HC15-3-AC [BEL]
AC-DC Regulated Power Supply Module, 1 Output, Hybrid, MODULE-9;型号: | HC15-3-AC |
厂家: | BEL FUSE INC. |
描述: | AC-DC Regulated Power Supply Module, 1 Output, Hybrid, MODULE-9 |
文件: | 总9页 (文件大小:834K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Linear Power Supplies Data Sheet
Features
•
Worldwide AC Input Capabilities:
100/120/220/230/240 VAC
•
•
•
•
±0.05% Output Regulation
Low Output Ripple
UL, CSA, and TÜV Approvals
Mean Time Before Failure (MTBF) in Excess of
300,000 Hours
•
•
•
•
CE marked to Low Voltage Directive
100% Burn-In
2 Year Warranty
Overvoltage Protection (OVP) Standard on 5V
Single Outputs, Optional for other outputs under 48V
Description
Power-One produces the industry’s broadest selection of The Linear power supplies are approved to domestic and
Linear power supplies with output voltages from 5 volts international regulatory standards, and are CE Marked to
through 250 volts. Rugged technology and proven design the Low Voltage Directive (LVD).
merge to create quiet, highly-regulated, dependable DC
power.
Overvoltage Protection Options
OVERVOLTAGE PROTECTION OPTIONS
These optional overvoltage protection modules are offered for use with
OVP SELECTION GUIDE
MODEL
CASE SIZE
OVP MODULES REQUIRED
Power-One’s Linear power supplies. Each is user adjustable from 6.4V to 34V.
B,C,N,D
(1) OVP-12
SINGLE
OUTPUT
E,F
AA,B,BB,CC
E
(1) OVP-24
OVP-12
(1) OVP-12 protects both outputs
(1) OVP-24 protects both outputs
DUAL
OUTPUT
AA,BAA,D
CBB, 131
DBB,DCC
(1) OVP-12 protects both 12V
through 15V outputs
TRIPLE
OUTPUT
N,BAA,CBB
131, CP340-A
CP510-A
PEAK
CURRENT
MODELS
(1) OVP-12 protects any output
not provided with built-in OVP
NOTE: Outputs with factory built-in OVP are indicated in the Voltage/Current Rating
Chart for each model. OVP is not available for 48V through 250V models.
OVP-24
REV. JAN 16, 2006
Page 1 of 9
www.power-one.com
Linear Power Supplies Data Sheet
Case
Type
Dimensions
(Inches)
Unsigned output voltages are isolated and can be used as either + or - polarities.
AA
6.50 x 4.00 x 2.10
4.87 x 4.00 x 2.10
10.25 x 4.00 x 2.95
7.00 x 4.87 x 2.95
5.62 x 4.87 x 2.95
11.00 x 4.87 x 3.28
9.38 x 4.87 x 3.28
11.00 x 4.87 x 3.28
Output
Voltage
