110IMX7-03-9M [BEL]

DC-DC Regulated Power Supply Module, 1 Output, 7W, Hybrid;
110IMX7-03-9M
型号: 110IMX7-03-9M
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

DC-DC Regulated Power Supply Module, 1 Output, 7W, Hybrid

文件: 总18页 (文件大小:175K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Board Mountable  
DC-DC Converters  
IMX 7 Series  
7 Watt DC-DC Converters  
IMX 7 Series  
Wide input voltage ranges up to 150 V DC  
1 or 2 outputs up to 48 V DC  
1500...2500 V DC I/O electric strength test  
• Extremely wide input voltage ranges  
• Electrical isolation, also between outputs  
• Emissions below EN 55 022 level B.  
• Immunity to IEC/EN 61000-4-2, -3, -4, -5 and -6  
• High efficiency (typ. 84%)  
10.5  
0.42"  
25.4  
1.0"  
50.8  
2.0"  
• Inhibit input, output voltage adjustable  
• Flex power: flexible load distribution on outputs  
• Outputs no-load, overload and short-circuit proof  
• Operating ambient temperature up to –40...85°C  
• High reliability and no derating  
• 2" × 1" case with 10.5 mm profile  
• Supplementary insulation  
Safety according to IEC/EN 60950, UL 1950  
1
LGA  
1 For 70/110 IMX types  
Summary  
The IMX 7 series of board mountable 7 Watt DC-DC con-  
verters has been designed according to the latest industry  
requirements and standards.The converters are particularly  
suitable for use in mobile or stationary applications in trans-  
port, railways, industry or telecommunications where vari-  
able input voltages or high transient voltages are prevalent.  
60 V DC. They are designed and built according to the inter-  
national safety standards IEC/EN 60950, UL 1950, CAN/  
CSA C22.2 No.950-95 and are LGA and UL marked. The  
70 IMX 7 and 110 IMX 7 types are CE marked.  
The circuit comprises of integrated planar magnetics and  
all components are automatically assembled and solidly  
soldered onto a single PCB without any wire connections.  
Magnetic feedback ensures maximum reliability and re-  
peatability in the control loop over all operating conditions.  
Careful considerations of possible thermal stresses ensure  
the absence of hot spots providing long life in environments  
where temperature cycles are a reality. The thermal design  
allows operation at full load up to an ambient temperature  
of 85°C in free air without using any potting material. For  
extremely high vibration environments the case has holes  
for screw mounting.  
Covering a total input voltage range from 8.4 V DC up to  
150 V DC with four different types the units are available  
with single and electrically isolated double outputs allowing  
the configuration of output voltages from 3.3 V DC up to  
48 V DC externally adjustable, with flexible load distribution  
on double output units. An inhibit input allows remote con-  
verter on/off.  
Features include efficient input and output filtering with un-  
surpassed transient and surge protection, low output ripple  
and noise, consistently high efficiency over the entire input  
voltage range, high reliability as well as excellent dynamic  
response to load and line changes.  
Various options as e.g. extended temperature range  
40...85°C, industrial C pinout or SMD pinout provide a  
high level of application specific engineering and design-in  
flexibility.  
The converters provide supplementary insulation with  
SELV outputs as e.g. required in battery supported sys-  
tems where the bus voltage may exceed the SELV limit of  
Table of Contents  
Page  
Page  
Summary .......................................................................... 1  
Type Survey and Key Data .............................................. 2  
Type Key .......................................................................... 3  
Functional Description ..................................................... 4  
Electrical Input Data ......................................................... 5  
Electrical Output Data ...................................................... 7  
Auxiliary Functions ......................................................... 10  
Electromagnetic Compatibility (EMC) ............................ 12  
Immunity to Environmental Conditions .......................... 13  
Mechanical Data ............................................................ 14  
Safety and Installation Instructions ................................ 15  
Description of Options.................................................... 17  
Edition 4/04.2001  
1/18  
Board Mountable  
DC-DC Converters  
IMX 7 Series  
Type Survey and Key Data  
Table 1: Type survey  
Output 1  
Output 2  
Output Power  
Po nom  
Input voltage  
range  
Efficiency  
Type  
designation  
Options 2  
Uo1 nom Io1 nom Uo2 nom Io2 nom  
htyp  
[%]  
[V DC]  
[A] 1  
[V DC]  
[A] 1  
[W]  
[V DC]  
3.3  
3.3  
3.3  
3.3  
1.5  
1.5  
1.5  
1.5  
-
-
-
-
-
-
-
-
5
5
5
5
8.4...36  
16.8...75 3  
40...121  
60...150  
79  
81  
79  
79  
20 IMX 7-03-9  
40 IMX 7-03-9  
70 IMX 7-03-9  
110 IMX 7-03-9  
-8, M, C, L, Z  
-8, M, C, L, Z  
-8, M  
-8, M  
5.1  
5.1  
5.1  
5.1  
1.2  
1.2  
1.2  
1.2  
-
-
-
-
-
-
-
-
6.1  
6.1  
6.1  
6.1  
8.4...36  
16.8...75 3  
40...121  
60...150  
80  
81  
80  
80  
20 IMX 7-05-9  
40 IMX 7-05-9  
70 IMX 7-05-9  
110 IMX 7-05-9  
-8, M, C, L, Z  
-8, M, C, L, Z  
-8, M  
-8, M  
12  
12  
0.5  
0.6  
-
-
-
-
6
7.2  
8.4...36  
16.8...75 3  
84  
84  
20 IMX 7-12-9C  
40 IMX 7-12-9C  
-8  
-8  
15  
15  
0.4  
0.48  
-
-
-
-
6
7.2  
8.4...36  
16.8...75 3  
84  
84  
20 IMX 7-15-9C  
40 IMX 7-15-9C  
-8  
-8  
24  
24  
0.26  
0.3  
-
-
-
-
6.2  
7.2  
8.4...36  
16.8...75 3  
84  
84  
20 IMX 7-24-9C  
40 IMX 7-24-9C  
-8  
-8  
5
5
5
5
0.6  
0.7  
0.7  
0.7  
5
5
5
5
0.6  
0.7  
0.7  
0.7  
6
7
7
7
8.4...36  
16.8...75 3  
40...121  
60...150  
82  
83  
82  
82  
20 IMX 7-05-05-9  
40 IMX 7-05-05-9  
70 IMX 7-05-05-9  
110 IMX 7-05-05-9  
-8, M, C, L, Z  
-8, M, C, L, Z  
-8, M  
-8, M  
12  
12  
12  
12  
0.25  
0.3  
0.3  
12  
12  
12  
12  
0.25  
0.3  
0.3  
6
8.4...36  
16.8...75 3  
40...121  
60...150  
84  
84  
83  
84  
20 IMX 7-12-12-9  
40 IMX 7-12-12-9  
70 IMX 7-12-12-9  
110 IMX 7-12-12-9  
-8, M, C, L, Z  
-8, M, C, L, Z  
-8, M  
7.2  
7.2  
7.2  
0.3  
0.3  
-8, M  
15  
15  
15  
15  
0.2  
15  
15  
15  
15  
0.2  
6
8.4...36  
16.8...75 3  
40...121  
60...150  
84  
84  
83  
84  
20 IMX 7-15-15-9  
40 IMX 7-15-15-9  
70 IMX 7-15-15-9  
110 IMX 7-15-15-9  
-8, M, C, L, Z  
-8, M, C, L, Z  
-8, M  
0.24  
0.24  
0.24  
0.24  
0.24  
0.24  
7.2  
7.2  
7.2  
-8, M  
24  
24  
24  
24  
0.13  
0.15  
0.15  
0.15  
24  
24  
24  
24  
0.13  
0.15  
