ABE1000 [BEL]

Form Factor 5 x 9.51 x 1.61 in (127 x 241.5 x 41 mm);
ABE1000
型号: ABE1000
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

Form Factor 5 x 9.51 x 1.61 in (127 x 241.5 x 41 mm)

文件: 总8页 (文件大小:771K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
The ABESeries power suppliesfeature a wide universal ACinputrange  
of 85 264 VAC, offering up to 1000 W of output power and a variety  
of single output voltages.  
The high efficiency and high power density of the ABE series ensures  
minimal power loss in end-use equipment, thereby facilitating higher  
reliability, easier thermalmanagementand meets regulatory approvals  
for environmentally-friendlyend products.  
These power supplies are ideal for medical, telecom, datacom,  
industrial equipment and other applications.  
Form Factor 5 x 9.51 x 1.61 in (127 x 241.5 x 41 mm)  
Universal Input  
Current Sharing Option  
Peak Power Capability  
5 VDC Stand by output  
In built 12 V fan output  
Power Good / Power Fail Signal  
Suitable in POE applications  
Lesser than 1U high  
High voltage output range up to 58 VDC  
N+1 redundant power supply  
Single wire current sharing  
Built in OR-ing diode / FET (- R suffix)  
Instrumentation  
Lighting  
Renewable Energy  
Test and Measurement  
Robotics  
Industrial Applications  
Applied Computing  
Wireless Communication  
2
ABE1000 Series  
ABE1000-1T12  
ABE1000-1T15  
ABE1000-1T24  
ABE1000-1T30  
ABE1000-1T48  
ABE1000-1T58  
12 V  
15 V  
24 V  
30 V  
48 V  
58 V  
Fan Cooled  
Fan Cooled  
Fan Cooled  
Fan Cooled  
Fan Cooled  
Fan Cooled  
41.67 A  
41.67 A  
41.67 A  
33.33 A  
20.83 A  
17.24 A  
0.0 A  
0.0 A  
0.0 A  
0.0 A  
0.0 A  
0.0 A  
2%  
2%  
2%  
2%  
2%  
2%  
1
For Ripplemeasurement minimumoutput power requirement is 25 W.  
Ripple is peak to peak with 20 MHz bandwidth and10 µF (Electrolyticcapacitor)in parallel with a 0.1 µF capacitor at rated linevoltageand  
load ranges.  
Specifications are for nominal input voltage, 25°C unless otherwise stated.  
Input Voltage  
Universal  
85 264 VAC / 120 390 VDC  
47 63 Hz  
Input Frequency  
120 VAC:  
240 VAC:  
11 A max.  
5.5 A max.  
Input Current  
Input Protection  
No Load Power  
In Live & Neutral both  
Over entire input range with main output kept OFF using  
Remote ON/OFF  
F16 A / 250 V  
3 W typ.  
Inrush Current  
Leakage Current  
Touch Current  
240 VAC:  
25 A max.  
400 µA  
< 100 µA  
240 VAC / 50 Hz  
120 VAC:  
240 VAC:  
0.98  
0.95  
Power Factor  
PFC converter: Variable  
Resonant converter: Variable  
85 kHz typical  
100 kHz typical  
Switching Frequency  
tech.support@psbel.com  
3
ABE1000 Series  
Output Voltage  
Refer to Model Selection table for details  
12 V to 58 V  
5 V  
Standby Output Voltage2  
Output Power3  
Fan Cooled (Peak 1200 W for 1 ms)  
1000 W  
120 VAC:  
240 VAC:  
88 % Typical  
93 %  
Efficiency  
Hold-up Time  
Line Regulation  
Load Regulation  
120 VAC / 240 VAC:  
8 ms  
± 0.5 %  
± 1.0 %  
< 10 %,  
recovery time < 5 ms  
Transient Response  
50% to 100% load change, 50 Hz, 50% duty cycle, 0.1 A/µs  
Voltage Adjustment  
Set Point Tolerance  
Rise Time  
± 3 %  
± 1%  
<100 ms  
120 to 150 %  
114%  
Over Current Protection  
Over Voltage Protection  
Short Circuit Protection  
Over Temperature Protection  
Current Share  
Hic-Up Type, autorecovery  
Latch Type, AC Power to be recycled for recovery  
Short term, autorecovery  
Autorecovery  
130-140°C primary heat sink  
Up to 3 supplies connected in parallel (optional)  
Fan cooled  
Cooling  
1000 W  
2
Standby output voltage5 V / 1.5 A with toleranceincluding set point accuracy, lineand load regulation is +/-10%.Rippleandnoiseis less  
than 5%.  
Combinedoutput power of main output,fan supply and standby supply shall not exceed max. power rating.  
3
Conducted Emissions  
Radiated Emissions  
EN 55032  
Class B  
EN 55032  
Class A Class B  
With External king core K5BRC 25x12x15-M or equivalent  
Input Current Harmonics  
Voltage Fluctuation and Flicker  
ESD Immunity  
EN 61000-3-2  
EN 61000-3-3  
EN 61000-4-2  
EN 61000-4-3  
EN 61000-4-4  
EN 61000-4-5  
EN 61000-4-6  
EN 61000-4-8  
EN 61000-4-11  
Class A  
Complies  
A
Radiated Field Immunity  
Electrical Fast Transient Immunity  
Surge Immunity  
A
A
A
Conducted Immunity  
A
Magnetic Field Immunity  
Voltage Dips, Interruptions  
A
A & B  
Input to Output  
Input to Earth  
4000 VDC  
2500 VDC  
Isolation Voltage  
IEC/EN62368-1, Ed 2  
UL62368, CSA C22-2 NO- 62368-1  
Safety Standard(s)  
Agency Approvals  
CE mark  
Nemko, UL, C-UL  
Complies with LVD Directive  
North America  
Asia-Pacific  
Europe, Middle East  
+86 755 298 85888  
+353 61 225 977  
+1 408 785 5200  
© 2020 Bel Power Solutions & Protection  
BCD.00972_D  
4
ABE1000 Series  
Operating Temperature  
