230H1901-2RD5 [BEL]

AC-DC Regulated Power Supply Module, 1 Output, 168.50 X 111.20 MM, 38.70 MM HEIGHT, METAL, CASE H02, MODULE;
230H1901-2RD5
型号: 230H1901-2RD5
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

AC-DC Regulated Power Supply Module, 1 Output, 168.50 X 111.20 MM, 38.70 MM HEIGHT, METAL, CASE H02, MODULE

文件: 总16页 (文件大小:358K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
H-Family  
AC-DC Converters <100 W  
Benign Environment  
50 W AC-DC Converters  
H-Family  
Single output: series 110H/230H1000  
Dual output:  
series 110H/230H2000  
Triple output: series 110H/230H3000  
Two input voltage ranges suitable for most AC mains  
• Efficient input filter and built-in surge and transient  
suppression circuitry  
• 3 kVrms input to output electric strength test  
• Outputs individually isolated  
• Outputs fully protected against overload  
Safety according to IEC 950  
LGA  
C
Table of Contents........................................... Page  
Description .............................................................. 10 - 62  
Type Survey ............................................................ 10 - 63  
Safety and Installation Instructions ......................... 10 - 63  
Functional Description ............................................ 10 - 64  
Electrical Input Data................................................ 10 - 65  
Electrical Output Data ............................................. 10 - 66  
EMC and Immunity to Input Transients ................... 10 - 69  
Supplementary Data ............................................... 10 - 70  
Description of Options............................................. 10 - 71  
Immunity to Environmental Conditions.................... 10 - 75  
Mechanical Data ..................................................... 10 - 76  
Type Key and Product Marking ............................... 10 - 77  
Description  
The H-family of AC-DC converters represents a broad and  
flexible range of power supplies for use in advanced elec-  
tronic systems. Features include high efficiency, reliability  
and low output voltage noise.  
IEC 950 and have been approved by the safety agencies  
LGA (Germany) and UL (USA). The UL Mark for Canada  
has been officially recognized be regulatory authorities in  
provinces across Canada.  
The converter inputs are protected against surges and tran-  
sients occuring at the source lines. An input over- and  
undervoltage cut-out circuitry disables the outputs if the in-  
put voltage is outside the specified range. The modules in-  
clude an inrush current limitation preventing circuit break-  
ers and fuses from being damaged at switch-on.  
The case design allows operation at nominal load up to  
50°C in a free air ambient temperature. If forced cooling is  
provided, the ambient temperature may exceed 50°C but  
the case temperature should remain below 80°C under all  
conditions.  
A temperature sensor generates an inhibit signal which  
disables the outputs if the case temperature TC exceeds the  
limit. The outputs are automatically re-enabled when the  
temperature drops below the limit.  
All outputs are open- and short-circuit proof and are pro-  
tected against overvoltages by means of built-in suppressor  
diodes. The outputs can be inhibited by a logic signal ap-  
plied to the connector pin 2(i). If the inhibit function is not  
used pin 2 should be connected with pin 23 to enable the  
outputs.  
Various options are available to adapt the converters to in-  
dividual applications.  
The modules may either be plugged into 19 inch rack sys-  
tems according to DIN 41494, or be chassis mounted.  
LED indicators display the status of the converter and allow  
visual monitoring of the system at any time.  
Case: aluminium, black finish, self cooling.  
Dimensions: 38.7 × 111.2 × 168.5 mm. Weight: 770 g  
Full input to output, input to case, output to case and output  
to output isolation is provided. The modules are designed  
and built according to the international safety standard  
10 - 62  
Edition 2/96 - © Melcher AG  
MELCHER  
The Power Partners.  
Benign Environment  
AC-DC Converters <100 W  
H-Family  
Type Survey  
Options see "Descriptions of Options"  
Table 1: Type survey  
Output 1  
Output 2  
Output 3  
Input Voltage Range and Efficiency1  
Option  
Uo nom Io nom  
Uo nom Io nom  
Uo nom Io nom  
Ui min...Ui max  
85...132 V AC  
47...63 Hz  
η min  
%
Ui min...Ui max  
187...255 V AC  
47...63 Hz  
η min  
%
V DC  
A
V DC  
A
V DC  
A
5.1 8.0  
12.0 4.0  
15.0 3.4  
24.0 2.0  
48.0 1.0  
110H1001-2R  
110H1301-2R  
110H1501-2R  
110H1601-2R  
110H1901-2R  
74  
81  
83  
83  
85  
230H1001-2R  
230H1301-2R  
230H1501-2R  
230H1601-2R  
230H1901-2R  
74  
81  
82  
82  
85  
V2, V3  
D1...D8  
12.0 2.0  
15.0 1.7  
12.0 2.0  
15.0 1.7  
110H2320-2  
110H2540-2  
81  
82  
230H2320-2  
230H2540-2  
81  
82  
5.1 5.0  
5.1 5.0  
12.0 0.7  
15.0 0.6  
12.0 0.7  
15.0 0.6  
110H3020-2  
110H3040-2  
79  
79  
230H3020-2  
230H3040-2  
78  
79  
1 Efficiency measured at Ui nom and Io nom  
Safety and Installation Instructions  
Safety  
If the output circuit of an AC-DC converter is operator-ac-  
cessible according to the IEC 950 related safety standards,  
it shall be an SELV circuit (Safety Extra Low Voltage circuit,  
i.e. a circuit, separated from mains by at least basic insula-  
tion, that is so designed and protected such that under nor-  
mal and single fault conditions, the voltage between any  
two conductors and between any conductor and earth does  
not exceed 60 V DC).  
For safety reasons, the modules must be wired via the  
female connector H11 (according to DIN 41612 see sec-  
tion "Accessories") in order to meet national and interna-  
tional safety requirements!  
The connector protective earthing pin is leading. During the  
production process, all transformers and each of the fully  
assembled modules are individually tested for electric  
strength and earth continuity (see "Supplementary Data").  
All electric strength tests are performed as factory tests.  
