HN15-4.5-AN [BEL]

AC-DC Regulated Power Supply Module, 1 Output, Hybrid, MODULE-7;
HN15-4.5-AN
型号: HN15-4.5-AN
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

AC-DC Regulated Power Supply Module, 1 Output, Hybrid, MODULE-7

文件: 总9页 (文件大小:834K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Linear Power Supplies Data Sheet  
Features  
Worldwide AC Input Capabilities:  
100/120/220/230/240 VAC  
±0.05% Output Regulation  
Low Output Ripple  
UL, CSA, and TÜV Approvals  
Mean Time Before Failure (MTBF) in Excess of  
300,000 Hours  
CE marked to Low Voltage Directive  
100% Burn-In  
2 Year Warranty  
Overvoltage Protection (OVP) Standard on 5V  
Single Outputs, Optional for other outputs under 48V  
Description  
Power-One produces the industry’s broadest selection of The Linear power supplies are approved to domestic and  
Linear power supplies with output voltages from 5 volts international regulatory standards, and are CE Marked to  
through 250 volts. Rugged technology and proven design the Low Voltage Directive (LVD).  
merge to create quiet, highly-regulated, dependable DC  
power.  
Overvoltage Protection Options  
OVERVOLTAGE PROTECTION OPTIONS  
These optional overvoltage protection modules are offered for use with  
OVP SELECTION GUIDE  
MODEL  
CASE SIZE  
OVP MODULES REQUIRED  
Power-One’s Linear power supplies. Each is user adjustable from 6.4V to 34V.  
B,C,N,D  
(1) OVP-12  
SINGLE  
OUTPUT  
E,F  
AA,B,BB,CC  
E
(1) OVP-24  
OVP-12  
(1) OVP-12 protects both outputs  
(1) OVP-24 protects both outputs  
DUAL  
OUTPUT  
AA,BAA,D  
CBB, 131  
DBB,DCC  
(1) OVP-12 protects both 12V  
through 15V outputs  
TRIPLE  
OUTPUT  
N,BAA,CBB  
131, CP340-A  
CP510-A  
PEAK  
CURRENT  
MODELS  
(1) OVP-12 protects any output  
not provided with built-in OVP  
NOTE: Outputs with factory built-in OVP are indicated in the Voltage/Current Rating  
Chart for each model. OVP is not available for 48V through 250V models.  
OVP-24  
REV. JAN 16, 2006  
Page 1 of 9  
www.power-one.com  
Linear Power Supplies Data Sheet  
Case  
Type  
Dimensions  
(Inches)  
Unsigned output voltages are isolated and can be used as either + or - polarities.  
AA  
6.50 x 4.00 x 2.10  
4.87 x 4.00 x 2.10  
10.25 x 4.00 x 2.95  
7.00 x 4.87 x 2.95  
5.62 x 4.87 x 2.95  
11.00 x 4.87 x 3.28  
9.38 x 4.87 x 3.28  
11.00 x 4.87 x 3.28  
Output  
Voltage  
(VDC)  
Output  
Current  
(Amps)  
Model  
(Input Voltage  
of 100 to 240VAC)  
B
Additional  
Features & Notes  
Case  
Type  
BAA  
BB  
Single Output Models- 5V to 48Vout  
5
C
1.5  
3
HA5-1.5/OVP-A  
HB5-3/OVP-A  
HC5-6/OVP-A  
HN5-9/OVP-A  
HD5-12/OVP-A  
HE5-18/OVP-A  
F5-25/OVP-A  
G5-35/OVP-A  
CP197-A  
B
B
C
N
D
E
F
A
CBB  
CC  
5
A, C  
5
6
A, C  
CP131  
5
9
A, C  
CP510-A 8.25 x 4.87 x 3.28  
5
12  
18  
25  
35  
50  
1.7  
3.4  
5.1  
6.8  
10.2  
0.9  
16  
1.5  
3
A, C  
D
9.00 x 4.87 x 3.28  
14.25 x 4.87 x 3.38  
15.00 x 4.88 x 4.55  
