12IML10-15-15-0M [BEL]
DC-DC Regulated Power Supply Module, 2 Output, 10W, Hybrid;型号: | 12IML10-15-15-0M |
厂家: | BEL FUSE INC. |
描述: | DC-DC Regulated Power Supply Module, 2 Output, 10W, Hybrid |
文件: | 总7页 (文件大小:208K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Board Mountable
DC-DC Converters
IML 10 Series
10 Watt DC-DC Converters
IML 10 Series
Wide input voltage ranges up to 75 V DC
1 or 2 outputs up to 30 V DC
1500 V DC I/O electric strength test voltage
• Wide input voltage ranges
• Electrical isolation, single and double output units
• Immunity to IEC/EN 61000-4-2, -3, -4, -5 and -6
• High efficiency (typ. 84%)
10.5
0.42"
• Flex power: flexible load distribution
• No load and short-circuit proof
25.4
1.0"
50.8
2.0"
• High reliability and no derating
• Operating ambient temperature range –25...60°C
• 2" × 1" case with 10.5 mm profile
• Supplementary insulation
Safety according to IEC/EN 60950, UL 1950
LGA
Summary
The IML10 series of board mountable 10 Watt DC-DC con-
verters has been designed according to the latest industry
requirements and standards. The converters are particu-
larly suitable for use in controlled environments, in battery
supported applications in industry or telecommunications
where high power densitiy and outstanding reliability are
required.
60 V DC. They are designed and built according to the inter-
national safety standards IEC/EN 60950, UL 1950, CAN/
CSA C22.2 No.950-95 and are LGA and UL marked. Ap-
provals pending.
A special feature is their small case size, 2" × 1" with
10.5 mm profile. The circuit comprises of integrated planar
magnetics and all components are automatically assem-
bled and solidly soldered onto a single PCB without any
wire connections. Magnetic feedback ensures maximum
reliability and repeatability in the control loop over all oper-
ating conditions. High efficiency, low heat dissipation and
careful considerations of possible thermal stresses ensure
the absence of hot spots providing high reliability. The ther-
mal design allows operation at full load up to an ambient
temperature of 60°C in free air without using any potting
material. Optionally the IML 10 series is available with the
industrial C pinout or with an SMD pinout, as well as with an
extended ambient temperature range –40...60°C.
Providing 3 input voltage ranges, 8.4...16.8, 18...36 and
36...75 V DC, the units are available with single and electri-
cally isolated double outputs allowing the configuration of
output voltages from 5 up to 30 V DC, with flexible load dis-
tribution on double output units. Features include efficient
input and output filtering with transient and surge protec-
tion, low output ripple and noise, consistently high effi-
ciency over the entire input voltage range, high reliability as
well as excellent dynamic response to load and line
changes.
The converters provide supplementary insulation with
SELV outputs as e.g. required in battery supported systems
where the bus voltage may exceed the SELV limit of
Table of Contents
Page
Page
Summary .......................................................................... 1
Type Survey and Key Data .............................................. 2
Type Key .......................................................................... 2
Mechanical Data .............................................................. 3
Safety and Installation Instructions .................................. 4
Description of Options...................................................... 7
Accessories ...................................................................... 7
Edition 6/4.2000
1/7
Board Mountable
DC-DC Converters
IML 10 Series
Type Survey and Key Data
Table 1: Type survey
Output 1
Output 2
Output
power
Po nom [W]
Input voltage Efficiency
Type
designation
Options
1
1
Uo nom
Io nom
[A]
Uo nom
Io nom
[A]
Ui min...Ui max
[V DC]
htyp
[%]
[V DC]
[V DC]
3.3
3.3
3.3
1.9
2
2
-
-
-
-
-
-
6.27
6.6
6.6
8.4...16.8
18...36
36...75
79
81
82
12 IML 10-03-3
24 IML 10-03-3
48 IML 10-03-3
-0, C, M, L, Z
-0, C, M, L, Z
-0, C, M, L, Z
5
5
5
1.6
1.9
1.9
-
-
-
-
-
-
8
9.5