In the following section an interpretation is provided of the  
IEC 950 safety standard with respect to the safety status of  
the output circuit. However, it is the sole responsibility of the  
installer or user to assure the compliance with the relevant  
and applicable safety standards:  
Installation Instruction  
Installation of the power supply must strictly follow the na-  
tional safety regulations. To observe the safety require-  
ments according to EN 60950/IEC 950, the module shall be  
connected via the female connector type H11 see section  
"Accessories".Other installation methods may not meet the  
safety requirements. The modules do not incorporate any  
fuse. At least one external fuse, installed in the wiring to the  
input is essential! See "Fuse types".  
If the AC-DC converter is installed according to the relevant  
safety regulations its outputs are considered to be SELV  
circuits up to a nominal output voltage of 36 V.  
Whenever the inhibit function is not required, pin 2 (i)  
should be connected to pin 23 to enable the output(s).  
Important Advice  
Electric strength tests should not be repeated in the field. Improper test methods, for example overshooting or oscillating  
test voltages, voltage slopes exceeding 1 kV/µs, internal Y-capacitors not carefully discharged, etc. can cause severe  
damage to switching devices and ICs. Melcher AG will not honour any guarantee/warranty claims resulting from high  
voltage field tests.  
Edition 2/96 - © Melcher AG  
10 - 63  
MELCHER  
The Power Partners.  
H-Family  
AC-DC Converters <100 W  
Benign Environment  
Table 2: H11 connector pin allocation  
Electrical Determination  
H1000  
H2000  
H3000  
Pin  
Ident  
Pin  
Ident  
Pin  
Ident  
Inhibit control input  
Safe Data or ACFAIL  
2
5
i
2
5
i
2
5
i
D or V  
D or V  
D or V  
Output voltage (positive)  
Output voltage (negative)  
8
Vo1+  
Vo1–  
8
8
Vo3+  
Vo3–  
11  
11  
11  
Control input +  
Control input –  
14  
17  
R
G
Output voltage (positive)  
Output voltage (negative)  
14  
17  
Vo2+  
Vo2–  
14  
17  
Vo2+  
Vo2–  
Output voltage (positive)  
Output voltage (negative)  
20  
23  
Vo1+  
Vo1–  
20  
23  
Vo1+  
Vo1–  
20  
23  
Vo1+  
Vo1–  
Protective earthing 1  
26  
26  
26  
AC input voltage  
AC input voltage  
29  
32  
N
P
29  
32  
N
P
29  
32  
N
P
1 Leading pin (pregrounding)  
Degree of Protection  
Condition: Female connector fitted to the unit  
IP 40:  
IP 20:  
All units, except those with options D or V incorporating potentiometer adjustment.  
Type fitted with options D or V incorporating potentiometer.  
Functional Description  
The input voltage is fed via an input filter, an inrush current  
limiter and a bridge rectifier to the input capacitor. This ca-  
pacitor sources a single transistor forward converter. Each  
output is powered by a separate secondary winding of the  
main transformer. The resultant voltages are rectified and  
their ripples smoothed by a power choke. The control logic  
senses the main output voltage Uo1 and generates, with re-  
spect to the maximum admissible output currents, the con-  
trol signal for the primary switching transistor. This signal is  
fed back via a coupling transformer.  
The auxiliary outputs Uo2 and Uo3 are unregulated. Each  
auxiliary output's current is sensed and transferred to the  
main control circuit using a current transformer. If one of the  
outputs is driven into current limit, the other outputs will re-  
duce their output voltages as well because all output cur-  
rents are controlled by the same control circuit.  
2
5
1
Main control circuit  
14  
1
17  
20  
23  
Y
29  
14  
Current  
limitation  
output 2  
17  
8
Current  
limitation  
output 3  
32  
26  
Y
11  
Y
Y
Y
1 Single output modules H1000 (R input)  
Fig. 1  
AC-DC converter block diagram  
10 - 64  
Edition 2/96 - © Melcher AG  
MELCHER  
The Power Partners.  
Benign Environment  
AC-DC Converters <100 W  
H-Family  
Electrical Input Data  
General conditions:  
TA = 25°C, unless TC is specified. – Connector pins 2 and 23 interconnected, R input not connected.  
Table 3: Input data  
Input  
110H  
230H  
Characteristics  
Conditions  
min  
85  
typ  
max  
132  
min  
187  
typ  
max  
255  
Unit  
Ui  
Input voltage range  
Io = 0…Io nom  
TC minTC max  
V AC  
Ui nom Nominal input voltage  
110  
230  
1
Ii  
Input current  
Ui nom, Io nom  
0.78  
0.44  
Arms  
VA  
Si 0  
No-load apparent input power: Ui nom  
Single output  
Double output  
Triple output  
Io1,2,3 = 0  
1
7
7
1.5  
9
9
1
7
7
1.5  
9
9
Si inh Idle apparent input power  
inhibit mode  
2.5  
80  
2.5  
42  
3
Iinr p  
tinr r  
tinr h  
Ri  
Peak inrush current  
Rise time  
Ui = Ui max  
RS = 0 4  
TC = 25°C  
A
200  
300  
µs  
Trailing edge half-life  
Input resistance  
1100  
1600  
TC = 25°C  
450  
2000  
250  
0
800  
8000  
50  
mΩ  
2
RNTC NTC resistance  
Ci Input capacitance  
570  
142  
270  
284  
µF  
Ui abs Input voltage limits  
without any damage  
0
V AC  
1 With multiple output modules, the same condition for each output applies.  
2 Initial switch-on cycle. Subsequent switch on/off cycles increase the inrush current peak value.  
3 Iinr p = Ui/(Rs + Ri + RNTC  
4 RS = source resistance.  
)
Input Under-/Overvoltage Cut-out  
Input fuse  
The modules do not incorporate any fuse. External fuses in-  
stalled in the wiring to the input are essential.  
If the input voltage remains below 0.6 Ui min or exceeds  
1.1 Ui max (approx. values), an internally generated inhibit  
signal disables the output(s). When checking this function  
the absolute maximum input voltage rating Ui abs must be  
carefully considered (see table above).  