Refer to derating curve  
Non-condensing  
-40 to +70°C  
-40 to +85°C  
5% to 95%  
Storage Temperature  
Relative Humidity  
Operating:  
Non-operating:  
16,000 ft.  
40,000 ft.  
Altitude  
MTBF  
Telcordia -SR332-issue 3  
3.37 million hours  
Power Good: Is a TTL signal which goes high after main output reaches 90% of its set value.  
The delay is 0.1 s to 0.5 s  
Power Fail: Thesamesignalgoes lowat least 1ms before main output falls to 90% ofset value at AC Power off  
Power Good / Fail Signal  
Remote Sense  
Compensates for 200 mV drop  
Pin 6 & Pin 7 of J3 can be used for Remoteon/off.  
Shorting Pin 6 to Pin 7 enables main output while keeping the pins open disables main output  
Note: Provision of Inhibit RemoteON/OFF is available. +5 V at Pin 7 will switch offthe main output.  
Remote On / Off  
OCP Limit Set  
Pin 8 & Pin 9 of J3 must be shorted  
Figure 1. Power Good / Fail Signal Diagram  
Pin 1  
Pin 2  
Pin 3  
AC Line  
Neutral  
Earth  
AC Input Connector  
DC Output Connector  
J1  
J2  
TE Connectivity: NC6-P107-03  
6-32 inches Screw Pan HD  
Mating: Designed to accept Ring Tongue Terminal AMP: 8-31886-1,  
wherein one 16 AWG (max) wire can be crimped.  
Note: One Ring TongueTerminal with 16 AWG is recommended for  
current up to 11 A only.  
J2-A  
J2-B  
+VE  
-VE  
Use multiple tongue terminals with wire for more current.  
tech.support@psbel.com  
5
ABE1000 Series  
Pin 1  
Pin 2  
Pin 3  
Pin 4  
Pin 5  
Pin 6  
Pin 7  
Pin 8  
Pin 9  
Pin 10  
GND  
5V AUX  
PGPF  
VS –  
VS +  
GND  
RMT  
CL2  
Molex: 22-23-2101  
Mating: 22-01-2107; Pins: 08-50-0113  
Signal Connector  
J34  
CL1  
LS  
TE Connectivity AMP Connectors  
Description: CONN HEADERVERT 2 POS 2.54 mm,  
Pin 1  
Pin 2  
+VE  
-VE  
Fan Output5  
J10, J11  
MPN: 640456-2  
Mating: 3-641535-2 / TE Connectivity AMP Connectors  
or: 0022013027 / MOLEX with crimping 08-50-0114 / MOLEX  
4
PSU is suppliedwith J3, pin-6 andpin-7 shortedto enable main output without remoteon/off feature.  
Fan supply output voltageis 12 V / 500 mA with regulation band ±30 % andRipple is less than 10%.To get 12 V Fan supply output voltage,  
minimum10 % load on Main output voltageis required.  
5
Figure 2. Power Derating w.r.t Input  
De-rate between 30-50 °C @ 0.833% per °C  
De-rate above 50 °C @ 2.5% per °C  
Figure 3. Power Derating Curve 12 V  
North America  
Asia-Pacific  
Europe, Middle East  
+86 755 298 85888  
+353 61 225 977  
+1 408 785 5200  
© 2020 Bel Power Solutions & Protection  
BCD.00972_D  
6
ABE1000 Series  
De-rate between 30-50 °C @ 0.833% per °C  
De-rate above 50 °C @ 2.5% per °C  
Figure 4. Power Derating Curve 15 V  
De-rate between 30-50 °C @ 0.833% per °C  
De-rate above 50 °C @ 2.5% per °C  
Figure 5. Power Derating Curve 24 V and above  
Weight  
Dimensions  
1300 g  
Weight  
127 x 241.5 x 41 mm (5 x 9.51 x 1.61 inches)  
tech.support@psbel.com  
7
ABE1000 Series  
During the installation and setup of parallel supplies in a system it is important that a single remote sense point be used for all the  
supplies. The remote sense voltage between the supplies must be adjusted to within 1% to ensure the supplies are inside the 1%  
capture window. If the supplies are not initially adjusted inside the capture window the supplies will not current share satisfactorily.  
SET-UP PROCEDURE:  
North America  
Asia-Pacific  
Europe, Middle East  
+86 755 298 85888  
+353 61 225 977  
+1 408 785 5200  
© 2020 Bel Power Solutions & Protection  
BCD.00972_D  
8
ABE1000 Series  
1. Connect load cables to the outputs of each supply.  
2. Connect the remote sense lines to the load in twisted style. (A common remote sense point must be used for all the supplies in  
parallel).  
3. Connect all the “LS” signal (Pin 10) on the J3 connector between the supplies.  
4. Adjust remote sense voltage of each supply to within 1% of rated output voltage or readjust to required set point. (Adjustment  
to be done with all other parallel supplies off).  
5. Current sharing between the supplies can be verified by monitoring the output current of each supply with a hall effect DC  
current probe. The supplies should share to within 10% of the total load current.  
6. The current share circuit has a capture window voltage of +/- 1% of the rated output voltage. If the output remote sense  
voltage of one of the supplies is adjusted outside the 1% window the supplies will not current share satisfactorily.  
Figure 7. Current Sharing Block Diagram  
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for useas critical components in life support systems,  
equipment used in hazardous environments, or nuclear control systems.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the  
date manufactured. Specifications are subject to change without notice.  
tech.support@psbel.com  

