ABC225_V01 [BEL]

225 W with Forced Air Cooling & 130 W with Convection Cooling;
ABC225_V01
型号: ABC225_V01
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

225 W with Forced Air Cooling & 130 W with Convection Cooling

文件: 总7页 (文件大小:600K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
The ABC225 Series of open frame power supplies feature a wide  
universal AC input range of 90 264 VAC, offering up to 225 W of  
output power in a compact 4 x 2 x 1 inch footprint, with a variety of  
isolated single output voltages.  
The high efficiency and high power density of the ABC family ensures  
minimal power loss in end-use equipment, thereby facilitating higher  
reliability, easier thermalmanagementand meets regulatory approvals  
for environmentally-friendlyend products.  
These power supplies are ideal for telecom, datacom, industrial  
equipment and other applications.  
Key Features & Benefits  
2 x 4 x 1 Inch Form Factor  
225 W with Forced Air Cooling & 130 W with Convection Cooling  
Efficiencies up to 94%  
No Load Power < 0.5 W  
-40 to 70°C Operating Temperature  
12 V / 0.5 A Fan Output, Thermal Shut-Down Feature  
3.37 Million Hours, Telcordia -SR332-Issue 3 MTBF  
IEC/EN/UL 62368-1 Certified  
CCC (China Compulsory Certification approval)  
Approved with metal enclosures/accessories  
RoHS Compliant  
Applications  
Instrumentation  
Renewable Energy  
Test and Measurement  
Robotics  
Lighting  
Industrial Applications  
Applied Computing  
Wireless Communication  
2
ABC225 Series  
1. MODEL SELECTION  
MAX. LOAD  
POWER  
MODELNUMBER 1  
DESCRIPTION  
VOLTAGE  
CONVECTION 50˚C  
CONVECTION 40˚C  
13 CFM  
(225 W)  
(112.5 W)  
(120 W)  
ABC225-1T12L  
ABC225-1012L  
ABC225-1T15L  
ABC225-1015L  
ABC225-1T24L  
ABC225-1024L  
ABC225-1T30L  
ABC225-1030L  
ABC225-1T48L  
ABC225-1048L  
ABC225-1T58L  
ABC225-1058L  
Screw Terminal  
Molex Connector  
Screw Terminal  
Molex Connector  
Screw Terminal  
Molex Connector  
Screw Terminal  
Molex Connector  
Screw Terminal  
Molex Connector  
Screw Terminal  
Molex Connector  
12 V  
15 V  
24 V  
30 V  
48 V  
58 V  
9.37 A  
7.50 A  
4.68 A  
3.75 A  
2.34 A  
1.94 A  
10.00 A  
8.00 A  
5.00 A  
4.00 A  
2.50 A  
2.07 A  
18.75 A  
15.00 A  
9.37 A  
7.50 A  
4.68 A  
3.88 A  
225 W  
225 W  
225 W  
225 W  
225 W  
225 W  
COVER-225-XBC2  
Metal cover kit (accessory)  
1
Class II version available. Add suffix “-2” at the end of the Model Number  
When used in Cover Kit, de-rate output power to 70 % under alloperating conditions.  
2
2. INPUT SPECIFICATIONS  
Specifications are for nominal input voltage, 25°C unless otherwise stated.  
PARAMETER  
Input Voltage  
Input Frequency  
Input Current  
DESCRIPTION / CONDITION  
SPECIFICATION  
Universal  
85 264 VAC / 390 VDC  
(Derate from 100% at 100 VAC to 90% at 85 VAC)  