Table 4: Recommended fuse types (slow-blow)  
Series  
110H  
230H  
Schurter type  
Part number  
0001.2508  
0001.2508  
SPT 2.5 A 250 V  
SPT 2.5 A 250 V  
Edition 2/96 - © Melcher AG  
10 - 65  
MELCHER  
The Power Partners.  
H-Family  
AC-DC Converters <100 W  
Benign Environment  
Electrical Output Data  
General conditions  
TA = 25°C, unless TC is specified.  
– Connector pins 2 and 23 interconnected, R input not connected.  
Table 5a: Output data  
Output  
Uo nom  
Conditions  
5.1 V  
12 V  
15 V  
Characteristics  
min  
typ  
max  
5.20  
min  
typ  
max  
min  
typ  
max  
Unit  
V
1
Uo1  
Output voltage  
Ui nom, Io nom  
5.00  
11.76  
11.10  
12.24  
12.90  
13.80  
14.70  
13.90  
15.30  
16.10  
17.25  
Uo2/3  
Uo2/3 0  
-
-
Ui min...Ui max  
Io2/3 = 0  
Uo1 L  
Uo2/3 L  
Io nom  
Io L  
Overvoltage prot.  
Output current  
Failure in  
control circuit  
7.5  
-
21  
25  
25  
31  
Ui min...Ui max  
TC min...TC max  
see table 1  
see fig. 2  
Output current  
limitation response  
1
uo1/2/3  
Output voltage noise Ui nom, Io nom  
BW = 20 MHz  
50  
120  
360  
150  
450  
mVrms  
mVpp  
mV  
200  
±50  
Uo1 U  
Static line regulation Ui min...Ui nom  
Ui nom...Ui max  
±20  
±25  
±80  
±120  
±240  
±30  
±150  
Uo2/3 U  
-
±100 ±300  
1
Io nom  
Uo1 I  
Static load regulation Ui nom  
Io = Io nom...0 2  
15  
50  
35  
120  
45  
150  
Uo2/3 I  
Uo1 Ic  
Uo2/3 Ic  
-
±5  
-
see fig. 3  
±10  
see fig. 4  
±15  
Static cross load  
regulation 3  
Ui nom  
Io = Io nom...0 4  
±15  
±30  
±45  
see fig. 3  
see fig. 4  
Table 5b: Output data  
Output  
Uo nom  
24 V  
48 V  
Characteristics  
Conditions  
Ui nom, Io1 nom  
Io1 nom  
min  
typ  
max  
min  
typ  
max  
Unit  
V
Uo1  
Output voltage  
Overvoltage prot.  
Output current  
23.52  
24.48  
47.04  
48.96  
Uo L  
41  
85  
Io1 nom  
Uo1 L  
Ui min...Ui max  
TC min...TC max  
see table 1  
see fig. 2  
Output current  
limitation response  
uo1  
Output voltage noise Ui nom, Io1 nom  
BW = 20 MHz  
240  
480  
mVrms  
mVpp  
mV  
720  
1440  
±480  
Uo1 U  
Static line regulation Ui min...Ui nom  
±30  
±240  
±30  
Ui nom...Ui max  
Io1 nom  
Uo1 I  
Static load regulation Ui nom  
Io1 = Io1 nom...0  
70  
240  
150  
480  
1 With multiple output modules, the same condition for each output applies.  
2 Condition for specified output. With multiple output modules, other output(s) loaded with constant current Io = Io nom  
.
3 Condition for non-specified output, individually tested, other output(s) loaded with constant current Io = Io nom  
4 Multiple output modules.  
.
10 - 66  
Edition 2/96 - © Melcher AG  
MELCHER  
The Power Partners.  
Benign Environment  
AC-DC Converters <100 W  
H-Family  
Output Protection  
Uo  
Uo nom  
Each output is protected against overvoltages which could  
occur due to a failure of the internal control circuit. Voltage  
suppressor diodes (which under worst case condition may  
become a short circuit) provide the required protection.The  
suppressor diodes are not designed to withstand externally  
applied overvoltages. Overload at any of the outputs will  
cause a shut-down of all outputs.  
Io nom  
IoL1  
IoL2,IoL3  
1.0  
0.95  
Io1  
0.5  
Io2,Io3  
Io  
Io nom  
0
0.5  
1.0  
1.2  
Fig. 2  
Typical output voltage Uo versus output currents Io  
Uo2/3 [V]  
Uo2/3 0  
Uo2/3 [V]  
Uo2/3 0  
16  
13  
Io1 nom  
Io1 nom  
0.5 • Io1 nom  
Io1 = 0 A  
0.5 • Io1 nom  
Io1 = 0 A  
15  
14  
12  
11  
Io2/3  
Io2/3  
Io2/3 nom  
Io2/3 nom  
0.25  
0.75  
0
0.5  
1.0  
0.25  
0.75  
0
0.5  
1.0  
Fig. 3  
Fig. 4  
H2540/3040: Uo2/3 (typ.) versus Io2/3 with different Io1  
H2320/3020: Uo2/3 (typ.) versus Io2/3 with different Io1  
Parallel and Series Connection  
Main outputs of equal nominal voltage can be connected in  
parallel. It is important to assure that the main output of a  
multiple output module is forced to supply a minimum cur-  
rent of 0.1 A to enable correct operation of its own auxiliary  
outputs. Outputs one and two of a dual output unit may be  
connected parallel without a minimum current requirement  
at the main output. Outputs two and three of a triple output  
unit can be connected in parallel.  
Main or auxiliary outputs can be connected in series with  
any other output of the same or another module. In series  
connection, the maximum output current is limited by the  
lowest current limit. Output ripple and regulation values are  
added. Connection wiring should be kept as short as possi-  
ble.  
If output terminals are connected together in order to estab-  
lish multi-voltage configurations, e.g. +5.1 V, ±12 V etc. the  
common ground connecting point should be as close as  
possible to the connector of the converter to avoid exces-  
sive output ripple voltages.  
In parallel operation, one or more of the outputs may oper-  
ate continuously in current limit which will cause an in-  
crease in case temperature. Consequently, a reduction of  
the max. ambient temperature by 10 K is recommended.  
