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,  
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.  
All sales of Belden products are subject to Belden's standard terms and conditions of sale.  
Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief  
at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product  
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and  
regulations based on their individual usage of the product.  

相关型号:

295330102000

VFD, 3C 250MCM Str BC XLPO Ins #3 Symm. Seg.
BELDEN

295330102300

VFD, 3C 250MCM Str BC XLPO Ins #3 Symm. Seg.
BELDEN

29534

VFD, 3C 350MCM Str BC XLPO Ins #2 Symm. Seg.
BELDEN

295340101500

VFD, 3C 350MCM Str BC XLPO Ins #2 Symm. Seg.
BELDEN

295340101750

VFD, 3C 350MCM Str BC XLPO Ins #2 Symm. Seg.
BELDEN

29535

VFD, 3C 500MCM Str BC XLPO Ins #2 Symm. Seg.
BELDEN

295350101300

VFD, 3C 500MCM Str BC XLPO Ins #2 Symm. Seg.
BELDEN

29536

VFD 300% Gnd, 3CIG #14 Str TC, XLPO InsPVC Gnd
BELDEN

295360101000

VFD 300% Gnd, 3CIG #14 Str TC, XLPO InsPVC Gnd
BELDEN

295360105000

VFD 300% Gnd, 3CIG #14 Str TC, XLPO InsPVC Gnd
BELDEN

29537

VFD 300% Gnd, 3CIG #12 Str TC, XLPO InsPVC Gnd
BELDEN

295370101000

VFD 300% Gnd, 3CIG #12 Str TC, XLPO InsPVC Gnd
BELDEN