Industrial Environment  
DC-DC Converters <40Watt  
IMS 7 Series  
7 Watt DC-DC Converters  
IMS 7 Series  
Input to output electric strength test 1500 V DC  
Input voltage ranges: 14...36 V DC and 36...75 V DC  
Single and double outputs of 3.3, 5, 12, 15, 24 V DC  
Wide input voltage ranges  
Electrical isolation, single and double output units  
High efficiency (typ. 84%)  
Emissions below EN 55 022 level B  
Immunity to IEC/EN 61000-4-2, -3, -4, -5 and -6  
Inhibit input, output voltage adjustable  
• Flex power: Flexible load distribution  
No load and short-circuit proof  
10.5  
0.42"  
25.4  
1.0"  
50.8  
2.0"  
Operating ambient temperature range –25...71°C  
High reliability and no derating  
2" × 1" case with 10.5 mm profile  
• Supplementary insulation  
Safety according to IECEN 60950, UL 1950  
LGA  
C
Summary  
The IMS 7 series of board mountable 7 Watt DC-DC con-  
verters has been designed according to the latest industry  
requirements and standards. The converters are particu-  
larly suitable for use in industry or telecommunications  
where variable input voltages or high transient voltages are  
prevalent.  
60 V DC. They are designed and built according to the in-  
ternational safety standards IEC/EN 60950, UL 1950, CAN/  
CSA C22.2 No. 950-95 and are LGA and UL marked.  
A special feature is their small case size, 2" × 1" with  
10.5 mm profile.  
The circuit comprises of integrated planar magnetics and  
all components are automatically assembled and solidly  
soldered onto a single PCB without any wire connections.  
Magnetic feedback ensures maximum reliability and  
repeatability in the control loop over all operating condi-  
tions. Careful considerations of possible thermal stresses  
ensure the absence of hot spots providing long life in envi-  
ronments where temperature cycles are a reality. The ther-  
mal design allows operation at full load up to an ambient  
temperature of 71°C in free air without using any potting  
material. For extremely high vibration environments the  
case has holes for screw mounting.  
Providing two wide input voltage ranges, 14...36 V DC and  
36...75 V DC, the units are available with single and electri-  
cally isolated double outputs allowing the configuration of  
output voltages from 3.3 up to 48 V DC externally adjust-  
able, with flexible load distribution on double output units.  
An inhibit input allows remote converter on/off.  
Features include efficient input and output filtering with un-  
surpassed transient and surge protection, low output ripple  
and noise, consistently high efficiency over the entire input  
voltage range, high reliability as well as excellent dynamic  
response to load and line changes.  
The converters provide supplementary insulation with  
SELV outputs as e.g. required in battery supported systems  
where the bus voltage may exceed the SELV limit of  
Optionally the IMS 7 series is available with the industrial  
C pinout or with an SMD pinout.  
Table of Contents  
Page  
Page  
Summary.......................................................................... 1  
Type Survey and Key Data .............................................. 2  
Type Key .......................................................................... 2  
Functional Description...................................................... 3  
Electrical Input Data ......................................................... 4  
Electrical Output Data ...................................................... 6  
Auxiliary Functions ........................................................... 8  
Electromagnetic Compatibility (EMC) ............................ 10  
Immunity to Environmental Conditions........................... 11  
Mechanical Data ............................................................ 12  
Safety and Installation Instructions ................................ 13  
Description of Options.................................................... 15  
Accessories .................................................................... 15  
Edition 5/9.99  
1/15  
MELCHER  
The Power Partners.  
IMS 7-Series  
DC-DC Converters <40Watt  
Industrial Environment  
Type Survey and Key Data  
Table 1: Type survey  
Output 1  
Output 2  
Output  
power  
Po nom [W]  
Input Voltage Range and Efficiency  
Options  
1
1
2
Uo nom  
Io nom  
[A]  
Uo nom  
Io nom  
[A]  
Ui min...Ui max  
htyp  
Ui min...Ui max  
htyp  
[%]  
[V DC]  
[V DC]  
14...36 V DC  
[%]  
36...75 V DC  
3.3  
5.1  
1.5  
1.2  
-
-
-
-
5
6.1  
24 IMS 7-03-7  
24 IMS 7-05-7  
79  
81  
48 IMS 7-03-7  
48 IMS 7-05-7  
79  
82  
-9, M, C  
-9, M, C  
5
0.7  
0.3  
0.24  
0.15  
5
0.7  
0.3  
0.24  
0.15  
7
24 IMS 7-05-05-7  
24 IMS 7-12-12-7  
24 IMS 7-15-15-7  
24 IMS 7-24-24-7  
83  
84  
84  
84  
48 IMS 7-05-05-7  
48 IMS 7-12-12-7  
48 IMS 7-15-15-7  
48 IMS 7-24-24-7  
83  
84  
84  
84  
-9, M, C  
-9, M, C  
-9, M, C  
-9, M  
12  
15  
24  
12  
15  
24  
7.2  
7.2  
7.2  
1 Flexible load distribution on double outputs possible.  
2 See: Description of Options  
Type Key  
24 IMS 7 - 05 - 05 -7 M C  
Input voltage range Ui  
14...36 V DC .............................................. 24  
36...75 V DC .............................................. 48  
Series ........................................................................IMS 7  
Output voltage type for output 1 ............. 03, 05, 12, 15, 24  
Dash: Designates double output unit with two indepen-  
dent galvanically isolated outputs ................. -  
1
Output voltage type for output 2 ................... 05, 12, 15, 24  
Operating ambient temperature range TA  
25...71°C .................................................. -7  
