HR2320-9RG [BEL]

DC-DC Regulated Power Supply Module,;
HR2320-9RG
型号: HR2320-9RG
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

DC-DC Regulated Power Supply Module,

文件: 总27页 (文件大小:5144K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
HR / ER Series  
144 / 288 Watt 10:1 DC-DC Converters  
The ER/HR Series of DC-DC converters represents versatile  
power supplies ideally suitable for use in transportation and  
other advanced electronic systems.  
The HR Series converters include a very broad input voltage  
range, very high efficiency, high reliability, low output voltage  
noise, and excellent dynamic response to load/line changes.  
HR converters can be connected to all conventional railway  
batteries.  
ER Series converters are optimized for connection to 110 V  
railway batteries.  
111  
4.4ꢀ  
3 U  
Features  
• Extremely wide input voltage range from 12 to 168 VDC  
in the same converter (HR Series)  
• RoHS-compliant for all 6 substances  
• Class I equipment  
60  
2.4ꢀ  
12 TE  
168  
6.6ꢀ  
• Compliant with EN 50155, EN 50121, EN 45545  
• Input over- and programmable undervoltage lockout  
• Shutdown function  
• Inrush current limitation  
• Interruption time 10 ms  
• Adjustable output voltages  
• 2 isolated outputs: no load, overload, and short-circuit proof  
• Rectangular current limiting characteristic  
• Parallel operation with active current sharing  
Very high efficiency up to 94%  
Immunity according to IEC 61000-4-2, -3, -4, -5, -6, -8, -9  
• All PCB boards protected by lacquer  
• Very high reliability  
111  
4.4ꢀ  
3 U  
• 5 year warranty  
80  
3.2ꢀ  
16 TE  
168  
6.6ꢀ  
Safety-approved to the latest edition of IEC/EN 60950-1  
and UL/CSA 60950-1  
Table of Contents  
Description........................................................................................1  
Model Selection................................................................................2  
Functional Description......................................................................5  
Electrical Input Data .........................................................................7  
Electrical Output Data.....................................................................10  
Auxiliary Functions .........................................................................15  
Electromagnetic Compatibility (EMC).............................................18  
Immunity to Environmental Conditions...........................................20  
Mechanical Data.............................................................................21  
Safety and Installation Instructions.................................................24  
Description of Options....................................................................25  
Accessories....................................................................................26  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
Description  
The converter inputs are protected against surges and transients. An input over- and undervoltage lockout circuitry disables  
the outputs, when the input voltage is outside of the specified range. To avoid high input currents at operation with high-voltage  
batteries, the inhibit input allows for adjusting the undervoltage lockout to a suitable level, thus allowing the use of an appropriate  
external input fuse.  
The converters exhibit an inrush current limiter, preventing external circuit breakers and fuses from tripping at switch-on.  
The outputs are open- and short-circuit proof.  
Full input-to-output, input-to-case, output-to-case, and output to output isolation is provided. The converters are particularly suitable  
for railway applications. The HR converters can be supplied by all common railway batteries with 24 V, 36 V, 48 V, 72 V, 96 V, 110 V,  
and 120 V nominal voltage. All PCB boards are coated with a protective lacquer.  
The case design allows operation at nominal load up to 71 °C with natural cooling. If forced cooling is provided, the ambient  
temperature may exceed 71 °C, but the case temperature must remain below 95 °C.  
A temperature sensor disables the outputs when the case temperature TC exceeds the limit. The outputs are automatically re-  
enabled, when the temperature drops below the limit.  
LED indicators display the status of the converter and allow for visual monitoring of the system at any time.  
The converters may either be plugged into a 19rack system according to IEC 60297-3, or be chassis mounted. Two heat sinks  
of different size and cooling plates for chassis mounting (option B, B1) are available.  
Model Selection  
Table 1a: Model Selection of HR models  
Output 1  
Output 2  
Power  
Input voltage  
Efficiency  
Model  
Options  
1
2
η24  
η110  
min typ  
3
3
Vo nom  
Io nom  
Vo nom  
Io nom  
Po nom  
Vi min  
Vi cont  
Vi max  
min  
[%]  
typ  
[V]  
[A]  
[V]  
[A]  
[W]  
[V]  
[V]  
[V]  
[%]  
[%]  
[%]  
12  
12  
12  
15  
15  
48  
48  
20  
12  
24  
16  
19.2  
4
-
-
-
-
-
-
-
-
-
-
-
-
-
-
240  
144  
288  
240  
288  
192  
240  
12  
12  
12  
12  
12  
12  
12  
16.8 to 150  
16.8 to 150  
16.8 to 150  
16.8 to 150  
16.8 to 150  
16.8 to 150  
16.8 to 150  
168  
168  
168  
168  
168  
168  
168  
91  
91  
91  
91  
91  
92.5  
92.5  
92.5  
92.5  
92.5  
90.5  
90.5  
92  
92  
92  
92  
92  
92  
92  
94  
94  
94  
94  
94  
93  
93  
HR2320-9RG 4  
HRL2320-9RG 4  
HRP2320-9RG 4  
HR2540-9RG 4  
HRP2540-9RG 4  
HR2880-9RG 4  
HRP2880-9RG 4  
B, B1  
B, B1  
B, B1  
89.5  
89.5  
5
12  
12  