14.00 x 4.87 x 3.53  
16.75 x 4.88 x 5.00  
7.00 x 4.87 x 3.28  
5
A, C  
DBB  
DCC  
E
5
A, C, D, H  
5
F
A, C, D, H  
5
F
A, C, D  
F
12  
HB12-1.7-A  
HC12-3.4-A  
HN12-5.1-A  
HD12-6.8-A  
HE12-10.2-A  
HA15-0.9-A  
F15-15-A  
B
C
N
D
E
B
F
C
C
C
C
C
N
12  
Case  
Type  
AA  
Dimensions  
(Millimeters)  
12  
12  
165.10 x 101.60 x 53.34  
123.70 x 101.60 x 53.34  
260.35 x 101.60 x 74.93  
177.80 x 123.70 x 74.93  
142.75 x 123.70 x 74.93  
279.40 x 123.70 x 83.31  
238.25 x 123.70 x 83.31  
279.40 x 123.70 x 83.31  
12  
B
12 to 15  
12 to 15  
15  
BAA  
BB  
C, D, H  
HB15-1.5-A  
HC15-3-A  
B
C
N
D
E
B
C
N
D
E
B
F
C
C
C
C
C
C
C
C
C
C
C
15  
CBB  
CC  
15  
4.5  
6
HN15-4.5-A  
HD15-6-A  
15  
CP131  
15  
9
HE15-9-A  
CP510-A 209.55 x 123.70 x 83.31  
24  
1.2  
2.4  
3.6  
4.8  
7.2  
0.5  
12  
1
HB24-1.2-A  
HC24-2.4-A  
HN24-3.6-A  
HD24-4.8-A  
HE24-7.2-A  
HA24-0.5-A  
F24-12-A  
D
228.60 x 123.70 x 83.31  
361.95 x 123.70 x 85.85  
381.00 x 123.95 x 115.57  
355.60 x 123.70 x 89.66  
425.50 x 123.95 x 127.00  
177.80 x 123.70 x 83.31  
24  
DBB  
DCC  
E
24  
24  
24  
F
24 to 28  
24 to 28  
28  
N
C, D, H  
HB28-1-A  
B
C
N
D
E
B
C
D
E
C
C
C
C
C
(See Additional Features Column)  
28  
2
HC28-2-A  
A
B
C
D
Overvoltage protection, set at 6.2 V 0.4 V.  
Non-adjustable 3-terminal regulator.  
Remote sense provided.  
28  
3
HN28-3-A  
28  
4
HD28-4-A  
With output inhibit and parallel  
28  
6
HE28-6-A  
operation master/slave capability.  
48  
0.5  
1
HB48-0.5-A  
HC48-1-A  
E
F
G
With output inhibit.  
Adjustable 3-terminal regulator.  
48  
Can be made into an isolated output by  
48  
3
HD48-3-A  
C
C
removing jumper W1.  
48  
4
HE48-4-A  
H
Model requires 100 LFM forced-air  
cooling above 75% of rated output  
power at 50 degrees C.  
REV. JAN 16, 2006  
Page 2 of 9  
www.power-one.com  
Dual-Output Models  
Linear Power Supplies Data Sheet  
Unsigned output voltages are isolated and can be used as either + or - polarities.  
Case  
Type  
AA  
Dimensions  
(Inches)  
Output  
Voltage  
(VDC)  
Output  
Current  
(Amps)  
Model  
(Input Voltage  
of 100 to 240VAC)  
6.50 x 4.00 x 2.10  
4.87 x 4.00 x 2.10  
10.25 x 4.00 x 2.95  
7.00 x 4.87 x 2.95  
5.62 x 4.87 x 2.95  
11.00 x 4.87 x 3.28  
9.38 x 4.87 x 3.28  
11.00 x 4.87 x 3.28  
Additional  
Features & Notes  
Case  
Type  
B
BAA  
BB  
Dual Output Models- 5V to 15Vout  
+5, –5  
1.5, 1.5  
3, 3  
HAA5-1.5/OVP-A  
HBB5-3/OVP-A  
HCC5-6/OVP-A  
CP323-A  
AA  
BB  
CC  
N
A
C
+5, –5  
A
CBB  
CC  
+5, –5  
6, 6  
A, C  
A, E  
A
+5, +12  
2, 4  
CP131  
+5, +12  
6, 2.5  
2, 0.5  
3, 1.25  
6, 2.5  
1, 0.4  
1.7, 0.7  
0.4, 0.4  
1, 1  
CP510-A  
CP510-A  
AA  
BB  
CC  
AA  
BB  
B
CP510-A 8.25 x 4.87 x 3.28  
5, 12 to 15  
5, 12 to 15  
5, 12 to 15  
+12, –5  
HAA512-A  
A, C  
A, C  
A, C  
C
D
9.00 x 4.87 x 3.28  
14.25 x 4.87 x 3.38  
15.00 x 4.88 x 4.55  
14.00 x 4.87 x 3.53  
16.75 x 4.88 x 5.00  