0.15  
0.15  
6.2  
7.2  
7.2  
7.2  
8.4...36  
16.8...75 3  
40...121  
60...150  
84  
84  
83  
84  
20 IMX 7-24-24-9  
40 IMX 7-24-24-9  
70 IMX 7-24-24-9  
110 IMX 7-24-24-9  
-8, M, C, L, Z  
-8, M, C, L, Z  
-8, M  
-8, M  
1 Flexible load distribution on double outputs possible.  
2 See table: Survey of options.  
3 Operation at lower input voltage possible: Po approx. 80% of Po nom at Ui min = 14.4 V.  
Edition 4/04.2001  
2/18  
Board Mountable  
DC-DC Converters  
IMX 7 Series  
Type Key  
20 IMX 7 - 05 - 05 -9 M C L Z ..  
Input voltage range Ui  
8.4...36 V DC ............................................ 20  
16.8...75 V DC ............................................ 40  
40...121 V DC ............................................ 70  
60...150 V DC .......................................... 110  
Series ........................................................................ IMX 7  
Output voltage type output 1 .................. 03, 05, 12, 15, 24  
Dash:  
Designates double output unit with two  
independent electrically isolated outputs ...... -  
1
3
Output voltage type output 2 ........................ 05, 12, 15, 24  
Operating ambient temperature range TA  
40...71°C .................................................. -9  
40...85°C (option) ..................................... -8  
2 3  
2 3  
2 3  
2
Options:  
Surface mount version with pins ................. M  
C-pinout ...................................................... C  
Surface mount version with PCB lid ............ L  
Open frame .................................................. Z  
1 Not applicable for option C.  
2 Option M, L, C and Z exclude each other.  
3 For delivery lead times and minimum order quantity contact Power-One.  
Examples: 40 IMX 7-05-05-9M: DC-DC converter, input voltage range 16.8...75 V, 2 electrically isolated outputs each  
providing 5 V, 700 mA, surface mount version.  
20 IMX 7-0505-9C: DC-DC converter, input voltage range 8.4...36 V, C pinout with outputs ±5 V, 600 mA.  
20 IMX 7-12-9C: DC-DC converter, input voltage range 8.4...36 V, C pinout with one output 12 V, 500 mA.  
Edition 4/04.2001  
3/18  
Board Mountable  
DC-DC Converters  
IMX 7 Series  
Functional Description  
In the case of the dual and double output units the output  
voltage is monitored by a separate transformer winding  
close to the secondary windings and fed back to the control  
circuit. The R (Trim) input is referenced to the primary side  
and allows programming of the output voltage in the range  
100 to 105% of Uo nom by an external resistor or within 75 to  
105% of Uo nom using an external voltage source.  
The IMX 7 DC-DC modules are feedback controlled flyback  
converters using current mode PWM (Pulse Width Modula-  
tion). See block diagram for single and double output types.  
In the case of the single output units the output is directly  
monitored and fed back to the primary control circuit via a  
pulse transformer, resulting in tight regulation of the output  
voltage. The R input is referenced to the secondary side  
and allows for programming of the output voltages in the  
range 75 to 105% of Uo nom using either an external resistor  
or an external voltage source.  
Current limitation is provided by the primary circuit, thus  
limiting the total output power.  
The inhibit input allows remote converter on/off.  
03042  
03041  
1
3
11  
Vi+  
i
Vo+  
1
11  
Vi+  
Vo1+  
PWM  
4
3
(Trim) R  
i
10  
13  
Vo1–  
10  
12  
PWM  
10 nF  
Vo—  
Vo2+  
2 × 2200 pF  
2
4
Vi—  
2
12  
14  
Vo2–  
Vi–  
13  
R
n.c.  
n.c.  
2 × 2200 pF  
Fig. 1  
Block diagram, single output types, standard pinout  
Fig. 2  
Block diagram, double output types, standard pinout  
03063  
03062  
1
3
Vi+  
Vo+  
Go  
1
3
Vi+  
Vo+  
PWM  
10  
PWM  
10 nF  
5
Vo–  
2 × 2200 pF  
2
Vi–  
2
5
Vi–  
Vo –  
2 × 2200 pF  
Fig. 3  
Fig. 4  
Block diagram, single output types, C pinout  
Block diagram, dual output types, C pinout  
Edition 4/04.2001  
4/18  
Board Mountable  
DC-DC Converters  
IMX 7 Series  
Electrical Input Data  
General conditions:  
TA = 25°C, unless TC is specified.  
Connector pins i and Viinterconnected.  
Trim or R input not connected.  
Table 2: Input Data  
Input  
20 IMX 7  
40 IMX 7  
70 IMX 7  
110 IMX 7  
Characteristics  
Conditions  
min typ max min typ max min typ max min typ max Unit  
Ui  
Input voltage range 1  
TC min...TC max  
Io = 0...Io nom  
8.4  
36 16.8 6  
75 40  
100  
121 60  
150 V DC  
Ui nom  
Ui sur  
Nominal input voltage  
20  
40  
70  
110  
Repetitive surge  
voltage  
abs. max input (3 s)  
150 V  
50 5  
4
4
4
tstart up  
Converter 2  
start-up time  
switch on  
Worst case condition at  
Ui min and full load  
0.25 0.5  
0.1  
0.25 0.5  
0.25 0.5  
0.25 0.5  
s
inh. release  
0.1  
0.1  
0.1  
trise  
Rise time 2  
Ui nom  
Io nom  
resistive load  
5
5
5
5
ms  
capacitive load  
12  
12  
12  
12  
Ii o  
No load input current  
Input capacitance  
Inhibit voltage  
Io = 0, Ui min...Ui max  
for surge calculation  
unit operating  
15 30  
4.7  
8
15  
8
15  
8
15  
mA  
µF  
Ci  
0.5  
0.2  
0.2  
Uinh  
10...0.8  
10 ...0.8  
10 ...0.8  
10 ...0.8  
V DC  
unit inhibited  
open or  
2.4...Ui max  
open or  
2.4...Ui max  
open or  
2.4...75  
open or  
2.4...75  
Iinh  
Inhibit current  
unit operating  
unit inhibited  
Ui min...Ui max  
0.5  
0.5  
0.5  
0.5  
mA  
1
1
1
1
Ii inh  
Input current  
<3.0  
<3.0  
<3.0  
<3.0  
if unit shut down  
7
Iinr p  
fs  
Inrush peak current  
Switching frequency  
Ui = Ui nom  
3.8  
3.7  
approx. 400  
30  
4.2  
approx. 400  
20  
5.6  
A
Ui min...Ui max, Io = 0...Io nom approx. 400  
approx. 300 kHz  
10 mApp  
Ii rr  
Reflected  
Io = 0...Io nom  
50  
ripple current  
ui RFI  
Input RFI level  
EN 55022 3  
B
B
B
B
conducted and radiated  
1 Ui min will not be as stated if Uo is increased above Uo nom by use of the R input. If the output voltage is set to a higher value,  
Ui min will be proportionally increased.  
2 Measured with a resistive and max. admissible capacitive load.  
3 Measured with a lead lenght of 0.1 m, leads twisted. Double output units with both outputs in parallel. 70/110 IMX 7 types need an  
external capacitor at the input. (e.g. 1µF film or ceramic)  
4 See 19 Pfl 1: Electromagnetic Immunity.  
5 The DC-DC converter shuts down automatically at approx. 38 V.  
6 Operation at lower input voltage possible: Po approx. 80% of Po nom at Ui min = 14.4 V.  
7 Source impedance according to ETS 300132-2, at Ui nom  
.
Uo  
trise  
04008  
Uo nom  
t
tstart up  
Fig. 5  
Converter start-up and rise time  
Edition 4/04.2001  