(VDC)
Output
Current
(Amps)
Model
(Input Voltage
of 100 to 240VAC)
B
Additional
Features & Notes
Case
Type
BAA
BB
Single Output Models- 5V to 48Vout
5
C
1.5
3
HA5-1.5/OVP-A
HB5-3/OVP-A
HC5-6/OVP-A
HN5-9/OVP-A
HD5-12/OVP-A
HE5-18/OVP-A
F5-25/OVP-A
G5-35/OVP-A
CP197-A
B
B
C
N
D
E
F
A
CBB
CC
5
A, C
5
6
A, C
CP131
5
9
A, C
CP510-A 8.25 x 4.87 x 3.28
5
12
18
25
35
50
1.7
3.4
5.1
6.8
10.2
0.9
16
1.5
3
A, C
D
9.00 x 4.87 x 3.28
14.25 x 4.87 x 3.38
15.00 x 4.88 x 4.55
14.00 x 4.87 x 3.53
16.75 x 4.88 x 5.00
7.00 x 4.87 x 3.28
5
A, C
DBB
DCC
E
5
A, C, D, H
5
F
A, C, D, H
5
F
A, C, D
F
12
HB12-1.7-A
HC12-3.4-A
HN12-5.1-A
HD12-6.8-A
HE12-10.2-A
HA15-0.9-A
F15-15-A
B
C
N
D
E
B
F
C
C
C
C
C
N
12
Case
Type
AA
Dimensions
(Millimeters)
12
12
165.10 x 101.60 x 53.34
123.70 x 101.60 x 53.34
260.35 x 101.60 x 74.93
177.80 x 123.70 x 74.93
142.75 x 123.70 x 74.93
279.40 x 123.70 x 83.31
238.25 x 123.70 x 83.31
279.40 x 123.70 x 83.31
12
B
12 to 15
12 to 15
15
BAA
BB
C, D, H
HB15-1.5-A
HC15-3-A
B
C
N
D
E
B
C
N
D
E
B
F
C
C
C
C
C
C
C
C
C
C
C
15
CBB
CC
15
4.5
6
HN15-4.5-A
HD15-6-A
15
CP131
15
9
HE15-9-A
CP510-A 209.55 x 123.70 x 83.31
24
1.2
2.4
3.6
4.8
7.2
0.5
12
1
HB24-1.2-A
HC24-2.4-A
HN24-3.6-A
HD24-4.8-A
HE24-7.2-A
HA24-0.5-A
F24-12-A
D
228.60 x 123.70 x 83.31
361.95 x 123.70 x 85.85
381.00 x 123.95 x 115.57
355.60 x 123.70 x 89.66
425.50 x 123.95 x 127.00
177.80 x 123.70 x 83.31
24
DBB
DCC
E
24
24
24
F
24 to 28
24 to 28
28
N
C, D, H
HB28-1-A
B
C
N
D
E
B
C
D
E
C
C
C
C
C
(See Additional Features Column)
28
2
HC28-2-A
A
B
C
D
Overvoltage protection, set at 6.2 V 0.4 V.
Non-adjustable 3-terminal regulator.
Remote sense provided.
28
3
HN28-3-A
28
4
HD28-4-A
With output inhibit and parallel
28
6
HE28-6-A
operation master/slave capability.
48
0.5
1
HB48-0.5-A
HC48-1-A
E
F
G
With output inhibit.
Adjustable 3-terminal regulator.
48
Can be made into an isolated output by
48
3
HD48-3-A
C
C
removing jumper W1.
48
4
HE48-4-A
H
Model requires 100 LFM forced-air
cooling above 75% of rated output
power at 50 degrees C.
REV. JAN 16, 2006
Page 2 of 9
www.power-one.com
Dual-Output Models
Linear Power Supplies Data Sheet
Unsigned output voltages are isolated and can be used as either + or - polarities.