40...71°C (standard) ................................. -9  
2
Options:  
SMD version ............................................... M  
C-pinout ................................................ C, C2  
2 3  
1 Not applicable for option C.  
2 C-pinout excludes option M and vice versa.  
3 Configures the 2 outputs either to ± connection or to one strong single output.  
For delivery lead times contact factory. Some types require a minimum order quantity.  
Examples: 48 IMS 7-05-05-7M: DC-DC converter, input voltage range 36...75 V, 2 galvanically isolated outputs each pro-  
viding 5 V, 700 mA, surface mount version.  
24 IMS 7-0505-7C: DC-DC converter, input voltage range 14...36 V, C-pinout with outputs ±5 V, 700 mA.  
24 IMS 7-15-7C2: DC-DC converter, input voltage range 14...36 V, C-pinout with one output 15 V, 480 mA.  
Edition 5/9.99  
MELCHER  
2/15  
The Power Partners.  
Industrial Environment  
DC-DC Converters <40Watt  
IMS 7 Series  
Functional Description  
The IMS 7 DC-DC modules are feedback controlled flyback  
converters using current mode PWM (Pulse Width Modula-  
tion).  
In the case of the double output units the output voltage is  
monitored by a separate transformer winding close to the  
secondary windings and fed back to the control circuit. The  
R-input is referenced to the primary side and allows pro-  
gramming of the output voltage in the range 100 to 105% of  
Uo nom by an external resistor or within 75 to 105% of Uo nom  
using an external voltage source.  
In the case of the single output units the output is directly  
monitored and fed back to the primary control circuit via a  
pulse transformer, resulting in tight regulation of the output  
voltage. The R input is referenced to the secondary side  
and allows for programming of the output voltages in the  
range 75 to 105% of Uo nom using either an external resistor  
or an external voltage source.  
Current limitation is provided by the primary circuit, thus  
limiting the total output current (Io nom for the single and  
Io1 nom + Io2 nom for the double output types).  
The inhibit input allows remote converter shutdown.  
03026  
03025  
1
3
11  
Vi+  
Vo+  
1
11  
Vi+  
Vo1  
PWM  
(Trim)  
R
4
3
i
10  
13  
Vo1  
Vo2  
10  
12  
PWM  
10 nF  
Vo–  
i
2 × 2200 pF  
1500 V  
2
4
Vi–  
2
12  
Vi–  
Vo2  
13  
14  
R
14 n.c.  
n.c.  
n.c.  
2 × 2200 pF, 1500 V  
Fig. 1  
Block diagram, single output types, standard pinout  
Fig. 2  
Block diagram, double output types, standard pinout  
03040  
03039  
1
3
Vi+  
Vo+  
1
Vi+  
3
Vo+  
Go  
PWM  
10  
5
Vo–  
PWM  
10 nF  
2 × 2200 pF  
1500 V  
2
Vi–  
2
5
Vi–  
Vo –  
2 × 2200 pF, 1500 V  
Fig. 3  
Fig. 4  
Block diagram, single output types, C pinout  
Block diagram, dual output types, C pinout  
Edition 5/9.99  
3/15  
MELCHER  
The Power Partners.  
IMS 7-Series  
DC-DC Converters <40Watt  
Industrial Environment  
Electrical Input Data  
General conditions:  
TA = 25°C, unless TC is specified.  
Connector pins i and Viinterconnected.  
R input not connected.  
Table 2: Input Data  
Input  
24 IMS  
48 IMS  
Characteristics  
Conditions  
min  
14  
typ  
max  
36  
min  
36  
typ  
max  
75  
Unit  
Ui  
Input voltage range 1  
TA min...TAmax  
Io = 0...Io nom  
V DC  
Ui nom  
Ui sur  
Input voltage (nominal)  
24  
48  
Repetitive surge  
voltage  
Abs. max input (3 s)  
50  
100  
tstart up  
Converter 2  
start-up time  
switch on  
inh. release  
Worst case condition at  
Ui min and full load  
0.25  
0.5  
0.1  
0.25  
0.5  
0.1  
s
trise  
Rise time 2  
Ui nom, Io = Io nom  
resistive load  
5
12  
5
ms  
capacitive load  
Io = 0, Ui min...Ui max  
for surge calculation  
Converter operating  
Converter inhibited  
Converter operating  
Converter inhibited  
Ui min...Ui max  
12  
6
Iio  
No load input current  
Input capacitance  
Inhibit voltage  
12  
24  
12  
mA  
µF  
Ci  
Uih  
0.8  
0.5  
10...0.8  
10 ...0.8  
V DC  
open, 2.4...Ui max  
open, 2.4...Ui max  
Iih  
Inhibit current  
0.5  
0.5  
mA  
1
1
Ii ih  
Input current  
3.0  
3.0  
if unit inhibited  
Iinr p  
fs  
Peak inrush current 4  
Switching frequency  
Reflected ripple current  
Ui = Ui nom  
4.0  
3.9  
A
Ui min...Ui max, Io = 0...Io nom  
Io = 0...Io nom  
approx. 330  
approx. 330  
kHz  
mApp  
Ii rr  
40  
30  
Ui RFI  
Input RFI level  
EN 55022 3  
B
B
conducted and radiated  
1 Ui min will not be as stated if Uo is increased above Uo nom by use of the R input pin. If the output voltage is set to a higher value, Ui min  
will be proportionally increased.  
2 Measured with a resistive or max. admissible capacitive load. (See fig.: Converter start-up and rise time).  
3 Measured with a lead lenght of 0.1 m, leads twisted. Double output units with both outputs in parallel.  
4 Source impedance according to prETS 300132-2, version 4.3.  
5 The level of the switching frequency band varies with the output voltage configuration. (See also fig.: Switching frequency versus  
input voltage and load.)  
04008  
Uo  
trise  
Uo nom  
t
tstart up  
Fig. 5  
Converter start-up and rise time  
Edition 5/9.99  
MELCHER  
4/15  
The Power Partners.  
Industrial Environment  
DC-DC Converters <40Watt  
IMS 7 Series  
Input Transient Voltage Protection  
Reverse Polarity Protection at Input  
In many applications transient voltages on the input of the  
converter are always possible. These may be caused for ex-  
ample be short circuits between Vi+ and Viwhere the net-  
work inductance may cause high energy pulses.  
The suppressor diode on the input also provides for reverse  
polarity protection by conducting current in the reverse di-  
rection, thus protecting the unit. An external fuse is required  
