HES050ZD-A3V [BEL]
DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid, HALF BRICK PACKAGE-9;型号: | HES050ZD-A3V |
厂家: | BEL FUSE INC. |
描述: | DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid, HALF BRICK PACKAGE-9 局域网 |
文件: | 总3页 (文件大小:100K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
HES DC-DC Series Data Sheet
Half-Brick Converters
Description
HES single-output dc-dc converters provide up to 150
watts of output power in an industry-standard, half-brick
package and footprint. These units feature ultra-high
efficiency, Class A conducted noise specifications, and
fixed switching frequency. The HES is designed with
open-frame packaging, along with planar magnetics to
provide maximum useable power with minimal thermal
constraints. The HES is especially suited to harsh
telecom, networking, and industrial applications, and is
fully compatible with production board washing processes.
Features
• High efficiency
• Industry standard half-brick • “True-Trim” option
• Open-frame packaging • 1500V isolation
• 100°C baseplate operation • Positive or negative
logic
• Water washable
Technical Specifications
Input
Voltage Range
24 VDC Nominal
48 VDC Nominal
Reflected Ripple
18 - 36 VDC
36 - 72 VDC
50 mA
Input Reverse Voltage Protection
Input Undervoltage Lockout / Hysteresis
Shunt Diode
<34V/1V Nom.
Output
Setpoint Accuracy
1%
Line Regulation V Min. - V Max., I
Rated
0.2% V
Efficiency vs. Load (48V Input)
in
in
out
out
Load Regulation I
Remote Sense Headroom
Minimum Output Current
Min. - I
Max., V Nom.
0.2% V
out
out
out in
95
90
85
80
0.5 VDC
10 %
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
25% I
out
4% V
out
500 ms
10%
75
HES033ZE
Voltage Trim Range
70
65
60
55
50
HES075ZG
HES100ZE
Short Circuit / Overcurrent Protection
Current Limit Threshold Range, % of I
OVP Trip Range
Shutdown / Hiccup
110 - 130%
Rated
out
120 - 140% V Nom.
out
OVP Type
Self Recovering
General
1
2
3
4
5
6
7
8
9
10
X10 = LOAD %
Turn-On Time
10 ms
Remote Shutdown
Positive Or Negative Logic
Remote Shutdown Reference
Switching Frequency 2.5 & 3.3, 5V Model
Isolation
V Negative
200 kHz, 300 kHz (Respectively)
in
Notes
†
MTBF predictions may vary slightly from model to model.
Input - Output
Input - Case
Output - Case
Temperature Coefficient
Case Temperature
1500 VDC
1050 VDC
500 VDC
0.02%/°C
Specifications typically at 25°C, normal line, and full load, unless
otherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully
compatible with commercial wave-soldering equipment.
Operating Range
Storage Range
-40 To +100°C
-40 To +125°C
105 To 115°C
5 g, 10 - 55 Hz
Thermal Shutdown Range
Vibration, 3 Axes, 5 Min Each
Safety: Agency approvals may vary from model to model. Please
consult factory for specific model information.
6
†
MTBF (Bellcore Tr-nwt-000332)
1.8 X 10 hrs
Safety
Weight (Approx.)
UL 1950, CSA 22.2-950, EN60950
1.4 oz
Units are water-washable and fully compatible with commercial spray
or immersion post wave-solder washing equipment.
REV. JUN 04, 2004
Page 1 of 3
HES DC-DC Series Data Sheet
Half-Brick Converters
Model Selection
INPUT VOLTAGE
INPUT VOLTAGE
RANGE (VOLTS)
MAXIMUM INPUT
CURRENT (AMPS)*
OUTPUT
VOLTAGE (VOLTS)
RATED OUTPUT
CURRENT (AMPS)
RIPPLE & NOISE
pk-pk (mV)
TYPICAL
EFFICIENCY**
MODEL
(VOLTS)
HES075YD-A
HES100YE-AT
HES033ZE-A
HES050ZG-A
HES037ZD-A
HES050ZE-AN
HES075ZG-A
HES050ZD-A
HES066ZE-AT
HES100ZG-A
HES075ZD-A
HES100ZE-A
HES150ZG-A
24
24
48
48
48
48
48
48
48
48
48
48
48
48
18-36
18-36
36-72
36-72
36-72
36-72
36-72
36-72
36-72
36-72
36-72
36-72
36-72
36-72
5.5
7.4
2.5
3.3
3.3
5
2.5
3.3
5
2.5
3.3
5
2.5
3.3
5
30
30
10
10
15
15
15
20
20
20
30
30
30
30
150
100
100
100
100
100
100
100
100
100
100
100
100
100
81%
83%
87%
88%
86%
88%
89%
86%
85%
88%
82%
83%
86%
80%
1.13
1.62
1.33
1.69
2.42
1.77
2.26
3.23
2.60
3.33
4.72
2.20
HES063ZC-A
2.1
NOTES:
*
Maximum input current at minimum input voltage, maximum rated output power.
** At nominal V , rated output.
in
Model numbers highlighted in yellow or shaded are not recommended for new designs.
MECHANICAL DRAWING
Pin
Function
Thermal Impedance
Tolerances
Inches:
.XX 0.020
.XXX 0.010
(Millimeters)
.X 0.5
.XX 0.25
1
2
3
4
5
6
-V
in
Natural Convection
15.4 °C/W
12.2 °C/W
9.3 °C/W
7.4 °C/W
6.4 °C/W
100 LFM
200 LFM
300 LFM
400 LFM
Case
On/Off
+V
-V
-Sense
in
out
Pin:
0.002
0.05
7
8
9
Trim
Note:
(Dimensions as listed unless
otherwise specified.)
Thermal impedance data is
dependent on many environmental
factors. The exact thermal
performance should be validated
for specific application.
+Sense
+V
out
REV. JUN 04, 2004
Page 2 of 3
OPTIONS
This page is offered as a reference. Consult factory for actual availability of options. When ordering
equipment options, use the following suffix information. Select preferred option(s) and add the suffix to the
model number. Ordering option examples are located below the options table.
OPTION
Negative Logic
SUFFIX
APPLICABLE SERIES
REMARKS
N
HAS, HBD, HBS, HES, HLS, HLD, LES,
QBS, QES, QLS, TES, TQD
TTL "Low" Turns Module ON
TTL "High" Turns Module OFF
Lucent-Compatible Trim
T
HAS, HBD, HBS, HES, HLS, QBS, QES,
QLS
Trim
1
2
3
IAS, LES
Enable
IAD, IAS, LES, SMS
IAS, LES
Trim and Enable
Pin Length and Heatsink Options
0.110" (2.8mm) Pin Length
Standard Pin Length is 0.180" (4.6mm)
8
9
All Leaded Models
All Leaded Models
0.150" (3.8mm) Pin Length
0.24" (6.1mm) Horizontal Heatsink
1H
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
0.24" (6.1mm) Vertical Heatsink
0.45" (11.4mm) Horizontal Heatsink
0.45" (11.4mm) Vertical Heatsink
0.95" (24.1mm) Horizontal Heatsink
0.95" (24.1mm) Vertical Heatsink
1V
2H
2V
3H
3V
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
Example Options:
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president
of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
REV. JUN 04, 2004
Page 3 of 3