Case
Type
AA
Dimensions
(Inches)
Output
Voltage
(VDC)
Output
Current
(Amps)
Model
(Input Voltage
of 100 to 240VAC)
6.50 x 4.00 x 2.10
4.87 x 4.00 x 2.10
10.25 x 4.00 x 2.95
7.00 x 4.87 x 2.95
5.62 x 4.87 x 2.95
11.00 x 4.87 x 3.28
9.38 x 4.87 x 3.28
11.00 x 4.87 x 3.28
Additional
Features & Notes
Case
Type
B
BAA
BB
Dual Output Models- 5V to 15Vout
+5, –5
1.5, 1.5
3, 3
HAA5-1.5/OVP-A
HBB5-3/OVP-A
HCC5-6/OVP-A
CP323-A
AA
BB
CC
N
A
C
+5, –5
A
CBB
CC
+5, –5
6, 6
A, C
A, E
A
+5, +12
2, 4
CP131
+5, +12
6, 2.5
2, 0.5
3, 1.25
6, 2.5
1, 0.4
1.7, 0.7
0.4, 0.4
1, 1
CP510-A
CP510-A
AA
BB
CC
AA
BB
B
CP510-A 8.25 x 4.87 x 3.28
5, 12 to 15
5, 12 to 15
5, 12 to 15
+12, –5
HAA512-A
A, C
A, C
A, C
C
D
9.00 x 4.87 x 3.28
14.25 x 4.87 x 3.38
15.00 x 4.88 x 4.55
14.00 x 4.87 x 3.53
16.75 x 4.88 x 5.00
7.00 x 4.87 x 3.28
HBB512-A
DBB
DCC
E
HCC512-A
HAA15-0.8-A
HBB15-1.5-A
HAD12-0.4-A
HAA15-0.8-A
HBB15-1.5-A
HCC15-3-A
HDD15-5-A
HAA15-0.8-A
HBB15-1.5-A
HCC15-3-A
HDD15-5-A
HAA15-0.8-A
HBB15-1.5-A
HAA15-0.8-A
HBB15-1.5-A
HCC15-3-A
HDD15-5-A
+12, –5
C
F
+12, –12
+12, –12
+12, –12
+12, –12
+12, –12
+12, –15
+12, –15
+12, –15
+12, –15
+15, –5
B
N
AA
BB
CC
E
C
1.7, 1.7
3.4, 3.4
5, 5
C
Case
Type
AA
Dimensions
(Millimeters)
C
165.10 x 101.60 x 53.34
123.70 x 101.60 x 53.34
260.35 x 101.60 x 74.93
177.80 x 123.70 x 74.93
142.75 x 123.70 x 74.93
279.40 x 123.70 x 83.31
238.25 x 123.70 x 83.31
279.40 x 123.70 x 83.31
C
B
1, 0.8
1.7, 1.5
3.4, 3
5, 5
AA
BB
CC
E
C
BAA
BB
C
C
C
C
CBB
CC
0.8, 0.4
1.5, 0.7
0.8, 1
1.5, 1.7
3, 3.4
5, 5
AA
BB
AA
BB
CC
E
C
+15, –5
C
CP131
+15, –12
+15, –12
+15, –12
15, –12
C
CP510-A 209.55 x 123.70 x 83.31
C
D
228.60 x 123.70 x 83.31
361.95 x 123.70 x 85.85
381.00 x 123.95 x 115.57
355.60 x 123.70 x 89.66
425.50 x 123.95 x 127.00
177.80 x 123.70 x 83.31
C
DBB
DCC
E
C
Dual Output Models- 15V to 24Vout
+15, –15
0.4, 0.4
0.8, 0.8
1.5, 1.5
3, 3
HAD15-0.4-A
HAA15-0.8-A
HBB15-1.5-A
HCC15-3-A
B
B
C
C
C
C
F
+15, –15
AA
BB
CC
E
N
+15, –15
+15, –15
(See Additional Features Column)
+15, –15
5, 5
HDD15-5-A
A
B
C
D
Overvoltage protection, set at 6.2 V 0.4 V.
Non-adjustable 3-terminal regulator.
Remote sense provided.
+18 to +20, –18 to –20
+18 to +20, –18 to –20
+18 to +20, –18 to –20
+18 to +20, –24
+18 to +20, –24
+18 to +20, –24
+24, –18 to –20
+24, –18 to –20
+24, –18 to –20
+24, –24
0.4, 0.4
0.9, 0.9
1.8, 1.8
0.4, 0.6
0.9, 1.2
1.8, 2.4
0.6, 0.4
1.2, 0.9
2.4, 1.8
0.6, 0.6
1.2, 1.2
2.4, 2.4
HAA24-0.6-A
HBB24-1.2-A
HCC24-2.4-A
HAA24-0.6-A
HBB24-1.2-A
HCC24-2.4-A
HAA24-0.6-A
HBB24-1.2-A
HCC24-2.4-A
HAA24-0.6-A
HBB24-1.2-A
HCC24-2.4-A
AA
BB
CC
AA
BB
CC
AA
BB
CC
AA
BB
CC
With output inhibit and parallel
C
C
C
C
operation master/slave capability.
