FRD4812-81H [BEL]
DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid;型号: | FRD4812-81H |
厂家: | BEL FUSE INC. |
描述: | DC-DC Regulated Power Supply Module, 2 Output, 5W, Hybrid |
文件: | 总3页 (文件大小:86K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
ꢀꢀ
ꢀꢀ
(888) IPD-CONVerters
(888) 473-2668
www.ipdconverters.com
FRD SERIES - DUAL OUTPUT, 5 WATT
DESCRIPTION
FEATURES
• 500V Isolation
• Short Circuit Protection
• 6-Sided Shielding
FRD dual output DC/DC converters offer excellent
regulation and isolation in an industry standard
package. Available in several input versions, the FRD
is perfect for industrial, datacom, or telecom
• Wide Input Range
• Trim and Enable Pins
• Remote Sense Pins
applications. The FRD features short circuit
protection, six-sided shielding, and 500 VDC isolation.
Please see the FRS series for single output applications.
Efficiency vs. Load (28V Input)
80
75
70
65
60
55
50
45
40
35
EFF. FRD2812
EFF. FRD2815)
10
20
30
40
50
60
70
80
90
10
LOAD %
TECHNICAL SPECIFICATIONS
Input
Voltage Range
5V, 12V, 24V, 28V, and 48V Nominal
See selection chart for specific input range.
Efficiency vs. Load (48V Input)
Reflected Ripple
20% Iin Max.
100% Iin Max.
70
65
60
55
50
45
40
35
30
25
Reverse Input Current
Output
Setpoint Accuracy
±1% Vout
±0.15% Vout
EFF. FRD4812
EFF. FRD4815
Line Regulation Vin Min. - Vin Max., Iout Rated
Load Regulation Iout Min. - Iout Max., Vin Nom.
Minimum Output Current
±0.15% Vout Iout Rated
10 % lout Rated
Short Circuit Protection1
Continuous
10
20
30
40
50
60
70
80
90
10
LOAD %
General
Switching Frequency
Isolation
Input - Output
Isolation Resistance - Input to Output
Case Temperature
Operating Range
20 kHz
Notes
500 VDC
109 Ohms
†
MTBF predictions may vary slightly from model to model.
-25 To +85°C
-40 To +125°C
95%
±0.02%/°C
5 g, 10 - 55 Hz
Consult Factory
2.2 oz
Specifications typically at 25°C, normal line, and full load, unless otherwise stated.
Storage Range
Humidity Max, Non-Condensing
Temperature Coefficient
Vibration, 3 Axes, 5 Min Each
Safety
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
Weight (Approx.)
C-64
FRD SERIES - DUAL OUTPUT, 5 WATT
MODELS - (See the last page of this file for options.)
Vin
(Volts)
Vin Range
(Volts)
Iin Max.*
(Amps)
Vout
(Volts)
Iout Rated
(Amps)
Ripple & Noise
Pk-Pk (mV)
Efficiency
Typ. **
Model
5
5
4.65 - 5.50
4.65 - 5.50
2.01
2.04
0.85
0.86
0.43
0.45
0.37
0.38
0.21
0.22
±12
±15
±12
±15
±12
±15
±12
±15
±12
±15
±0.23
±0.19
±0.23
±0.19
±0.23
±0.19
±0.23
±0.19
±0.23
±0.19
40
40
40
40
40
40
40
40
40
40
65%
66%
66%
67%
66%
65%
69%
71%
65%
66%
FRD512
FRD515
12
12
24
24
28
28
48
48
10.90 - 13.20
10.90 - 13.20
21.60 - 26.40
21.60 - 26.40
25.20 - 30.80
25.20 - 30.80
43.20 - 52.80
43.20 - 52.80
FRD1212
FRD1215
FRD2412
FRD2415
FRD2812
FRD2815
FRD4812
FRD4815
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
MECHANICAL DRAWING
Tolerances
Pin
Function
Thermal Impedance
Inches:
.XX ± 0.040
.XXX ± 0.010
(Millimeters)
.X ± 1.0
.XX ± 0.25
Natural convection
10.3 °C/W
7.7 °C/W
6.3 °C/W
5.1 °C/W
4.1 °C/W
1
2
3
4
5
+Vin
100 LFM
200 LFM
300 LFM
400 LFM
-Vin
+ Vout
Common
- Vout
Pin:
± 0.002
± 0.05
Note:
Case:
+ 0.04, - 0.00
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated
for specific application.
+ 1.0, - 0.0
(Tolerances as listed unless otherwise specified.)
C-65
OPTIONS
When ordering equipment options, use the following suffix information. Select the option(s) that
you prefer and add them to the model number. Example ordering options are located below the
options table.
OPTION
Negative Logic
SUFFIX
APPLICABLE SERIES
REMARKS
N
HAS, HBD, HBS, HES, LES, QBS,
QES, TES, TQD
TTL “Low” Turns Module ON
TTL “High” Turns Module OFF
Lucent Compatible Trim
Terminal Strip
Trim
T
TS
1
HAS, HBD, HBS, HES, QBS, QES
XWS, XWD, XWT
IAS, LES
Enable
2
IAD, IAS, LES, SMS
IAS, LES
Trim and Enable
Current Share
Headerless
3
4
SMS
Y
Encapsulated EWS, IWS, OWS
PIN LENGTH AND HEATSINK
OPTIONS
Standard Pin Length is 0.180”
(4.6mm)
0.110” (2.8mm) Pin Length
0.150” (3.8mm) Pin Length
0.24” (6.1mm) Horizontal Heatsink
8
9
All Units (Except SMS)
All Units (Except SMS)
1H
All Units (Except DIP, SIP, and SM
Packages)
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
0.24” (6.1mm) Vertical Heatsink
1V
2H
2V
3H
3V
All Units (Except DIP, SIP, and SM
Packages)
0.45” (11.4mm) Horizontal
Heatsink
All Units (Except DIP, SIP, and SM
Packages)
0.45” (11.4mm) Vertical Heatsink
All Units (Except DIP, SIP, and SM
Packages)
0.95” (24.1mm) Horizontal
Heatsink
All Units (Except DIP, SIP, and SM
Packages)
0.95” (24.1mm) Vertical Heatsink
All Units (Except DIP, SIP, and SM
Packages)
Example Options:HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and
0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
C105
相关型号:
©2020 ICPDF网 联系我们和版权申明