to limit this current:  
For 24 IMS 7 a fast 2 A (F2A) fuse is recommended.  
For 48 IMS 7 a fast 1 A (F1A) fuse is recommended.  
In order to protect the converter a large transient voltage  
supressor has been fitted to the input of the IMS 7 types.  
Specifications as per table below.  
Inrush Current  
Table 3: Built-in transient voltage suppressor  
The inrush current has been kept as low as possible by  
choosing a very small input capacitance. A series resistor  
may be inserted in the input line to limit this current further.  
Type  
Breakdown  
Voltage  
Peak Power  
at 1 ms  
PP  
Peak Pulse  
Current  
IPP  
VBR nom  
1 A/Div.  
4
24 IMS 7  
48 IMS 7  
53 V  
600 W  
600 W  
7.7 A  
4.1 A  
04030  
100 V  
3
2
If transients generating currents above the peak pulse cur-  
rent Ipp are possible then an external limiting network such  
as the circuit recommended for IEC 801-5, level 2 compli-  
ance is necessary.  
1
0
To achieve IEC/EN 61000-4-5, level 2 compliance an addi-  
tional inductor and capacitor should be provided externally  
as shown in the figure below. The components should have  
similar characteristics as listed in table 9.  
10 µs/Div.  
To withstand the 150 V transient according to 19 Pfl 1, appli-  
cable for 48 IMS 7 types, the same external circuitry with  
similar components as for IEC/EN 61000-4-5, level 2 com-  
pliance can be used.  
Fig. 8  
Typical inrush current at Ui nom, Po nom versus time  
(48 IMS 7) measured according to prETS 300132-2 (Ver-  
sion 4.3)  
04043  
L
V+  
Vi+  
i
+
Module  
C
V–  
Vi–  
Fig. 6  
Example for external circuitry to comply with  
IEC/EN 61000-4-5, level 2.  
Table 4: Components for external circuitry to comply with  
IEC 801-5  
Circuit Ref.  
24 IMS 7  
48 IMS 7  
L
330 µH, 0.42 , 0.6 A  
330 µH, 0.42 , 0.6 A  
TDK TSL1110-331KR55 TDK TSL1110-331KR55  
C
68 µ, 63 V, 85°C  
68 µF, 100 V, 85°C  
04029  
10.5  
5
0.7  
Fig. 7  
Dimensions for inductor L  
Edition 5/9.99  
5/15  
MELCHER  
The Power Partners.  
IMS 7-Series  
DC-DC Converters <40Watt  
Industrial Environment  
Electrical Output Data  
General conditions:  
TA = 25°C, unless TC is specified.  
Connector pins i (inhibit) and Viinterconnected.  
R input not connected.  
Table 5a: Output data for single output units  
Output  
Uo nom  
3.3 V  
5.1 V  
Characteristics  
Uo1 Output voltage  
Io nom Output current  
Conditions  
Ui nom  
min typ max  
min typ max  
Unit  
VDC  
A
3.26  
3.34  
5.05  
5.15  
Ui min...Ui max  
1.5  
1.2  
Io L  
Current limit 2  
Ui nom, TC = 25°C  
3.0  
2.4  
DUo U Line and load regulation  
Ui min...Ui max  
Io = (0.05...1) Io nom  
±1  
±1  
%
5
uo1  
Output voltage noise  
Ui min...Ui max  
70  
70  
mVpp  
Io = Io nom  
6
20 40  
130  
20 40  
130  
Uo clp Output overvoltage  
limitation 7  
115  
115  
%
Co ext Admissible  
capacitive load  
2500  
2000  
µF  
uo d Dynamic Voltage deviat. Ui nom  
±250  
±250  
mV  
ms  
1
load  
Io nom / Io nom  
2
td  
Recovery time  
1
1
regulat.  
aUo Temperature coefficitent  
DUo/D TC (TC min...TC max  
Ui min...Ui max  
Io = 0...Io max  
±0.02  
±0.02  
%/K  
)
Table 5b: Output data for double output units  
Output  
Uo nom  
2 × 5 V  
2 × 12 V  
2 × 15 V  
min typ max  
2 × 24 V  
Characteristics  
Conditions  
min typ max  
min typ max  
min typ max  
Unit  
Uo1 Output voltage  
Uo2  
Ui nom  
Io = 0.5 Io nom  
4.92  
4.92  
5.08 11.82  
5.08 11.82  
12.18 14.78  
12.18 14.78  
15.22 23.64  
15.22 23.64  
24.36 VDC  
24.36  
Io nom Output current 1  
Ui min...Ui max  
2 × 0.7  
2 × 0.3  
2 × 0.24  
2 × 0.15  
A
Io L  
Current limit 2, 3  
Ui nom, TC = 25°C  
2.8  
1.2  
1.1  
0.6  
DUo U Line regulation  
Ui min...Ui max  
Io nom  
±1  
±1  
±1  
±1  
%
DUo l Load regulation 4  
uo1, 2 Output voltage noise  
Ui nom  
Io = (0,1...1) Io nom  
±3  
±3  
±3  
±3  
5
Ui min...Ui max  
Io = Io nom  
80  
20 40  
130  
120  
150  
30 60  
130  
240 mVpp  
50 100  
130  
6
25 50  
130  
Uo clp Output overvoltage  
limitation 7  
Minimum load 1% 115  
115  
115  
115  
%
Co ext Admissible  
capacitive load 3  
2000  
300  
200  
100  
µF  
uo d Dynamic Voltage deviat. Ui nom  
±150  
±330  
±350  
±600  
mV  
ms  
load  
I
o nom 1/  
Io nom  
2
td  
Recovery time  
1
1
1
1
regulat.  
aUo Temperature coefficitent  
DUo/DTC (TC min...TC max  
Ui min...Ui max  
Io = 0...Io max  
±0.02  
±0.02  
±0.02  
±0.02  
%/K  
)
1 Each output is capable of delivering the full output power, Po nom according to table Type survey.  
2 The current limit is primary side controlled.  
3 Measured with both outputs connected in parallel.  
4 Conditions for specified output. Other output loaded with constant current Io = 0.5 Io nom  
5 BW = 20 MHz  
6 Measured with a probe according to EN 61204.  
7 The overvoltage protection is not tracking with the R control.  
.
Edition 5/9.99  
MELCHER  
6/15  
The Power Partners.  
Industrial Environment  
DC-DC Converters <40Watt  
IMS 7 Series  
Short Circuit Behaviour  
Connection in Series or in Parallel  
Connection in series:  
The outputs of single or double output units can be con-  
nected in series without any precautions, taking into consid-  
eration that the highest output voltage should remain below  
60 V for SELV operation.  
The current limit characteristic shuts down the converter  
whenever a short circuit is applied to its output. It acts self-  
protecting and automatically recovers after removal of the  
overload condition (hiccup mode).  
Thermal Considerations  
Connection in parallel:  
If a converter, mounted on a PCB, is located in free, quasi-  
stationary air (convection cooling) at the indicated maxi-  
mum ambient temperature TA max (see table: Temperature  