12  
15  
15  
48  
48  
10  
6
12  
12  
12  
15  
15  
48  
48  
10  
6
240  
144  
288  
240  
288  
192  
240  
12  
12  
12  
12  
12  
12  
12  
16.8 to 150  
16.8 to 150  
16.8 to 150  
16.8 to 150  
16.8 to 150  
16.8 to 150  
16.8 to 150  
168  
168  
168  
168  
168  
168  
168  
91  
91  
92.5  
92.5  
92.5  
92.5  
92.5  
90.5  
90.5  
92  
92  
92  
92  
92  
92  
92  
94  
94  
94  
94  
94  
93  
93  
HR2320-9RG  
HRL2320-9RG  
HRP2320-9RG  
HR2540-9RG  
HRP2540-9RG  
HR2880-9RG  
HRP2880-9RG  
12  
8
12  
8
91  
91  
9.6  
2
9.6  
2
90  
89.5  
89.5  
2.5  
2.5  
24  
24  
24  
30  
30  
96  
96  
10  
6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
240  
144  
288  
240  
288  
192  
240  
12  
12  
12  
12  
12  
12  
12  
16.8 to 150  
16.8 to 150  
16.8 to 150  
16.8 to 150  
16.8 to 150  
16.8 to 150  
16.8 to 150  
168  
168  
168  
168  
168  
168  
168  
91  
91  
92.5  
92.5  
92.5  
92.5  
92.5  
90.5  
90.5  
92  
92  
92  
92  
92  
92  
92  
94  
94  
94  
94  
94  
93  
93  
HR2320-9RG 5  
HRL2320-9RG 5  
HRP2320-9RG 5  
HR2540-9RG 5  
HRP2540-9RG 5  
HR2880-9RG 5  
HRP2880-9RG 5  
12  
8
91  
91  
9.6  
2
91  
89.5  
89.5  
2.5  
1
2
3
4
5
Efficiency at TA = 25 °C, Vi = 24 V, Io nom, Vo nom  
Efficiency at TA = 25 °C, Vi = 110 V, Io nom, Vo nom  
Short time; see table 2 for details  
Both outputs connected in parallel  
Both outputs connected in series  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 2 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
Table 1b: Model Selection of ER models  
Output 1  
Output 2  
Power  
Input voltage  
Efficiency  
Model  
Options  
1
η110  
2
2
Vo nom  
Io nom  
Vo nom  
Io nom  
Po nom  
Vi min  
Vi cont  
Vi max  
min  
[%]  
typ  
[V]  
[A]  
[V]  
[A]  
[W]  
[V]  
[V]  
[V]  
[%]  
12  
12  
12  
15  
15  
48  
48  
20  
12  
24  
16  
19.2  
4
-
-
-
-
-
-
-
-
-
-
-
-
-
-
240  
144  
288  
240  
288  
192  
240  
66  
66  
66  
66  
66  
66  
66  
77 to 150  
77 to 150  
77 to 150  
77 to 150  
77 to 150  
77 to 150  
77 to 150  
168  
168  
168  
168  
168  
168  
168  
93  
94  
ER2320-9RG 3  
ERL2320-9RG 3  
ERP2320-9RG 3  
ER2540-9RG 3  
ERP2540-9RG 3  
ER2880-9RG 3  
ERP2880-9RG 3  
91  
94  
B, B1  
B, B1  
B, B1  
90.5  
92  
5
12  
12  
12  
15  
15  
48  
48  
10  
6
12  
12  
12  
15  
15  
48  
48  
10  
6
240  
144  
288  
240  
288  
192  
240  
66  
66  
66  
66  
66  
66  
66  
77 to 150  
77 to 150  
77 to 150  
77 to 150  
77 to 150  
77 to 150  
77 to 150  
168  
168  
168  
168  
168  
168  
168  
93  
91  
94  
94  
ER2320-9RG  
ERL2320-9RG  
ERP2320-9RG  
ER2540-9RG  
ERP2540-9RG  
ER2880-9RG  
EHRP2880-9RG  
12  
8
12  
8
9.6  
2
9.6  
2
90.5  
92  
2.5  
2.5  
24  
24  
24  
30  
30  
96  
96  
10  
6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
240  
144  
288  
240  
288  
192  
240  
66  
66  
66  
66  
66  
66  
66  
77 to 150  
77 to 150  
77 to 150  
77 to 150  
77 to 150  
77 to 150  
77 to 150  
168  
168  
168  
168  
168  
168  
168  
93  
91  
94  
94  
ER2320-9RG 4  
ERL2320-9RG 4  
ERP2320-9RG 4  
ER2540-9RG 4  
ERP2540-9RG 4  
ER2880-9RG 4  
ERP2880-9RG 4  
12  
8
9.6  
2
90.5  
92  
2.5  
1
2
3
4
Efficiency at TA = 25 °C, Vi = 110 V, Io nom, Vo nom  
Short time; see table 2 for details  
Both outputs connected in parallel  
Both outputs connected in series  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 3 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
Part Number Description  
HR 2 5 40 -9 R B1 G  
Operating input voltage Vi cont (continuously):  
16.8150 VDC .....................................HR, HRL, HRP  
77150 VDC ..........................................ER, ERL, ERP  
Number of outputs.......................................................... 2, 72  
Nominal voltage of main output Vo1 nom  
12 V .............................................................................3  
15 V .............................................................................5  
24 V .............................................................................6  
36 V .............................................................................7  
48 V .............................................................................8  
Other voltages1 ...........................................................9  
3
Nominal voltage of tracking output Vo2  
12 V.............................................................................20  
15 V.............................................................................40  
24 V.............................................................................60  
36 V.............................................................................70  
48 V.............................................................................80  
Other specifications or additional features1 ....... 2199  
Operational temperature range: TA:  
TA = 40 to 71 °C, TC 95 °C ......................................-9  
Other1 ...............................................................-0, -5, -6  
Auxiliary functions and options:  
Output voltage control input ....................................... R  
Cooling plate standard case...................................B, B1  
Cooling plate for long case 220 mm2 .......................B22  
RoHS-compliant for all 6 substances ......................... G4  
1
Customer-specific models. No safety-relevant changes compared to the respective basic model, e.g. different mechanical details, special  
markings, mounted front plates, reduced output voltage, etc.  
