The ABC75 Series of open frame power supplies feature a wide
universal AC input range of 85 V – 264 VAC, offering 75 W of output
power in a compact 3 x 2 x 1 inch footprint, with a variety of isolated
single output voltages.
The high efficiency and high power density of the ABC family ensures
minimal power loss in end-use equipment, thereby facilitating higher
reliability, easier thermal management and meets regulatory approvals
for environmentally-friendly end products.
ABC Series power supplies are ideal for telecom, datacom, industrial
equipment and other applications.
3 x 2 x 1 Inch Form Factor
75 Watts with Convection Cooling
Efficiency up to 93%
•
•
•
•
•
•
•
•
•
•
•
-40 to 70°C Operating Temperature
Thermal Shut-Down Feature
2 Million Hours, Telcordia -SR332-Issue 3
IEC/EN/UL 62368-1 Certified
CCC (China Compulsory Certification approval)
No Load Power < 0.3 W
RoHS Compliant
CE Marked
Instrumentation
Lighting
Renewable Energy
Test and Measurement
Robotics
•
•
•
•
•
•
•
•
Industrial Applications
Applied Computing
Wireless Communication
2
ABC75 Series
ABC75-1T12L
ABC75-1012L
Screw Terminal
Molex Header
12 V
15 V
24 V
30 V
48 V
58 V
6.25 A
5.00 A
3.12 A
2.50 A
1.56 A
1.29 A
75 W
75 W
75 W
75 W
75 W
75 W
ABC75-1T15L
ABC75-1015L
Screw Terminal
Molex Header
ABC75-1T24L
ABC75-1024L
Screw Terminal
Molex Header
ABC75-1T30L
ABC75-1030L
Screw Terminal
Molex Header
ABC75-1T48L
ABC75-1048L
Screw Terminal
Molex Header
ABC75-1T58L
ABC75-1058L
Screw Terminal
Molex Header
COVER-120-XBC 2
Metal cover kit accessory
1
For Class II version contact Bel sales representative.
When used in Cover Kit, de-rate output power to 70 % under all operating conditions.
2
Specifications are for nominal input voltage, 25°C unless otherwise stated.
Universal
Input Voltage
85 – 264 VAC / 390 VDC 3
(Derate from 75 W @ 100 VAC to 65 W @ 85 VAC)
Input Frequency
Input Current
47 – 63 Hz
115 VAC:
230 VAC:
1 A max.
0.5 A max.
No Load Power
Typical
< 0.3 W
115 VAC:
230 VAC:
264 VAC:
25 A
45 A
75 A
Inrush Current
Power Factor
@ Full Load, Active PFC
Typical
> 0.95
60 kHz
Switching Frequency
3
Functional, not approved.
tech.support@psbel.com
3
ABC75 Series
Output Voltage
Output Power
Refer to Model selection table
Convection cooling
From 12 V to 58 V
75 W
48 V, 58 V:
24 V, 30 V:
12 V, 15 V:
93%
91%
90%
Efficiency
Hold-up Time
Typical
>16 ms
+/-0.5%
+/-1%
0.0 A
Line Regulation
Load Regulation
Minimum Load
25% step load change, at 0.1A/uS slew rate,
50% duty cycle, 50 Hz = 4%
Transient Response
recovery time < 5 ms
Ripple 4
For all outputs
1.0 % max.
+/-3%
Output Voltage Adjustment
Rise Time
Typical
55 ms
Set Point Tolerance
Over Current Protection
Over Voltage Protection
Short Circuit Protection
+/-1%
> 110%
110 to 140%
Latch type (AC recycling required)
Hiccup mode
Cooling
With natural convection cooling for input 100 – 264 VAC
75 W
4
μ
μ
Ripple is peak to peak with 20 MHz bandwidth and 10 F (Electrolytic capacitor) in parallel with a 0.1 F capacitor at rated line
voltage and load ranges.