7.00 x 4.87 x 3.28  
HBB512-A  
DBB  
DCC  
E
HCC512-A  
HAA15-0.8-A  
HBB15-1.5-A  
HAD12-0.4-A  
HAA15-0.8-A  
HBB15-1.5-A  
HCC15-3-A  
HDD15-5-A  
HAA15-0.8-A  
HBB15-1.5-A  
HCC15-3-A  
HDD15-5-A  
HAA15-0.8-A  
HBB15-1.5-A  
HAA15-0.8-A  
HBB15-1.5-A  
HCC15-3-A  
HDD15-5-A  
+12, –5  
C
F
+12, –12  
+12, –12  
+12, –12  
+12, –12  
+12, –12  
+12, –15  
+12, –15  
+12, –15  
+12, –15  
+15, –5  
B
N
AA  
BB  
CC  
E
C
1.7, 1.7  
3.4, 3.4  
5, 5  
C
Case  
Type  
AA  
Dimensions  
(Millimeters)  
C
165.10 x 101.60 x 53.34  
123.70 x 101.60 x 53.34  
260.35 x 101.60 x 74.93  
177.80 x 123.70 x 74.93  
142.75 x 123.70 x 74.93  
279.40 x 123.70 x 83.31  
238.25 x 123.70 x 83.31  
279.40 x 123.70 x 83.31  
C
B
1, 0.8  
1.7, 1.5  
3.4, 3  
5, 5  
AA  
BB  
CC  
E
C
BAA  
BB  
C
C
C
C
CBB  
CC  
0.8, 0.4  
1.5, 0.7  
0.8, 1  
1.5, 1.7  
3, 3.4  
5, 5  
AA  
BB  
AA  
BB  
CC  
E
C
+15, –5  
C
CP131  
+15, –12  
+15, –12  
+15, –12  
15, –12  
C
CP510-A 209.55 x 123.70 x 83.31  
C
D
228.60 x 123.70 x 83.31  
361.95 x 123.70 x 85.85  
381.00 x 123.95 x 115.57  
355.60 x 123.70 x 89.66  
425.50 x 123.95 x 127.00  
177.80 x 123.70 x 83.31  
C
DBB  
DCC  
E
C
Dual Output Models- 15V to 24Vout  
+15, –15  
0.4, 0.4  
0.8, 0.8  
1.5, 1.5  
3, 3  
HAD15-0.4-A  
HAA15-0.8-A  
HBB15-1.5-A  
HCC15-3-A  
B
B
C
C
C
C
F
+15, –15  
AA  
BB  
CC  
E
N
+15, –15  
+15, –15  
(See Additional Features Column)  
+15, –15  
5, 5  
HDD15-5-A  
A
B
C
D
Overvoltage protection, set at 6.2 V 0.4 V.  
Non-adjustable 3-terminal regulator.  
Remote sense provided.  
+18 to +20, –18 to –20  
+18 to +20, –18 to –20  
+18 to +20, –18 to –20  
+18 to +20, –24  
+18 to +20, –24  
+18 to +20, –24  
+24, –18 to –20  
+24, –18 to –20  
+24, –18 to –20  
+24, –24  
0.4, 0.4  
0.9, 0.9  
1.8, 1.8  
0.4, 0.6  
0.9, 1.2  
1.8, 2.4  
0.6, 0.4  
1.2, 0.9  
2.4, 1.8  
0.6, 0.6  
1.2, 1.2  
2.4, 2.4  
HAA24-0.6-A  
HBB24-1.2-A  
HCC24-2.4-A  
HAA24-0.6-A  
HBB24-1.2-A  
HCC24-2.4-A  
HAA24-0.6-A  
HBB24-1.2-A  
HCC24-2.4-A  
HAA24-0.6-A  
HBB24-1.2-A  
HCC24-2.4-A  
AA  
BB  
CC  
AA  
BB  
CC  
AA  
BB  
CC  
AA  
BB  
CC  
With output inhibit and parallel  
C
C
C
C
operation master/slave capability.  
E
F
G
With output inhibit.  
Adjustable 3-terminal regulator.  
Can be made into an isolated output by  
removing jumper W1.  
H
Model requires 100 LFM forced-air  
cooling above 75% of rated output  
power at 50 degrees C.  
+24, –24  
+24, –24  
Model numbers highlighted in yellow or shaded are not recommended for new designs.  
REV. JAN 16, 2006  
Page 3 of 9  
www.power-one.com  
Linear Power Supplies Data Sheet  
Unsigned output voltages are isolated and can be used as either + or - polarities.  
Case  
Type  
AA  
Dimensions  
(Inches)  
Output  
Voltage  
(VDC)  
Output  
Current  
(Amps)  
Model (Input  
Voltage of  
Additional Features)  
& Notes  
Case  
Type  
6.50 x 4.00 x 2.10  
4.87 x 4.00 x 2.10  
