ABC550_V01 [BEL]
Up to 550 Watts with Forced Air Cooling;型号: | ABC550_V01 |
厂家: | BEL FUSE INC. |
描述: | Up to 550 Watts with Forced Air Cooling |
文件: | 总8页 (文件大小:1391K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
The ABC550 Series of open frame power supplies feature a wide
universal AC input range of 90 – 264 VAC, offering up to 550 W of
output power with forced air cooling, or 250 W with conduction cooling
in a compact footprint, with a variety of isolated single output voltages.
The high efficiency and high power density of the ABC family ensures
minimal power loss in end-use equipment, thereby facilitating higher
reliability, easier thermal management and meets regulatory approvals
for environmentally-friendly end products.
These power supplies are ideal for medical, telecom, datacom,
industrial equipment and other applications.
5 x 3 x 1.5 Inch Form Factor
•
•
•
•
•
•
•
•
Up to 550 Watts with Forced Air Cooling
Efficiencies up to 92%
-40 to 70°C Operating Temperature
12 V / 0.5 A Fan Output, Thermal Shut-Down Feature
MTBF >3 million hours as per Telcordia SR-332, Issue 3
RoHS Compliant
CE Marked
Instrumentation
Lighting
Renewable Energy
Test and Measurement
Robotics
•
•
•
•
•
•
•
•
Industrial Applications
Applied Computing
Wireless Communication
2
ABC550 Series
ABC550-1T12
ABC550-1T15
ABC550-1T24
ABC550-1T30
ABC550-1T48
ABC550-1T58
12 V
15 V
24 V
30 V
48 V
58 V
9.17 A
7.33 A
6.25 A
5.00 A
3.13 A
2.59 A
16.67 A
13.33 A
10.42 A
8.33 A
5.21 A
4.31 A
41.67 A
33.33 A
22.92 A
18.33 A
11.46 A
9.48 A
500 W
500 W
550 W
550 W
550 W
550 W
Specifications are for nominal input voltage, 25°C unless otherwise stated.
Universal
90-264 VAC / 390 VDC
47-63 Hz
Input Voltage
Input Frequency
Input Current
(Derate from 100% at 115 VAC to 78% at 90 VAC)
115 VAC:
230 VAC:
115 VAC:
230 VAC:
115 VAC:
230 VAC:
264 VAC:
115 VAC:
230 VAC:
6 A max.
3 A max.
< 0.5 W
< 0.7 W
25 A
45 A
75 A
No Load Power
Inrush Current
< 200 µA
< 400 µA
Leakage Current
Power Factor
@ Full Load
> 0.95
PFC
Resonant
70 to 130 kHz
68 to 80 kHz
Switching Frequency
Forced air cooled:
Conduction cooled:
Convection cooled:
48 V:
24 V:
12 V, 15 V:
up to 550 W
up to 250 W
up to 150 W
92%
91%
90%
Output Power 2
Efficiency typical @ 230 VAC full load)
(
Full Load
Convection Load
Conduction Load
> 16 ms
> 55 ms
> 30 ms
Hold-up Time (typical)
Line Regulation 4
Load Regulation 4
Minimum Load
+/-0.5%
+/-1%
0.0 A
50-100% step load change, at 0.1A/µs slew rate,
50% duty cycle, 50 Hz = 5%
12 V & 15 V
Transient Response
recovery time < 5 ms
2.0 % max
1.0 % max
Ripple 3, 4
24 V, 30 V, 48 V & 58 V
Output Voltage Adjustment
+/-3%
tech.support@psbel.com
3
ABC550 Series
Rise Time
Typical
55 ms
Set Point Tolerance 4
Over Current Protection
Over Voltage Protection
Short Circuit Protection
+/-1%
Hiccup mode / Auto recovery
Hiccup mode / Auto recovery
Hiccup mode / Auto recovery
> 110%
110 to 140%
Convection Cooled (refer to Derating Curve)
Conduction Cooled (refer to Derating Curve)
400 LFM Forced Air Cooled (refer to Derating Curve)
Up to 150 W max
Up to 250 W max
Up to 550 W max
Cooling
Operating Temperature 5
-40 to +70°C
-40 to 0°C startup guaranteed, with spec deviation 6
Non-condensing
Storage Temperature
Relative Humidity
-40 to +85°C
5% to 95%
Operating:
Non-operating:
16,000 ft.
40,000 ft.