Converters with 220 mm case (customer-specific models). Add 5000 to the model number, e.g. HR2540-9RB1G → HR7540-9RB1G.  
The nominal voltages of both outputs are always equal.  
2
3
4
G is always placed at the end of the part number.  
Note: The sequence of options must follow the order above.  
Example: HR2540-9RB1G: DC-DC converter, operating input voltage range 16.8 – 150 VDC, 2 isolated outputs, each providing  
15 V, 8 A, control input R to adjust the output voltages, cooling plate B1, and RoHS-compliant for all six substances.  
Product Marking  
Basic type designation, approval marks, CE mark, warnings, pin allocation, patents, MELCHER logo, specific type designation,  
input voltage range, nominal output voltages and output currents, degree of protection, identification of LEDs, batch no., serial no.  
and data code including production site, version, and production date.  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 4 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
Functional Description  
The input voltage is fed via an efficient filter to the interleaved switching boost converter (HR models), which provides the  
intermediate circuit voltage on the bulk capacitor Cb. The inrush current is limited by the resistor Rinr, which is shorted by Vinr after  
the bulk capacitor was charged.  
The bulk capacitor sources a single-transistor forward converter with active clamp and provides the power during the interruption  
time of 10 ms.  
The main transformer exhibits two separate secondary windings for the two outputs. The resultant voltages are rectified by  
synchronous rectifiers (not models with Vo = 2× 48 V) in order to provide the best efficiency. Their ripple voltages are smoothed by  
a dual power choke and output filters. The control logic senses the main output voltage Vo1 and generates the control signal for the  
forward converter, with respect to the max. output current transferred via magnetic feedback to the control circuit of the forward  
converter, located on the primary side.  
The second output voltage is tracking the main output, but has its own current limiting circuit. If the main output voltage drops due  
to current limitation, the second output voltage will drop as well and vice versa.  
The output voltages can be adjusted by external means. Parallel operation of several converters is possible by interconnecting  
the T-pins to provide active current sharing. Both outputs can be connected in parallel or in series without any precaution. They  
exhibit a rectangular current limitation characteristic. Switchable preloads VPL (Version V101 or later) ensure good regulation even  
with no load at one output.  
A control output (D) and two LEDs signal correct operation of the converter. In case of an output overvoltage, the converter is  
disabled by a latch.  
Input over- and undervoltage lockout is provided. The undervoltage trigger level can be adjusted by an external resistor connected  
to PUL (pin 24) depending on the nominal voltage of the supplying battery.  
Temperature sensors on the primary and secondary side prevent the converter from excessive warm-up.  
A cooling plate for chassis-mounting is available (opt. B, B1).  
ꢀM080c  
16  
R
Magnetic  
feedback  
Secondary  
control  
logic  
18T 2  
C
26  
28  
Vi+  
20  
D
Synchr.  
rect. drive  
S1+  
12  
4
1
Vo1+  
C
C
C
x
C
i
C
V
+
+
b
+
Vo1–  
8
14 S1–  
Synchr.  
rect. drive  
V
PL  
1
inr  
Primary  
control  
Vo2+  
Vo2–  
6
C
C
+
30  
32  
Vi–  
10  
PUL 24  
22  
V
PL  
C
1
Auxiliary  
converter  
(80 kHz)  
2
models with 2x 48 V have rectifier diodes  
T-pin is not connected for models HRL  
Fig. 1  
Block diagram of HR2320, version V101 (or later)  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 5 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
ꢀM157  
16  
R
Magnetic  
feedback  
Secondary  
control  
logic  
18T 2  
C
26  
28  
Vi+  
20  
D
Synchr.  
rect. drive  
S1+  
12  
4
1
Vo1+  
C
C
C
x
C
V
+
b
+
Vo1–  
8
14 S1–  
Inrush  
current  
control  
Synchr.  
rect. drive  
V
1
PL  
inr  
Vo2+  
Vo2–  
6
30  
32  
Vi–  
C
C
+
PUL 24  
22  
10  
C
Auxiliary  
converter  
(150 kHz)  
V
PL  
1
2
models with Vo = 2x 48 V have rectifier diodes  
T-pin is not connected for models HRL  
Fig. 2  
Block diagram of ER2320  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 6 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
Electrical Input Data  
General conditions:  
- TA = 25 °C, unless TC is specified.  
- Pin 24 (PUL) left open-circuit  
- Pin 16 (R) and 18 (D) left open-circuit.  
Table 2a: Input data of HR models  
Model  
HR  
HRL  
HRP  
Unit  
Characteristics  
Conditions  
min  
typ  
max  
min  
typ  
max  
min  
typ  
max  
16.8  
12.0  
24  
150  
168  
120  
176  
16.8  
12.0  
24  
150  
168  
120  
176  
9.31  
16.8  
12.0  
24  
150  
168  
120  
176  
Vi  
Operating input voltage cont.  