5/18  
Board Mountable  
DC-DC Converters  
IMX 7 Series  
Input Transient Voltage Protection  
In many applications transient voltages on the input of the  
converter are always possible. These may be caused for ex-  
ample by short circuits between Vi+ and Viwhere the net-  
work inductance may cause high energy pulses.  
To achieve IEC/EN 61000-4-5, level 2 compliance an addi-  
tional inductor and capacitor should be provided externally  
as shown in the figure below. The components should have  
similar characteristics as listed in table: Components for  
external circuitry to comply with IEC/EN 61000-4-5.  
In order to protect the converters the IMX 7 types have a  
built-in transient protection as per table below:  
Please note: The suppressor diode D is only necessary for  
20 IMX 7 types. To withstand 150 V transients according to  
19 Pfl 1, applicable for 40 IMX 7 types, the same external  
circuitry with similar components as for IEC/EN 61000-4-5,  
level 2 compliance can be used.  
Table 3: Built-in transient voltage suppressor  
Type  
Breakdown  
Voltage  
VBR nom  
Peak Power  
at 1 ms  
PP  
Peak Pulse  
Current  
IPP  
07064  
20 IMX 7 1  
40 IMX 7 2  
70 IMX 7 2  
110 IMX 7 2  
over voltage lockout at approx. 38 V  
Vi+  
L
100 V  
144 V  
167 V  
1500 W  
600 W  
600 W  
11 A  
2.9 A  
2.5 A  
+
i
C
D
Vi–  
1 The built-in overvoltage lockout circuit shuts down the converter  
at approx. 38 V protecting the input up to 50 V DC. For higher  
transient voltages an external suppressor or voltage limiting  
circuit as e.g. for IEC/EN 61000-4-5, level 2 compliance should  
be provided.  
Fig. 6  
Example for external circuitry to comply with  
IEC/EN 61000-4-5, level 2 (transzorb D not necessary for  
40/70/110 IMX 7 types).  
2 If transients generating currents above the peak pulse current  
are possible then an external limiting network such as the circuit  
recommended for IEC/EN 61000-4-5, level 2 compliance is  
necessary.  
Table 4: Components for external circuitry to comply with IEC/EN 61000-4-5  
Circuit Ref.  
20 IMX 7  
40 IMX 7  
70 IMX 7  
110 IMX 7  
L
330 µH, 0,115 , 1 A  
330 µH, 0,42 , 600 mA  
1000 µH, 2.9 , 290 mA  
330 µH, 0.65 , 430 mA  
TDK SF-T8-110S-01  
TDK TSL1110-331KR55  
Toko 822LY-102K  
Toko 822LY-331K  
C
D
68 µF, 63 V, 85°C  
68 µF, 100 V, 85°C  
47 µF, 150 V, 85°C  
200 µF, 200 V, 105°C  
Motorola 1.5KE39A  
n.a.  
n.a.  
n.a.  
04033  
17.5  
10  
04029  
04032  
10.5  
0.7  
5
7.5  
5
0.7  
Fig. 7  
Fig. 8  
Fig. 9  
Dimensions of inductor L.  
(TDK SF-T8-110S-01)  
Dimensions of inductor L.  
(TDK TSL1110-331KR55)  
Dimensions of inductor L.  
(Toko R622LY-102K)  
Reverse Polarity Protection at Input  
1 A/Div.  
4
04030  
The suppressor diode on the input also provides for reverse  
polarity protection by conducting current in the reverse di-  
rection, thus protecting the unit. An external fuse is required  
to limit this current:  
For 20 IMX 7 a fast 2 A (F2A) fuse is recommended.  
For 40 IMX 7 a fast 1 A (F1A) fuse is recommended.  
For 70 IMX 7 a fast 0.63 A (F.63A) fuse is recommended.  
For 110 IMX 7 a fast 0.63 A (F.63A) fuse is recommended.  
3
2
1
0
Inrush Current  
The inrush current has been kept as low as possible by  
choosing a very small input capacitance. A series resistor  
may be inserted in the input line to limit this current further.  
10 µs/Div.  
Fig. 10  
Typical inrush current at Ui nom, Po nom vs. time (40 IMX 7)  
measured according to prETS 300132-2 (Version 4.3)  
Edition 4/04.2001  
6/18  
Board Mountable  
DC-DC Converters  
IMX 7 Series  
Electrical Output Data  
General conditions:  
TA = 25°C, unless TC is specified.  
Connector pins i and Viinterconnected.  
Trim or R input not connected.  
Table 5a: Output data for single output units  
Output  
Uo nom  
3.3 V  
5.1 V  
min typ max  
Characteristics  
Conditions  
Ui nom  
min typ max  
Unit  
VDC  
A
Uo1  
Output voltage  
3.28  
3.32  
5.07  
5.13  
Io nom Output current  
Ui min...Ui max  
Ui nom, TC = 25°C  
1.5  
1.2  
2
Io L  
Current limit  
3.0  
2.4  
DUo U Line and load regulation Ui min...Ui max  
Io = (0.05...1) Io nom  
±1  
±1  
%
5
uo1, 2 Output voltage noise  
20/40/70 IMX  
110 IMX  
Ui min...Ui max  
Io = Io nom  
70  
70  
mVpp  
6
20 40  
40 50  
130  
20 40  
40 50  
130  
Uo clp Output overvoltage  
115  
115  
%
limitation 7  
Co ext Admissible capacitive load  
2500  
2000  
µF  
mV  
ms  
uo d Dynamic Voltage deviat. Ui nom  
±250  
±250  
1
load  
regulat  
I
o nom / Io nom  
2
td  
Recovery time  
1
1
aUo Temperature coefficient  
DUo/DTC (TC min...TC max  
Ui min...Ui max  
Io = 0...Io max  
)
±0.02  
±0.02  
%/K  
Table 5b: Output data for single output units  
Output  
Uo nom  
12 V  
15 V  
24 V  
min typ max  
Characteristics  
Conditions  
min typ max  
min typ max  
15.12 23.81  
Unit  
Uo1  
Output voltage  
Ui nom  
20 IMX Ui min...Ui max  
40/70/110 IMX  
11.90 12.10 14.88  
24.19 VDC  
A
Io nom Output  
current 1  
0.5  
0.6  
0.4  
0.26  
0.3  
0.48  
Io L  
Current  
limit 2, 3  
20 IMX Ui nom, TC = 25°C  
1.0  
1.2  
±1  
0.95  
1.1  
±1  
0.5  
0.6  
40/70/110 IMX  
DUo U Line regulation  
DUo l Load regulation 4  
Ui min...Ui max, Io nom  
±1  
±3  
%
Ui nom  
Io = (0.1...1) Io nom  
±3  
±3  
5
uo1, 2 Output voltage noise  
Ui min...Ui max  
Io = Io nom  
120  
150  
240  
mVpp  
6
25 50  
130  
30 60  
130  
50 100  
130  
Uo clp Output overvoltage limit. 7 Minimum load 1% 115  
115  
115  
%
Co ext Admissible  
capacitive load 3  
300  
200  
100  
µF  
uo d  
td  
Dynamic Voltage deviat. Ui nom  
±330  
±350  
±600  
mV  
ms  
1
load  
Io nom / Io nom  
2
Recovery time  
1
1
1
regulat.  
aUo  
Temperature coefficient  
DUo/DTC (TC min...TC max  
Ui min...Ui max  
Io = 0...Io max  
)
±0.02  
±0.02  
±0.02  
%/K  
1 Each output is capable of delivering full output power, Po nom according to table: Type Survey.  
2 The current limit is primary side controlled.  
3 Measured with both outputs connected in parallel.  
4 Conditions for specified output. Other output loaded with constant current Io = 0.5 Io nom  
5 BW = 20 MHz  
6 Measured with a probe according to EN 61204.  
7 The overvoltage protection is not tracking with the R control.  
.
Edition 4/04.2001  
7/18  
Board Mountable  
DC-DC Converters  
IMX 7 Series  
Table 5c: Output data for double output units  
Output  
Uo nom  
2 × 5 V  
2 × 12 V  
min typ max  
2 × 15 V  
2 × 24 V  
min typ max  
Characteristics  
Conditions  
min typ max  
min typ max  
Unit  
Uo1  
Uo2  
Output voltage  
Ui nom  
Io = 0.5 Io nom  
4.96  
4.95  
5.04 11.90  
5.05 11.88  
12.10 14.88  