specifications) and is operated at its nominal input voltage  
and output power, the case temperature TC measured at the  
Measuring point of case temperature TC (see: Mechanical  
Data) will approach the indicated value TC max after the  
warm-up phase. However, the relationship between TA and  
TC depends heavily on the conditions of operation and inte-  
gration into a system. The thermal conditions are influenced  
by input voltage, output current, airflow, temperature of sur-  
rounding components and surfaces and the properties of  
the printed circuit board. TA max is therefore only an indica-  
tive value and under practical operating conditions, the am-  
bient temperature TA may be higher or lower than this value.  
The outputs of one or several double output units with equal  
nominal voltage can be connected in parallel. Approximate  
current sharing between 2 or several units is ensured by  
their load dependent output characteristic.  
Output Overvoltage Protection  
The outputs of single output units and -05-05- types are  
protected against overvoltages by a second control loop. In  
the event of an overvoltage on the output the unit will shut-  
down and attempt to restart approximately every 0.4 sec-  
onds. Double output units (with exception of the -05-05-  
types) are protected against overvoltages by a Zener diode  
accross the second output. Under worst case conditions the  
Zener diode will short circuit. Since with double output units  
both outputs track each other the protection diode is only  
provided in one of the outputs. The main purpose of this fea-  
ture is to protect against possible overvoltages which could  
occur due to a failure in the feedback control circuit.The  
output overvoltage protection is not designed do withstand  
externally applied overvoltages.  
Caution: The case temperature TC measured at the  
Measuring point of case temperature TC (see: Mechani-  
cal Data) may under no circumstances exceed the speci-  
fied maximum value. The installer must ensure that un-  
der all operating conditions TC remains within the limits  
stated in the table: Temperature specifications.  
Typical Performance Curves  
Uo [V]  
Uo [V]  
05087  
05086  
13  
5.5  
12  
11  
10  
9
5.0  
4.5  
4.0  
3.5  
3.0  
8
7
Io total [A]  
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9  
0
0
0.2  
0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 Io [A]  
0.4  
Fig. 9  
Fig. 10  
Uo versus Io (typ) of single output units with Uo = 5.1 V.  
Uo versus Io (typ) of double output units, with both outputs  
in parallel.  
Uo1 [V]  
Uo1, Uo2 [V]  
05088  
13.5  
05039  
14  
13  
13.0  
12.5  
Io2 = 0.03 A  
Io2 = 0.3 A  
12  
11  
10  
Uo2  
Uo1  
12.0  
11.5  
11.0  
Io1  
Io1 nom  
[%]  
50  
75  
100  
125  
150  
0.03  
0.10  
0.15  
0.25  
0.35 Io1 [A]  
0
25  
0.05  
0.20  
Fig. 11  
o1 versus Io1 (typ) for various Io2 (2 × 12 V).  
Fig. 12  
U
Flexible load distribution on double outputs (2 × 12 V) with  
The cross load effect is negligible.  
load variation from 0...150% of Po1 nom on output 1. Output  
2 loaded with 25% of Po2 nom  
.
Edition 5/9.99  
7/15  
MELCHER  
The Power Partners.  
IMS 7-Series  
DC-DC Converters <40Watt  
Industrial Environment  
h [%]  
05041  
05052  
Uo [%]  
90  
overload short circuit condition  
switch-off  
Ui nom  
Ui max  
Ui min  
100  
70  
80  
70  
60  
50  
40  
8.5  
t [ms]  
60.5  
60.5  
Po  
Po nom  
[%]  
50  
100  
25  
75  
Fig. 13  
Fig. 14  
Overload switch-off (hiccup mode). Typical values.  
Frequency of pulses: 16.5 Hz, puls duration: 8.5 ms  
Efficiency versus input voltage and load. Typical values  
(48 IMS 7-12-12-7).  
Auxiliary Functions  
Inhibit Function  
Adjustable Output Voltage (R input)  
The output(s) of the converter may be enabled or disabled  
by means of a logic signal (TTL, CMOS, etc.) applied to the  
inhibit pin. No output voltage overshoot will occur when the  
unit is turned on. If the inhibit function is not required the  
inhibit pin should be connected to Vito enable the output  
(active low logic, fail safe).  
As a standard feature, the IMS 7 single and double output  
units offer adjustable output voltage(s) by using the control  
input R pin. If the R pin is left open circuit the output voltage  
is set to Uo nom. The output voltage is adjustable in the range  
75...105% of Uo nom.The circuit works for single and double  
output units in a different way. For output voltages Uo >  
Uo nom, the minimum input voltage Ui min (see: Electrical In-  
Converter operating:  
Converter inhibited  
or inhibit pin left open:  
10 V...0.8 V  
put Data) increases proportionally to Uo/Uo nom  
.
2.4 V...Ui max  
Single output units:  
06070  
The R input is referenced to the secondary side of the con-  
verter. Adjustment of the output voltage is possible by  
means of either an external resistor or a voltage source.  
Vi+  
a) Adjustment by means of an external resistor Rext1  
:
i
Depending upon the value of the required output voltage,  
the resistor shall be connected  
Vi–  
either: Between the R pin and Voto achieve an output  
voltage adjustment range of approximately  
Uo = 75...100% Uo nom. (85...100% for 3.3 V outputs)  
Fig. 15  
If the inhibit is not used the inhibit pin should be connected  
to Vi–  
Uo  
R
ext1 4 k• –––––––––  
Uo nom Uo  
or: Between the R pin and Vo+ to achieve an output volt-  
age range of approximately Uo = 100...105% Uo nom  
.
(Uo 2.5 V)  
2.5 V (Uo/Uo nom 1)  
R
ext2 4 k• –––––––––––––––––––  
Edition 5/9.99  
8/15  
MELCHER  
The Power Partners.  
Industrial Environment  
DC-DC Converters <40Watt  
IMS 7 Series  
a) Adjustment by means of an external resistor.  