E
F
G
With output inhibit.
Adjustable 3-terminal regulator.
Can be made into an isolated output by
removing jumper W1.
H
Model requires 100 LFM forced-air
cooling above 75% of rated output
power at 50 degrees C.
+24, –24
+24, –24
Model numbers highlighted in yellow or shaded are not recommended for new designs.
REV. JAN 16, 2006
Page 3 of 9
www.power-one.com
Linear Power Supplies Data Sheet
Unsigned output voltages are isolated and can be used as either + or - polarities.
Case
Type
AA
Dimensions
(Inches)
Output
Voltage
(VDC)
Output
Current
(Amps)
Model (Input
Voltage of
Additional Features)
& Notes
Case
Type
6.50 x 4.00 x 2.10
4.87 x 4.00 x 2.10
10.25 x 4.00 x 2.95
7.00 x 4.87 x 2.95
5.62 x 4.87 x 2.95
11.00 x 4.87 x 3.28
9.38 x 4.87 x 3.28
11.00 x 4.87 x 3.28
100 to 240VAC)
B
Triple Output Models- 5V to 24Vout
+5, –5, 24
BAA
BB
6, 1.2, 3.5
CP379-A
CP131
BAA
A, C, F, G
A, C
A, C
A, C, F
A, C
A, C
A
5, +12, –5
3, 1, 0.4
HBAA-40W-A
HCAA-60W-A
CP498-A
C
+5, +12 to +15, –5
+5, +12, 5
6, 1, 0.4
D
CBB
CC
6, 5, 0.25
8, 1.7, 0.7
12, 1.7, 0.7
2, 0.4, 0.4
6, 1.7, 0.7
3, 1, 1
CP131
CP131
DBB
AA
5, +12, –5
CP131-A
CP131
5, +12, –5
HDBB-105W-A
HTAA-16W-A
HCBB-75W-A
HBAA-40W-A
HCAA-60W-A
CP498-A
CP510-A 8.25 x 4.87 x 3.28
5, +12 to +15, –5
5, +12, –5
D
9.00 x 4.87 x 3.28
14.25 x 4.87 x 3.38
15.00 x 4.88 x 4.55
14.00 x 4.87 x 3.53
16.75 x 4.88 x 5.00
7.00 x 4.87 x 3.28
CBB
C
DBB
DCC
E
5, +12, –12
+5, +12 to +15, –12 to –15
+5, +12, 12
5, +12, –12
5, +12, –12
5, +12, –12
5, +12 to +15, –12 to –15
5, +12, –12
5, +12, –15
5, +12, –15
5, +12, –15
5, +12, –15
5, +12, –15
+5, –12, 24
5, +15, –5
BAA
A, C
A, C
A, C, F
C
6, 1, 1
D
6, 5, 0.5
CP131
CBB
F
6, 1.7, 1.7
8, 1.7, 1.7
12, 1.7, 1.7
2, 0.4, 0.4
12, 3.4, 3.4
3, 1, 0.8
HCBB-75W-A
CP131-A
N
CP131
DBB
AA
A, C
C
HDBB-105W-A
HTAA-16W-A
HDCC-150W-A
HBAA-40W-A
HCBB-75W-A
CP131-A
Case
Type
AA
Dimensions
(Millimeters)
A
165.10 x 101.60 x 53.34
123.70 x 101.60 x 53.34
260.35 x 101.60 x 74.93
177.80 x 123.70 x 74.93
142.75 x 123.70 x 74.93
279.40 x 123.70 x 83.31
238.25 x 123.70 x 83.31
279.40 x 123.70 x 83.31
DCC
BAA
A, C
A, C
C
B
BAA
BB
6, 1.7, 1.5
8, 1.7, 1.5
12, 1.7, 1.5
12, 3.4, 3
6, 1.2, 3.5
3, 0.8, 0.4
6, 1.5, 0.7
8, 1.5, 0.7
12, 1.5, 0.7
3, 0.8, 1
CBB
CP131
DBB
DCC
CP131
BAA
A, C
C
C
HDBB-105W-A
HDCC-150W-A
CP379-A
CBB
CC
A, C
A, C, F, G
A, C
C
CP131
HBAA-40W-A
HCBB-75W-A
CP131-A
CP510-A 209.55 x 123.70 x 83.31
5, +15, –5
CBB
D
228.60 x 123.70 x 83.31
361.95 x 123.70 x 85.85
381.00 x 123.95 x 115.57