For ≤2 s without shutdown  
Io = 0 – Io max  
TC min TC max  
Vi 2s  
V
(110)  
(110)  
(110)  
Vi nom Nominal input voltage range  
Vi abs Input voltage limits  
HR2320  
0
0
0
3 s, without damage  
1.76  
1.76  
1.37  
(2.36) 15.65  
(2.36) 15.65  
(1.86) 12.82  
1.03  
(1.38)  
2.10  
2.10  
1.71  
(2.83) 21.40  
(2.83) 21.40  
(2.33) 16.05  
Ii  
Input current:  
HR2540  
HR2880  
Vi max ..(110 V) Vi min, Io nom  
A
..  
11  
11  
11  
Pi 0  
No-load input power  
Vi min Vi max, Io = 0  
W
2.5  
2.5  
2.5  
Pi inh Idle input power  
Vi min Vi max, VPUL = 0 V  
8.6  
10  
8.6  
10  
8.6  
10  
Cx  
Ri  
Input capacitance 1  
µF  
mΩ  
A
Input resistance  
30  
30  
30  
Iinr p  
tinr r  
ton  
Peak inrush current 2  
Time constant of Iinr  
Start-up time  
Vi = 150 V Io nom  
,
10  
10  
10  
400  
400  
400  
0Vi min, Io nom  
ms  
Vi 16.8 V Io nom,  
,
40  
40  
40  
tr  
Rise time after inhibit  
VPUL = 05 V  
Table 2b: Input data of ER models  
Model  
ER  
ERL  
ERP  
Unit  
Characteristics  
Conditions  
min  
typ  
max  
min  
typ  
max  
min  
typ  
max  
77  
66  
150  
168  
120  
176  
77  
66  
150  
168  
120  
176  
77  
66  
150  
168  
120  
176  
Vi  
Operating input voltage  
Io = 0 – Io max  
TC min TC max  
Vi 2s  
For ≤2 s without shutdown  
V
110  
110  
110  
Vi nom Nominal input voltage range  
Vi abs Input voltage limits  
ER2320  
0
0
0
3 s, without damage  
1.76  
1.76  
1.37  
(2.36)  
(2.36)  
(1.86)  
1.03  
(1.38)  
2.10  
2.10  
1.71  
(2.83)  
(2.83)  
(2.33)  
Vi max ..(110 V) Vi min, Io nom  
..  
Ii  
Input current:  
ER2540  
ER2880  
A
10  
10  
10  
Pi 0  
No-load input power  
Vi min Vi max, Io = 0  
W
2.5  
2.5  
2.5  
Pi inh Idle input power  
Vi min Vi max, VPUL = 0 V  
Cx  
Ri  
Input capacitance 1  
µF  
mΩ  
A
10  
10  
10  
Input resistance  
Iinr p  
tinr r  
ton  
Peak inrush current 2  
Time constant of Iinr  
Start-up time  
Vi = 150 V Io nom  
,
400  
40  
400  
40  
400  
40  
0Vi min, Io nom  
ms  
Vi 77 V Io nom,  
,
tr  
Rise time after inhibit  
VPUL = 05 V  
1
2
Not smoothed by the inrush current limiter  
According to ETS 300132-2  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 7 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
PUL Function and Fuse  
No fuse is incorporated in the converters. Consequently, an external fuse or a circuit breaker must be installed at system level to  
protect against severe defects.  
HR converters are designed for an extremely wide input voltage range, allowing for connection to all common railway batteries.  
However, the programmable input undervoltage lockout (PUL, pin 24) should be adjusted adequately, in order to limit the input  
current at low input voltage.  
Table 3 specifies the values of the resistor RPUL, connected between PUL and Vi–, versus the resultant minimum input voltage and  
the recommended external input fuse.  
Fig. 3 shows more values of RPUL versus start-up voltage. For stationary batteries, a higher start-up voltage might be advantageous.  
Vi min ꢀVꢁ  
ꢂM101a  
80  
60  
40  
20  
0
RPUL  
2
4
6
8
10  
12  
16  
14  
k  
Fig. 3  
RPUL versus switch-on voltage (HR models)  
ER models are designed for the input voltage range of a 110 V railway battery. The input undervoltage lockout (PUL, pin 24) may  
be adjusted if requested. The PUL resistors are specified in table 4.  
Table 3: PULSpecification (typ.)and recommended external fuses  
Table 4: PULspecification (typ.)and recommended external fuses  
forHR/HRP models.Smallerfuses are possible forHRL models.  
forER/ERP models. Smallerfuses are possible forERL models.  
Battery  
24 V  
RPUL  
Vi min (on/off) Fuse recommended  
Battery  
110 V  
110 V  
110 V  
110 V  
120 V  
RPUL  
Vi min (on/off)  
64.5 V 60.5 V 6.3 A slow, BEL fuse MRT 2  
74.5 V 69 V  
6.3 A slow, BEL fuse MRT 2  
87.4 V 81.6 V 6.3 A slow, BEL fuse MRT 2  
Fuse recommended  
15 V  
20 V  
26 V  
38 V  
62 V  
90 V  
12 V3 25 A fast, Littlefuse 314 1  
18 V 16 A fast, Schurter / SP 2  
20 V 12.5 A fast, Schurter / SP 2  
32 V 8 A fast, Schurter / SP 2  
57 V 6.3 A slow, BEL fuse MRT 2  
84 V 5.0 A slow, BEL fuse MRT 2  
5.0 kΩ  
4.0 kΩ  
3.0 kΩ  
2.5 kΩ  
36 V  
16.9 kΩ  
13.7 kΩ  
9.5 kΩ  
5.2 kΩ  
2.9 kΩ  
< 100 Ω  
48 V  
72 V  
96 V  
90 V  
96 V  
6.3 A slow, BEL fuse MRT 2  
5.0 A slow, BEL fuse MRT 2  
96 V  
2.2 kΩ 101.7 V  
110 V  
-
< 100 Ω  
Converter disabled  
1
2
fuse size 6.3 × 32 mm  
fuse size 5 × 20 mm  
all  
Converter disabled  
1
2
3
fuse size 6.3 × 32 mm  
fuse size 5 × 20 mm  
for 2 s  
Note: If PUL (pin 24) is connected to Vi– (pin 30/32), the converter is disabled; see Inhibit Function.  