12.12 14.85  
15.12 23.81  
15.15 23.75  
24.19 VDC  
24.25  
Io nom Output  
current 1  
20 IMX Ui min...Ui max  
40/70/110 IMX  
2 × 0.6 2 × 0.25  
2 × 0.7 2 × 0.3  
2 × 0.2  
2 × 0.24  
0.95  
2 × 0.13  
2 × 0.15  
0.5  
A
Io L  
Current  
20 IMX Ui nom, TC = 25°C  
2.4  
2.8  
±1  
1.0  
1.2  
±1  
±3  
limit 2, 3  
40/70/110 IMX  
1.1  
±1  
±3  
0.6  
±1  
±3  
DUo U Line regulation  
DUo l Load regulation 4  
Ui min...Ui max, Io nom  
%
Ui nom  
±3  
Io = (0.1...1) Io nom  
5
uo1, 2 Output voltage noise  
Ui min...Ui max  
Io = Io nom  
80  
120  
150  
30 60  
130  
240 mVpp  
50 100  
130  
100  
6
20 40  
130  
25 50  
130  
Uo clp Output overvoltage limit. 7 Minimum load 1% 115  
115  
115  
115  
%
Co ext Admissible  
capacitive load 3  
2000  
300  
200  
µF  
uo d  
td  
Dynamic Voltage deviat. Ui nom  
±150  
±330  
±350  
±600  
mV  
ms  
1
load  
Io nom / Io nom  
2
Recovery time  
1
1
1
1
regulat.  
aUo  
Temperature coefficient  
DUo/DTC (TC min...TC max  
Ui min...Ui max  
Io = 0...Io max  
)
±0.02  
±0.02  
±0.02  
±0.02  
%/K  
1 Each output is capable of delivering full output power, Po nom according to table: Type Survey.  
2 The current limit is primary side controlled.  
3 Measured with both outputs connected in parallel.  
4 Conditions for specified output. Other output loaded with constant current Io = 0.5 Io nom  
5 BW = 20 MHz  
6 Measured with a probe according to EN 61204.  
7 The overvoltage protection is not tracking with the R control.  
.
Edition 4/04.2001  
8/18  
Board Mountable  
DC-DC Converters  
IMX 7 Series  
Short Circuit Behaviour  
Connection in Series or in Parallel  
The current limit characteristic shuts down the converter  
whenever a short circuit is applied to its output. It acts self-  
protecting and automatically recovers after removal of the  
overload condition (hiccup mode).  
Connection in series:  
The outputs of single or double output units can be con-  
nected in series without any precautions, taking into consid-  
eration that the highest output voltage should remain below  
60 V for SELV operation.  
Thermal Considerations  
Connection in parallel:  
If a converter, mounted on a pcb, is located in free, quasi-  
stationary air (convection cooling) at the indicated maxi-  
mum ambient temperature TA max (see table: Temperature  
specifications) and is operated at its nominal input voltage  
and output power, the case temperature TC measured at the  
Measuring point of case temperature TC (see: Mechanical  
Data) will approach the indicated value TC max after the  
warm-up phase. However, the relationship between TA and  
TC depends heavily on the conditions of operation and inte-  
gration into a system. The thermal conditions are influenced  
by input voltage, output current, airflow, temperature of sur-  
rounding components and surfaces and the properties of  
the printed circuit board. TA max is therefore only an indica-  
tive value and under practical operating conditions, the am-  
bient temperature TA may be higher or lower than this value.  
Double outputs of the same converter with equal output  
voltage (e.g. 5V / 5V) can be put in parallel and will share  
their output currents almost equally. Parallel operation of  
single or double outputs of two or more converters with the  
same output voltage may cause start-up problems at initial  
start-up. This is only advisable in applications where one  
converter is able to deliver the full load current as e.g. re-  
quired in true redundant systems.  
Output Overvoltage Protection  
The outputs of single output units and -05-05- types are  
protected against overvoltages by a second control loop. In  
the event of an overvoltage on the output the unit will shut-  
down and attempt to restart approximately every 0.4 sec-  
onds. Double output units (with exception of the -05-05-  
types) are protected against overvoltages by a Zener diode  
across the second output. Under worst case conditions the  
Zener diode will short circuit. Since with double output units  
both outputs track each other the protection diode is only  
provided in one of the outputs. The main purpose of this fea-  
ture is to protect against possible overvoltages which could  
occur due to a failure in the feedback control circuit. The  
output overvoltage protection is not designed to withstand  
externally applied overvoltages.  
Caution: The case temperature TC measured at the  
Measuring point of case temperature TC (see: Mechani-  
cal Data) may under no circumstances exceed the speci-  
fied maximum value. The installer must ensure that un-  
der all operating conditions TC remains within the limits  
stated in the table: Temperature specifications.  
Typical Performance Curves  
Uo [V]  
Uo [V]  
05087  
05086  
13  
5.5  
12  
11  
10  
9
5.0  
4.5  
4.0  
3.5  
3.0  
8
7
Io total [A]  
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9  
0
0
0.2  
0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 Io [A]  
0.4  
Fig. 11  
Fig. 12  
Uo versus Io (typ) of single output units with Uo = 5.1 V.  
Uo versus Io (typ) of double output units, with both outputs  
in parallel.  
Uo1 [V]  
Uo1, Uo2 [V]  
05088  
13.5  
05039  
14  
13  
13.0  
12.5  
Io2 = 0.03 A  
Io2 = 0.3 A  
12  
11  
10  
Uo4  
Uo1  
12.0  
11.5  
11.0  
Io1  
Io1 nom  
[%]  
50  
75  
100  
125  
150  
0
25  
0.03  
0.10  
0.15  
0.25  
0.35 Io1 [A]  
0.05  
0.20  
Fig. 13  
Fig. 14  
Uo1 versus Io1 (typ) for various Io2 (2 × 12 V).  
Flexible load distribution on double outputs (2 × 12 V) with  
The cross load effect is negligible.  
load variation from 0...150% of Po1 nom on output 1. Output  
2 loaded with 25% of Po2 nom  
.
Edition 4/04.2001  
9/18  
Board Mountable  
DC-DC Converters  
IMX 7 Series  
h [%]  
05041  
05052  
Uo [%]  
90  
overload short circuit condition  
switch-off  
Ui nom  
Ui max  
Ui min  
100  
70  
80  
70  
60  
8
50  
t [ms]  
60  
60  
Po  
Po nom  
40  
25  
[%]  
50  
100  
75  
Fig. 15  
Fig. 16  
Overload switch-off (hiccup mode). Typical values.  
Frequency of pulses: 16.5 Hz, puls duration: 8.5 ms.  
Efficiency versus input voltage and load. Typical values  
(40 IMX 7-12-12).  
Auxiliary Functions  
Inhibit Function  
Adjustable Output Voltage (R input)  
The output(s) of the converter may be enabled or disabled  
by means of a logic signal (TTL, CMOS, etc.) applied to the  
inhibit pin. No output voltage overshoot will occur when the  
unit is turned on. If the inhibit function is not required the  
inhibit pin should be connected to Vito enable the output  
(active low logic, fail safe).  