355.60 x 123.70 x 89.66
425.50 x 123.95 x 127.00
177.80 x 123.70 x 83.31
5, +15, –5
CP131
DBB
BAA
A,
DBB
DCC
E
5, +15, –5
HDBB-105W-A
HBAA-40W-A
HCBB-75W-A
CP131-A
C
5, +15, –12
5, +15, –12
5, +15, –12
5, +15, –12
5, +15, –12
5, +15, –15
5, +15, –15
5, +15, –15
5, +15, –15
5, +15, –15
A, C
C
6, 1.5, 1.7
8, 1.5, 1.7
12, 1.5, 1.7
12, 3, 3.4
3, 0.8, 0.8
6, 1.5, 1.5
8, 1.5, 1.5
12, 1.5, 1.5
12, 3, 3
CBB
F
CP131
DBB
DCC
BAA
A, C
C
N
HDBB-105W-A
HDCC-150W-A
HBAA-40W-A
HCBB-75W-A
CP131-A
A, C
A, C
C
(See Additional Features Column)
A
B
C
D
Overvoltage protection, set at 6.2 V 0.4 V.
Non-adjustable 3-terminal regulator.
Remote sense provided.
CBB
CP131
DBB
DCC
A, C
C
With output inhibit and parallel
HDBB-105W-A
HDCC-150W-A
operation master/slave capability.
A, C
E
F
G
With output inhibit.
Adjustable 3-terminal regulator.
Quad Output Models- 5V to 24Vout Models
+5, +12, –5, +24
Can be made into an isolated output by
6, 1, 0.5, 2.4
CP503-A
CP503-A
CP131
CP131
A, H
A, H
removing jumper W1.
+5, +12, –12, +24
6, 1, 1, 2.4
H
Model requires 100 LFM forced-air
cooling above 75% of rated output
power at 50 degrees C.
Model numbers highlighted in yellow or shaded are not recommended for new designs.
REV. JAN 16, 2006
Page 4 of 9
www.power-one.com
Linear Power Supplies Data Sheet
Input Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Input Voltage - AC
(Note 1, 2)
Jumper selectable, shipped factory configured for
120VAC operation. All models must be externally
fused for proper operation. Fuse ratings are marked
on each unit. Consult factory for each unit’s fuse
requirements.
100 VAC Tap
120 VAC Tap
220 VAC Tap
240 VAC Tap
87
100
120
220
240
110
132
242
264
104
191
209
VAC
Input Frequency
Line Regulation
AC input.
47
-0.01
-1.0
-0.5
-0.05
63
+0.01
+1.0
+0.5
+0.05
Hz
%
Output voltage charge for a 10% line change: F case models.
HAD12, HAD15.
Outputs with adjustable three terminal regulators.
All other models.
NOTES: 1) Derate output current 10% for 50Hz operation.
2) Input voltage tolerance for 230VAC operation is +15%, -10%.
Output Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Output Adjustment
Efficiency
Minimum output adjustment range (Note 1).
5 volt outputs.
12 volt and 15 volt outputs.
24 volt and higher outputs.
-5
+5
%
45
55
60
%
F case models.
3.0
5.0
0.2
mVPK-PK
mVPK-PK
%PK-PK
Ripple and Noise
(Note 2)
5 volt, 12 volt, and 15 volt models.
All three terminal regulator outputs.
24 volt through 250 volt models.
