OHV12-1.0K1500P [BELLNIX]

Ultracompact, Adjustable Output High-Voltage Power Supply 1.5Watt Medium-High Voltage DC-DC Converter;
OHV12-1.0K1500P
型号: OHV12-1.0K1500P
厂家: Bellnix    Bellnix
描述:

Ultracompact, Adjustable Output High-Voltage Power Supply 1.5Watt Medium-High Voltage DC-DC Converter

文件: 总5页 (文件大小:290K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Ultracompact, Adjustable Output High-Voltage Power Supply  
1.5Watt Medium-High Voltage DC-DC Converter  
1000V, 1500V, 2000V OHV Series  
The OHV series is our new line of medium-high voltage DC-DC converters featuring an ultracompact size with the footprint reduced  
by about 60% as compared to conventional models.  
With a pentahedron metal shield case, ripple noise has been reduced to as low as 10mVp-p. Output voltage can be adjusted by  
external voltage or external variable resistor. The built-in short circuit and overcurrent protection provide high reliability and a long  
life.  
Features  
Ultralow ripple noise 10mVp-p  
World's smallest size (about a 60%  
reduction from comparable  
conventional models)  
ON/OFF Control  
Adjustable voltage by variable resistor or  
external voltage  
Adjustable output voltage from 0 to  
100%  
Use of pentahedron metal shield case  
PCB mount type  
Control voltage 0 to +6V  
Built-in over current protection circuit High reliability and long life  
Output capacity 1.5W  
Supports 24V input with an external DC-DC converter  
Model/Standard  
Models  
OHV Series  
Load Resistance  
(KΩ) min  
Input I  
(A) typ  
Input V  
(Vdc)  
Output V  
(Vdc) *1  
Output I  
(mA)  
Ripple Noise  
(mVp-p) typ  
OHV12-1.0K1500P  
OHV12-1.0K1500N  
OHV12-1.5K1000P  
OHV12-1.5K1000N  
OHV12-2.0K700P  
OHV12-2.0K700N  
0.28  
0.28  
0.28  
0.28  
0.28  
0.28  
11.0-13.0  
11.0-13.0  
11.0-13.0  
11.0-13.0  
11.0-13.0  
11.0-13.0  
0 to +1000  
0 to -1000  
0 to +1500  
0 to -1500  
0 to +2000  
0 to -2000  
0-1.5  
0-1.5  
0-1.0  
666.7  
666.7  
1500  
1500  
2857  
2857  
5
5
7
7
10  
10  
0-1.0  
0-0.7  
0-0.7  
Note 1: See P5 on how to use with a 24V input voltage.  
Specifications  
Line regulation  
0.01% typ. (for a line regulation of 11.0 to 13.0V)  
Load regulation  
0.02% typ. (for a load current regulation of 0 to 100%)  
Temperature regulation  
Over current protection  
Output voltage setting accuracy  
70ppm/°C typ. (for temperature regulation of -10°C to +50°C)  
Drooping characteristic, built-in automatic return circuit, activated at 105% or more  
±2% or less (when controlling a 6.0V external voltage)  
Output voltage control  
ON/OFF control  
Either with 0V to +6V external voltage or a 5KΩ external variable resistor  
Between 2pin and 5pin, OFF when opened and ON when short-circuited  
-10°C to +50°C (no temperature derating needed  
-25°C to +85°C  
Operating temp range  
Storage temp range  
Operating humidity range  
20% to 95% RH (no condensation)  
Isolation between input and  
output  
Non-isolated type (2pin through 6pin are connected inside)  
MTBF expectation  
Min. 390,000 to 400,000H (calculated from Bellnix MTBF calculation table)  
Note 2 Output voltage is controlled by applying Vcont voltage. Apply voltage to the Vcont terminal by either variable resistor or external voltage to control output voltage.  
Note 2 When Vcont voltage is zero, output voltage (output residual voltage) will be within 0.5% of maximum output voltage (input/output rating).  
Note 3 Details are subject to change for improvement, etc., without prior notice.  
Test circuit  
Block diagram  
OHV  
1
7
+Vin  
Vout (+ or -  
+Vin  
Vout (+ or -  
High-voltage  
oscillation  
transformer  
DC-AC  
converter  
High-voltage  
rectifier  
1
+
7
12V  
C1  
Load  
+
Control IC  
CASE  
-Vin  
Load  
12V  
Output voltage control circuit  
Over current protection circuit  
Reference voltage generator  
Com (Vout)  
6
2
Vref  
4
SW1  
ON/OFF  
5
Vcont  
3
-Vin  
2
C1=47μF  
6
Open=OFF  
Short=ON  
SW1  
Com(Vout)  
(OPEN)  
Voltage detection circuit  
+
case  
ON/OFF  
Output voltage control  
(0V to 6V applied)  
Control  
SW1  
Open=OFF  
Short=ON  
(1) The input-output ground lines and the case are connected  
(1) internally.  
(2) Vref is 6V (when external VR is 5KΩ)  
(3) ON/OFF can be controlled by a transistor.  
Vcont  
External voltage (0 to 6V)  
ON/OFF  
5
Vref  
4
3
+
or  
VR 5kΩ)  
1
BHV20120208  
Shape, dimensions and terminal composition  
44.0±0.5  
16.0  
Pin-NO.  
Pin name  
+Vin  
1
2
3
4
5
6
7
-Vin  