10.25 x 4.00 x 2.95  
7.00 x 4.87 x 2.95  
5.62 x 4.87 x 2.95  
11.00 x 4.87 x 3.28  
9.38 x 4.87 x 3.28  
11.00 x 4.87 x 3.28  
100 to 240VAC)  
B
Triple Output Models- 5V to 24Vout  
+5, –5, 24  
BAA  
BB  
6, 1.2, 3.5  
CP379-A  
CP131  
BAA  
A, C, F, G  
A, C  
A, C  
A, C, F  
A, C  
A, C  
A
5, +12, –5  
3, 1, 0.4  
HBAA-40W-A  
HCAA-60W-A  
CP498-A  
C
+5, +12 to +15, –5  
+5, +12, 5  
6, 1, 0.4  
D
CBB  
CC  
6, 5, 0.25  
8, 1.7, 0.7  
12, 1.7, 0.7  
2, 0.4, 0.4  
6, 1.7, 0.7  
3, 1, 1  
CP131  
CP131  
DBB  
AA  
5, +12, –5  
CP131-A  
CP131  
5, +12, –5  
HDBB-105W-A  
HTAA-16W-A  
HCBB-75W-A  
HBAA-40W-A  
HCAA-60W-A  
CP498-A  
CP510-A 8.25 x 4.87 x 3.28  
5, +12 to +15, –5  
5, +12, –5  
D
9.00 x 4.87 x 3.28  
14.25 x 4.87 x 3.38  
15.00 x 4.88 x 4.55  
14.00 x 4.87 x 3.53  
16.75 x 4.88 x 5.00  
7.00 x 4.87 x 3.28  
CBB  
C
DBB  
DCC  
E
5, +12, –12  
+5, +12 to +15, –12 to –15  
+5, +12, 12  
5, +12, –12  
5, +12, –12  
5, +12, –12  
5, +12 to +15, –12 to –15  
5, +12, –12  
5, +12, –15  
5, +12, –15  
5, +12, –15  
5, +12, –15  
5, +12, –15  
+5, –12, 24  
5, +15, –5  
BAA  
A, C  
A, C  
A, C, F  
C
6, 1, 1  
D
6, 5, 0.5  
CP131  
CBB  
F
6, 1.7, 1.7  
8, 1.7, 1.7  
12, 1.7, 1.7  
2, 0.4, 0.4  
12, 3.4, 3.4  
3, 1, 0.8  
HCBB-75W-A  
CP131-A  
N
CP131  
DBB  
AA  
A, C  
C
HDBB-105W-A  
HTAA-16W-A  
HDCC-150W-A  
HBAA-40W-A  
HCBB-75W-A  
CP131-A  
Case  
Type  
AA  
Dimensions  
(Millimeters)  
A
165.10 x 101.60 x 53.34  
123.70 x 101.60 x 53.34  
260.35 x 101.60 x 74.93  
177.80 x 123.70 x 74.93  
142.75 x 123.70 x 74.93  
279.40 x 123.70 x 83.31  
238.25 x 123.70 x 83.31  
279.40 x 123.70 x 83.31  
DCC  
BAA  
A, C  
A, C  
C
B
BAA  
BB  
6, 1.7, 1.5  
8, 1.7, 1.5  
12, 1.7, 1.5  
12, 3.4, 3  
6, 1.2, 3.5  
3, 0.8, 0.4  
6, 1.5, 0.7  
8, 1.5, 0.7  
12, 1.5, 0.7  
3, 0.8, 1  
CBB  
CP131  
DBB  
DCC  
CP131  
BAA  
A, C  
C
C
HDBB-105W-A  
HDCC-150W-A  
CP379-A  
CBB  
CC  
A, C  
A, C, F, G  
A, C  
C
CP131  
HBAA-40W-A  
HCBB-75W-A  
CP131-A  
CP510-A 209.55 x 123.70 x 83.31  
5, +15, –5  
CBB  
D
228.60 x 123.70 x 83.31  
361.95 x 123.70 x 85.85  
381.00 x 123.95 x 115.57  
355.60 x 123.70 x 89.66  
425.50 x 123.95 x 127.00  
177.80 x 123.70 x 83.31  
5, +15, –5  
CP131  
DBB  
BAA  
A,  
DBB  
DCC  
E
5, +15, –5  
HDBB-105W-A  
HBAA-40W-A  
HCBB-75W-A  
CP131-A  
C
5, +15, –12  
5, +15, –12  
5, +15, –12  
5, +15, –12  
5, +15, –12  
5, +15, –15  
5, +15, –15  
5, +15, –15  
5, +15, –15  
5, +15, –15  
A, C  
C
6, 1.5, 1.7  
8, 1.5, 1.7  
12, 1.5, 1.7  
12, 3, 3.4  
3, 0.8, 0.8  
6, 1.5, 1.5  
8, 1.5, 1.5  
12, 1.5, 1.5  
12, 3, 3  
CBB  
F
CP131  
DBB  
DCC  
BAA  
A, C  
C
N
HDBB-105W-A  
HDCC-150W-A  
HBAA-40W-A  
HCBB-75W-A  
CP131-A  
A, C  
A, C  
C
(See Additional Features Column)  
A
B
C
D
Overvoltage protection, set at 6.2 V 0.4 V.  
Non-adjustable 3-terminal regulator.  
Remote sense provided.  
CBB  
CP131  
DBB  
DCC  
A, C  
C
With output inhibit and parallel  