Inhibit (i Input)  
The outputs of the module may be enabled or disabled by  
means of a logic signal (TTL, CMOS, etc.) applied to the  
inhibit input. If the inhibit function is not required, connect  
the inhibit pin 2 to pin 23 to enable the outputs (active low  
logic, fail safe).  
I inh [mA]  
U inh= 2.4 V  
U inh= 0.8 V  
2.0  
1.6  
1.2  
The reference for the inhibit signal is the negative pin of out-  
put 1.  
0.8  
0.4  
Uo = on  
Uo = off  
N
Vo+  
0
-0.4  
-0.8  
I inh  
U inh  
i
U inh [V]  
-50  
-30  
-10 0 10  
30  
50  
Vo–  
P
-40  
-20  
20  
40  
Fig. 5  
Fig. 6  
Typical inhibit current Iinh versus inhibit voltage Uinh  
Definition of inhibit voltage and current  
Edition 2/96 - © Melcher AG  
10 - 67  
MELCHER  
The Power Partners.  
H-Family  
AC-DC Converters <100 W  
Benign Environment  
Table 6: Inhibit data  
Characteristics  
Conditions  
min  
50  
2.4  
–60  
typ  
max  
0.8  
50  
Unit  
Uinh  
Inhibit input voltage causing  
switched on  
switched off  
Ui min...Ui max  
V DC  
output voltage being…  
Iinh  
Inhibit current  
Uinh = 0  
–100  
–220  
µA  
Output  
Uo nom  
Output Response  
The reaction of the outputs is similar whether the input volt-  
age is applied or the inhibit is switched low.  
0.1  
0
An output voltage overshoot will not occur when the module  
is turned on or off.  
t
tr  
tf  
Ui  
1
0
t
t
Inhibit  
1
Fig. 7  
Output response as a function of input voltage (on/off  
switching) or inhibit control  
0
Table 7: Output response time  
Type of Converter  
tr at Po = 0 and tf at Po =Po nom  
tr and tf at Po =3/4 Po nom  
tr at Po =Po nom  
Unit  
ms  
typ  
max  
typ  
max  
typ  
max  
H1001-2R  
H1301-2R  
H1501-2R  
H1601-2R  
H1901-2R  
3
5
17  
25  
3
8
17  
30  
5
10  
15  
20  
85  
25  
40  
50  
70  
230  
3
17  
5
25  
8
30  
15  
50  
45  
150  
35  
100  
H2320-2  
H2540-2  
10  
8
40  
30  
15  
10  
50  
40  
25  
20  
80  
60  
H3020-2  
H3040-2  
30  
20  
85  
70  
45  
30  
130  
90  
75  
50  
210  
150  
Conditions:  
R input not used. For multiple output modules the figures indicated in the table above relate to the output which reacts  
slowest. All outputs are resistively loaded. Variation of the input voltage within Ui min...Ui max does not influence the values.  
Programmable Voltage (R Input)  
or: Between pin 14 and pin 20 (Uo > Uo nom) to achieve  
an output voltage adjustment range of approximately  
Uo = 100...110% of Uo nom  
As a standard feature single output modules offer an ad-  
justable output voltage identified by letter R in the type des-  
ignation. The control input R (pin 14) accepts either a con-  
trol voltage Uext or a resistor Rext to adjust the desired out-  
put voltage. When not connected, the control input auto-  
matically sets the output voltage to Uo nom.The control input  
is protected against external overvoltage up to 8 V max.  
(Uo - 2.5 V)  
R'ext 4 k• ––––––––––––––––  
2.5 V• (Uo/Uo nom - 1)  
For output voltages Uo > Uo nom, the minimum input voltage  
according to "Electrical Input Data" increases proportionally  
a) Adjustment by means of an external control voltage Uext  
between pin 14 (R) and pin 17 (G):  
to Uo/Uo nom  
.
The control voltage range is 0...2.75 V and allows an  
adjustment in the range of approximately  
Warning  
The value of R'ext should never be less than 47 kto avoid  
damage to the unit! R inputs may be parallel connected, but  
1/Rtot = 1/R1 + 1/R2 +.... should be considered.  
Uo = 0...110% Uo nom  
Uo  
.
Uext ––––––– • 2.5 V  
Uo nom  
Vo1+  
Vi+  
Vo1+  
Vi+  
29  
2.5 V 4 kΩ  
20  
20  
14  
29  
2.5 V 4 kΩ  
b) Adjustment by means of an external resistor:  
Depending upon the value of the required output volt-  
age, the resistor shall be connected  
either: Between pin 14 and pin 17 (Uo < Uo nom) to  
achieve an output voltage adjustment range of approx.  
Uo = 0...100% Uo nom  
R'ext  
R
R
+
14  
control  
circuit  
control  
circuit  
Uext  
Rext  
G
G
17  
23  
17  
23  
Vo1–  
Vo1–  
Vi–  
Vi–  
32  
32  
Uo  
Uo nom - Uo  
R
ext 4 k• ––––––––  
Fig. 8  
Output voltage control by means of the R input  
10 - 68  
Edition 2/96 - © Melcher AG  
MELCHER  
The Power Partners.  
