22DT-54P 概述
Duct / Immersion Temperature Sensor
22DT-54P 数据手册
通过下载22DT-54P数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载Technical data sheet
22DT-54..
Duct / Immersion Temperature Sensor
Active sensor (4...20 mA) for measuring
temperature in duct applications. In
combination with a stainless steel or brass
thermowell can also be used for pipe
applications. IP65 / NEMA 4X rated
enclosure.
Type Overview
Output signal
Type
Probe length
Probe diameter
active temperature
22DT-54H
22DT-54L
22DT-54N
22DT-54P
22DT-54R
22DT-54T
4...20 mA
4...20 mA
4...20 mA
4...20 mA
4...20 mA
4...20 mA
2" [50 mm]
4" [100 mm]
6" [150 mm]
8" [200 mm]
12" [300 mm]
18" [450 mm]
0.24" [6 mm]
0.24" [6 mm]
0.24" [6 mm]
0.24" [6 mm]
0.24" [6 mm]
0.24" [6 mm]
Technical Data
Electrical Data Power supply DC
15...24 V, ±10%, 0.5 W
Electrical connection
Removable spring loaded terminal block max.
2.5 mm²
Cable entry
Cable gland with strain relief Ø6...8 mm (1/2"
NPT conduit adapter included)
Functional Data
Measuring Data
Multirange
8 measuring ranges selectable
Output signal active note
Application
current output: max. 500 Ω load
air
water
Measuring values
temperature
Measuring range temperature
Active sensor: range selectable
Attention: max. measuring temperature is
restricted by max. fluid temperature (see
Safety data)
Setting
range [°C]
range [°F] Factory
setting
S0
S1
S2
S3
S4
S5
S6
S7
-50...50°C
-10...120°C
0...50°C
-30...130°F
0...250°F
40...140°F
30...480°F
0...100°F
0...250°C
-15...35°C
0...100°C
-20...80°C
0...160°C
40...240°F
40...90°F
0...150°F
Accuracy temperature active
±0.9°F @ 70°F [±0.5°C @ 21°C]
Time constant t (63%) in the air duct
typical 46 s @ 3 m/s
typical 210 s @ 0 m/s
Time constant t (63%) in water pipe
typical 7 s with thermowell brass
typical 9 s with thermowell stainless steel
www.belimo.com
22DT-54.. • en-us • 2019-08-20 • Subject to change
1 / 5
Technical data sheet
22DT-54..
Materials Cable gland
PA6, black
Housing
cover: lexan, orange
base: lexan, orange
seal: 0467 NBR70, black
UV resistant
Safety Data
Ambient humidity
max. 95% r.H., non-condensing
-30...120°F [-35...50°C]
-60...320°F [-50...160°C]
max. 160°F [70°C]
Ambient temperature
Fluid temperature
Housing surface temperature
Protection class IEC/EN
Protection class UL
EU Conformity
III protective extra-low voltage (pelv)
UL Class 2 Supply
CE Marking
Certification IEC/EN
Certification UL
IEC/EN 60730-1
cULus acc. to UL60730-1A/-2-9, CAN/CSA
E60730-1:02/-2-9
Degree of protection IEC/EN
Quality Standard
IP65
ISO 9001
Safety Notes
This device has been designed for use in stationary heating, ventilation and air-conditioning
systems and must not be used outside the specified field of application. Unauthorised
modifications are prohibited. The product must not be used in relation with any equipment
that in case of a failure may threaten humans, animals or assets.
Ensure all power is disconnected before installing. Do not connect to live/operating
equipment.
Only authorised specialists may carry out installation. All applicable legal or institutional
installation regulations must be complied during installation.
The device contains electrical and electronic components and must not be disposed of as
household refuse. All locally valid regulations and requirements must be observed.
Remarks
General Remarks Concerning Sensors When using lengthy connection wires (depending on the cross section used) the measuring
result might be falsified due to a voltage drop at the common GND-wire (caused by the
voltage current and the line resistance). In this case, 2 GND-wires must be wired to the
sensor - one for supply voltage and one for the measuring current.
Sensing devices with a transducer should always be operated in the middle of the
measuring range to avoid deviations at the measuring end points. The ambient temperature
of the transducer electronics should be kept constant. The transducers must be operated at
a constant supply voltage (±0.2 V). When switching the supply voltage on/off, onsite power
surges must be avoided.
Build-up of Self-Heating by Electrical Temperature sensors with electronic components always have a dissipative power which
Dissipative Power affects the temperature measurement of the ambient air. The dissipation in active
temperature sensors shows a linear increase with rising operating voltage. This dissipative
power should be taken into account when measuring temperature. As Belimo transducers
work with a variable operating voltage, only one operating voltage can be taken into
consideration, for reasons of production engineering. Transducers 0...10 V / 4...20 mA have
a standard setting at an operating voltage of DC 24 V. That means, that at this voltage, the
expected measuring error of the output signal will be the least. For other operating voltages,
the offset error will be increased by a changing power loss of the sensor electronics. If a re-
calibration should become necessary later directly on the sensor, this can be done by
means of a trimming potentiometer on the sensor board.
www.belimo.com
22DT-54.. • en-us • 2019-08-20 • Subject to change
2 / 5
Technical data sheet
22DT-54..