b) Adjustment by means of an external voltage Uext be-  
tween Voand R pins.  
Programming of the output voltage by means of an exter-  
nal resistor Rext1 is possible within a limited range of  
100...105% of Uo nom. Rext1 should be connected between  
the R-pin and Vi. Connection of Rext1 to Vi+ may dam-  
age the converter. The following table indicates suitable  
resistor values for typical output voltages under nominal  
conditions (Ui nom, Io = 0.5 Io nom), with either paralleled  
outputs or equal load conditions on each output.  
The control voltage range is 1.87...2.62 V and allows for  
an adjustment in the range of approximately 75...105%.  
(85...105% for 3.3 V outputs)  
Uo 2.5 V  
Uo nom  
U
ext –––––––––  
Attempting to adjust the output below this range will  
cause the converter to shutdown (hiccup mode).  
Table 6: Rext1 for Uo > Uo nom  
approximate values (Ui nom, Io1, 2 = 0.5 Io1/2 nom  
;
Note: Applying an external control voltage >2.75 V may  
damage the converter.  
)
Uo [% Uo nom  
]
R
ext [k]  
06029  
105...108 (107 typically)  
0
Vi+  
Vo+  
R
105  
104  
103  
102  
101  
100  
1.5  
5.6  
12  
27  
68  
Rext2  
Uref 2.5 V  
4 kΩ  
+
control  
circuit  
Uext  
Rext1  
b) Adjustment by means of an external voltage source Uext  
.
Vo–  
Vi–  
For external output voltage programming in the range  
75...105% of Uo nom a (0...20 V) source Uext is required,  
connected to the R-pin and Vi.The table below indicates  
typical Uo versus Uext values under nominal conditions  
(Ui nom, Io = 0.5 Io nom), with either paralleled outputs or  
equal load conditions on each output. Applying a control  
voltage >20 V will set the converter into a hiccup mode.  
Direct paralleling of the R-pins of units connected in par-  
allel is feasible.  
Fig. 16  
Output voltage control for single output units by means of  
the R-input  
Double output units:  
The R input (Trim) is referenced to the primary side. The fig-  
ure below shows the circuit topology. Adjustment of the out-  
put voltage is possible by means of either an external resis-  
tor in the range of 100...105% of Uo nom, or an external volt-  
Table 7: Uext for Uo = 75...105% Uo nom  
;
typical values (Ui nom, Io1, 2 = 0.5 Io1/2 nom  
)
age source in the range of 75...105% of Uo nom  
.
Uo [% Uo nom  
]
Uext [V]  
06132  
105  
102  
95  
85  
75  
0
Vi+  
Vo1+  
Vo1–  
Vo2+  
1.6  
4.5  
9
R (Trim)  
+
13  
Control  
circuit  
Uext  
Rext  
Vi–  
Vo2–  
Fig. 17  
Output voltage control for double output units by means of  
the R input  
Edition 5/9.99  
9/15  
MELCHER  
The Power Partners.  
IMS 7-Series  
DC-DC Converters <40Watt  
Industrial Environment  
Electromagnetic Compatibility (EMC)  
which typically occur in many installations, but especially in  
battery driven mobile applications.  
A suppressor diode together with an input filter form an ef-  
fective protection against high input transient voltages  
Electromagnetic Immunity  
Table 8: Immunity type tests  
Phenomenon  
Standard 1  
Class  
Level  
Coupling  
mode 2  
Value  
applied  
Waveform  
Source  
Imped.  
Test  
procedure  
In  
oper. form.  
Per- 3  
Electrostatic  
discharge  
to case  
IEC/EN  
61000-4-2  
2
3
2
contact discharge 4000 Vp  
R pin open  
i pin connec. to Vi–  
1/50 ns  
330 Ω  
10 positive and  
10 negative  
discharges  
yes  
B
air discharge  
R pin open  
i pin connec. to Vi–  
8000 Vp  
3 V/m  
Electromagnetic IEC/EN  
field  
antenna  
AM 80%  
1 kHz  
261000 MHz  
yes  
yes  
A
B
61000-4-3  
ENV 50204  
PM, 50% duty  
cycle, 200 Hz  
resp. frequ.  
900 MHz  
Electrical fast  
transient/burst  
IEC/EN  
61000-4-4  
3
direct +i/i  
2000 Vp bursts of 5/50 ns 50 Ω  
5 kHz rep. rate  
1 min positive  
1 min negative  
transients per  
coupling mode  
transients with  
15 ms burst  
duration and a  
300 ms period  
Surge  
IEC/EN  
2
2
+i/i  
1000 Vp  
3 Vrms  
1.2/50 µs  
2 Ω  
5 pos. and 5 neg.  
impulses per  
coupling mode  
yes  
B
61000-4-5 5  
Conducted  
disturbancies  
IEC/EN  
61000-4-6  
+i/i  
+i/i  
AM modulated  
50 Ω  
0.15...80 MHz  
yes  
yes  
A
B
(130 dBµV) 80%, 1 kHz  
150 Ω  
Transient  
19 Pfl 1 4  
150 Vp 0.1/0.3 ms  
limited to  
<100 A  
3 positive  
1 Related and previous standards are referenced in Technical Information: Standards.  
3 A = normal operation, no deviation from specification, B = temporary deviation from specs. possibe.  
4 For 48 IMS 7 types (additional external components required). Not applicable for 24 IMS 7 types.  
2 i = input, o = output.  
5 External components required.  
Electromagnetic Emission  
Conducted RFI noise at input according to EN 55022  
Radiated RFI noise according to EN 55022.  
[dBµV/m]  
[dBµV]  
90  
07024  
07023  
40  
80  
35  
30  
25  
20  
EN 55022 A  
EN 55022 B  
70  
60  
EN 55022 B  
50  
40  
30  
20  
10  
0
15  
10  
0
[MHz]  
MHz  
Fig. 19  
Typical radio frequency-interference voltage at Ui nom  
Io nom, measured with an antenna (distance 10 m). Output  
leads 0.1 m, twisted (48 IMS-7-15-15-7).  
,
Fig. 18  
Typical disturbance voltage (quasi-peak) at the input ac-  
cording to CISPR 11/EN 55011 and CISPR 22/EN 55022  
measured at Ui nom and Io nom. Output leads 0.1 m, twisted.  
(48 IMS 7-15-15-7).  
Edition 5/9.99  
10/15  
MELCHER  
The Power Partners.  
Industrial Environment  
DC-DC Converters <40Watt  
IMS 7 Series  
Immunity to Environmental Conditions  
Table 9: Mechanical stress  
Test Method  
Standard  
Test Conditions  
Status  
Ca  
Ea  
Eb  
Fc  
Damp heat  
steady state  
IEC/DIN IEC 60068-2-3  
MIL-STD-810D section 507.2 Relative humidity:  
Duration:  
Temperature:  
40 ±2 °C  
%
56 days  
Unit not  
operating  
93 +2/-3  
Shock  
(half-sinusoidal)  
IEC/EN/DIN EN 60068-2-27  