Benign Environment  
AC-DC Converters <100 W  
H-Family  
Table 8a: Rext for Uo < Uo nom (conditions: Ui nom, Io nom, rounded up to resistor values E 96); R'ext = ∞  
Uo nom = 5.1 V  
Uo nom = 12 V  
Uo nom = 15 V  
Uo nom = 24 V  
Uo nom = 48 V  
Uo [V]  
Rext [k]  
Uo [V]  
Rext [k]  
Uo [V]  
Rext [k]  
Uo [V]  
Rext [k]  
Uo [V]  
Rext [kΩ]  
0.5  
1.0  
1.5  
2.0  
2.5  
3.0  
3.5  
4.0  
4.5  
5.0  
0.432  
0.976  
1.65  
2.61  
3.83  
5.76  
8.66  
14.7  
30.1  
2.0  
3.0  
4.0  
5.0  
6.0  
7.0  
8.0  
9.0  
10.0  
11.0  
0.806  
1.33  
2.0  
2.87  
4.02  
5.62  
8.06  
12.1  
20.0  
44.2  
2.0  
4.0  
6.0  
8.0  
9.0  
10.0  
11.0  
12.0  
13.0  
14.0  
0.619  
1.47  
2.67  
4.53  
6.04  
8.06  
11.0  
16.2  
26.1  
56.2  
4.0  
6.0  
8.0  
10.0  
12.0  
14.0  
16.0  
18.0  
20.0  
22.0  
0.806  
1.33  
2.0  
2.87  
4.02  
5.62  
8.06  
12.1  
20.0  
44.2  
8.0  
12.0  
16.0  
20.0  
24.0  
28.0  
32.0  
36.0  
40.0  
44.0  
0.806  
1.33  
2.0  
2.87  
4.02  
5.62  
8.06  
12.1  
20.0  
44.2  
200.0  
Table 8b: R'ext for Uo > Uo nom (conditions: Ui nom, Io nom, rounded up to resistor values E 96); Rext = ∞  
Uo nom = 5.1 V  
Uo [V] R'ext [k]  
Uo nom = 12 V  
Uo nom = 15 V  
Uo nom = 24 V  
Uo nom = 48 V  
Uo [V]  
R'ext [k]  
Uo [V]  
R'ext [k]  
Uo [V]  
R'ext [k]  
Uo [V]  
R'ext [kΩ]  
5.15  
5.20  
5.25  
5.30  
5.35  
5.40  
5.45  
5.50  
464  
215  
147  
110  
12.1  
12.2  
12.3  
12.4  
12.5  
12.6  
12.7  
12.8  
13.0  
13.2  
1780  
909  
619  
464  
383  
316  
274  
249  
200  
169  
15.2  
15.4  
15.6  
15.8  
16.0  
16.2  
16.4  
16.5  
1470  
750  
511  
383  
332  
274  
237  
226  
24.25  
24.50  
24.75  
25.00  
25.25  
25.50  
25.75  
26.00  
26.25  
26.40  
3160  
1620  
1100  
825  
715  
590  
511  
453  
402  
383  
48.5  
49.0  
49.5  
50.0  
50.5  
51.0  
51.5  
52.0  
52.5  
52.8  
6810  
3480  
2370  
1780  
1470  
1270  
1100  
953  
90.9  
78.7  
68.1  
61.9  
845  
806  
EMC and Immunity to Input Transients  
A metal oxide VDR together with an input filter form an ef-  
fective protection against input transient voltages which  
typically occur in most installations.The H-Family has been  
successfully tested to the following specifications:  
Electromagnetic Immunity  
Table 9: Immunity type tests  
2
Electrostatic  
discharge  
IEC 801-2  
(1991-04)  
2
2
1
contact discharge 4000 Vp  
to case,  
1/50 ns  
330 Ω  
50 Ω  
10 positive and  
10 negative  
yes  
yes  
yes  
2
2
Electric field  
IEC 801-3  
(1984)  
antenna in  
1m distance  
3 V/m sine wave mo-  
dulated w. 1 kHz  
26…1000 MHz  
Fast transient/  
burst  
IEC 801-4  
(1988)  
i/c, +i/–i  
500 Vp bursts of 5/50 ns  
5 kHz rep. rate  
transients with  
1 min positive  
1 min negative  
bursts per  
15 ms burst  
coupling mode  
duration and a  
300 ms period  
1
Transient  
IEC 801-5  
(Draft1993-01)  
1
i/c  
500 Vp  
500 Vp  
1.2/50 µs  
12 Ω  
2 Ω  
5 pos. and 5 neg. yes  
impulses per  
coupling mode  
+i/–i  
1 Normal operation, no deviation from specifications  
2 Normal operation, temporary deviation from specs possible  
3 i = input, o = output, c = case  
Edition 2/96 - © Melcher AG  
10 - 69  
MELCHER  
The Power Partners.  
H-Family  
AC-DC Converters <100 W  
Benign Environment  
Electromagnetic Emissions  
Table 10: Emissions at Ui nom and Io nom  
Series  
Standard  
EN 55011, 1991 1  
EN 55022, 19872  
30 MHz  
<B  
<B  
30 MHz  
<B  
<B  
110H  
230H  
1
2
Identical with CISPR 11 (1990-09) and VDE 0875 part 11 (1992-07)  
Identical with CISPR 22 (1985) and FCC Part 15, VDE 0878 part 3 (1989-11)  
Supplementary Data  
Isolation  
Important Advice  
Testing by applying AC voltages will result in high and  
dangerous leakage currents through the Y-capacitors  
(see fig. 1). Melcher will not honour any guarantee/war-  
ranty claims resulting from high voltage field tests. Ref-  
erence is also made to chapter: "Safety and Installation  
Instructions".  
Input to output electric strength tests, in accordance with  
the safety standards IEC 950, EN 60950, VDE 0805 and  
EN 41003 are performed as factory tests and should not be  
repeated in the field.  
Table 11: Electric strength test voltage, insulation resistance, clearance and creepage distances  
Characteristic  
Input to output  
Input to case  
Output to case Output to output Unit  
Values according to IEC 950  
Electric strength  
test voltage  
DC: 1 s  
AC: 50 Hz, 1 min  
4243 1  
3000 1  
300  
4.0  
2122  
1500  
300  
2.0  
707  
500  
100  
1.0  
300  
200  
V
Insulation resistance at 500 V DC  
MΩ  
Clearance and  
0.9  
mm  
creepage distances  
1 Only subassemblies performance in accordance with IEC 950  
Display Status of LEDs  
Uo1 > 0.95…0.98Uo1 adj  
Fig. 9  
LEDs "OK" and "i" status versus input voltage  
OK  
Conditions: Io Io nom, TC TC max, Uinh 0.8 V  
i
Ui  
U
i uv = undervoltage lock-out, Ui ov = overvoltage lock-out  
Ui uv Ui min  
Ui max Ui ov Ui abs  
Uo1 > 0.95…0.98Uo1 adj Uo1 < 0.95…0.98Uo1 adj  
OK  
Io L  
LED "OK" status versus output current  
Conditions: Ui min...Ui max, TC TC max, Uinh 0.8 V  
Io  
Io nom  
IoL  
LED "i"versus case temperature  
Conditions: Ui min...Ui max, Io Io nom, Uinh 0.8 V  
i
i
TC  
TC max  
TPTC threshold  
Uinh threshold  
LED "i"versus Uinh  
Conditions: Ui min...Ui max, Io Io nom, TC TC max  
Ui inh  
+0.8 V  
+2.4 V  
+50 V  
-50 V  
LED off  
LED Status undefined  
LED on  
10 - 70  
Edition 2/96 - © Melcher AG  
MELCHER  
The Power Partners.  