As a standard feature, the IMX 7 single and double output  
units offer adjustable output voltage(s) by using the control  
input R. If the R pin is left open circuit the output voltage is  
set to Uo nom. The output voltage is adjustable in the range  
75...105% of Uo nom.The circuit works for single and double  
output units in a different way. For output voltages Uo >  
Uo nom, the minimum input voltage Ui min (see: Electrical In-  
Converter operating:  
Converter inhibited  
10 V...0.8 V  
put Data) increases proportionally to Uo/Uo nom  
.
or inhibit pin left open: 2.4 V...Ui max  
(<75 V for 70/110 IMX 7)  
Single output units:  
The R input is referenced to the secondary side of the con-  
verter. Adjustment of the output voltage is possible by  
means of either an external resistor or a voltage source.  
06070  
Vi+  
a) Adjustment by means of an external resistor Rext1  
:
Depending upon the value of the required output voltage,  
the resistor shall be connected  
i
either: Between the R pin and Voto achieve an output  
voltage adjustment range of approximately  
Vi–  
Uo = 75...100% Uo nom. (85...100% for 3.3 V outputs)  
Fig. 17  
Uo  
If the inhibit is not used the inhibit pin should be con-  
nected to Vi–  
R
ext1 4 k• –––––––––  
Uo nom Uo  
or: Between the R pin and Vo+ to achieve an output volt-  
age range of approximately Uo = 100...105% Uo nom  
.
(Uo 2.5 V)  
2.5 V (Uo/Uo nom 1)  
R
ext2 4 k• –––––––––––––––––––  
Edition 4/04.2001  
10/18  
Board Mountable  
DC-DC Converters  
IMX 7 Series  
a) Adjustment by means of an external resistor.  
b) Adjustment by means of an external voltage Uext be-  
tween Voand R pins.  
Programming of the output voltage by means of an exter-  
nal resistor Rext1 is possible within a limited range of  
100...105% of Uo nom. Rext1 should be connected between  
the R-pin and Vi. Connection of Rext1 to Vi+ may dam-  
age the converter. The following table indicates suitable  
resistor values for typical output voltages under nominal  
conditions (Ui nom, Io = 0.5 Io nom), with either paralleled  
outputs or equal load conditions on each output.  
The control voltage range is 1.87...2.62 V and allows for  
an adjustment in the range of approximately 75...105%.  
(85...105% for 3.3 V outputs)  
Uo 2.5 V  
Uo nom  
U
ext –––––––––  
Attempting to adjust the output below this range will  
cause the converter to shutdown (hiccup mode).  
Table 6: Rext1 for Uo > Uo nom  
approximate values (Ui nom, Io1, 2 = 0.5 Io1/2 nom  
;
Note: Applying an external control voltage >2.75 V may  
damage the converter.  
)
Uo [% Uo nom  
]
Rext [k]  
06029  
105...108 (107 typically)  
0
L
Vo+  
R
105  
104  
103  
102  
101  
100  
1.5  
5.6  
12  
27  
68  
Rext2  
Uref 2.5 V  
4 kΩ  
+
control  
circuit  
Uext  
Rext1  
Vo—  
N
b) Adjustment by means of an external voltage source Uext  
.
For external output voltage programming in the range  
75...105% of Uo nom a (0...20 V) source Uext is required,  
connected to the R-pin and Vi. The table below indi-  
cates typical Uo versus Uext values under nominal condi-  
tions (Ui nom, Io = 0.5 Io nom), with either paralleled outputs  
or equal load conditions on each output. Applying a con-  
trol voltage greater than 20 V will set the converter into a  
hiccup mode. Direct paralleling of the R-pins of units con-  
nected in parallel is feasible.  
Fig. 18  
Output voltage control for single output units by means of  
the R-input  
Double output units:  
The R input (Trim) input is referenced to the primary side.  
The figure below shows the circuit topology. Adjustment of  
the output voltage is possible by means of either an exter-  
nal resistor in the range of 100...105% of Uo nom, or an ex-  
Table 7: Uext for Uo = 75...105% Uo nom  
;
typical values (Ui nom, Io1, 2 = 0.5 Io1/2 nom  
)
ternal voltage source in the range of 75...105% of Uo nom  
.
Uo [% Uo nom  
]
Uext [V]  
06030  
Vi+  
Vo1+  
105  
102  
95  
85  
75  
0
1.6  
4.5  
9
Vo1–  
R (Trim)  
+
Vo2+  
Control  
circuit  
13  
Uext  
Rext  
Uref 2.5 V  
Vo2–  
Vi–  
Fig. 19  
Output voltage control for double output units by means of  
the R input  
Edition 4/04.2001  
11/18  
Board Mountable  
DC-DC Converters  
IMX 7 Series  
Electromagnetic Compatibility (EMC)  
which typically occur in many installations, but especially in  
battery driven mobile applications.  
A suppressor diode together with an input filter form an ef-  
fective protection against high input transient voltages  
Electromagnetic Immunity  
Table 8: Immunity type tests  
Phenomenon  
Standard 1  
Class  
Level  
Coupling  
mode 2  
Value  
applied  
Waveform  
Source  
Imped.  
Test  
procedure  
In  
oper. form.  
Per- 3  
Electrostatic  
discharge  
to case  
IEC/EN  
61000-4-2  
2
3
3
contact discharge 4000 Vp  
R pin open  
i pin connec. to Vi–  
1/50 ns  
330 Ω  
10 positive and  
10 negative  
discharges  
yes  
B
air discharge  
R pin open  
i pin connec. to Vi–  
8000 Vp  
10 V/m  
Electromagnetic IEC/EN  
field  
antenna  
AM 80%  
1 kHz  
261000 MHz  
yes  
yes  
A
B
61000-4-3  
ENV 50204  
PM, 50% duty  
cycle, 200 Hz  
resp. frequ.  
900 MHz  
Electrical fast  
transient/burst  
IEC/EN  
61000-4-4  
4
direct +i/i  
4000 Vp bursts of 5/50 ns 50 Ω  
5 kHz rep. rate  
1 min positive  
1 min negative  
transients per  
coupling mode  
transients with  
15 ms burst  
duration and a  
300 ms period  
Surge  
IEC/EN  
3
3
+i/i  
2000 Vp  
10 Vrms  
1.2/50 µs  
2 Ω  
5 pos. and 5 neg.  
impulses per  
coupling mode  
yes  
B
61000-4-5 5  
Conducted  
disturbancies  
IEC/EN  
61000-4-6  
+i/i  
+i/i  
AM modulated  
50 Ω  
0.15...80 MHz  
yes  
yes  
A
B
(140 dBµV) 80%, 1 kHz  
150 Ω  
Transient  
19 Pfl 1 4  
150 Vp 0.1/0.3 ms  
limited to  
<100 A  
3 positive  
1 Related and previous standards are referenced in: Technical Information: Standards.  
3 A = normal operation, no deviation from specification, B = temporary deviation from specs. possibe.  
4 For 40 IMX 7 types (additional external components required). Not applicable for 20 IMX 7 types.  
2 i = input, o = output.  
5 External components required.  
Electromagnetic Emission  
Conducted RFI noise at input according to EN 55022  
Radiated RFI noise according to EN 55022.  
[dBµV/m]  
[dBµV]  
90  
07024  
07023  
40  
80  
35  
30  
25  
20  
EN 55022 A  
EN 55022 B  
70  
60  
EN 55022 B  
50  
40  
30  
20  
10  
0
15  
10  
0
[MHz]  
MHz  
Fig. 21  
Typical radio frequency-interference voltage at Ui nom  
Io nom, measured with an antenna (distance 10 m). Output  
leads 0.1 m, twisted (70 IMX-7-15-15).  
,
Fig. 20  
Typical disturbance voltage (quasi-peak) at the input ac-  