Fig. 4 and 5 show the input current versus the input voltage.  
Ii ꢀAꢁ  
Ii ꢀAꢁ  
ꢂM087  
ꢂM167  
5
25  
20  
15  
4
3
2
1
10  
5
0
0
Vi ꢀVꢁ  
0
80  
100  
120  
140 Vi ꢀVꢁ  
20  
40  
60  
80  
100  
120  
140 160  
Fig. 4  
Fig. 5  
Typ. input current vs input voltage at nominal load (HR2320)  
Typ. input current vs input voltage at nominal load (ER2320)  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 8 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
Reverse Polarity and Input Transient Protection  
Reverse polarity protection of all models is provided by an antiparallel diode across the input, causing the external input fuse or  
circuit breaker to trip. ER models exhibit an additional serial diode on the input.  
The double stage symmetrical input filter together with a VDR (voltage depending resistor) form an effective protection against  
high input transient voltages, which typically occur in battery-driven mobile applications.  
At very high input voltage, the overvoltage lockout disables the converter in order to protect it from damage.  
Inrush Current Limitation  
The converters exhibit an electronic inrush current limiting circuit. This circuit is also functional, when the input voltage is removed  
and immediately reapplied.  
However, several capacitors are directly connected to the input pins. Consequently, a short current peak is present, when applying  
the input voltage.  
The inrush current peak value can be determined by following calculation; see also fig. 6:  
Vi source  
–––––––––  
=
Iinr p  
(Rext + Ri )  
I
inr ꢀAꢁ  
50  
ꢂM086  
ꢀM001c  
40  
30  
Converter  
Lext  
Rext  
Vi+  
Vo+  
Vo–  
+
Ri  
Ci  
20  
10  
0
Vi–  
0.1  
100  
200  
300  
400 ms  
Fig. 6  
Equivalent input ciruit  
Fig. 7  
Inrush current at Vi = 150 V, Io nom (HR2320, ER2320)  
Efficiency  
η ꢂꢃꢄ  
ꢁM100  
100  
V = 110 V  
i
ꢀ0  
80  
70  
V = 150 V  
i
V = 15.4 V  
i
60  
0.2  
0.6  
0.8  
0
0.4  
Io / Io nom  
Fig. 8  
Efficiency versus Vi and Io (HR2320, both outputs connected in series)  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 9 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
Electrical Output Data  
General Conditions: – TA = 25 °C, unless TC is specified; Pin 24 (PUL) 5 V  
Table 5a: Output data of HR/ER2320 and HRL/ERL2320  
Model  
HR2320 / ER2320  
2 × 12 V  
HRL2320 / ERL2320  
2 × 12 V  
Unit  
Nom. output voltage  
Output 1  
typ  
Output 2  
max min typ max min  
Output 1  
typ  
Output 2  
typ max  
Characteristics  
Conditions  
min  
max  
min  
11.93 12.0 12.07  
12.0  
11.93 12.0 12.07  
12.0  
Vo  
Vo BR  
Io  
Output voltage  
Vi nom, 0.5 Io nom  
V
A
Output protection  
(suppressor diode)  
-
14.4  
15.9  
-
14.4  
15.9  
Output 2  
10  
10.5  
10  
6.0  
6.0  
Output current nom.  
Vi min V  
i max  
Io1L, Io2L Output current limit 1  
10.5  
-
6.5  
13  
6.5  
-
TC min – TC max  
212  
Io12L  
Output current limit 1, 2  
Output noise incl. spikes  
Adjustment by R-input 4  
Vi nom, Io nom  
60  
60  
60  
60  
mVpp  
V
Vo  
BW = 20 MHz  
3
3
3
3
4.8  
13.81  
±120  
4.8  
13.81  
±120  
Vo adj  
Vo u  
Vi min V  
i max  
Static line/load regulation  
(total deviation of Vo)  
(0.1 1)Io nom  
mV  
Voltage  
deviation  
V
i nom, 0.5 Io2 nom  
Dynamic  
load  
±200  
1
±200  
±150  
1
±150  
Vo d  
to d  
5
Io1 nom 0.5 Io1 nom  
5
3
3
regulation Recovery time  
and after turn on  
ms  
Io nom,  
Temperature coefficient of  
output voltage  
±0.01 ±0.02  
-
±0.01 ±0.02  
-
%/K  
α v o  
TC min – TC max  
Table 5b: Output data of HRP/ERP2320 models  
Model  
HRP2320 / ERP2320  
2 × 12 V  
Unit  
Nom. output voltage  
Output 1  
Output 2  
max min typ max  
Characteristics  
Conditions  
min  
typ  
11.93 12.0 12.07  
12.0  
Vo  
Output voltage  
Vi nom, 0.5 Io nom  
V
A
Output protection  
(suppressor diode)  
-
14.4  
15.9  
Vo BR  
Io  
Output 2  
12  
12.3  
12  
Output current nom.  