Benign Environment  
AC-DC Converters <100 W  
H-Family  
Description of Options  
Table 12: Survey of options  
Option  
D 1  
Function of Option  
Characteristic  
Input and/or output undervoltage monitoring circuitry  
Input and output undervoltage monitoring circuitry  
Safe data signal output (D1...D8)  
V 1 2  
ACFAIL signal according to VME specifications ( V2, V3)  
1 Option D excludes option V and vice versa  
2 Only available with main output voltage Uo1 = 5.1 V  
Option D Undervoltage monitor  
The input and/or output undervoltage monitoring circuit op-  
erates independently of the built-in input undervoltage lock-  
out circuit. A logic "low" (JFET output) or "high" signal (NPN  
output) is generated at pin 5 as soon as one of the moni-  
tored voltages drops below the preselected threshold level  
Ut. The return for this signal is Vo1– (pin 23). The D output  
recovers when the monitored voltage(s) exceed(s) Ut+Uh.  
The threshold level Ut is either adjustable by a potentio-  
meter, accessible through a hole in the front cover, or is fac-  
tory adjusted to a fixed value specified by the customer.  
Option D exists in various versions D1...D8 as shown in the  
following table.  
Table 13: Undervoltage monitor functions  
Output type  
JFET NPN  
Monitoring  
Minimum adjustment range  
of threshold level Ut  
Typical hysteresis Uh [% of Ut]  
for Ut min...Ut max  
Ui  
Uo1  
Uti  
Uto  
Uhi  
Uho  
2.3...1  
D1  
D2  
D3  
D4  
D5  
D6  
D7  
D8  
no  
yes  
yes  
no  
yes  
no  
3.5 V...48 V 1  
1
1
Ui min...Ui max  
Ui min...Ui max  
3.0...0.5  
3.0...0.5  
2
2
yes  
yes  
0.95...0.98 Uo1  
0.95...0.98 Uo1  
"0"  
"0"  
1 Threshold level adjustable by potentiometer (not recommended for mobile applications)  
2 Fixed value between 95% and 98% of Uo1 (tracking)  
JFET output (D1…D4):  
Vo1+  
N
20  
5
29  
Connector pin D is internally connected via the drain-  
source path of a JFET (self-conducting type) to the nega-  
tive potential of output 1. UD 0.4 V (logic low) corresponds  
to a monitored voltage level (Ui and/or Uo1) < Ut. The cur-  
rent ID through the JFET should not exceed 2.5 mA. The  
JFET is protected by a 0.5 W Zener diode of 8.2 V against  
external overvoltages.  
Rp  
ID  
D
U
D 6 V  
P
32  
23  
Ui, Uo1 status  
Ui or Uo1 < Ut  
D output, UD  
Vo1–  
Vo1+  
low, L, UD 0.4 V at ID = 2.5 mA  
high, H, ID 25 µA at UD = 5.25 V  
Fig. 10  
Ui and Uo1 > Ut + Uh  
Options D1...D4, JFET output  
NPN output (D5...D8):  
N
20  
5
29  
Connector pin D is internally connected via the collector-  
emitter path of a NPN transistor to the negative potential of  
output 1. UD < 0.4 V (logic low) corresponds to a monitored  
voltage level (Ui and/or Uo1) > Ut + Uh. The current ID  
through the open collector should not exceed 20 mA. The  
NPN output is not protected against external overvoltages.  
UD should not exceed 40 V.  
Rp  
ID  
D
UD  
P
23  
32  
Ui, Uo1 status  
Ui or Uo1 < Ut  
D output, UD  
Vo1–  
high, H, ID 25 µA at UD = 40 V  
low, L, UD 0.4 V at ID = 20 mA  
Fig. 11  
Ui and Uo1 > Ut + Uh  
Options D5...D8, NPN output  
Edition 2/96 - © Melcher AG  
10 - 71  
MELCHER  
The Power Partners.  
H-Family  
AC-DC Converters <100 W  
Benign Environment  
UD  
Uti  
Uhi  
Threshold tolerances and hysteresis:  
If Ui is monitored, the internal input voltage after the input  
filter and rectifier is measured. Consequently this voltage  
differs from the voltage at the connector pins by the voltage  
drop Uti across the input filter. The value of Uti depends  
upon the input voltage range, threshold level Ut, tempera-  
ture and input current. The input current is a function of the  
input voltage and the output power.  
UD high  
P
P
P
P
P
P
UD low  
Ui  
Uti  
Fig. 12  
Definition of Uti, Uti and Uhi (JFET output)  
Input voltage monitoring  
NPN  
UD  
UD high  
3
3
3
3
UD low  
0
t
t
ID  
ID high  
ID low  
0
JFET UD  
UD high  
UD low  
0
t
t
1
4
4
4
th  
tlow min  
tlow min  
tlow min  
thigh min  
Uo1  
Uo1 nom  
1
th  
1
0.95  
0
Ui [V DC]  
Uti +Uhi  
Uti  
t
0
Input voltage failure  
Switch-on cycle  
Input voltage sag  
Switch-on cycle and subsequent  
input voltage failure  
Output voltage monitoring  
NPN UD  
2
UD high  
UD low  
0
t
t
ID  
ID high  
ID low  
0
UD  
JFET  
UD high  
UD low  
0
t
t
4
tlow min  
Uo1  
Uo1 nom  
Uto +Uho  
Uto  
1
2
With output voltage monitoring the hold-up time th = 0  
The D signal remains high if the D output is connected to  
an external source.  
3
tlow min = 40...200 ms, typically 80 ms  
0
Output voltage failure  
Fig. 13  
Relationship between Ui, Uo1, UD, ID and Uo1/Uo nom versus time.  