9.5
8.4...16.8
18...36
36...75
79
81
82
12 IML 10-05-3
24 IML 10-05-3
48 IML 10-05-3
-0, C, M, L, Z
-0, C, M, L, Z
-0, C, M, L, Z
12
12
12
0.7
0.9
0.9
-
-
-
-
-
-
8.4
10.8
10.8
8.4...16.8
18...36
36...75
82
84
84
12 IML 10-12-3C2
24 IML 10-12-3C2
48 IML 10-12-3C2
-0, Z
-0, Z
-0, Z
15
15
15
0.6
0.7
0.7
-
-
-
-
-
-
9
10.5
10.5
8.4...16.8
18...36
36...75
83
84
84
12 IML 10-15-3C2
24 IML 10-15-3C2
48 IML 10-15-3C2
-0, Z
-0, Z
-0, Z
5.1
1
3.3
1
8.8
36...75
80
48 IML 10-0503-3
-0, C, M, L, Z
12
12
12
0.35
0.45
0.45
12
12
12
0.35
0.45
0.45
8.4
10.8
10.8
8.4...16.8
18...36
36...75
82
84
84
12 IML 10-12-12-3
24 IML 10-12-12-3
48 IML 10-12-12-3
-0, C, M, L, Z
-0, C, M, L, Z
-0, C, M, L, Z
15
15
15
0.30
0.35
0.35
15
15
15
0.30
0.35
0.35
9
10.5
10.5
8.4...16.8
18...36
36...75
83
84
84
12 IML 10-15-15-3
24 IML 10-15-15-3
48 IML 10-15-15-3
-0, C, M, L, Z
-0, C, M, L, Z
-0, C, M, L, Z
1 Flexible load distribution on double outputs possible up to 75% of the total output power Po nom on one of the 2 outputs. The other
output should not exceed the difference to the total output power Po nom
.
Type Key
24 IML 10 - 12 - 12 -3 C M L Z
Input voltage range Ui
8.4...16.8 V DC .......................................... 12
14...36 V DC .............................................. 24
36...75 V DC .............................................. 48
Series ...................................................................... IML 10
Output voltage for output 1 ................................ 05, 12, 15
Dash: Designates double output unit with two indepen-
dent galvanically isolated outputs ................. -
Output voltage for output 2 ...................................... 12, 15
Operating ambient temperature range TA
–25...60°C .................................................. -3
–40...60°C .................................................. -0
1
Options:
C-pinout ...................................................... C
Surface mount version with pins ................. M
Surface mount version with PCB lid ............ L
Open frame .................................................. Z
1
1 C-pinout excludes option M and vice versa
For delivery lead times contact factory. Some types require a minimum order quantity.
Examples: 48 IML 10-15-15-3: DC-DC converter, input voltage range 36...75 V, 2 galvanically isolated outputs each pro-
viding 15 V, 0.33 A, surface mount version.
24 IML 10-1212-3C: DC-DC converter, input voltage range 18...36 V, C-pinout with outputs ±12 V, ±0.45 A.
24 IML 10-12-3C2: DC-DC converter, input voltage range 18...36 V, C-pinout with one output 12 V, 0.9 A.
Edition 6/4.2000
2/7
Board Mountable
DC-DC Converters
IML 10 Series
Mechanical Data
Dimensions in mm. Tolerances ±0.3 mm unless otherwise indicated.
European
Projection
50.8 (2")
0.8 × 1.2 (0.03 x 0.05") Pins
1.6 (0.06) PCB holes
3.4 (0.13")
3.81(0.15")
14
1
4
10
4.6 (0.18")
PT 2.2
self tapping screws
3.81(0.15")
45.7 (1.8")
Measuring point
of case temperature TC
S09030
Fig. 1
Case IML 10 with standard soldering pins
Weight: <20 g
50.8 (2")
35.5 (1.4")
1 (0.04") Pins
1.2 (0.05") PCB holes
0.5(0.02")
15.2 (0.6")
3
1
2
4
5
09032
Measuring point of
case temperature TC
Fig. 2
Case IML 10 with C pinout (option C) for double output units, pins 6 and 7 are not fitted.
With single output units pins 4, 6 and 7 are not fitted.
Weight: <24 g
48 (1.9")
1
14
4
10
43.2 (1.7")
3.5 (0.14")
S90002
1.2 (0.5")
Fig. 3
Open frame
Weight: <20 g
Edition 6/4.2000
3/7
Board Mountable
DC-DC Converters
IML 10 Series
50.8 (2")
0.8 × 1.2 (0.03 x 0.05") Pins
14
1
10
4
42.4 (1.67")
S09031
Measuring point of
case temperature TC
4.2 (0.17")
Fig. 4
Case IML 10, surface mount version with pins (option M)
Weight: <20 g
50.8 (2")
1
90001
Measuring point of
case temperature TC
Fig. 5
Case IML 10, surface mount version with PCB lib (option L)
Weight: <20 g
Safety and Installation Instructions
Table 4: Pin allocation SMD version (option L)
Table 2: Pin allocation IML, option M and Z
Pin
1
Single output
Vo
Dual output
Vo1
Pin
1
Single output
Dual output
Vi+
Double outputs
Vi+
Vi–
Vi+
Vi–
2
Go
Go
2
Vi–
3
n.c.