47 63 Hz  
115 VAC:  
230 VAC:  
2.2 A max.  
1.1 A max.  
No Load Power  
Typical  
< 0.5 W  
115 VAC:  
230 VAC:  
25 A  
45 A  
Inrush Current  
264 VAC:  
Typical (N/A for Class II Option)  
Touch current:  
75 A  
300 µA  
< 100 µA  
Leakage Current  
Power Factor  
With Full Load  
> 0.95  
PFC:  
PWM:  
70 130 kHz  
50 80 kHz  
Switching Frequency  
tech.support@psbel.com  
3
ABC225 Series  
3. OUTPUT SPECIFICATIONS  
PARAMETER  
DESCRIPTION / CONDITION  
SPECIFICATION  
Output Voltage  
Refer to Model selection table  
From 12 V to 58 V  
With 13 CFM:  
Convection:  
48 V:  
225 W  
Up to 120 W  
94%  
Output Power3  
Efficiency  
24 V, 30 V:  
12 V, 15 V:  
225 W:  
93%  
92%  
10 ms  
16 ms  
Hold-up Time  
110 W:  
Line Regulation5  
Load Regulation5  
Minimum Load  
± 0.5%  
± 0.5%  
0.0 A  
25% step load change, at 0.1A/µs slew rate,  
50% duty cycle, 50 Hz = 4%  
Transient Response  
Recovery time < 5 ms  
Ripple4, 5  
For all outputs  
1.0 % max  
55 ms  
Rise Time  
Typical  
Set Point Tolerance 5  
Output Voltage Adjustment 6  
Over Current Protection  
Over Voltage Protection  
Short Circuit Protection  
± 1%  
± 3%  
>110%  
110 to 140%  
Hiccup mode  
With 13 CFM forced air cooling (100 to 264 VAC)7  
225 W  
Cooling  
With natural convection cooling (100 to 264 VAC)8  
Up to 120 W9  
3
Combined output power of main output, fan supply shall not exceed max. power rating.  
Ripple is peak to peak with 20 MHz bandwidth and 10 μF (Electrolytic capacitor) in parallelwith a 0.1 μF capacitor at rated line  
voltage and load ranges.  
4
5
Fan supply output voltage tolerance including set point accuracy, line and load regulation is +/-15 % and ripple and noiseis less  
than 10 %. With V1 fully loaded, Vfan need to have min load of20 mA to be within regulation band.  
Adjustment potentiometer is located on the SMT side of the PCB  
Refer to Mechanical Drawing  
6
7
8
9
Refer to Derating Curve  
For improved thermal performanceof ABC225 up to 130 W convection cooling, enquire with Sales Rep prior to placing an order.  
4. EMC SPECIFICATIONS  
PARAMETER  
DESCRIPTION / CONDITION  
SPECIFICATION  
Conducted Emissions  
EN 55032-B, CISPR22-B, FCC PART15-B  
Pass  
EN 55032 A;  
Pass  
Level B  
Radiated Emissions  
With external core (King core K5B RC 25x12x15-M in input cable)  
Input Current Harmonics  
Voltage Fluctuation and Flicker  
ESD Immunity  
EN 61000-3-2  
EN 61000-3-3  
EN 61000-4-2  
EN 61000-4-3  
EN 61000-4-4  
EN 61000-4-5  
EN 61000-4-6  
EN 61000-4-8  
EN 61000-4-11  
Class D  
Pass  
Level 3, Criterion A  
Level 3, Criterion A  
Level 3, Criterion A  
Level 3, Criterion A  
Level 3, Criterion A  
Level 3, Criterion A  
Criterion A & B  
Radiated Field Immunity  
Electrical Fast Transient Immunity  
Surge Immunity  
Conducted Immunity  
Magnetic Field Immunity  
Voltage Dips, Interruptions  
North America  
Asia-Pacific  
+86 755 298 85888  
Europe, Middle East  
+353 61 225 977  
+1 408 785 5200  
© 2020 Bel Power Solutions & Protection  
BCD.00554_AH  
4
ABC225 Series  
5. SAFETY SPECIFICATIONS  
PARAMETER  
DESCRIPTION / CONDITION  
SPECIFICATION  
Input to Output: (for ITE application)  
Input to GND: (N/A for Class II Option)  
3000 VAC  
1500 VAC  
Isolation Voltage  
IEC 62368-1:2018, IEC 60950-1(ed.2);am1;am2, EN 60950-1:2006;A11;A1;A12;A2,  
UL 62368-1 and CAN/CSA C22.2 No. 62368-1:19,  
Safety Standard(s)  
UL 60950-1 and CAN/CSA C22.2 No. 60950-1-07, GB4943.1-2011;GB9254-2008;GB17625.1-2012  
Agency Approvals  
CE mark  
Nemko, UL, C-UL, CCC  
Complies with LVD Directive  
6. ENVIRONMENTAL SPECIFICATIONS  
PARAMETER  
DESCRIPTION / CONDITION  
SPECIFICATION  
Operating Temperature  
-40 to +70°C  
-40 to 0°C startup guaranteed, with spec deviation 10  
Storage Temperature  
Relative Humidity  
-40 to +85°C  
5% to 95%  
Non-condensing  
Operating:  
Non-operating:  
16,000 ft.  