相关型号:

ABE1000-1T12

Form Factor 5 x 9.51 x 1.61 in (127 x 241.5 x 41 mm)
BEL

ABE1000-1T15

Form Factor 5 x 9.51 x 1.61 in (127 x 241.5 x 41 mm)
BEL

ABE1000-1T24

Form Factor 5 x 9.51 x 1.61 in (127 x 241.5 x 41 mm)
BEL

ABE1000-1T30

Form Factor 5 x 9.51 x 1.61 in (127 x 241.5 x 41 mm)
BEL

ABE1000-1T48

Form Factor 5 x 9.51 x 1.61 in (127 x 241.5 x 41 mm)
BEL

ABE1000-1T58

Form Factor 5 x 9.51 x 1.61 in (127 x 241.5 x 41 mm)
BEL

ABE10DHFD

CONN EDGE DUAL FMALE 20POS 0.039
ETC

ABE10DHFN

CONN EDGE DUAL FMALE 20POS 0.039
ETC

ABE10DHFR

CONN EDGE DUAL FMALE 20POS 0.039
ETC

ABE10DHFT

CONN EDGE DUAL FMALE 20POS 0.039
ETC

ABE10DHHD

CONN EDGE DUAL FMALE 20POS 0.039
ETC

ABE10DHHN

CONN EDGE DUAL FMALE 20POS 0.039
ETC