Vi min V  
i max  
Io1L, Io2L Output current limit 1  
12.3  
-
TC min – TC max  
24.6 2  
Io12L  
Output current limit 1 2  
Output noise incl. spikes  
Adjustment by R-input 4  
Vi nom, Io nom  
60  
60  
mVpp  
V
Vo  
BW = 20 MHz  
3
3
4.8  
13.8 1  
±120  
Vo adj  
Vo u  
Vi min V  
i max  
Static line/load regulation  
(total deviation of Vo)  
(0.1 1)Io nom  
mV  
Voltage  
deviation  
Vi nom, 0.5 Io2 nom  
Dynamic  
load  
±250  
1
±250  
Vo d  
to d  
5
Io1 nom 0.5 Io1 nom  
and after turn on  
5
3
regulation Recovery time  
ms  
Io nom,  
Temperature coefficient of  
output voltage  
±0.01 ±0.02  
-
%/K  
α v o  
TC min – TC max  
1
If Vo is increased above Vo nom through R-, sense, or T-input, the output currents should be reduced so that Po nom is not exceeded.  
Both outputs connected in parallel  
See Output voltage regulation  
For battery charger application, a defined negative temp. coefficient can be provided by using a temp. sensor (see Accessories)  
See Dynamic load regulation  
Measured with a ceramic cap of 1 µF across each output.  
2
3
4
5
6
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 10 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
Table 5c: Output data of HR/ER2540 and HRP/ERP2540. General conditions as per table 5a  
Model  
HR2540 / ER2540  
2 × 15 V  
HRP2540 / ERP2540  
2 × 15 V  
Unit  
Nom. output voltage  
Output 1  
typ  
Output 2  
min typ max min  
Output 1  
typ  
Output 2  
typ max  
Characteristics  
Conditions  
min  
max  
max  
min  
14.91 15.0  
15.09  
15.0  
14.91 15.0  
15.09  
15.0  
Vo  
Vo BR  
Io  
Output voltage  
Vi nom, 0.5 Io nom  
V
A
Output protection  
(suppressor diode)  
-
20.9  
23.1  
-
20.9  
23.1  
Output 2  
8
8
9.6  
10.1  
9.6  
Output current nom.  
Vi min V  
i max  
Io1L, Io2L Output current limit 1  
8.4  
8.4  
-
10.1  
-
TC min – TC max  
16.8 2  
19.7 2  
Io12L  
Output current limit 1, 2  
Output noise incl. spikes  
Adjustment by R-input 4  
Vi nom, Io nom  
75  
75  
75  
75  
mVpp  
V
Vo  
BW = 20 MHz  
3
3
3
3
6.0  
17.25 1  
±150  
6.0  
17.25 1  
±150  
Vo adj  
Vo u  
Vi min V  
i max  
Static line/load regulation  
(total deviation of Vo)  
(0.1 1)Io nom  
mV  
Voltage  
deviation  
V
i nom, 0.5 Io2 nom  
Dynamic  
load  
±300  
1
±300  
±350  
1
±350  
Vo d  
to d  
5
Io1 nom 0.5 Io1 nom  
5
3
3
regulation Recovery time  
and after turn on  
ms  
Io nom,  
Temperature coefficient of  
output voltage  
±0.01 ±0.02  
-
±0.01 ±0.02  
-
%/K  
α v o  
TC min – TC max  
Table 5d: Output data of HR/ER2880 and HRP/ERP2880. General conditions as per table 5a  
Model  
HR2880 / ER2880  
2 × 48 V  
HRP2880 / ERP2880  
2 × 48 V  
Unit  
Nom. output voltage  
Output 1  
typ  
Output 2  
max min typ max min  
Output 1  
Output 2  
Characteristics  
Conditions  
min  
typ  
max  
min  
typ max  
47.7 48.0  
-
48.3  
48.0  
47.7  
48.0  
48.3  
48.0  
Vo  
Vo BR  
Io  
Output voltage  
Vi nom, 0.5 Io nom  
V
A
Output protection  
(suppressor diode)  
56.7  
62.7  
-
56.7  
62.7  
2.5  
Output 2  
2
2
2.5  
Output current nom.  
Vi min V  
i max  
Io1L, Io2L Output current limit 1  
2.1  
2.1  
-
2.625  
5.25 2  
2.625  
-
TC min – TC max  
4.2 2  
Io12L  
Output current limit 1, 2  
Output noise incl. spikes  
Adjustment by R-input 4  
Vi nom, Io nom  
240  
55.2 1  
±0.5  
240  
240  
55.2 1  
±0.5  
240 mVpp  
V
Vo  
BW = 20 MHz  
3
3
3
3
19.2  
19.2  
Vo adj  
Vo u  
Vi min V  
i max  
Static line/load regulation  
(total deviation of Vo)  
(0.1 1)Io nom  
mV  
Voltage  
deviation  
Vi nom, 0.5 Io2 nom  
Dynamic  
load  
±0.8  
1
±0.8  
±1.0  
1
±1.0  
Vo d  
to d  
5
Io1 nom 0.5 Io1 nom  
and after turn on  
5
3
3
regulation Recovery time  
ms  
Io nom,  
Temperature coefficient of  
output voltage  
±0.01 ±0.02  
-
±0.01 ±0.02  
-
%/K  
α v o  
TC min – TC max  
1
If the output voltages are increased above Vo nom through R-input control, remote sensing, or option T, the output currents should be  
reduced accordingly so that Po nom is not exceeded.  