40,000 ft.  
Altitude  
Reliability  
MTBF according to Telcordia -SR332-Issue 3:  
3.37 million hours  
10  
Output ripple can be more than 10% ofthe output voltage.  
Convection load: 120 W up to 40 °C  
De-rate between 40-50 °C @ 0.625% per °C  
De-rate above 50 °C @ 2.33% per °C  
Forced air cooled load: 225 W up to 50°C  
De-rate above 50 °C @ 2.5% per °C  
Power de-rating with Cover Kit  
Convection load: 84 W up to 40 °C  
De-rate between 40-50 °C @ 0.625% per °C  
De-rate above 50 °C @ 2.33% per °C  
Figure 1. Derating Curves  
tech.support@psbel.com  
5
ABC225 Series  
Figure 2. Efficiency Graph at 115 VAC  
Figure 3. Efficiency Graph at 230 VAC  
7. CONNECTOR & PIN DESCRIPTION  
CONNECTOR  
PIN  
DESCRIPTION/CONDITION  
MANUFACTURER / PN  
Pin 1  
Pin 2  
Pin 3  
AC Line  
Not Fitted  
AC Neutral  
Molex: 26-60-4030  
Mating: 09-50-3031; Pins: 08-50-0106  
AC Input Connector  
J1  
Screw Terminal (Option 1)  
Molex Connector (Option 2)  
Molex: 39357 Series or equivalent  
Pin 1,2,3  
Pin 4,5,6  
V1 +VE  
V1 - VE  
DC Output Connector  
Aux (Fan) Output  
J2  
J3  
Molex: 26-60-4060  
Mating: 09-50-3061; Pins: 08-50-0106  
AMP: 640456-2  
Pin 1  
Pin 2  
FAN +VE  
FAN - VE  
Mating: 640440-2  
8. MECHANICAL SPECIFICATIONS  
PARAMETER  
Weight  
DESCRIPTION/CONDITION  
200 g approx.  
50.8 x 101.6 x 25.4 mm (2 x 4 x 1 inch)  
Dimensions  
North America  
Asia-Pacific  
+86 755 298 85888  
Europe, Middle East  
+353 61 225 977  
+1 408 785 5200  
© 2020 Bel Power Solutions & Protection  
BCD.00554_AH  
6
ABC225 Series  
Figure 4. Mechanical Drawing Screw Terminal (Option 1)  
Figure 5. Mechanical Drawing Molex Connector (Option 2)  
tech.support@psbel.com  
7
ABC225 Series  
Figure 6. Mechanical Drawing With Cover Kit  
NOTES: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following:  
1
2
3
Stand off, used to mount PCB has OD of 5.4 mm max.  
Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.  
Washer, if used, to have dia of 6.5 mm max.  
For more information on these products consult: tech.support@psbel.com  
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for useas critical components in life support systems,  
equipment used in hazardous environments, or nuclear control systems.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the  
date manufactured. Specifications are subject to change without notice.  
North America  
Asia-Pacific  
Europe, Middle East  
+86 755 298 85888  
+353 61 225 977  
+1 408 785 5200  
© 2020 Bel Power Solutions & Protection  
BCD.00554_AH  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 211
-
VISHAY