cording to CISPR 11/EN 55011 and CISPR 22/EN 55022  
measured at Ui nom and Io nom. Output leads 0.1 m, twisted.  
(40 IMX 7-15-15). External capacitor (1 µF ceramic or  
film) required at the input for 70 IMX 7, 110 IMX 7 types.  
Edition 4/04.2001  
12/18  
Board Mountable  
DC-DC Converters  
IMX 7 Series  
Immunity to Environmental Conditions  
Table 9: Environmental testing  
Test Method  
Standard  
Test Conditions  
Status  
Ca  
Ea  
Eb  
Fc  
Damp heat  
steady state  
IEC/DIN IEC 60068-2-3  
MIL-STD-810D section 507.2 Relative humidity:  
Duration:  
Temperature:  
40 ±2 °C  
%
56 days  
Unit not  
operating  
93 +2/-3  
Shock  
(half-sinusoidal)  
IEC/EN/DIN EN 60068-2-27  
MIL-STD-810D section 516.3 Bump duration:  
Number of bumps:  
Acceleration amplitude:  
100 gn = 981 m/s2  
6 ms  
18 (3 each direction)  
Unit  
operating  
Bump  
(half-sinusoidal)  
IEC/EN/DIN EN 60068-2-29  
MIL-STD-810D section 516.3 Bump duration:  
Number of bumps:  
Acceleration amplitude:  
40 gn = 392 m/s2  
6 ms  
6000 (1000 each direction)  
Unit  
operating  
Vibration  
(sinusoidal)  
IEC/EN/DIN EN 60068-2-6  
Acceleration amplitude:  
0.35 mm (10...60 Hz)  
5 gn = 49 m/s2 (60...2000 Hz) operating  
10...2000 Hz  
Unit  
Frequency (1 Oct/min):  
Test duration:  
7.5 h (2.5 h each axis)  
Fh  
Kb  
Vibration,  
broad-band  
random  
IEC/EN 60068-2-64  
MIL-STD-810D section 514.3 Frequency band:  
Acceleration magnitude:  
Acceleration spectral density: 0.05 gn2/Hz  
Unit  
operating  
20...500 Hz  
4.9 gn rms  
(digital control)  
Test duration:  
3 h (1 h each axis)  
Salt mist, cyclic  
(sodium chloride  
NaCl solution)  
IEC/EN/DIN IEC 60068-2-52  
Concentration:  
Duration:  
Storage:  
Storage duration:  
Number of cycles:  
5% (30°C)  
Unit not  
operating  
2 h per cycle  
40°C, 93% rel. humidity  
22 h per cycle  
3
Table 10: Temperature specifications, valid for air pressure of 800...1200 hPa (800...1200 mbar)  
Temperature  
Standard -9  
Option -8  
Characteristics  
Conditions  
Operational 2  
min  
max  
71  
min  
max  
85  
Unit  
TA  
TC  
TS  
Ambient temperature 1  
40  
40  
40  
40  
40  
55  
°C  
Case temperature  
Storage temperature 1  
95  
105  
105  
Non operational  
100  
1 MIL-STD-810D section 501.2 and 502.2  
2 See: Thermal Considerations  
Table 11: MTBF and device hours  
MTBF  
Ground Benign  
Ground Fixed  
Ground Mobile  
TC = 50°C  
84'800 h  
MTBF acc. to MIL-HDBK-217F  
40 IMX 7-05-7  
TC = 40°C  
1'671'700 h  
1'640'000 h  
TC = 40°C  
TC = 70°C  
83'800 h  
83'000 h  
248'000 h  
214'000 h  
40 IMX 7-15-15-7  
77'000 h  
Edition 4/04.2001  
13/18  
Board Mountable  
DC-DC Converters  
IMX 7 Series  
Mechanical Data  
Dimensions in mm. Tolerances ±0.3 mm unless otherwise indicated.  
European  
Projection  
S09030  
50.8 (2")  
0.8 × 1.2 (0.03 x 0.05") Pins  
1.6 (0.06) PCB holes  
3.4 (0.13")  
3.81(0.15")  
14  
1
4
10  
4.6 (0.18")  
PT 2.2  
self tapping screws  
3.81(0.15")  
45.7 (1.8")  
Measuring point  
of case temperature TC  
0.8 (0.3")  
Fig. 22  
Case IMX 7 with standard soldering pins  
Weight: <20 g  
09032  
50.8 (2")  
35.5 (1.4")  
1 (0.04") Pins  
1.2 (0.05") PCB holes  
0.5(0.02")  
15.2 (0.6")  
3
1
2
4
5
Measuring point of  
case temperature TC  
Fig. 23  
Case IMX 7 with C pinout (option C) for double output units, pins 6 and 7 are not fitted.  
With single output units pins 4, 6 and 7 are not fitted.  
Weight: <24 g  
S90002  
0.8 × 1.2 (0.03 x 0.05") Pins  
1.6 (0.06) PCB holes  
48 (1.9")  
1
14  
10  
4
43.2 (1.7")  
3.5 (0.14")  
0.8 (0.3")  
Fig. 24  
Open frame (option Z)  
Weight: <20 g  
Edition 4/04.2001  
14/18  
Board Mountable  
DC-DC Converters  
IMX 7 Series  
50.8 (2")  
0.8 × 1.2 (0.03 x 0.05") Pins  
14  
1
10  
4
42.4 (1.67")  
S09031  
Measuring point of  
case temperature TC  
4.2 (0.17")  
Fig. 25  
Surface mount version with pins (option M)  
Weight: <20 g  
50.8 (2")  
Proposed solder lands  
18  
1
3.6 (1.4")  
Foot print  
8 x 5 (1.9")  
90001  
Measuring point of  
case temperature TC  
Fig. 26  
Surface mount version with PCB lid (option L)  
Weight: <20 g  
Safety and Installation Instructions  
Cleaning Agents  
Installation Instruction  
In order to avoid possible damage, any penetration of  
cleaning fluids has to be prevented, since the power sup-  
plies are not hermetically sealed.  
Installation of the DC-DC converters must strictly follow the  
national safety regulations in compliance with the enclo-  
sure, mounting, creepage, clearance, casualty, markings  
and segregation requirements of the end-use application.  
Standards and approvals  
Connection to the system shall be made via a printed circuit  
board according to: Mechanical Data.  
All DC-DC converters are pending to be UL recognized  
according to UL 1950, UL recognized for Canada to CAN/  
CSA C22.2 No. 950-95 and LGA approved to IEC/EN  
60950 standards.  
The units should be connected to a secondary circuit.  
Check for hazardous voltages before altering any connec-  
tions.  
The units have been evaluated for:  
Building in  
Do not open the module.  
Supplementary insulation input to output, based on their  
maximum input voltage  
Ensure that a unit failure (e.g. by an internal short-circuit)  
does not result in a hazardous condition. See also: Safety  
of operator accessible output circuit.  
The use in a pollution degree 2 environment  
Connecting the input to a secondary circuit which is sub-  
ject to a maximum transient rating of 1500 V for 20/40  
IMX 7, 2000 V for 70 IMX 7 and 2500 V for 110 IMX 7  
types.  
Input Fuse  
To prevent excessive current flowing through the input sup-  
ply line in case of a short-circuit across the converter input  
an external fuse should be installed in a non earthed input  
supply line. We recommend a fast acting fuse F2A for  
20 IMX 7 and F1A for 40 IMX 7 and F0.63A for 70/110 IMX  
7 types.  
The DC-DC converters are subject to manufacturing sur-  
veillance in accordance with the above mentioned UL,  
CSA, EN and ISO 9001 standards.  
Protection Degree  
The protection degree of the DC-DC converters is IP 30.  
Edition 4/04.2001  
15/18  
Board Mountable  
DC-DC Converters  
IMX 7 Series  
Isolation  
Table 15: Pin allocation SMD version (option L)  
The electric strength test is performed as factory test in ac-  
cordance with IEC/EN 60950 and UL 1950 and should not  
be repeated in the field. Power-One will not honour any  
guarantee claims resulting from electric strength field tests.  
Pin  
1
Single output  
Vo  
Dual output  
Vo1  
Go  
2
Go  
3
n.c.  
Vo2  
n.c.  
