EWD505-81V [BEL]

DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid;
EWD505-81V
型号: EWD505-81V
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid

输出元件
文件: 总3页 (文件大小:97K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
EWD DC/DC Series Data Sheet  
Features  
Description  
Industry-standard package  
Industry-Standard Pinout  
85°C case operation  
Short-circuit protection  
5V and 12V inputs  
Input pi filter  
6-sided shielding  
Regulated outputs  
500V isolation  
EWD dual-output DC/DC converters offer excellent  
regulation and isolation in an industry-standard package.  
Available in several input versions, the EWD is perfect for  
industrial, datacom, or telecom applications. The EWD  
features short-circuit protection, six-sided shielding, and  
500 VDC isolation. Please see the EWS series for single-  
output applications.  
Efficiency vs. Load (5V Input)  
90  
85  
80  
75  
70  
65  
60  
55  
50  
Technical Specifications  
EFF. (505)  
EFF. (512)  
EFF. (515)  
Input  
Voltage Range  
5 VDC Nominal  
12 VDC Nominal  
4.5 - 9 VDC  
9 - 18 VDC  
Reflected Ripple  
20% I Max.  
in  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
LOAD %  
Reverse Input Current  
100% I Max.  
in  
Output  
Efficiency vs. Load (12V Input)  
Setpoint Accuracy  
1%  
Line Regulation V Min. - V Max., I  
Rated  
1.0% V  
in  
in  
out  
out  
90  
Load Regulation I  
Min. - I  
Max., V Nom.  
1.0% V  
85  
80  
75  
70  
65  
60  
55  
50  
out  
out  
in  
out  
Minimum Output Current  
10 % I  
Rated  
out  
Dynamic Regulation, Loadstep  
Pk Deviation  
25% I  
out  
out  
1% V  
Eff. EWD1205  
Eff. EWD1212  
Settling Time  
Temperature Coefficient  
Ripple and Noise, 20 MHz BW  
500 m s  
0.02%/°C  
1% V  
nom.  
out  
1
Short Circuit Protection  
Current Limit  
Hiccup  
130%  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
LOAD %  
General  
Switching Frequency  
Isolation  
Input - Output  
200 kHz  
Notes  
Converter will auto-restart once fault has been removed.  
1
500 VDC  
9
Isolation Resistance - Input to Output  
Standard Case Operating Range  
Industrial Range (Add -I To P/N)  
Storage Range  
Humidity Max., Non-Condensing  
Vibration, 3 Axes, 5 Min. each  
Safety  
10 Ohms  
-25 To +85°C  
-40 To +85°C  
-40 To +125°C  
95%  
Specifications typically at 25°C, normal line, and full load unless otherwise  
stated.  
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with  
commercial wave-soldering equipment.  
5 g, 10 - 55 Hz  
UL, cUL, TUV  
1.4 oz  
Safety: Agency approvals may vary from model to model. Please consult  
factory for specific model information.  
Weight (Approx.)  
REV. JUL 30, 2003  
Page 1 of 3  
EWD DC/DC Series Data Sheet  
Model Selection  
INPUT VOLTAGE  
INPUT VOLTAGE  
RANGE (VOLTS)  
MAXIMUM INPUT  
CURRENT (AMPS)*  
OUTPUT  
VOLTAGE (VOLTS)  
RATED OUTPUT  
CURRENT (AMPS)  
RIPPLE & NOISE  
pk-pk (mV)  
TYPICAL  
EFFICIENCY**  
MODEL  
(VOLTS)  
EWD505  
EWD512  
EWD515  
EWD1205  
EWD1212  
5
5
5
12  
12  
4.5 - 9  
4.5 - 9  
4.5 - 9  
9 - 18  
9 - 18  
1.64  
1.85  
1.85  
0.69  
0.75  
±5  
±12  
±15  
±5  
±0.50  
±0.25  
±0.20  
±0.50  
±0.25  
50  
120  
150  
50  
72%  
81%  
81%  
80%  
82%  
±12  
120  
NOTES:  
*
Maximum input current at minimum input voltage, maximum rated output power.  
** At nominal V , rated output.  
in  
Model numbers highlighted in yellow or shaded are not recommended for new designs.  
Mechanical Drawing  
Thermal Impedance  
Pin  
Function  
Tolerances  
Natural convection  
100 LFM  
200 LFM  
300 LFM  
400 LFM  
15.4 °C/W  
Inches:  
.XX 0.040  
.XXX .010  
(Millimeters)  
.X 1.0  
.XX 0.25  
1
2
3
+Vin  
-Vin  
+ Vout  
Common  
12.2 °C/W  
9.3 °C/W  
7.4 °C/W  
6.4 °C/W  
Pin:  
0.002  
0.05  
4
5
Note:  
- Vout  
Thermal impedance data is dependent on  
many environmental factors. The exact  
thermal performance should be validated  
for specific application.  
Case:  
+ 0.04, - 0.00  
+ 1.0, - 0.0  
(Tolerances as listed unless otherwise  
specified.)  
REV. JUL 30, 2003  
Page 2 of 3  
OPTIONS  
This page is offered as a reference. Consult factory for actual availability of options. When ordering  
equipment options, use the following suffix information. Select preferred option(s) and add the suffix to the  
model number. Ordering option examples are located below the options table.  
OPTION  
Negative Logic  
SUFFIX  
APPLICABLE SERIES  
REMARKS  
N
HAS, HBD, HBS, HES, HLS, HLD, LES,  
QBS, QES, QLS, TES, TQD  
TTL "Low" Turns Module ON  
TTL "High" Turns Module OFF  
Lucent-Compatible Trim  
T
HAS, HBD, HBS, HES, HLS, QBS, QES,  
QLS  
Trim  
1
2
3
IAS, LES  
Enable  
IAD, IAS, LES, SMS  
IAS, LES  
Trim and Enable  
Pin Length and Heatsink Options  
0.110" (2.8mm) Pin Length  
Standard Pin Length is 0.180" (4.6mm)  
8
9
All Leaded Models  
All Leaded Models  
0.150" (3.8mm) Pin Length  
0.24" (6.1mm) Horizontal Heatsink  
1H  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
Includes Thermal Pad  
Includes Thermal Pad  
Includes Thermal Pad  
Includes Thermal Pad  
Includes Thermal Pad  
Includes Thermal Pad  
0.24" (6.1mm) Vertical Heatsink  
0.45" (11.4mm) Horizontal Heatsink  
0.45" (11.4mm) Vertical Heatsink  
0.95" (24.1mm) Horizontal Heatsink  
0.95" (24.1mm) Vertical Heatsink  
1V  
2H  
2V  
3H  
3V  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
Example Options:  
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95” vertical heatsink.  
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.  
QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110” pin length.  
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,  
equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president  
of Power-One, Inc.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the  
date manufactured. Specifications are subject to change without notice.  
REV. JUL 30, 2003  
Page 3 of 3  

相关型号:

EWD505-81V-I

DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid
BEL

EWD505-82H

DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid
BEL

EWD505-82H-I

DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid
BEL

EWD505-82V

DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid
BEL

EWD505-82V-I

DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid
BEL

EWD505-83H-I

DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid
BEL

EWD505-83V

DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid
BEL

EWD505-83V-I

DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid
BEL

EWD505-9-I

DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid
BEL

EWD505-91H-I

DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid
BEL

EWD505-91V

DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid
BEL

EWD505-91V-I

DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid
BEL