Vo2
3
n.c.
n.c.
Vo–
Vo+
Vo–
n.c.
n.c.
n.c.
n.c.
4
n.c.
n.c.
4
n.c.
n.c.
5
n.c.
n.c.
10
11
12
13
14
Go
Vo1–
Vo1+
Vo2–
Vo2+
n.c.
6
n.c.
n.c.
Vo1+
Go
7
n.c.
n.c.
8
n.c.
n.c.
Vo2+
n.c.
9
n.c.
Trim
n.c.
10
11
12
13
14
15
16
17
18
n.c.
SD
SD
Table 3: C pinout (option C)
no pin
no pin
n.c.
no pin
no pin
n.c.
Pin
1
Single output
Dual output
Vi+
Vi–
Vi+
Vi–
2
n.c.
n.c.
3
Vo+
Vo+
Go
n.c.
n.c.
4
no pin
Vo–
Vi–
Vi–
5
Vo–
Vi+
Vi+
Edition 6/4.2000
4/7
Board Mountable
DC-DC Converters
IML 10 Series
Installation Instruction
Isolation
Installation of the DC-DC converters must strictly follow the
national safety regulations in compliance with the enclo-
sure, mounting, creepage, clearance, casualty, markings
and segregation requirements of the end-use application.
The electric strength test is performed as factory test in ac-
cordance with IEC/EN 60950 and UL 1950 and should not
be repeated in the field. Power-One will not honour any
guarantee claims resulting from electric strength field tests.
Connection to the system shall be made via a printed circuit
board according to: Mechanical Data.
Table 5: Electric strength test voltages, clearance and
creepage distances
The units should be connected to a secondary circuit.
Check for hazardous voltages before altering any connec-
tions.
Characteristic
I/O
1.2
O/O
0.1
0.15
-
Unit
kVrms
kV DC
nF
Electric strength
test voltage 1 s
Do not open the module.
1.5
Ensure that a unit failure (e.g. by an internal short-circuit)
does not result in a hazardous condition. See also: Safety
of operator accessible output circuit.
Coupling capacitance
≈1.2
>100
Isulation resistance
at 500 V DC
-
MΩ
Input Fuse
Partial discharge
extinction voltage
Consult
factory
-
kV
To prevent excessive current flowing through the input sup-
ply line in case of a short-circuit across the converter input
an external fuse should be installed in a non earthed input
supply line. We recommend a fast acting fuse F3.15 for
12 IML 10 types, F2A for 24 IML 10 types and F1A for
48 IML 10 types.
Protection Degree
The protection degree of the DC-DC converters is IP 30.
Safety of operator accessible output circuit
If the output circuit of a DC-DC converter is operator acces-
sible, it shall be an SELV circuit according to IEC/EN 60950
related safety standards
Cleaning Agents
In order to avoid possible damage, any penetration of
cleaning fluids has to be prevented, since the power sup-
plies are not hermetically sealed.
The insulation concept table below shows some possible
installation configurations, compliance with which causes
the output circuit of the DC-DC converter to be an SELV cir-
cuit according to IEC/EN 60950 up to a configured output
voltage (sum of nominal voltages if in series or +/– configu-
ration) of 30 V.
Standards and approvals
All DC-DC converters are pending to be UL recognized ac-
cording to UL 1950, UL recognized for Canada to CAN/
CSA C22.2 No. 950-95 and LGA approved to IEC/EN
60950 standards.
However, it is the sole responsibility of the installer to en-
sure the compliance with the relevant and applicable safety
regulations. More information is given in: Technical Infor-
mation: Safety.
The units have been evaluated for:
• Building in
• Supplementary insulation input to output, based on their
maximum input voltage
• The use in a pollution degree 2 environment
• Connecting the input to a secondary circuit which is sub-
ject to a maximum transient rating of 1500 V
The DC-DC converters are subject to manufacturing sur-
veillance in accordance with the above mentioned UL,
CSA, EN and ISO 9001 standards.
