22ADP-584B [BELIMO]

Differential Pressure Sensor Air;
22ADP-584B
型号: 22ADP-584B
厂家: BELIMO    BELIMO
描述:

Differential Pressure Sensor Air

文件: 总5页 (文件大小:568K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Technical data sheet  
22ADP-584..  
Differential Pressure Sensor Air  
Differential pressure transmitter with 8  
selectable ranges and outputs 0...5 V,  
0...10 V or 4...20 mA. For monitoring the  
differential pressure of air and other non-  
flammable and non-aggressive gases.  
Monitoring air filters, fans, industrial cooling  
air cycles, control of air and fire dampers.  
Options available with LCD display, auto-  
zero feature. IP65 / NEMA 4X rated  
enclosure.  
Type Overview  
Measuring range Measuring range Output signal  
Type  
Burst pressure  
Display type Additional features  
pressure  
pressure  
active pressure  
22ADP-584  
0...2500 Pa  
0...10 inch WC 0...5 V, 0...10 V,  
4...20 mA  
40 kPa /  
-
-
160 inch WC  
22ADP-584A  
22ADP-584B  
22ADP-584L  
0...2500 Pa  
0...2500 Pa  
0...2500 Pa  
0...10 inch WC 0...5 V, 0...10 V,  
4...20 mA  
40 kPa /  
-
Auto-Zero  
Auto-Zero  
-
160 inch WC  
0...10 inch WC 0...5 V, 0...10 V,  
4...20 mA  
40 kPa /  
LCD  
LCD  
160 inch WC  
0...10 inch WC 0...5 V, 0...10 V,  
4...20 mA  
40 kPa /  
160 inch WC  
Technical Data  
Electrical Data Nominal voltage  
Nominal voltage range  
AC/DC 24 V  
AC 19...29 V / DC 15...35 V  
Power consumption AC  
Power consumption DC  
Electrical connection  
1.7 VA  
1.1 W  
Removable spring loaded terminal block max.  
2.5 mm²  
Cable entry  
Cable gland with strain relief Ø6...8 mm (1/2"  
NPT conduit adapter included)  
Functional Data  
Sensor Technology  
Multirange  
piezo measuring element  
8 measuring ranges selectable  
Output signal active note  
Output 0...5/10 V selectable with switch  
Voltage output: min. 10 kΩ load  
current output: max. 500 Ω load  
Display  
LCD, 1.14x1.38" [29x35 mm]  
with backlight  
measured values: Pa, inchWC (configurable)  
Application  
air  
Response time  
adjustable 0.8 s or 4.0 s  
www.belimo.com  
22ADP-584.. • en-us • 2020-07-30 • Subject to change  
1 / 5  
Technical data sheet  
22ADP-584..  
Measuring Data Measuring values  
differential pressure  
Measuring fluid  
air and non-aggressive gases  
Measuring range settings pressure  
Setting range [Pa] range [inch WC] Factory  
setting  
S0  
S1  
S2  
S3  
S4  
S5  
S6  
S7  
0...2500  
0...2000  
0...1500  
0...1000  
0...500  
0...10  
0...8  
0...6  
0...4  
0...2  
0...250  
0...1  
0...100  
0...0.4  
-0.4...0.4  
-100...100  
Accuracy pressure  
measuring range ≤2 inch WC: ±0.02 inch WC  
measuring range >2 inch WC: ±0.04 inch WC  
Materials  
Cable gland  
Housing  
PA6, black  
cover: lexan, orange  
base: lexan, orange  
seal: 0467 NBR70, black  
UV resistant  
Safety Data  
Ambient humidity  
Ambient temperature  
Fluid temperature  
Protection class IEC/EN  
Protection class UL  
EU Conformity  
max. 95% r.H., non-condensing  
15...120°F [-10...50°C]  
15...120°F [-10...50°C]  
III Safety Extra-Low Voltage (SELV)  
UL Class 2 Supply  
CE Marking  
Certification IEC/EN  
Certification UL  
IEC/EN 60730-1 and IEC/EN 60730-2-6  
cULus acc. to UL60730-1A/-2-6, CAN/CSA  
E60730-1:02  
Degree of protection IEC/EN  
Degree of protection NEMA/UL  
Quality Standard  
IP65  
NEMA 4X  
ISO 9001  
Safety Notes  
This device has been designed for use in stationary heating, ventilation and air-conditioning  
systems and must not be used outside the specified field of application. Unauthorised  
modifications are prohibited. The product must not be used in relation with any equipment  
that in case of a failure may threaten humans, animals or assets.  
Ensure all power is disconnected before installing. Do not connect to live/operating  
equipment.  
Only authorised specialists may carry out installation. All applicable legal or institutional  
installation regulations must be complied during installation.  
The device contains electrical and electronic components and must not be disposed of as  
household refuse. All locally valid regulations and requirements must be observed.  
www.belimo.com  
22ADP-584.. • en-us • 2020-07-30 • Subject to change  
2 / 5  
Technical data sheet  
22ADP-584..  
Remarks  
Automated Zero-Point calibration (Auto- Transmitters equipped with the auto-zero calibration are maintenance-free.  
Zero)  
The auto-zero calibration electronically adjusts the transmitter zero every 10 minutes.The  
function eliminates all output signal drift due to thermal, electronic or mechanical effects.  
The auto-zero adjustment takes approx. 4 seconds after which the device returns to its  
normal measuring mode. During the 4 second adjustment period, the output and display  
values will freeze to the latest measured value.  
Manual Zero-Point Calibration In normal operation zero-point calibration should be executed every 12 months.  
Attention! For executing zero-point calibration the power supply must be connected one  
hour before.  
• Release both connection tubes from the pressure terminals + and -  
• Press the button until the LED lights permanently  
• Wait until the LED flashes again and reinstall the connection tubes to the pressure ports  
(note + and -)  
Scope of delivery  
Scope of delivery Description  
Mounting plate L housing  
Type  
A-22D-A10  
Duct connector kit, PVC tube 2 m, 2 connection elements (Plastic) for A-22AP-A08  
22ADP-..  
Dowel  
Screws  
1/2" NPT conduit adapter  
Accessories  
Optional accessories Description  
Type  
Duct connector, Metal, L 1.5", Tube connection 0.2"  
Duct connector, Metal, L 4", Tube connection 0.2"  
A-22AP-A01  
A-22AP-A03  
www.belimo.com  
22ADP-584.. • en-us • 2020-07-30 • Subject to change  
3 / 5  
Technical data sheet  
22ADP-584..  
Wiring Diagram  
① Button  
② Status LED  
Factory setting  
Pressure unit  
Response time  
Output signal  
*
P
T
U
Setting  
range [Pa]  
range [inch WC]  
Factory  
setting  
S0  
S1  
S2  
S3  
S4  
S5  
S6  
S7  
0...2500  
0...2000  
0...1500  
0...1000  
0...500  
0...10  
0...8  
0...6  
0...4  
0...2  
0...250  
0...1  
0...100  
0...0.4  
-0.4...0.4  
-100...100  
www.belimo.com  
22ADP-584.. • en-us • 2020-07-30 • Subject to change  
4 / 5  
Technical data sheet  
22ADP-584..  
Dimensions  
Type  
Weight  
22ADP-584  
22ADP-584A  
22ADP-584B  
22ADP-584L  
0.63 lb [0.29 kg]  
0.63 lb [0.29 kg]  
0.66 lb [0.30 kg]  
0.66 lb [0.30 kg]  
www.belimo.com  
22ADP-584.. • en-us • 2020-07-30 • Subject to change  
5 / 5  