Scope of delivery
Accessories
Scope of delivery Description
Type
A-22D-A11
Mounting clip, with screws and adhesive foil
1/2" NPT conduit adapter
Optional accessories Description
Type
Mounting plate S housing
A-22D-A09
A-22P-A51
A-22G-A01.1
Cold barrier, Plastic, L 50 mm, for thermowell pocket A-22P-A..
Connection adapter, M20, for cable 1 x 6 mm, Multipack 10 pcs.
Optional accessories air Description
Type
Mounting flange for sensor probe 6 mm, up to max. 80°C, Plastic
Mounting flange for sensor probe 6 mm, up to max. 260°C, Brass
A-22D-A03
A-22D-A05
Recommended accessories water Description
Type
Thermowell pocket (fabricated) Stainless steel, 2" [50 mm], 1/2" NPT, A-22P-A05
wrench size 3/4"
Thermowell pocket (fabricated) Brass, 2" [50 mm], 1/2" NPT, wrench
size 3/4"
A-22P-A17
Thermowell pocket (machined) Stainless steel, 2" [50 mm], 1/2" NPT, A-22P-A36
wrench size 3/4"
Thermowell pocket (fabricated) Stainless steel, 4" [100 mm], 1/2" NPT, A-22P-A07
wrench size 3/4"
Thermowell pocket (fabricated) Brass, 4" [100 mm], 1/2" NPT, wrench A-22P-A19
size 3/4"
Thermowell pocket (machined) Stainless steel, 4" [100 mm], 1/2" NPT, A-22P-A37
wrench size 3/4"
Thermowell pocket (fabricated) Stainless steel, 6" [150 mm], 1/2" NPT, A-22P-A09
wrench size 3/4"
Thermowell pocket (fabricated) Brass, 6" [150 mm], 1/2" NPT, wrench A-22P-A21
size 3/4"
Thermowell pocket (machined) Stainless steel, 6" [150 mm], 1/2" NPT, A-22P-A38
wrench size 3/4"
Thermowell pocket (fabricated) Stainless steel, 8" [200 mm], 1/2" NPT, A-22P-A11
wrench size 3/4"
Thermowell pocket (fabricated) Brass, 8" [200 mm], 1/2" NPT, wrench A-22P-A23
size 3/4"
Thermowell pocket (machined) Stainless steel, 8" [200 mm], 1/2" NPT, A-22P-A39
wrench size 3/4"
Thermowell pocket (fabricated) Stainless steel, 12" [300 mm], 1/2" NPT, A-22P-A13
wrench size 3/4"
Thermowell pocket (fabricated) Brass, 12" [300 mm], 1/2" NPT, wrench A-22P-A25
size 3/4"
Thermowell pocket (fabricated) Stainless steel, 18" [450 mm], 1/2" NPT, A-22P-A15
wrench size 3/4"
Thermowell pocket (fabricated) Brass, 18" [450 mm], 1/2" NPT, wrench A-22P-A27
size 3/4"
Syringe with thermal paste
A-22P-A44
www.belimo.com
22DT-54.. • en-us • 2019-08-20 • Subject to change
3 / 5
Technical data sheet
22DT-54..
Wiring Diagram
The adjustment of the measuring ranges is made by changing the bonding jumpers.
The output value in the new measuring range is available after 2 seconds.
Setting
range [°C]
range [°F]
Factory
setting
S0
S1
S2
S3
S4
S5
S6
S7
-50...50°C
-10...120°C
0...50°C
-30...130°F
0...250°F
40...140°F
30...480°F
0...100°F
40...240°F
40...90°F
0...150°F
0...250°C
-15...35°C
0...100°C
-20...80°C
0...160°C
www.belimo.com
22DT-54.. • en-us • 2019-08-20 • Subject to change
4 / 5
Technical data sheet
22DT-54..
Dimensions
Dimensions
L = Probe length
.
Type
Probe length
2" [50 mm]
Weight
22DT-54H
22DT-54L
22DT-54N
22DT-54P
22DT-54R
22DT-54T
0.26 lb [0.12 kg]
0.29 lb [0.13 kg]
0.29 lb [0.13 kg]
0.31 lb [0.14 kg]
4" [100 mm]
6" [150 mm]
8" [200 mm]
12" [300 mm] 0.33 lb [0.15 kg]
18" [450 mm] 0.35 lb [0.16 kg]
www.belimo.com
22DT-54.. • en-us • 2019-08-20 • Subject to change
5 / 5
22DT-54P 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
22DT-54R | BELIMO | Duct / Immersion Temperature Sensor | 获取价格 | |
22DT-54T | BELIMO | Duct / Immersion Temperature Sensor | 获取价格 | |
22E05-230 | ETC | Analog IC | 获取价格 | |
22E05D | ETC | Analog IC | 获取价格 | |
22E05D230 | ETC | Analog IC | 获取价格 | |
22E10A | ETC | Analog IC | 获取价格 | |
22E10A230 | ETC | Analog IC | 获取价格 | |
22E15-230 | ETC | Analog IC | 获取价格 | |
22E30-230 | ETC | Analog IC | 获取价格 | |
22E50-230 | ETC | Analog IC | 获取价格 |
22DT-54P 相关文章
- 2024-09-20
- 5
- 2024-09-20
- 9
- 2024-09-20
- 8
- 2024-09-20
- 6