Edition 6/4.2000
5/7
Board Mountable
DC-DC Converters
IML 10 Series
Table 6: Insulation concept leading to an SELV output circuit
Conditions Front end
DC-DC converter
Result
Supply
voltage
Minimum required grade
of isolation, to be provided DC output status of the front end
by the AC-DC front end,
including mains supplied from the
Maximum Minimum required safety
Measures to achieve the
specified safety status of the
output circuit
Safety status of
the DC-DC
converter output
circuit
voltage
output circuit
battery charger
front end 1
Mains
≤250 V AC
Basic
≤60 V
Earthed SELV circuit 2
ELV circuit
Operational insulation, pro-
vided by the DC-DC converter
SELV circuit
Input fuse 3 output suppressor Earthed SELV
diode(s) 4, and earthed
output circuit(s) 2
circuit
>60 V
≤60 V
>60 V
Hazardous voltage
secondary circuit
Double or reinforced
SELV circuit
Operational insulation, pro-
vided by the DC-DC converter
SELV circuit
TNV-2 circuit
Supplementary insulation,
based on the maximum input
voltage, provided by the
DC-DC converter
Double or reinforced insu-
lated unearthed hazardous
voltage secondary circuit 5
1 The front end output voltage should match the specified input voltage range of the DC-DC converter.
2 The earth connection has to be provided by the installer according to the relevant safety standard, e.g. IEC/EN 60950.
3 The installer shall provide an approved fuse (type with the lowest rating suitable for the application) in the non-earthed input line di-
rectly at the input of the DC-DC converter (see fig.: Schematic safety concept). For UL’s purpose, the fuse needs to be UL-listed. See
also: Input Fuse.
4 Each suppressor diode should be dimensioned in such a way, that in the case of an insulation fault the diode is able to limit the output
voltage to SELV (<60 V) until the input fuse blows (see fig.: Schematic safety concept).
5 Has to be insulated from earth by basic insulation according to the relevant safety standard, based on the maximum output voltage
from the front end.
10004
Fuse
+
~
Mains
Suppressor
diode
AC-DC
front
DC-DC
con-
Battery
SELV
end
verter
–
~
Earth
connection
Earth
connection
Fig. 6
Schematic safety concept. Use fuse, suppressor diode
and earth connection as per table: Safety concept leading
to an SELV output circuit.
Edition 6/4.2000
6/7
Board Mountable
DC-DC Converters
IML 10 Series
Description of Options
Table 7: Survey of options
Option
Function of option
C-pinout
Characteristic
C
M
L
Surface mount version with pins
Surface mount version with PCB lid
Open frame
Standard pin-out
Macrodense pin-out
Available for all versions
Z
Option C
09119
4
The C-pinout configures the electrically isolated double out-
puts to the "industrial pinout" Vo1+, Vo2– with common
ground Go. With the C-pinout the converter height is in-
creased by the adapter PCB (see also: Mechanical Data).
Top view
50
Option M and L
Surface mount version
Note: Precautions should be taken when reflow soldering
the SMD version. The reflow soldering instructions below
should be strictly adhered to. An inadequate soldering pro-
cess may permanently damage the converter or degrade
its performance and Power-One will not honour any gua-
rantee/warranty claims resulting from damage caused by
ignoring the soldering instructions.
Fig. 8
Proposed solder lands option M
3.6 (1.4")
Foot print
Infrared soldering is not permitted.
The surface mountable version of this product is assem-
bled with high melting point solder (227°C) to ensure that
the solder joints of of the internal components do not de-
grade in the end users SMD soldering process.
8 x 5 (1.9")
This product is only specified for "Forced Convection
Reflow Soldering" (Hot Air). Any conventional soldering
profile is acceptable provided that the restriction curve be-
low is not exceeded at any time during the reflow process.
Fig. 9
Proposed solder lands option L
Tpeak [°C]
11051
240
235
230
225
220
215
210
t [s]
205
50
0
20
30
40
10
Fig. 7
Forced convection reflow soldering restriction curve
measured on pin 2
Accessories
Mounting supports for chassis and DIN-rail mounting.
Edition 6/4.2000
7/7
相关型号:
12IML10-15-15-3C
DC-DC Regulated Power Supply Module, 2 Output, 9W, Hybrid, 2 X 1 INCH, 10.50 MM HEIGHT, MODULE-5
BEL
12IML10-15-15-3M
DC-DC Regulated Power Supply Module, 2 Output, 9W, Hybrid, 2 X 1 INCH, 10.50 MM HEIGHT, MODULE-9
BEL
©2020 ICPDF网 联系我们和版权申明