Table 12: Electric strength test voltages  
4
n.c.  
Characteristic  
I/O  
O/O  
Unit  
5
n.c.  
n.c.  
20/40 IMX 70 IMX 110 IMX  
6
n.c.  
n.c.  
Electric strength  
test voltage 1 s  
1.2  
1.5  
1.5  
2.0  
2.0  
2.5  
0.1  
kVrms  
7
n.c.  
n.c.  
0.15 kV DC  
8
n.c.  
n.c.  
Coupling  
capacitance  
1.2  
1.2  
1.2  
-
-
-
nF  
MΩ  
kV  
9
n.c.  
Trim  
n.c.  
Insulation resist.  
at 500 V DC  
>100  
>100  
>100  
10  
11  
12  
13  
14  
15  
16  
17  
18  
n.c.  
i
i
Partial discharge  
extinction voltage  
Consult factory  
no pin  
no pin  
n.c.  
no pin  
no pin  
n.c.  
Table 13: Pin allocation, standard pinout, option M and Z  
n.c.  
n.c.  
Pin  
1
Single output  
Double output  
n.c.  
n.c.  
Vi+  
Vi–  
i
Vi+  
Vi–  
Vi–  
Vi–  
2
Vi+  
Vi+  
3
i
4
n.c.  
Vo–  
Vo+  
Vo–  
R
R (Trim)  
Vo1–  
Vo1+  
Vo2–  
Vo2+  
n.c.  
10  
11  
12  
13  
14  
n.c.  
10011  
14  
1
13  
12  
11  
10  
2
3
4
Bottom view  
Fig. 27  
Pin allocation standard pinout  
Table 14: Pin allocation for C-pinout (option C)  
Pin  
1
Single output  
Dual output  
Vi+  
Vi–  
Vi+  
Vi–  
2
3
Vo+  
Vo+  
Go  
4
no pin  
Vo–  
5
Vo–  
10012  
3
4
5
1
2
Fig. 28  
Pin allocation C pinout, bottom view  
Edition 4/04.2001  
16/18  
Board Mountable  
DC-DC Converters  
IMX 7 Series  
Safety of operator accessible output circuit  
If the output circuit of a DC-DC converter is operator acces-  
sible, it shall be an SELV circuit according to IEC/EN 60950  
related safety standards.  
cuit according to IEC/EN 60950 up to a configured output  
voltage (sum of nominal voltages if in series or +/configu-  
ration) of 46 V.  
The insulation concept table below shows some possible  
installation configurations, compliance with which causes  
the output circuit of the DC-DC converter to be an SELV cir-  
However, it is the sole responsibility of the installer to en-  
sure the compliance with the relevant and applicable safety  
regulations. More information is given in: Technical Infor-  
mation: Safety.  
Table 16: Insulation concept leading to an SELV output circuit  
Conditions Front end  
DC-DC converter  
Result  
Supply  
voltage  
Minimum required grade  
of isolation, to be provided DC output status of the front end  
by the AC-DC front end,  
including mains supplied from the  
Maximum Minimum required safety  
Measures to achieve the  
specified safety status of the  
output circuit  
Safety status of  
the DC-DC  
converter output  
circuit  
voltage  
output circuit  
battery charger  
front end 1  
Mains  
250 V AC  
Basic  
60 V  
Earthed SELV circuit 2  
ELV circuit  
Operational insulation (pro-  
vided by the DC-DC converter)  
SELV circuit  
Input fuse 3 output suppressor Earthed SELV  
diode(s) 4, and earthed  
output circuit(s) 2  
circuit  
>60 V  
60 V  
>60 V  
Hazardous voltage  
secondary circuit  
Double or reinforced  
SELV circuit  
Operational insulation (pro-  
vided by the DC-DC converter)  
SELV circuit  
TNV-2 circuit  
Supplementary insulation,  
based on the maximum input  
voltage (provided by the  
DC-DC converter)  
Double or reinforced insu-  
lated unearthed hazardous  
voltage secondary circuit 5  
1 The front end output voltage should match the specified input voltage range of the DC-DC converter.  
2 The earth connection has to be provided by the installer according to the relevant safety standard, e.g. IEC/EN 60950.  
3 The installer shall provide an approved fuse (type with the lowest rating suitable for the application) in a non-earthed input line directly  
at the input of the DC-DC converter (see fig.: Schematic safety concept). For ULs purpose, the fuse needs to be UL-listed. See also:  
Input Fuse.  
4 Each suppressor diode should be dimensioned in such a way, that in the case of an insulation fault the diode is able to limit the output  
voltage to SELV (<60 V) until the input fuse blows (see fig.: Schematic safety concept).  
5 Has to be insulated from earth by basic insulation according to the relevant safety standard, based on the maximum output voltage  
from the front end.  
10004  
Fuse  
+
~
Mains  
Suppressor  
diode  
AC-DC  
front  
DC-DC  
con-  
Battery  
SELV  
Fig. 29  
end  
verter  
~
Schematic safety concept. Use fuse, suppressor diode  
and earth connection as per table: Safety concept leading  
to an SELV output circuit.  
Earth  
connection  
Earth  
connection  
Edition 4/04.2001  
17/18  
Board Mountable  
DC-DC Converters  
IMX 7 Series  
Description of Options  
Table 17: Survey of options  
Option  
Function  
Characteristics  
-8  
L
Operational temperature range TA = 40...85°C  
Surface mount version, SMD  
Surface mount version, SMD  
C-pinout  
Extended temperature range.  
Excludes option C, L.  
M
C
Excludes option C, M.  
Excludes option M, L as well as galvanic isolation between output 1  
and 2 of dual output units. Not available for 70/110 IMX 7 types.  
Option -8  
Option C  
Extension of the temperature range from standard  
25...71°C to 40...85°C. The modules will provide full out-  
put power with free air convection cooling. UL recognition  
up to 80°C. This option excludes option D.  
The C-pinout configures the electrically isolated double out-  
puts to the "industrial pinout" Vo1+, Vo2with common  
ground Go. With the C-pinout the converter height is in-  
creased by the adapter PCB (see also: Mechanical Data).  
Option M and L  
Surface mount version.  
Note: Precautions should be taken when reflow soldering  
the SMD version. The reflow soldering instructions below  
should be strictly adhered to. An inadequate soldering pro-  
cess may permanently damage the converter or degrade  
its performance and Power-One will not honour any gua-  
rantee/warranty claims resulting from damage caused by  
ignoring the soldering instructions.  
The surface mountable version of this product is assem-  
bled with high melting point solder (227°C) to ensure that  
the solder joints of of the internal components do not de-  
grade in the end users SMD soldering process.  
This product is only specified for "Forced Convection  
Reflow Soldering" (Hot Air). Any conventional soldering  
profile is acceptable provided that the restriction curve be-  
low is not exceeded at any time during the reflow process.  
Infrared soldering is not permitted.  
Tpeak [°C]  
Proposed solder lands  
11051  
240  
3.6 (1.4")  
Foot print  
235  
230  
225  
220  
215  
210  
8 x 5 (1.9")  
Fig. 32  
Proposed solder lands option L  
t [s]  
205  
50  
0
20  
30  
40  
10  
Fig. 30  
Forced convection reflow soldering restriction curve  
measured on pin 2  
Edition 4/04.2001  
18/18  
09119  
4