Vcont  
Vref  
ON/OFF  
Com (Vout)  
Vout (+ or -)  
Weight: TBD  
Unit: mm  
2.0  
0.5  
Unspecified dimensional tolerance ±0.5  
Lot indication  
1) Terminal  
7-0.64L=4.2 min  
Material: Phosphor bronze  
Treatment: Ni base Au plating  
2) Case  
35.5  
Material: Brass  
Treatment: Nickel plating  
5.08 7.62  
±0.3 ±0.3  
7.62  
±0.3  
2×CASE PIN  
2.54±0.1  
2.54×4=10.16  
Standard method of use  
ON/OFF Control  
Output voltage can be turned ON/OFF by closing/opening between the  
ON/OFF terminal and -Vin terminal.  
OHV  
1
7
+Vin  
Vout (+ or -  
ꢀꢀꢀꢀBetween ON/OFF terminal (5) and -Vin terminal (2)  
ꢀꢀꢀꢀ(1) Output OFF when opened  
+
Load  
12V  
C1  
ꢀꢀꢀꢀ(2) Output ON when short-circuited (0 - 0.4V, 1mA max.)  
CASE  
-Vin  
As the ON/OFF terminal is pulled up to +Vin inside the power supply,  
pay attention to the voltage of elements (photocoupler, transistor, etc.)  
to switch the ON/OFF terminal.  
Com (Vout)  
Vref  
6
2
SW1  
ON/OFF  
5
Vcont  
C1=47μF  
Open=OFF  
Short=ON  
SW1  
4
3
(OPEN)  
Short-circuit when ON/OFF is not controlled.  
+
Output voltage control  
(0V to 6V applied)  
ON/OFF  
(5)  
ON/OFF  
(5)  
The OHV series does not basically require  
additional parts, but add capacitor C1 to the input  
terminal if input impedance is high due to a long  
distance between the power supply and converter,  
the input line is thin, a filter is inserted on the input  
side, etc. When fitting a capacitor, try to add on  
the converter terminal side so as to reduce lead  
inductance.  
(2)  
-Vin  
(2)  
-Vin  
Non-isolated type  
Isolated type  
Ensure that there is no chattering to the ON/OFF terminal which affects  
output voltage. Output residual voltage is 0.5% or less when output is  
OFF under ON/OFF control (at the rated input-output).  
2
BHV20120208  
Bellnix High Voltage DC-DC Converters  
Overcurrent protection circuit  
Setting and adjustment of output voltage  
The OHV series has a built-in over current  
protection circuit against overload and load short-  
circuit. The circuit reduces output voltage in case  
of overload or load short-circuit and automatically  
returns the output to normal when the cause is  
eliminated.  
The output voltage of the OHV series can be set and adjusted by  
external voltage and external variable resistor.  
OHV  
1
7
Vout (+ or -)  
Com (Vout)  
+Vin  
+
12V  
SW1  
Load  
C1  
10  
0
CASE  
-Vin  
100% output  
80  
6
2
Vref  
ON/OFF  
5
Vcont  
3
C1=47μF  
Open=OFF  
Short=ON  
60  
SW1  
4
(OPEN)  
50% output  
40  
+
Output voltage control  
(0V to 6V applied)  
20  
0
0
Output current (lo)  
100%  
OHV series over current protection  
circuit characteristic  
Output voltage VR resistance characteristic  
100%  
80%  
60%  
40%  
20%  
0%  
The overcurrent protection circuit shows a  
drooping characteristic. Ensure that the load to be  
used is at least with the minimum resistance  
specified for each series.  
R15kΩ  
R20kΩ  
0kΩ  
5kΩ  
VR resistance  
Recommended pattern  
[Top View]  
17.75  
17.75  
Output voltage output control voltage characteristic  
100%  
80%  
60%  
40%  
20%  
0%  
1.5V  
3V  
6V  
0V  
4.5V  
2.54±0.1  
2.54×4=10.16  
5.08  
±0.3  
7.62  
±0.3  
7.62  
±0.3  
Output control voltage  
In the above characteristic graph (output voltage - VR  
resistance characteristic), the resistance R1 and R2  
are a guideline. When setting output at a fixed voltage  
with a fixed resistor, do so after determining R1 and  
R2 using a variable resistor.  
7-ꢀꢀ Hole dia. : φ1.2  
2-ꢀꢀ Hole dia. : φ2.5  
[mm]  
(i)  
The OHV series uses a metal case. When mounting  
onto a double-sided board, wiring to this converter  
should be on a soldered surface. When wiring, pay  
enough attention to creepage distance because of  
the high voltage of this converter.  
Do not apply 6V+3% or more voltage to Vcont.  
Use a variable resistor with a good temperature coefficient.  
(ii)  
When mounting onto a double-sided board, make  
the land on the parts surface of the high voltage  
output terminal as small as possible.  
It is preset that when the resistance of the variable  
resistor is 5.0KΩ, 6.0V is applied to the Vcont terminal  
to obtain 100% output voltage. Since the tolerance of  
the resistance value largely affects the maximum  
output voltage, set the resistance value at 5.0KΩ±5%.  
(iii)  
Connect the case of the OHV series to -Vin or Com.  
Try to reduce impedance to the ground as much as  
possible.  
3
BHV20120208  