Conducted Emissions
Radiated Emissions
EN 55032-B, CISPR22-B, FCC PART15-B
EN 55032 A;
with external core (King core K5B RC 25x12x15-M in input cable)
Pass
Pass
Level B
Input Current Harmonics
Voltage Fluctuation and Flicker
ESD Immunity
EN 61000-3-2
EN 61000-3-3
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
Class D
Pass
Level 3, Criterion A
Level 3, Criterion A
Level 3, Criterion A
Level 3, Criterion A
Level 3, Criterion A
Level 3, Criterion A
Criterion A & B
Radiated Field Immunity
Electrical Fast Transient Immunity
Surge Immunity
Conducted Immunity
Magnetic Field Immunity
Voltage Dips, Interruptions
Input to Output: (for ITE application)
Input to GND:
3000 VAC
1500 VAC
Isolation Voltage
IEC 62368-1:2018, EN 62368-1:2014; A11,
UL 62368-1 and CAN/CSA C22.2 No. 62368-1:19, GB17625.1-2012; GB4943.1-2011; GB/T9254-2008
Safety Standard(s)
Agency Approvals
CE mark
Nemko, UL, C-UL, CCC
Complies with LVD Directive
North America
Asia-Pacific
Europe, Middle East
+1 408 785 5200
+86 755 298 85888
+353 61 225 977
© 2020 Bel Power Solutions & Protection
BCD.00664_AE
4
ABC75 Series
Operating Temperature
Storage Temperature
Cooling
-40 to 0°C startup guaranteed, with spec deviation 5
-40 to +70°C
-40 to +85°C
75 W
With natural convection cooling at 100 to 264 VAC
Noncondensing
Relative Humidity
5% to 95%
Operating:
Nonoperating:
16,000 ft
40,000 ft.
Altitude
Reliability
MTBF according to Telcordia -SR332-Issue 3
2.00 million hours
5
Output ripple can be more than 10% of the output voltage.
Convection load: 75W up to 50°C
De-rate above 50 °C @ 2.5% per °C
Power de-rating with Cover Kit
Convection load: 52.5W up to 50 °C
De-rate above 50 °C @ 2.5% per °C
Figure 1. Derating Curves
tech.support@psbel.com
5
ABC75 Series
Molex: 39357-0003
Tyco-2-1776112-3
Molex: 1722861103
(Mating conn: Molex 1722561003,
Molex 1722561103,
Molex 1722563103)
Molex: 39357-0004
Tyco-2-1776112-4
Molex: 1722861104
(Mating conn: Molex 1722561004,
Molex 1722561104,
Screw Terminal (Option 1)
Molex Header (Option 2)
Screw Terminal (Option 1)
Molex Header (Option 2)
Pin 1
Pin 2
Pin 3
AC Line
Not Fitted
AC Neutral
AC Input Connector
DC Output Connector
J1
J2
Pin 1, 2
Pin 3, 4
V1 -VE
V1 +VE
Molex 1722563104)
Weight
180 g max
Dimensions
Cooling
76.2 x 50.8 x 25.4 mm (3 x 2 x 1 inch)
75 W with natural convection cooling at 100 to 264 VAC
Figure 2. Mechanical Drawing - Screw Terminal (Option 1)
North America
+1 408 785 5200
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
© 2020 Bel Power Solutions & Protection
BCD.00664_AE
6
ABC75 Series
Figure 3 - Mechanical Drawing - Molex Header (Option 2)
tech.support@psbel.com
7
ABC75 Series
Figure 4 - Mechanical Drawing - With Cover Kit
NOTES: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following:
1
2
3
Stand off, used to mount PCB has OD of 5.4 mm max.
Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
Washer, if used, to have dia of 6.5 mm max.
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
North America
Asia-Pacific
Europe, Middle East
+1 408 785 5200
+86 755 298 85888
+353 61 225 977
© 2020 Bel Power Solutions & Protection
BCD.00664_AE
相关型号:
©2020 ICPDF网 联系我们和版权申明