HDBB-105W-A  
HDCC-150W-A  
operation master/slave capability.  
A, C  
E
F
G
With output inhibit.  
Adjustable 3-terminal regulator.  
Quad Output Models- 5V to 24Vout Models  
+5, +12, –5, +24  
Can be made into an isolated output by  
6, 1, 0.5, 2.4  
CP503-A  
CP503-A  
CP131  
CP131  
A, H  
A, H  
removing jumper W1.  
+5, +12, –12, +24  
6, 1, 1, 2.4  
H
Model requires 100 LFM forced-air  
cooling above 75% of rated output  
power at 50 degrees C.  
Model numbers highlighted in yellow or shaded are not recommended for new designs.  
REV. JAN 16, 2006  
Page 4 of 9  
www.power-one.com  
Linear Power Supplies Data Sheet  
Input Specifications  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Input Voltage - AC  
(Note 1, 2)  
Jumper selectable, shipped factory configured for  
120VAC operation. All models must be externally  
fused for proper operation. Fuse ratings are marked  
on each unit. Consult factory for each unit’s fuse  
requirements.  
100 VAC Tap  
120 VAC Tap  
220 VAC Tap  
240 VAC Tap  
87  
100  
120  
220  
240  
110  
132  
242  
264  
104  
191  
209  
VAC  
Input Frequency  
Line Regulation  
AC input.  
47  
-0.01  
-1.0  
-0.5  
-0.05  
63  
+0.01  
+1.0  
+0.5  
+0.05  
Hz  
%
Output voltage charge for a 10% line change: F case models.  
HAD12, HAD15.  
Outputs with adjustable three terminal regulators.  
All other models.  
NOTES: 1) Derate output current 10% for 50Hz operation.  
2) Input voltage tolerance for 230VAC operation is +15%, -10%.  
Output Specifications  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Output Adjustment  
Efficiency  
Minimum output adjustment range (Note 1).  
5 volt outputs.  
12 volt and 15 volt outputs.  
24 volt and higher outputs.  
-5  
+5  
%
45  
55  
60  
%
F case models.  
3.0  
5.0  
0.2  
mVPK-PK  
mVPK-PK  
%PK-PK  
Ripple and Noise  
(Note 2)  
5 volt, 12 volt, and 15 volt models.  
All three terminal regulator outputs.  
24 volt through 250 volt models.  
3.0mVPK-PK plus 0.02% of output voltage, max  
Load Regulation  
Output change for a 50% load change: F case models.  
HAD12, HAD15.  
-0.02  
-1  
+0.02  
+1  
%
Outputs with adjustable three terminal regulators.  
All other models.  
-0.5  
-0.05  
+0.5  
+0.05  
Transient Response  
Recovery time, to within 1% of initial set point due to a 50% load change.  
50  
μs  
NOTES: 1) OUTPUT VOLTAGE ADJUSTMENTS: Output voltage adjustments can be made to within ±5% of nominal voltage. Locate the “Vadj” potentiometer on the power  
supply PCB and use a screwdriver to adjust the output pot. The HAD12 and HAD15 3-terminal regulator outputs are not adjustable.  
2) Full load, 20MHz bandwidth.  
Safety, Regulatory, and EMI Specifications  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Agency Approvals  
UL60950 3rd Edition.  
CSA 60950 3rd Edition.  
EN60950 3rd Edition.  
IEC60950 3rd Edition  
Approved  
Dielectric Withstand  
Voltage  