Both outputs connected in parallel  
See Output voltage regulation  
For battery charger applications, a defined negative temperature coefficient can be provided by using a temperature sensor (see Accessories)  
See Dynamic load regulation  
Measured with a ceramic cap of 1 µF across each output.  
2
3
4
5
6
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 11 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
Thermal Considerations  
If a converter is located in free, quasi-stationary air (convection cooling) at the indicated maximum ambient temperature TA max  
(see table Temperature specifications) and is operated within the specified input voltage range and nominal load, the temperature  
measured at the Measuring point of case temperature TC (see Mechanical Data) will approach the indicated value TC max after the  
warm-up phase. However, the relationship between TA and TC depends heavily upon the conditions of operation and integration  
into a system. The thermal conditions are influenced by input voltage, output current, airflow, and temperature of surrounding  
components and surfaces. TA max is therefore, contrary to TC max, an indicative value only; see also fig. 9.  
Po ꢁWꢂ  
HRP2320  
HR2320  
300  
Convection  
cooling  
240  
180  
120  
60  
HRL2320  
TC max  
ꢃM23ꢀ  
0
TA ꢁ°Cꢂ  
50  
60  
70  
80  
ꢀ0  
100  
Fig. 9  
Power derating for HRP/HR/HRL2320  
Caution: The installer must ensure that under all operating conditions TC remains within the limits stated in the table Temperature specifications.  
Notes: Sufficient forced cooling or enhanced cooling with the help of cooling plates (options B, B1) allows for TA to be higher than 71 °C  
(e.g. 85 °C), as long as TC max is not exceeded.  
Thermal Protection  
Two temperature sensors generate an internal inhibit signal, which disables the converter in the case of overtemperature.  
The outputs automatically recover when the temperature drops below the limit.  
Interruption Time  
The integrated storage capacitor (Cb) is loaded to the boost voltage and ensures full output voltage with nominal load during an  
interruption time (or ride-through time) of at least 10 ms, provided that Vi was 20 V before the interruption. This complies with  
EN 50155:2017 class S2.  
Output Protection  
The 2nd output of double-output models is protected by a suppressor diode against overvoltage, which could occur due to a failure  
of the internal control circuit. This suppressor diode was not designed to withstand externally applied overvoltages. Overload at  
any of the outputs will cause both outputs to shut down.  
Note: Vo BR of the suppressor diode is specified in Electrical Output Data. If this voltage is exceeded, the suppressor diode generates losses  
and may become a short circuit.  
Note: The output voltage of the first output is monitored. If it exceeds typ. 140% of Vo nom for 10 ms, the converter is inhibited. To reactivate,  
Vi must be removed or an inhibit signal must be applied to PUL (pin 24).  
Each output has its own current limiting circuit, providing a rectangular output characteristic and protecting against short circuit.  
There is no limitation for the capacitive load, and battery charging is possible as well.  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 12 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
Series and Parallel Connection  
Both outputs of the same converter can be series-connected or parallel-connected in order to double the output current or the  
output voltage respectively.  
Outputs of different converters may be series-connected.  
In parallel connection of several converters, the T-pins should be interconnected so that all converters share the output current  
equally; see fig. 10. HRL and ERL models have no T-pins and should not be operated in parallel connection.  
If both outputs of each converter are connected in series, Vo1– of both converters should be connected together and the T-pins  
as well. See fig. 11.  
ꢀM088a  
ꢁM084a  
6 Vo2+  
Vo2+  
Vo2–  
6
10  
4
Vo1+  
1
2
4
12 S1+  
Vo1+  
S1+  
T
Converter  
1
18 T  
Converter  
ꢁ1  
12  
18  
14  
8
ꢀ1  
14 S1–  
S1–  
Vo1–  
Vo2–  
10  
Vo1–  
8
Load  
Load  
Vo2+  
6
Vo2+  
Vo2–  
2
4Vo1+  
12 S1+  
18 T  
6
10  
Vo1+  
S1+  
T
1
1
4
12  
18  
14  
8
Converter  
ꢁ2  
Converter  
ꢀ2  
S1–  
14  
Vo2–  
10  
S1–  
Vo1–  
8
Vo1–  
1
2
Lead lines with equal length  
and cross section  
Diodes for redundant operation only  
Max. 5 converters  
in parallel connection  
Max. 5 converters  
+
T
in parallel connection  
Power bus  
Fig. 10  
Fig. 11  
Parallel connection with OR-ing diodes and sense lines  
connected at the load  
Parallel connection of double-output models with the ouputs  
of each converter connected in series, using option T.  
The signal at the T pins are referenced to Vo1–.  
Notes:  
– Not more than 5 converters should be connected in parallel.  
– If several outputs are connected in series, the resulting voltage can exceed the SELV level.  
– The PUL-pins (pin 24) should exhibit an individual PUL resistor for each converter. If the shutdown function is used, each PUL-pin must be  
controlled individually.  
– The R-pins should be left open-circuit. If not, the output voltages must individually be adjusted prior to paralleling within 1 to 2% or the R-pins  
should be connected together.  
– Series connection of second outputs without involving their main outputs should be avoided, as regulation may be poor.  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 13 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
Output Voltage Regulation  
If both outputs are connected in parallel or in series, the converter exhibits a rectangular output characteristic; see fig. 12.  