相关型号:

22ADP-584L

Differential Pressure Sensor Air
BELIMO

22ADP-58Q

Differential Pressure Sensor Air
BELIMO

22ADP-58QA

Differential Pressure Sensor Air
BELIMO

22ADP-58QB

Differential Pressure Sensor Air
BELIMO

22ADP-58QL

Differential Pressure Sensor Air
BELIMO

22AF100-1

RF Connector Adapter, BNC-BNC, Panel Mount
AMPHENOL

22AR10KLFTR

3 mm Single Turn Sealed Surface Mount Cermet Trimming Potentiometer
TTELEC

22AT2-T

Toggle Switch, 8PDT, Latched, 5A, 30VDC, Wire Terminal, Steel Lever Actuator, Panel Mount-threaded
HONEYWELL

22AT21-T

Toggle Switch, 8PDT, Momentary, 5A, 30VDC, Wire Terminal, Lever Actuator, Panel Mount-threaded
HONEYWELL

22AT55-4-M

Toggle Switch, 4PDT, Latched And Momentary, 5A, 30VDC, Wire Terminal, Panel Mount-threaded
HONEYWELL

22AT72-S-E

Toggle Switch, 8PDT, Latched, 5A, 30VDC, Screw Terminal, Panel Mount-threaded
HONEYWELL

22B/-SERIES

Optoelectronic
ETC