Description of Vref terminal  
(reference voltage output)  
Recommended soldering conditions  
This terminal is used for controlling output voltage  
with a variable resistor. Vref outputs a reference  
voltage of 6V. A 5KΩ external resistor is used in  
Observe the following conditions for soldering each part.  
(i) Soldering iron  
340 - 360°C  
230 - 260°C  
5 seconds  
(ii) Dip solder bath  
10 seconds  
this case.  
Since resistance value (tolerance) of an external  
resistor affects the Vref terminal voltage preset  
value and determines output voltage, ensure that  
the resistor has high accuracy of 5KΩ±5%. The  
type of the variable resistor (5KΩ) does not matter,  
but those of a good temperature coefficient are  
recommended.  
To reduce output noise further  
The OHV series basically does not require any additional parts,  
but to reduce output noise further, add Capacitor C2 as shown  
below.  
OHV  
Vref voltage: 6±0.3V  
1
7
Vout (+ or -)  
+Vin  
Reference voltage  
generating circuit  
+
OHV series  
12V  
C1  
Load  
C2  
Vout (com)  
6
CASE  
-Vin  
Com (Vout)  
6
2
Vref  
Vcont  
4
3
Vref  
SW1  
ON/OFF  
5
Vcont  
3
C1=47μF  
Open=OFF  
Short=ON  
SW1  
4
C2=0.047 to 0.1μF  
(OPEN)  
+
External variable resistor (5.0KΩ)  
Output voltage control  
(0V to 6V applied)  
Temperature derating  
To reduce output noise even further, position C2 near the Load  
with the shortest input-output wiring while paying attention to  
creepage and spatial distances .  
Can be activated in this area but without  
performance warranty.  
100  
80  
Point!  
(i)  
Add a capacitor of a good high frequency  
characteristic to the input side.  
(ii) Design a pattern for the ground (common) line to be  
60  
40  
20  
0
thick and short so as to reduce common impedance.  
(iii) Ensure that a capacitor to add to the output side shall  
have a sufficient withstand voltage and shall be  
attached to the terminal end. Try to make the lead  
wires of the capacitor the shortest possible in this case  
as well. In addition, with a load requiring a  
certain response speed, pay attention to the time  
-20 -10  
0
+10 +20 +30 +40 +50  
Ambient temperature (°C)  
Protection against reverse connection  
Reverse connection of input voltage may result in the breakage of a  
converter. If there is any possibility for a reverse connection, add a  
diode and a fuse to the input terminal as shown below.  
Fuse  
+Vin  
-Vin  
+
OHV  
12V  
4
BHV20120208  
Bellnix High Voltage DC-DC Converters  
How to use for a 24V input voltage  
By connecting a 24V-input 12V-output DC-DC converter to the  
front of the OHV series, the OHV series can be used for a 24V  
input voltage.  
External DC-DC converter  
Circuit diagram of 12V input  
24V  
12V  
Vin  
Vout  
+Vin  
Vout (+ or -  
+
DC/DC  
C1  
C2  
C3  
OHV  
GND  
CASE  
-Vin  
Com (Vout)  
Vref  
ON/OFF  
Vcont  
SW1  
(OPEN)  
+
Output voltage control  
ꢀꢀꢀ ꢀꢀExamples of DC-DC converters  
Model  
Vout [V]  
Iout [mA]  
Isolation  
Vin [V]  
R-7812-0.5  
Non-isolated type  
Non-isolated type  
Non-isolated type  
15 to 32  
7 to 36  
12  
500  
600  
BSS-05S0R6A  
BSS-12S2R5A  
BSA24-12S1R0  
REC6-2412SRW/R/A  
RPP20-2412S  
3.3 to 24  
15 to 36 9.5 to 15  
2500  
1000  
500  
Non-isolated type  
Isolated type  
Isolated type  
Isolated type  
Isolated type  
18 to 36  
18 to 36  
18 to 36  
18 to 36  
18 to 36  
9 to 12  
12  
12  
1666  
500  
BTC24-12S50  
12  
BTD24-12S100  
12  
1000  
When selecting a front DC-DC converter, the following shall  
be borne in mind.  
Select a DC-DC converter compatible to the OHV series  
in its input power.  
Pay attention to the temperature derating in selecting a  
DC-DC converter.  
For C1 and C2, use capacitors recommended in the data  
sheet of the DC-DC converter concerned.  
Always check the data sheet of a DC-DC converter before  
use.  
Warranty  
The warranty term of the product is one year after  
shipment. Should the product become defective  
within the warranty period due to our design or  
workmanship, the product will be repaired free of  
charge or replaced. However, this warranty does not  
cover products which have been subjected to  
unauthorized inner modifications, etc.  
The scope of our warranty is limited to that of the  
said product.  
Contact  
If you have any further technical questions for this  
product, please contact us.  
E-mail: info@bellnix.com  
URL: http://www.bellnix.com  
5
BHV20120208  