10 - 72  
Edition 2/96 - © Melcher AG  
MELCHER  
The Power Partners.  
Benign Environment  
AC-DC Converters <100 W  
H-Family  
Option V ACFAIL signal (VME)  
Formula for threshold level for desired value of th:  
This option defines an undervoltage monitoring circuit  
for the input or the input and main output voltage  
(Uo1 nom = 5.1 V only) equivalent to option D and generates  
the ACFAIL signal (V signal) which conforms to the VME  
standard. The low state level of the ACFAIL signal is speci-  
fied at a sink current of IV = 48 mA to UV 0.6 V (open-col-  
lector output of a NPN transistor).The pull-up resistor feed-  
ing the open-collector output should be placed on the VME  
backplane.  
2 • Po • (th + 0.3 ms) • 100  
––––––––––––––––––––– + Ui min  
Ci min η  
2
Uti  
=
where as:  
Ci min = minimum internal input capacitance [mF], accord-  
ing to table below  
Po  
h
th  
= output power [W]  
= efficiency [%]  
= hold-up time [ms]  
Ui min = minimum input voltage [V]  
After the ACFAIL signal has gone low, the VME standard  
requires a hold-up time th of at least 4 ms before the 5.1 V  
output drops to 4.875 V when the 5.1 V output is fully  
loaded.This hold-up time th is provided by the internal input  
capacitance. Consequently the working input voltage and  
the threshold level Uti should be adequately above the mini-  
mum input voltage Ui min of the converter so that enough  
energy is remaining in the input capacitance.  
Uti = threshold level [V]  
Remarks:  
The threshold level Uti of option V2 and V3 is adjusted dur-  
ing manufacture to a value according to table "Undervol-  
tage monitor functions", section "Option D").  
A decoupling diode should be connected in series with the  
input to avoid the input capacitance discharging through  
other loads connected to the same source voltage.  
Table 14: Factory potentiometer setting of Uti  
Types  
Ci min  
Uti  
110H  
0.25  
94  
230H  
0.05  
200  
5
Unit  
mF  
V DC  
ms  
th  
5
voltage(s) exceed(s) Ut + Uh. The threshold level Ut is ad-  
justable by a potentiometer accessible through a hole in the  
front cover.  
Option V operates independently of the built-in input under-  
voltage lock-out circuit. A logic "low" signal is generated at  
pin 5 as soon as one of the monitored voltages drops below  
the preselected threshold level Ut. The return for this signal  
is Vo1– (pin 23).The V output recovers when the monitored  
Versions V2 and V3 are available as shown below.  
Table 15: Undervoltage monitor functions  
V output  
(VME compatible)  
Monitoring  
Minimum adjustment range  
of threshold level Ut  
Uti Uto  
Typical hysteresis Uh [% of Ut]  
for Ut min...Ut max  
Ui  
Uo1  
Uhi  
Uho  
1
V2  
V3  
yes  
yes  
no  
Ui min...Ui max  
Ui min...Ui max  
3.0...0.5  
3.0...0.5  
-
1
2
yes  
0.95...0.98 Uo1  
"0"  
1 Threshold level adjustable by potentiometer (not recommended for mobile applications)  
2 Fixed value between 95% and 98% of Uo1 (tracking), output undervoltage monitoring is not a requirement of VME standard  
V output (V2, V3):  
Connector pin V is internally connected to the open collec-  
tor of a NPN transistor. The emitter is connected to the  
negative potential of output 1. UV 0.6 V (logic low) corre-  
sponds to a monitored voltage level (Ui and/or Uo1) < Ut.  
The current IV through the open collector should not exceed  
50 mA. The NPN output is not protected against external  
overvoltages. UV should not exceed 80 V.  
Vo1+  
N
29  
20  
5
Rp  
IV  
V
UV  
Ui, Uo1 status  
Ui or Uo1 < Ut  
V output, UV  
P
23  
32  
Vo1–  
low, L, UV 0.6 V at IV = 50 mA  
high, H, IV 25 µA at UV = 5.1 V  
Fig. 14  
Ui and Uo1 > Ut + Uh  
Output configuration of options V2 and V3  
Edition 2/96 - © Melcher AG  
10 - 73  
MELCHER  
The Power Partners.  
H-Family  
AC-DC Converters <100 W  
Benign Environment  
Threshold tolerances and hysteresis:  
If Ui is monitored, the internal input voltage is measured af-  
ter the input filter and rectifier. Consequently this voltage  
differs from the voltage at the connector pins by the voltage  
drop Uti across input filter and rectifier. The value of Uti  
depends upon the input voltage range, threshold level Ut,  
temperature and input current. The input current is a func-  
tion of input voltage and output power.  
UV  
Uti  
Uhi  
UV high  
P
P
P
P
P
P
UV low  
Ui  
Uti  
Fig. 15  
Definition of Uti, Uti and Uhi  
Input voltage monitoring  
2
2
2
tlow min  
tlow min  
tlow min  
V2  
UV  
3
3
3
UV high  
4
2
4
2
UV low  
0
t
t
tlow min  
tlow min  
V3  
UV  
3
3
3
UV high  
UV low  
0
1
1
th  
th  
Uo1  
5.1 V  
4.875 V  
2.0 V  
0
t
Ui [V DC]  
Uti + Uhi  
Uti  
t
0
Input voltage failure  
Switch-on cycle  
Input voltage sag  
Switch-on cycle and subsequent  
input voltage failure  
Output voltage monitoring  
V2 UV  
UV high  
4
4
UV low  
0
2
tlow min  
V3 UV  
UV high  
3
3
4
UV low  
0
Uo1  
5.1 V  
4.875 V  
2.0 V  
0
1 VME request: minimum 4 ms  
Ui  
2 tlow min = 40...200 ms, typically 80 ms  
3 UV level not defined at Uo1 < 2.0 V  
Uti + Uhi  
Uti  
4 The V signal drops simultaneously with the output voltage, if the  
pull-up resistor RP is connected to Vo1+. The V signal remains  
high if RP is connected to an external source.  