Altitude
Conducted Emissions
Radiated Emissions
EN 55032-B, CISPR22-B, FCC PART15-B
EN 55032 A;
with external core (King core K5B RC 25x12x15-M in input cable)
Pass
Pass
Level B
Input Current Harmonics
Voltage Fluctuation and Flicker
ESD Immunity
EN 61000-3-2
Class D
EN 61000-3-3
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
Pass
Level 3, Criterion A
Level 3, Criterion A
Level 3, Criterion A
Level 3, Criterion A
Level 3, Criterion A
Level 3, Criterion A
Criterion A & B
Radiated Field Immunity
Electrical Fast Transient Immunity
Surge Immunity
Conducted Immunity
Magnetic Field Immunity
Voltage Dips, Interruptions
North America
+1 408 785 5200
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
© 2020 Bel Power Solutions & Protection
BCD.00831_AC
4
ABC550 Series
Input to Output: (for ITE applications)
Input to GND:
3000 VAC
1500 VAC
Isolation Voltage
UL 62368-1 & CAN/CSA C22.2 No. 62368-1:19, UL 60950-1 and CAN/CSA C22.2 No. 60950-1-07
IEC 62368-1:2018, IEC 60950-1(ed.2);am1;am2
Safety Standard(s)
EN 62368-1:2014;A11, EN 60950-1:2006;A11;A1;A12;A2
Agency Approvals
CE mark
Nemko, UL, C-UL
Complies with LVD Directive
Pin 1
Pin 2
Pin 3
AC Line
Not Fitted
JST : B3P-VH-B(LF)(SN) or equivalent
AC Input Connector
J1
J2
Mating: VHR-3M or equivalent Pins : SVH-41T-P1.1 or equivalent
AC Neutral
6-32 inches Screw Pan HD
Mating: Designed to accept Ring Tongue Terminal AMP: 8-31886-1,
wherein one 16 AWG (max) wire can be crimped.
Note: One Ring Tongue Terminal with 16 AWG is recommended for
current up to 11 A only.
DC Output
Connector
(Screw Terminal)
Pin 1
Pin 2
V1 +VE
V1 -VE
Use multiple tongue terminals with wire for more current.
AMP: 640456-2
Mating: 640440-2
Pin 1
Pin 2
FAN +VE
FAN -VE
Aux (Fan) Output
Earth
J3
J4
Molex: 19705-4301
Mating: 19003-0001
Weight
approx. 500 g
Dimensions
127 x 76.2 x 38.1 mm (5 x 3 x 1.5 inches)
Figure 1. Mechanical Drawing
tech.support@psbel.com
5
ABC550 Series
De-rate linearly from 100% at 115
VAC to 78% at 90 VAC
Convection load: 110 W up to 50 °C
De-rate above 50 °C @ 2.5% per °C
Conduction load: 200 W up to 50 °C
De-rate above 50 °C @ 2.5% per °C
Forced air cooled load:
500 W up to 50°C
De-rate above 50 °C @ 2.5% per °C
Convection load: 150 W up to 50 °C
De-rate above 50 °C @ 2.5% per °C
Conduction load: 250 W up to 50 °C
De-rate above 50 °C @ 2.5% per °C
Forced air cooled load:
550 W up to 50°C
De-rate above 50 °C @ 2.5% per °C
North America
Asia-Pacific
Europe, Middle East
+1 408 785 5200
+86 755 298 85888
+353 61 225 977
© 2020 Bel Power Solutions & Protection
BCD.00831_AC
6
ABC550 Series
For reliable and safe operation, please make sure the maximum component temperatures given in table below is not exceeded.
TOP PCB
BOTTOM PCB
MAXIMUM TEMP.
ALLOWED (°C)
INDENT NO
DESCRIPTION
1
2
3
4
Common mode chokes
Input Bulk Capacitors
Differential choke
Boost Choke
95
90
110
110
125 (for 12 V & 15 V)
110 (for 24 V,30 V,48 V,58 V)
5
Output Transformer
6
7
8
9
Output Capacitor
Bridge Rectifier
90
120
105
110
Aluminum Clad PCB
Output Rectifiers
tech.support@psbel.com
7
ABC550 Series
FIXING OPTION - 2
FIXING OPTION - 1
Figure 2. Mounting Options
North America
+1 408 785 5200
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
© 2020 Bel Power Solutions & Protection
BCD.00831_AC
8
ABC550 Series
Conduction power rating mentioned in the table is with additional aluminum base plate of 3 mm thickness with 177.8 mm (7in) length
& 101.6 mm (4in) width.
Clearance of minimum 15 mm above the component height is recommended for better thermal management.
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.