相关型号:

OHV12-1.5K1000N

Ultracompact, Adjustable Output High-Voltage Power Supply 1.5Watt Medium-High Voltage DC-DC Converter
BELLNIX

OHV12-1.5K1000P

Ultracompact, Adjustable Output High-Voltage Power Supply 1.5Watt Medium-High Voltage DC-DC Converter
BELLNIX

OHV12-2.0K700N

Ultracompact, Adjustable Output High-Voltage Power Supply 1.5Watt Medium-High Voltage DC-DC Converter
BELLNIX

OHV12-2.0K700P

Ultracompact, Adjustable Output High-Voltage Power Supply 1.5Watt Medium-High Voltage DC-DC Converter
BELLNIX

OHWG

OHWG Series Wiegand sensor
OHHALLSENSOR

OHWG112

OHWG Series Wiegand sensor
OHHALLSENSOR

OHWG113

OHWG Series Wiegand sensor
OHHALLSENSOR

OHWG113A

OHWG Series Wiegand sensor
OHHALLSENSOR

OHWG115

OHWG Series Wiegand sensor
OHHALLSENSOR

OHWG214

OHWG Series Wiegand sensor
OHHALLSENSOR

OHWG311

OHWG Series Wiegand sensor
OHHALLSENSOR

OHWG312

OHWG Series Wiegand sensor
OHHALLSENSOR