MIL-STD-810D section 516.3 Bump duration:  
Number of bumps:  
Acceleration amplitude:  
50 gn = 490 m/s2  
11 ms  
18 (3 each direction)  
Unit  
operating  
Bump  
(half-sinusoidal)  
IEC/EN/DIN EN 60068-2-29  
MIL-STD-810D section 516.3 Bump duration:  
Number of bumps:  
Acceleration amplitude:  
25 gn = 245 m/s2  
11 ms  
6000 (1000 each direction)  
Unit  
operating  
Vibration  
(sinusoidal)  
IEC/EN/DIN EN 60068-2-6  
MIL-STD-810D section 514.3  
Acceleration amplitude:  
0.35 mm (10...60 Hz)  
5 gn = 49 m/s2 (60...2000 Hz) operating  
10...2000 Hz  
Unit  
Frequency (1 Oct/min):  
Test duration:  
7.5 h (2.5 h each axis)  
Kb  
Salt mist, cyclic  
(sodium chloride  
NaCl solution)  
IEC/EN/DIN IEC 60068-2-52  
Concentration:  
Duration:  
Storage:  
Storage duration:  
Number of cycles:  
5% (30°C)  
Unit not  
operating  
2 h per cycle  
40°C, 93% rel. humidity  
22 h per cycle  
3
Table 10: Temperature specifications, valid for air pressure of 800...1200 hPa (800...1200 mbar)  
Temperature  
Standard -7  
max  
Characteristics  
Conditions  
Operational 2  
min  
25  
25  
40  
Unit  
TA  
TC  
TS  
Ambient temperature 1  
71  
95  
°C  
Case temperature  
Storage temperature 1  
Non operational  
100  
1 MIL-STD-810D section 501.2 and 502.2  
2 See Thermal Considerations  
Table 11: MTBF  
MTBF  
Ground Benign  
Ground Fixed  
Ground Mobile  
MTBF acc. to MIL-HDBK-217F  
24 IMS 7-05-7  
TC = 40°C  
TC = 40°C  
TC = 70°C  
TC = 50°C  
1'671'000 h  
248'000 h  
83'800 h  
84'800 h  
48 IMS 7-15-15-7  
1'640'000 h  
214'000 h  
83'000 h  
77'000 h  
Edition 5/9.99  
11/15  
MELCHER  
The Power Partners.  
IMS 7-Series  
DC-DC Converters <40Watt  
Industrial Environment  
Mechanical Data  
Dimensions in mm. Tolerances ±0.3 mm unless otherwise indicated.  
European  
Projection  
09030  
50.8  
0.8 × 1.2 Pins  
1.6 PCB holes  
3.81  
14  
3.81  
3.81  
3.81  
3.81  
3.81  
Bottom view  
1
5.08  
5.08  
5.08  
3.81  
10  
4
PT 2.2 self tapping  
4.6  
3.81  
screws (2×),  
45.7  
Measuring point  
case temperature TC  
Fig. 20  
Case IMS 7 with standard soldering pins  
Weight: <20 g  
50.8  
09031  
0.8 × 1.2 Pins  
3.81  
3.81  
3.81  
3.81  
3.81  
14  
10  
Bottom view  
1
4
5.08  
5.08  
5.08  
3.81  
42.4  
Measuring point  
case temperature TC  
Fig. 21  
4.2  
Case IMS 7 with SMD pins (option M)  
Weight: <20 g  
50.8  
09032  
1 Pins  
35.5  
1.2 PCB holes  
1
15.2  
7
3
1
4
2
6
5
Measuring point  
case temperature TC  
Fig. 22  
Case IMS 7 with C pinout (option C) for double output units. (Pins 6 and 7 are not fitted.)  
With single output units pins 4, 6 and 7 are not fitted.  
Weight: <24 g  
Edition 5/9.99  
MELCHER  
12/15  
The Power Partners.  
Industrial Environment  
DC-DC Converters <40Watt  
IMS 7 Series  
Safety and Installation Instructions  
Table 13: Pin allocation, standard pinout  
Installation Instruction  
Installation of the DC-DC converters must strictly follow the  
national safety regulations in compliance with the enclo-  
sure, mounting, creepage, clearance, casualty, markings  
and segregation requirements of the end-use application.  
Pin  
1
Single output units  
Double output units  
Vi+  
Vi–  
i
Vi+  
Vi–  
2
3
i
Connection to the system shall be made via a printed circuit  
board according to: Mechanical Data.  
4
n.c.  
Vo–  
Vo+  
Vo–  
R
R (Trim)  
Vo1–  
Vo1+  
Vo2–  
Vo2+  
n.c.  
The units should be connected to a secondary circuit.  
10  
11  
12  
13  
14  
Check for hazardous voltages before altering any connec-  
tions.  
Do not open the module.  
Ensure that a unit failure (e.g. by an internal short-circuit)  
does not result in a hazardous condition. See also: Safety  
of operator accessible output circuit.  
n.c.  
10011  
14  
13  
12  
11  
10  
Input Fuse  
1
To prevent excessive current flowing through the input sup-  
ply line in case of a short-circuit across the converter input  
an external fuse should be installed in a non earthed input  
supply line. We recommend a fast acting fuse F2A for  
24 IMS 7 types and F1A for 48 IMS 7 types.  
2
3
4
Bottom view  
Fig. 23  
Pin allocation standard pinout  
Cleaning Agents  
Table 14: Pin allocation for C-pinout (option C)  
In order to avoid possible damage, any penetration of  
cleaning fluids has to be prevented, since the power sup-  
plies are not hermetically sealed.  
Pin  
1
Single output units  
Dual output units  
Vi+  
Vi–  
Vi+  
Vi–  
Vo+  
Go  
Standards and approvals  
2
All DC-DC converters are UL recognized according to  
UL 1950, UL recognized for Canada to CAN/CSA C22.2  
No. 950-95 and LGA approved to IEC/EN 60950 standards.  
3
Vo+  
4
no pin  
Vo–  
5
Vo–  
The units have been evaluated for:  
Building in  
10012  
Supplementary insulation input to output, based on their  
maximum input voltage  
The use in a pollution degree 2 environment  
Connecting the input to a secondary circuit which is sub-  
ject to a maximum transient rating of 1500 V  
3
4
5
1
2
The DC-DC converters are subject to manufacturing sur-  
veillance in accordance with the above mentioned UL,  
CSA, EN and ISO 9001 standards.  
Fig. 24  
Pin allocation C pinout, bottom view  
Protection Degree  
Isolation  
The protection degree of the DC-DC converters is IP 30.  
The electric strength test is performed as factory test in ac-  
cordance with IEC/EN 60950 and UL 1950 and should not  
be repeated in the field. Melcher will not honour any guar-  
antee claims resulting from electric strength field tests.  
Safety of operator accessible output circuit  
If the output circuit of a DC-DC converter is operator acces-  
sible, it shall be an SELV circuit according to IEC/EN 60950  
related safety standards  