Input to output.  
Input to ground.  
3750  
3750  
VRMS  
Electromagnetic  
Interference  
FCC CFR title 47 Part 15 Sub-Part B - conducted.  
EN55022 / CISPR 22 conducted.  
EN55022 / CISPR 22 radiated.  
Compatible with system compliance to Level B.  
Leakage Current  
Per EN60950  
(264VAC)  
23  
50  
μA  
Interface Signals and Internal Protection  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Overvoltage Protection  
Provided on 5 volt output units where indicated.  
Other outputs may use optional overvoltage protectors OVP-12 and OVP-24.  
5.8  
6.6  
V
Remote Sense  
Total voltage compensation for cable losses with respect to the main output.  
Provided on models where indicated.  
250  
mV  
Overcurrent/Short Circuit  
Protection  
Automatic current limit/foldback. Rated as a percentage of output power.  
115  
120  
140  
%
Master/Slave Operation  
For parallel operation of up to 6 units. Master/slave pin provided on F case models only. Contact factory for application notes.  
REV. JAN 16, 2006  
Page 5 of 9  
www.power-one.com  
Linear Power Supplies Data Sheet  
Environmental Specifications  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Operating Temperature  
Derate output power linearly above 50°C by 3% per °C.  
At 100% load  
At 40% load  
0
50  
70  
°C  
°C  
Storage Temperature  
-40  
85  
°C  
Temperature Coefficient  
0°C to 50°C (after 15 minute warm-up).  
24 hours after warm-up.  
0.1  
0.3  
+0.3  
%/°C  
%
-0.3  
Shock  
Vibration  
Relative Humidity  
Operating.  
20  
6.15  
95  
GPK  
GRMS  
%RH  
Random vibration from 10 Hz to 2 kHz, 3 axis.  
Non-Condensing.  
5
REV. JAN 16, 2006  
Page 6 of 9  
www.power-one.com  
Linear Power Supplies Data Sheet  
REV. JAN 16, 2006  
Page 7 of 9  
www.power-one.com  
Linear Power Supplies Data Sheet  
REV. JAN 16, 2006  
Page 8 of 9  
www.power-one.com  
Linear Power Supplies Data Sheet  
NUCLEAR AND MEDICALAPPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components  
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective  
divisional president of Power-One, Inc.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the  
date manufactured. Specifications are subject to change without notice.  
REV. JAN 16, 2006  
Page 9 of 9  
www.power-one.com  

相关型号:

HN15100000J0G

Barrier Strip Terminal Block
AMPHENOL

HN15102000J0G

Barrier Strip Terminal Block
AMPHENOL

HN15102200J0G

Barrier Strip Terminal Block
AMPHENOL

HN15103000J0G

Barrier Strip Terminal Block
AMPHENOL

HN15103200J0G

Barrier Strip Terminal Block
AMPHENOL

HN15104000J0G

Barrier Strip Terminal Block
AMPHENOL

HN15104200J0G

Barrier Strip Terminal Block
AMPHENOL

HN15105000J0G

Barrier Strip Terminal Block
AMPHENOL

HN15105200J0G

Barrier Strip Terminal Block
AMPHENOL

HN15106200J0G

Barrier Strip Terminal Block
AMPHENOL

HN15108000J0G

Barrier Strip Terminal Block
AMPHENOL

HN15108200J0G

Barrier Strip Terminal Block
AMPHENOL