相关型号:

110IMX7-05-05-7M

DC-DC Regulated Power Supply Module, 2 Output, 7W, Hybrid, 2 INCH X 1 INCH, 10.50 MM HEIGHT, PACKAGE-9
BEL

110IMX7-05-05-8

IMX7/IMS7 DC-DC Series Data Sheet 7-Watt DC-DC Converters
POWER-ONE

110IMX7-05-05-8

7-Watt DC-DC Converters
BEL

110IMX7-05-05-8G

DC-DC Regulated Power Supply Module, 2 Output, 7W, Hybrid, ROHS COMPLIANT PACKAGE-9
BEL

110IMX7-05-05-8M

DC-DC Regulated Power Supply Module, 2 Output, 7W, Hybrid
BEL

110IMX7-05-05-8ZG

DC-DC Regulated Power Supply Module, 2 Output, 7W, Hybrid, ROHS COMPLIANT PACKAGE-14
BEL

110IMX7-05-05-9

7 Watt DC-DC Converters
POWER-ONE

110IMX7-05-05-9L

DC-DC Regulated Power Supply Module, 2 Output, 7W, Hybrid, 2 X 1 INCH, 10.50 MM HEIGHT, SMT-18
BEL

110IMX7-05-05-9Z

暂无描述
BEL

110IMX7-05-7

DC-DC Regulated Power Supply Module, 1 Output, 6.1W, Hybrid, 2 INCH X 1 INCH, 10.50 MM HEIGHT, PACKAGE-9
BEL

110IMX7-05-7D

DC-DC Regulated Power Supply Module, 1 Output, 6.1W, Hybrid, 2 INCH X 1 INCH, 10.50 MM HEIGHT, PACKAGE-9
BEL

110IMX7-05-7DM

DC-DC Regulated Power Supply Module, 1 Output, 6.1W, Hybrid, 2 INCH X 1 INCH, 10.50 MM HEIGHT, PACKAGE-9
BEL