Table 12: Electric strength test voltages, clearance and  
creepage distances  
The insulation concept table below shows some possible  
installation configurations, compliance with which causes  
the output circuit of the DC-DC converter to be an SELV cir-  
cuit according to IEC/EN 60950 up to a configured output  
voltage (sum of nominal voltages if in series or +/configu-  
ration) of 42 V.  
Characteristic  
I/O  
1.2  
O/O  
0.1  
0.15  
-
Unit  
kVrms  
kV DC  
nF  
Electric strength  
test voltage 1 s  
1.5  
Coupling capacitance  
1.2  
>100  
Isulation resistance  
at 500 V DC  
-
MΩ  
However, it is the sole responsibility of the installer to en-  
sure the compliance with the relevant and applicable safety  
regulations. More information is given in: Technical Infor-  
mation: Safety.  
Partial discharge  
extinction voltage  
Consult  
factory  
-
kV  
Edition 5/9.99  
13/15  
MELCHER  
The Power Partners.  
IMS 7-Series  
DC-DC Converters <40Watt  
Industrial Environment  
Table 15: Insulation concept leading to an SELV output circuit  
Conditions Front end  
DC-DC converter  
Result  
Supply  
voltage  
Minimum required grade  
of isolation, to be provided DC output status of the front end  
by the AC-DC front end,  
including mains supplied  
battery charger  
Maximum Minimum required safety  
Measures to achieve the  
specified safety status of the  
output circuit  
Safety status of  
the DC-DC  
converter output  
circuit  
voltage  
output circuit  
from the  
front end 1  
Mains  
250 V AC  
Basic  
60 V  
Earthed SELV circuit 2  
ELV circuit  
Operational insulation, pro-  
vided by the DC-DC converter  
SELV circuit  
Input fuse 3 output suppressor Earthed SELV  
diode(s) 4, and earthed  
output circuit(s) 2  
circuit  
>60 V  
60 V  
>60 V  
Hazardous voltage  
secondary circuit  
Double or reinforced  
SELV circuit  
Operational insulation, pro-  
vided by the DC-DC converter  
SELV circuit  
TNV-2 circuit  
Supplementary insulation,  
based on the maximum input  
voltage, provided by the  
DC-DC converter  
Double or reinforced insu-  
lated unearthed hazardous  
voltage secondary circuit 5  
1 The front end output voltage should match the specified input voltage range of the DC-DC converter.  
2 The earth connection has to be provided by the installer according to the relevant safety standard, e.g. IEC/EN 60950.  
3 The installer shall provide an approved fuse (type with the lowest rating suitable for the application) in a non-earthed input line directly  
at the input of the DC-DC converter (see fig. Schematic safety concept). For ULs purpose, the fuse needs to be UL-listed. See also  
Input Fuse.  
4 Each suppressor diode should be dimensioned in such a way, that in the case of an insulation fault the diode is able to limit the output  
voltage to SELV (<60 V) until the input fuse blows (see fig. Schematic safety concept).  
5 Has to be insulated from earth by basic insulation according to the relevant safety standard, based on the maximum output voltage  
from the front end.  
10004  
Fuse  
+
~
Mains  
Suppressor  
diode  
AC-DC  
front  
DC-DC  
con-  
Battery  
SELV  
end  
verter  
~
Earth  
connection  
Earth  
connection  
Fig. 25  
Schematic safety concept. Use fuse, suppressor diode  
and earth connection as per table Safety concept leading  
to an SELV output circuit.  
Edition 5/9.99  
14/15  
MELCHER  
The Power Partners.  
Industrial Environment  
DC-DC Converters <40Watt  
IMS 7 Series  
Description of Options  
Table 16: Survey of options  
Option  
-9  
Function  
Characteristics  
Operational temperature range TA = 40...71°C  
Surface mount version, SMD  
C-pinout  
Extended temperature range  
Excludes option C.  
M
C, C2  
Excludes option M as well as galvanic isolation between output 1  
and 2 of double output units. Not available for 70/110 IMX 7 types.  
Option -9  
Option C2  
Temperature range 40...71°C. The modules will provide  
full output power with free air convection cooling.  
The C2-pinout configures the electrically isolated double  
outputs to one strong single output.  
Option C  
Option C and C2 exclude option M, the inhibit function as  
well as the R-function.  
The C-pinout configures the electrically isolated double out-  
puts to the "industrial pinout" Vo1+, Vo2with common  
ground Go. With the C-pinout the converter height is in-  
creased by the adapter PCB (see also: Mechanical Data).  
Option M  
Surface mount version.  
09119  
Note: Precautions should be taken when reflow soldering  
the SMD version, option M. The reflow soldering instruc-  
tions below should be strictly adhered to. An inadequate  
soldering process may permanently damage the converter  
or degrade its performance and Melcher will not honour any  
guarantee/warranty claims resulting from damage caused  
by ignoring the soldering instructions.  
4
Top view  
50  
Infrared soldering is not permitted.  
The surface mountable version of this product is assem-  
bled with high melting point solder (227°C) to ensure that  
the solder joints of of the internal components do not de-  
grade in the end users SMD soldering process.  
Fig. 27  
Proposed solder lands  
This product is only specified for "Forced Convection  
Reflow Soldering" (Hot Air). Any conventional soldering  
profile is acceptable provided that the restriction curve be-  
low is not exceeded at any time during the reflow process.  
Tpeak [°C]  
11051  
240  
235  
230  
225  
220  
215  
210  
t [s]  
205  
50  
0
20  
30  
40  
10  
Fig. 26  
Forced convection reflow soldering restriction curve  
measured on pin 2  
Accessories  
Mounting supports for chassis and DIN-rail mounting.  
Edition 5/9.99  
15/15  
MELCHER  
The Power Partners.  