0
Output voltage failure  
Fig. 16  
Relationship between Ui, Uo1, UV, IV and Uo1/Uo nom versus time.  
10 - 74  
Edition 2/96 - © Melcher AG  
MELCHER  
The Power Partners.  
Benign Environment  
AC-DC Converters <100 W  
H-Family  
Immunity to Environmental Conditions  
Table 16: Mechanical stress  
Test Method  
Standard  
Test Conditions  
Ca  
Ea  
Eb  
Fc  
Damp heat  
steady state  
DIN 40046 part 5  
IEC 68-2-3  
Temperature:  
Relative humidity:  
Duration:  
40± 2 °C  
93 +2/-3  
%
21 days  
Unit not operating  
Shock  
(half-sinusoidal)  
DIN 40046 part 7  
IEC 68-2-27  
MIL-STD-810D section 516.3  
Acceleration amplitude:  
Bump duration:  
Number of bumps:  
15 gn = 147 m/s2  
11 ms  
18 (3 each direction)  
Unit operating  
Continuous shock  
(half-sinusoidal)  
DIN 40046 part 26  
IEC 68-2-29  
MIL-STD-810D section 516.3  
Acceleration amplitude:  
Bump duration:  
Number of bumps:  
10 gn = 98 m/s2  
16 ms  
6000 (1000 each direction)  
Unit operating  
Vibration  
(sinusoidal)  
DIN 40046 part 8  
IEC 68-2-6  
MIL-STD-810D section 514.3  
Frequency (1 Oct/min):  
Acceleration amplitude:  
Test duration:  
10...150 Hz  
2 gn = 20 m/s2  
3.75 h (1.25 h each axis)  
Unit operating  
Thermal considerations  
Table 17: Temperature specifications, values given are for an air pressure of 800...1200 hPa (800...1200 mbar)  
Characteristic  
min  
-10  
-10  
–25  
max  
50  
Unit  
TA  
TC  
TS  
Standard operational ambient temperature range -2  
°C  
Standard operational case temperature range -2, overtemp. lock-out (PTC) above TC max  
Storage temperature range -2  
80  
100  
Io nom [%]  
Basically the available output power is limited by thermal  
characteristics. Operation at higher temperatures with  
nominal output currents is also possible if forced cooling  
can be provided (heat sink, fan, etc.).  
110  
100  
90  
Io nom (forced cooling)  
Example: Sufficient forced cooling allowsTA max = 65°C. A  
simple check of the case temperature TC (TC 80°C) at full  
load ensures correct operation of the system (temperature  
measurement point on the case see "Mechanical Data").  
Io nom  
each output  
(convection cooling)  
80  
70  
60  
50  
40  
30  
20  
10  
0
TC max  
In general: For an ambient temperature of 65°C with only  
convection cooling, the maximum permissible current for  
each output is approx. 50% of it's nominal value.  
Table 18: MTBF  
Values at specified Module Types Ground Benign Unit  
TA [°C]  
TA min  
40  
50  
60  
70  
80  
Case Temperature  
40°C  
MTBF  
H1000  
H2000  
H3000  
384'000  
306'000  
270'000  
h
Fig. 17  
Output derating versus ambient temperature under con-  
vection and forced cooling conditions  
Edition 2/96 - © Melcher AG  
10 - 75  
MELCHER  
The Power Partners.  
H-Family  
AC-DC Converters <100 W  
Benign Environment  
Mechanical Data  
Dimensions in mm. Tolerances ±0.3 mm unless otherwise indicated.  
European  
Projection  
Mounting holes for retaining clips V  
Male connector H 11 according to DIN 41 612  
Front plate  
100 ±0.6  
103  
M 3; depth = 4 mm  
(chassis mount)  
Main face  
Rear face  
Measurement point for  
case temperatureTC  
22  
Mounting plane of  
connector H11  
(11.6)  
88  
111.2 ±0.8  
38.7  
Back plate  
94.5 ±0.1  
95 ±0.5  
17.25  
12.17  
7.09  
0
OK (LED green)  
Inhibit i (LED red)  
Potentiometer (option D or V)  
Fig. 18  
Case H02, weight 770 g (approx.)  
10 - 76  
Edition 2/96 - © Melcher AG  
MELCHER  
The Power Partners.  
Benign Environment  
AC-DC Converters <100 W  
H-Family  
Type Key and Product Marking  
Type Key  
230 H 2 5 40 -2 R D V  
Input voltage range Ui:  
85...132 V AC ........... 110  
187...255 V AC ........... 230  
Family ............................................................................. H  
Number of outputs ...................................................... 1...3  
Output 1, Uo1 nom  
:
5.1 V ............... 0  
12 V ............... 3  
15 V ............... 5  
24 V ............... 6  
48 V ............... 9  
Single output modules  
Output 2 and 3, Uo2 nom, Uo3 nom  
............. 01  
12 V ............. 20  
15 V ............. 40  
:
Ambient temperature range TA:  
(operational)  
-10…50°C .............. -2  
Output voltage control input (single output modules only) R  
Options:  
Save data signal (D1...D8, to be specified)..................... D 1  
ACFAIL signal (V2, V3, to be specified)...........................V 1  
1 Option D excludes option V and vice versa  
Example:  
230H1501-2RD3: AC-DC converter, input voltage range 187...255 V AC, providing output with 15 V/3.4 A;  
equipped with an output voltage control input and undervoltage monitoring.  
Accessories: Front panels, female connectors, mounting facilities, etc. please refer to section "Accessories".  
Product Marking (refer also to "Mechanical Data")  
Main face: Basic type designation, applicable safety approval and recognition marks, warnings, pin allocation, Melcher  
patents and company logo.  
Front plate: Identification of LEDs and potentiometer.  
Back plate: Specific type designation, input voltage range, nominal output voltage(s) and current(s), pin allocation of op-  
tions and auxiliary functions, external fuse specification and degree of protection.  
Rear face: Label with batch no., serial no. and data code comprising production site, modification status of the main PCB,  
date of production. Confirmation of successfully passed final test.  
Edition 2/96 - © Melcher AG  
10 - 77  
MELCHER  
The Power Partners.  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY