5ICR6-12-TC [BEL]
DC-DC Regulated Power Supply Module, 1 Output, 6W, Hybrid, 2 X 2 INCH, 10.50 MM HEIGHT, METAL PACKAGE-4;型号: | 5ICR6-12-TC |
厂家: | BEL FUSE INC. |
描述: | DC-DC Regulated Power Supply Module, 1 Output, 6W, Hybrid, 2 X 2 INCH, 10.50 MM HEIGHT, METAL PACKAGE-4 |
文件: | 总6页 (文件大小:124K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Industrial Environment
DC-DC Converters <40 W
6 Watt-Family
IBEK DC-DC Converters
6 Watt-Family
Input to output isolation test voltage 500 V
rms
Single output of 5V DC, 5 W
Single and dual output of 12V DC & 15 V DC, 6W
Input voltages of 5, 12, 15, 24, 28 and 48 V DC
• Efficient Pi input filter
• Outputs equipped with linear voltage regulation
• High reliability
• Optimal dynamic response
• Continuous no-load and short-circuit proof
• Operating ambient temperature range up to
–40...85°C (optional)
• Case height only 10.5 mm
Table of Contents
Page
Description ................................................................6 - 43
Type Survey .............................................................. 6 - 44
Safety Instructions..................................................... 6 - 45
Immunity to Environmental Conditions...................... 6 - 45
Electrical Input and Output Data ............................... 6 - 46
Installation Instructions.............................................. 6 - 47
Block Diagrams ......................................................... 6 - 47
Mechanical Data ....................................................... 6 - 48
Type Key and Product Marking ................................. 6 - 48
Description
The DC-DC converters have been developed as a re-
sponse to the increasing need for decentralised power sup-
ply systems. They are especially suitable for powering me-
dium loads on PCBs and for realising redundant systems.
The DC-DC converters feature high efficiency, low output
ripple, low module height, high quality and reliability. To
minimise feedback effects in the supply system, the mod-
ules are equipped with an efficient low-pass Pi input filter.
All modules are manufactured according to ISO 9001.
Case: 2"× 2" metal, black anodized, self cooling (free air
convection).
Edition 2/96 - © Melcher AG
6 - 43
MELCHER
The Power Partners.
6 Watt-Family
DC-DC Converters <40 W
Industrial Environment
Type Survey
General Condition: TA = 25°C
Table 1: Type survey
Output
Input
Typ. no load
Efficiency Group 1 Type 2
Pin-
Option
Uo nom
[V DC]
Io nom
[mA]
Ui nom
[V DC]
InputCurrent
(Ui nom, Io = 0) [mA]
η (typ.)
[%]
Config.
5
12
15
1000
500
400
5
32
46
52
68
72
72
01
5 ICR 5-05-T..
5 ICR 6-12-T..
5 ICR 6-15-T..
C, B
S
±12
±15
±250
±200
125
150
68
70
02
01
5 ICR 6-1212-T..
5 ICR 6-1515-T..
5
12
15
1000
500
400
12
20
25
30
70
75
75
12 ICR 5-05-T..
12 ICR 6-12-T..
12 ICR 6-15-T..
±12
±15
±250
±200
60
63
72
73
02
01
12 ICR 6-1212-T..
12 ICR 6-1515-T..
5
12
15
1000
500
400
15
24
18
19
20
72
75
75
15 ICR 5-05-T..
15 ICR 6-12-T..
15 ICR 6-15-T..
5
12
15
1000
500
400
18
19
20
72
76
76
24 ICR 5-05-T..
24 ICR 6-12-T..
24 ICR 6-15-T..
±12
±15
±250
±200
37
39
74
75
02
01
24 ICR 6-1212-T..
24 ICR 6-1515-T..
5
12
15
1000
500
400
28
48
18
19
20
72
76
76
28 ICR 5-05-T..
28 ICR 6-12-T..
28 ICR 6-15-T..
±12
±15
±250
±200
34
36
75
75
02
01
28 ICR 6-1212-T..
28 ICR 6-1515-T..
5
12
15
1000
500
400
12
13
14
70
72
72
48 ICR 5-05-T..
48 ICR 6-12-T..
48 ICR 6-15-T..
±12
±15
±250
±200
28
30
73
73
02
48 ICR 6-1212-T..
48 ICR 6-1515-T..
1
2
See "Block Diagrams"
Pin configuration should be added to the type designation (e.g. 5 ICR 5-05-TC)
6 - 44
Edition 2/96 - © Melcher AG
MELCHER
The Power Partners.
Industrial Environment
DC-DC Converters <40 W
6 Watt-Family
Safety Instructions
If the output circuit of a DC-DC converter is operator-acces-
sible according to the IEC 950 related safety standards, it
shall be an SELV circuit (Safety Extra Low Voltage circuit,
i.e. a circuit, separated from mains by at least basic insula-
tion, that is so designed and protected that under normal
and single fault conditions, the voltage between any two
conductors and between any conductor and earth does not
exceed 60 V DC).
In the following section an interpretation is provided of the
IEC 950 safety standard with respect to the safety status of
the output circuit. However, it is the sole responsibility of the
installer or user to assure the compliance with the relevant
and applicable safety standards.
If the following table is observed, the output of any DC-DC
converter is considered to be an SELV circuit up to a nomi-
nal output voltage of 30 V (2 x 15 V in series).
Table 2: Insulation concept for SELV circuits
Nominal Minimum required grade Maximum Minimum required
Minimum required grade of
isolation between the input
Resulting safety
status of the
mains
of isolation, to be
output
safety status of the
supply
provided by the AC-DC
voltage
front end output circuit
and the output of the DC-DC DC-DC converter
voltage front end, including mains from the
converter, provided by
the converter
output circuit
(AC)
supplied battery charger front end
≤250 V
Basic
≤60 V
≤65 V
Earthed SELV circuit 1
Operational
Operational
SELV circuit
Unearthed hazardous
voltage secondary circuit 2
Earthed SELV
circuit 1
Double or reinforced
≤60 V
≤65 V
SELV circuit
Operational
SELV circuit
Double or reinforced insu- Operational
lated unearthed hazardous
voltage secondary circuit,
supplying an SELV circuit 3
1 The earth connection has to be provided by the installer according to the relevant safety standard, e.g. IEC 950.
2 Has to be insulated from earth by at least basic insulation according to the relevant safety standard, based on the maximum input
voltage of the DC-DC converter.
3 Has to be insulated from earth by double or reinforced insulation according to the relevant safety standard, based on the maximum in-
put voltage of the DC-DC converter.
Immunity to Environmental Conditions
Thermal Considerations
Table 3: Temp. specification values given are valid for air pressures in the range 800...1200 hPa (800...1200 mbar)
Characteristics
Conditions
Standard -T
Option -S 1
Unit
min
max
71
min
max
85
TA
TC
TS
Ambient temperature
Ui min...Ui max
Io = 0...Io nom
–25
–25
–55
–40
–40
–55
°C
Case temperature
95
105
105
Storage temperature
not operational
105
1 ICR 6: Linear derating of the output power from 6 to 5 watts for TA = 71°C to 85°C.
The case temperature TC must not exceed the maximum value. In applications with limited air circulation, additional meas-
ures must be taken (either larger spacing or a fan) to avoid case temperatures higher than TC max
!
Table 4: MTBF
Values at specified
Case Temperature
Modules Types
Ground Benign
40°C
Ground Fixed
40°C 70°C
Ground Mobile
40°C 70°C
Unit
MTBF according to
MIL-HDBK-217F
Single output
Double output
2'150'000
1'850'000
570'000 270'000
510'000 250'000
190'000 90'000
150'000 70'000
h
Edition 2/96 - © Melcher AG
6 - 45
MELCHER
The Power Partners.
6 Watt-Family
DC-DC Converters <40 W
Industrial Environment
Electrical Input and Output Data
General Conditions: TA = 25°C
Table 5: Input Data
Input
5 V
12 V
15 V
24 V
28 V
48 V
Characteristics
Conditions
Unit
V
Ui
Input voltage range
min DC
max
4.40
6.50
10.56
15.60
13.20
19.50
21.12
31.20
24.64
36.40
42.24
62.40
at 60% load
Input voltage range
at 80% load
min
max
4.50
6.00
10.80
14.40
13.50
18.00
21.60
28.80
25.20
33.60
43.20
57.60
Input voltage range
at 100% load
min
max
4.65
5.50
11.16
13.20
13.95
16.50
22.32
26.40
26.04
30.80
44.64
52.80
ii rfi
RFI current at
the input
typ Ui nom, Io nom
max Lsource = 1 µH
1% pp of Ii
3% pp of Ii
Ui abs
fs
Input voltage limits
without any damage
V
max max 60 s
6.75
6.20
20.25
32.40
37.80
64.80
Switching frequency
min Ui nom, Io nom
max
20
40
kHz
Table 6: Output Data
Output
5 V
12 V
15 V
Characteristics
Conditions
Unit
V
Uo
Output voltage
Output voltage accuracy max
Ui nom, Io nom
5
12
±0.5
15
∆Uo a
IoL
%
Output current
typ Ui nom
1.25 Io nom
limitation response
IoS
uo
Short-circuit current
of the output
typ Ui nom, Uo = 0
max
1.4 Io nom
2.0 Io nom
Output voltage noise
max Ui nom, Io nom
(BW = 20 MHz)
1
mVrms
mVpp
%
35
∆Uo U
Static line regulation
Static Load regulation
typ Ui min…Ui max
Io nom
±0.05
∆Uo I
uod
trr
typ Ui nom
Io = 0…Io nom
±0.1
50
Dynamic load regulation max
mV
Load transient
recovery time
typ
20
µs
αUo
Temperature coefficient
typ Ui nom, Io nom
max
±0.01
±0.03
%/K
Table 7: Efficiency
Efficiency
5 V
12 V
15 V
Characteristics
Conditions
Unit
%
η
Efficiency
min Ui nom, Io nom
typ
68
75
6 - 46
Edition 2/96 - © Melcher AG
MELCHER
The Power Partners.
Industrial Environment
DC-DC Converters <40 W
6 Watt-Family
Installation Instructions
Isolation Tests
Table 8: Isolation test voltage, coupling capacitance and
insulation resistance
Input to output isolation voltage tests are performed as fac-
tory tests (100%) and should not be repeated in the field.
Melcher will not honour any guarantee/warranty claims re-
sulting from high voltage field tests.
Characteristics
Conditions
ICR
500
Unit
Vrms
Vpp
V
Uis io Isolation test voltage
Input to output
AC: 50 Hz,
1 minute
1400
DC: 1 second 1 700
DC: 1 second 2 800
70
Cio
Ris
Couplingcapacitance typ
Insulation resistance
pF
at 100 V DC
≥1000 MΩ
after 1 minute
1 For production test purposes in accordance with IEC 950/
EN 60950
2 Factory test procedure
Connection in Series
If the outputs of one or more units are connected in series
each individual output should be protected by a zener diode
or preferably by a suppressor diode to avoid overvoltages
or reverse polarity at the individual outputs, e.g.:
– 1N5908 to protect 5 V outputs
+Vo
+Uo
Unit 1
Go
– BZW04-11 to protect 12 V outputs
– BZW04-14 to protect 15 V outputs
–Vo
(or equivalent types)
Such destructive voltages may occur at switch-on cycle of
the converters, if the output voltages do not rise at the same
time. The "slower" output(s) could be supplied and, as a
result, destroyed by the "faster" output(s) via the load. The
maximum output current is limited by the lowest current
limitation.
+Vo
Unit 2
Go
Connection in Parallel
–Vo
–Uo
Connection of the outputs of one or more units in parallel is
not permitted. The load distribution and the ripple values
could not be controlled.
Fig. 1
Outputs connected in series
Exception: .. ICR 5-05 (all 5 V single output units)
Cleaning
Submersion of the units in water for rinsing is permitted.
Drying should be done in the air.
Two CFC free cleaning solvents have been tested and can
be recommended:
– Prozone from BP
– Zestron from Dr. O. K. Wack Chemie GmbH (Germany)
Block Diagrams
Linear
+Vo
regulator
Linear
Vo
regulator
Vi
Go
Gi
Vi
Gi
Go
Linear
regulator
–Vo
Fig. 2
Fig. 3
ICR 5/6, group 02 (dual output)
ICR 5/6, group 01 (single output)
Edition 2/96 - © Melcher AG
6 - 47
MELCHER
The Power Partners.
6 Watt-Family
DC-DC Converters <40 W
Industrial Environment
Mechanical Data
Dimensions in mm. Tolerances ±0.2 mm, unless otherwise specified.
European
Projection
50.8
50.8
+0.0
10.5-0.2
+0.0
-0.2
23 ±0.5
5.1
Vo
23 ±0.5
5.1
min. 5
min. 5
10.5
Input
Gi Vi
Input
Gi
Vi
C
C
Go
–Vo Go +Vo
Output
Output
15.3 ±0.5
15.3 ±0.5
15.3 ±0.5
15.3 ±0.5
10.1
10.1
10.210.2
20.3
Bottom view
Bottom view
Fig. 4
Fig. 5
Single output, pin configuration C
Double output, pin configuration C
50.8
42
50.8
42
+0.0
10.5-0.2
+0.0
10.5-0.2
4.5 ±0.5
4.5 ±0.5
min. 5
min. 5
Gi
Vi
Gi
Vi
Input
Input
B
B
Output
Output
Go
Vo
-Vo
Go
+Vo
3.9 ±0.5
3.9 ±0.5
3.9 ±0.5
3.9 ±0.5
10.1
43.2
10.1
21.6
Bottom view
21.6
Bottom view
Fig. 6
Single output, pin configuration B
Fig. 7
Double output, pin configuration B
Type Key and Product Marking
Type Key
24 ICR 6 - 12 12 - T C
Nominal input voltage in volt .............. 5, 12, 15, 24, 28, 48
Family........................................................................... ICR
Nominal output power in watt....................................... 5, 6
Nominal output voltage for output 1 in volt......... 05, 12, 15
Nominal output voltage for output 2 in volt............... 12, 15
Ambient temperature range
TA = –25...71°C .................................................... T
TA = –40...85°C .................................................... S
Pin configuration ......................................................... C, B
Product Marking:
Main face: Manufacturer's name (IBEK), specific type designation, input and output pin allocation.
Bottom:
Date code.
6 - 48
Edition 2/96 - © Melcher AG
MELCHER
The Power Partners.
相关型号:
5ICR6-12-TCS
DC-DC Regulated Power Supply Module, 1 Output, 6W, Hybrid, 2 X 2 INCH, 10.50 MM HEIGHT, METAL PACKAGE
BEL
5ICR6-1212-SC
DC-DC Regulated Power Supply Module, 2 Output, 6W, Hybrid, 2 X 2 INCH, 10.50 MM HEIGHT, METAL PACKAGE-5
BEL
5ICR6-1212-TBS
DC-DC Regulated Power Supply Module, 2 Output, 6W, Hybrid, 2 X 2 INCH, 10.50 MM HEIGHT, METAL PACKAGE
BEL
5ICR6-15-SC
DC-DC Regulated Power Supply Module, 1 Output, 6W, Hybrid, 2 X 2 INCH, 10.50 MM HEIGHT, METAL PACKAGE-4
BEL
©2020 ICPDF网 联系我们和版权申明