3.0mVPK-PK plus 0.02% of output voltage, max
Load Regulation
Output change for a 50% load change: F case models.
HAD12, HAD15.
-0.02
-1
+0.02
+1
%
Outputs with adjustable three terminal regulators.
All other models.
-0.5
-0.05
+0.5
+0.05
Transient Response
Recovery time, to within 1% of initial set point due to a 50% load change.
50
μs
NOTES: 1) OUTPUT VOLTAGE ADJUSTMENTS: Output voltage adjustments can be made to within ±5% of nominal voltage. Locate the “Vadj” potentiometer on the power
supply PCB and use a screwdriver to adjust the output pot. The HAD12 and HAD15 3-terminal regulator outputs are not adjustable.
2) Full load, 20MHz bandwidth.
Safety, Regulatory, and EMI Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Agency Approvals
UL60950 3rd Edition.
CSA 60950 3rd Edition.
EN60950 3rd Edition.
IEC60950 3rd Edition
Approved
Dielectric Withstand
Voltage
Input to output.
Input to ground.
3750
3750
VRMS
Electromagnetic
Interference
FCC CFR title 47 Part 15 Sub-Part B - conducted.
EN55022 / CISPR 22 conducted.
EN55022 / CISPR 22 radiated.
Compatible with system compliance to Level B.
Leakage Current
Per EN60950
(264VAC)
23
50
μA
Interface Signals and Internal Protection
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Overvoltage Protection
Provided on 5 volt output units where indicated.
Other outputs may use optional overvoltage protectors OVP-12 and OVP-24.
5.8
6.6
V
Remote Sense
Total voltage compensation for cable losses with respect to the main output.
Provided on models where indicated.
250
mV
Overcurrent/Short Circuit
Protection
Automatic current limit/foldback. Rated as a percentage of output power.
115
120
140
%
Master/Slave Operation
For parallel operation of up to 6 units. Master/slave pin provided on F case models only. Contact factory for application notes.
REV. JAN 16, 2006
Page 5 of 9
www.power-one.com
Linear Power Supplies Data Sheet
Environmental Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Operating Temperature
Derate output power linearly above 50°C by 3% per °C.
At 100% load
At 40% load
0
50
70
°C
°C
Storage Temperature
-40
85
°C
Temperature Coefficient
0°C to 50°C (after 15 minute warm-up).
24 hours after warm-up.
0.1
0.3
+0.3
%/°C
%
-0.3
Shock
Vibration
Relative Humidity
Operating.
20
6.15
95
GPK
GRMS
%RH
Random vibration from 10 Hz to 2 kHz, 3 axis.
Non-Condensing.
5
REV. JAN 16, 2006
Page 6 of 9
www.power-one.com
Linear Power Supplies Data Sheet
REV. JAN 16, 2006
Page 7 of 9
www.power-one.com
Linear Power Supplies Data Sheet
REV. JAN 16, 2006
Page 8 of 9
www.power-one.com
Linear Power Supplies Data Sheet
NUCLEAR AND MEDICALAPPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
REV. JAN 16, 2006
Page 9 of 9
www.power-one.com
相关型号:
HC15030
Board Connector, 6 Contact(s), 2 Row(s), Male, Right Angle, 0.1 inch Pitch, Solder Terminal, Black Insulator, Receptacle
FOXCONN
HC15037
Board Connector, 6 Contact(s), 2 Row(s), Male, Right Angle, 0.1 inch Pitch, Solder Terminal, Black Insulator, Receptacle
FOXCONN
HC15041
Board Connector, 8 Contact(s), 2 Row(s), Male, Right Angle, 0.1 inch Pitch, Solder Terminal, Black Insulator, Receptacle
FOXCONN
HC15071
Board Connector, 14 Contact(s), 2 Row(s), Male, Right Angle, 0.1 inch Pitch, Solder Terminal, Black Insulator, Receptacle
FOXCONN
©2020 ICPDF网 联系我们和版权申明