相关型号:

48IMS7-15-15-7XC

DC-DC Regulated Power Supply Module, 2 Output, 7W, Hybrid, 2 X 1 INCH, PACKAGE-5
BEL

48IMS7-15-15-7XM

DC-DC Regulated Power Supply Module, 2 Output, 7W, Hybrid
BEL

48IMS7-15-15-9

7 Watt DC-DC Converters
POWER-ONE

48IMS7-15-15-9L

DC-DC Regulated Power Supply Module, 2 Output, 7W, Hybrid,
BEL

48IMS7-15-15-9M

DC-DC Regulated Power Supply Module, 2 Output, 7W, Hybrid, 2 INCH X 1.600 INCH, 10.50 MM HEIGHT, PACKAGE-9
BEL

48IMS7-15-15-9ZG

DC-DC Regulated Power Supply Module, 2 Output, 7W, Hybrid, ROHS COMPLIANT PACKAGE-14
BEL

48IMS7-15-9C

7 Watt DC-DC Converters
POWER-ONE

48IMS7-15-9C2L

DC-DC Regulated Power Supply Module, 1 Output, 7.2W, Hybrid,
BEL

48IMS7-15-9CG

DC-DC Regulated Power Supply Module, 7.2W,
BEL

48IMS7-15-9CZ

DC-DC Regulated Power Supply Module, 7.2W,
BEL

48IMS7-15-9CZG

DC-DC Regulated Power Supply Module, 1 Output, 7W, Hybrid, ROHS COMPLIANT PACKAGE-14
BEL

48IMS7-24-24-7X-G

DC-DC Regulated Power Supply Module, 2 Output, 7W, Hybrid, 2 X 1 INCH, 10.50 MM HEIGHT, PACKAGE-9
BEL