The typ. dynamic load regulation illustrates fig. 13.  
Vo/Vo nom  
Vo  
Vod  
0.ꢀ8  
0.5  
Vo ±1ꢀ  
Vod  
Vo ±1ꢀ  
td  
td  
t
Io/Io nom  
Io1  
IoL  
1
0.5  
0
10 µs  
10 µs  
050ꢀ8a  
t
05102c  
0
Io/Io nom  
0.5  
1.0  
Fig. 12  
Fig. 13  
Output characteristic Vo versus Io  
(both outputs connected in parallel or in series)  
Typical dynamic load regulation of Vo.  
Output 1 is under normal conditions regulated to Vo nom, irrespective of the output currents.  
However, Vo2 depends upon the load distribution; see fig. 14 a and fig.14b. Converters with version V101 (or later) have incorporated  
switchable preloads and do not need a minimum load.  
Note: If output 2 is not used, connect it with output 1 ! This ensures good voltage regulation and efficiency.  
V
ꢁVꢂ  
V
ꢁVꢂ  
o2  
o2  
ꢃM168  
ꢃM08ꢀc  
50  
12.3  
12.2  
12.1  
12.0  
11.ꢀ  
11.8  
11.7  
11.6  
I
I
I
I
I
= 2 A  
= 1.5 A  
= 1 A  
= 0.5 A  
= 0.2 A  
I
I
I
I
I
I
= 10 A  
= 7.5 A  
= 5.0 A  
= 2.5 A  
= 1.0 A  
= 0.1 A  
o1  
o1  
o1  
o1  
o1  
o1  
o1  
o1  
o1  
o1  
o1  
4ꢀ.5  
4ꢀ  
48.5  
48  
47.5  
47  
46.5  
I
o2  
I
o2  
0
0.4  
0.8  
1.2  
1.6  
2
2.4  
A
0
2
4
6
8
10  
12  
A
Fig. 14a  
Models HR/ER2320:Vo2 versus Io2 with various Io1  
Fig. 14b  
Models HR/ER2880:Vo2 versus Io2 with various Io1  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 14 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
Auxiliary Functions  
Inhibit Function  
The PUL input (pin 24) can also be used as inhibit (for the PUL function see table 3 and 4). The response time ton and the rise time tr  
are specified in table 2.  
The current coming out from pin 24 (PUL) is typ. 1.5 mA (<2 mA). If pin 24 is left open-circuit, the voltage is typ. 5 V. The converter  
is disabled when VPUL is 500 mV.  
ꢀM127  
ꢀM13ꢁc  
28  
tr  
Vo/Vo nom  
thu  
Vi+  
tf  
1
IPUL  
td on  
ton  
24  
PUL  
0.1  
0
toff  
30  
32  
PUL  
1
Vi–  
PE  
t
0
22  
Fig. 15  
Fig. 16  
Circuit for the inhibit function  
Typical output response to the PUL-signal (inhibit)  
Current Share Function  
If the pins 18 (T) of parallel-connected converters are connected together, the converters share the output current evenly. Refer  
to section Parallel and Series Connection. Not for HRL and ERL models.  
Sense Lines  
This feature allows for compensation of voltage drops across the connector contacts and if necessary, across the load lines. We  
recommend connecting the sense lines directly at the female connector.  
To ensure correct operation, both sense lines (S1+, S1–) should be connected to their respective power outputs (Vo1+ and Vo1–),  
and the voltage difference between any sense line and its respective power output (as measured on the connector) should not  
exceed the values specified in table 6.  
Table 6: Maximum voltage compensation allowed using sense lines  
Output  
voltage  
Total voltage difference  
between sense lines and  
their respective outputs  
Voltage difference  
between Vo1– and S1–  
12 V  
15 V  
48 V  
< 1.00 V  
< 1.25 V  
< 2.00 V  
< 0.5 V  
< 0.6 V  
< 1.0 V  
Important: Sense lines should be connected ! Incorrectly connected sense lines may activate the overvoltage protection resulting in a  
permanent short-circuit of the output. Open sense lines are allowed, but result in inaccurate output voltages.  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 15 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
Output Voltage Adjust  
As a standard feature, the converters offer an adjustable output voltage. The control input R (pin 16) accepts either a control  
voltage Vext or a resistor Rext to adjust the output voltage. When input R is not connected, the output voltage is set to Vo nom  
.
a) Adjustment by means of an external control voltage Vext between pin 16 (R) and pin 14 (S1–):  
The control voltage range is 1.0 – 2.875 V and allows for an adjustment in the range of approx. 40 – 115% of Vo nom  
.
V • 2.5 V  
__o_______  
Vext  
Vo nom  
Caution: Applying an external control voltage >2.875V may damage the converter.  
b) Adjustment by means of an external resistor:  
Depending on the value of the required output voltage, the resistor shall be connected  
either: between pin 16 (R) and pin 14 (S1–) to adjust the output voltage in the range of approx. 40 100% of Vo nom  
.
Vo  
___________  
Rext1 4 k•  
Vo nom Vo  
or: between pin 16 (R) and pin 12 (S1+) to adjust the output voltage in the range of 100 – 115% of Vo nom  
(Vo – 2.5 V)  
.
___________________  
Rext2 4 k•  
2.5 V • (Vo/Vo nom – 1)  
Caution: To prevent the converter from damage, the value of Rext shall never be less than the value for increasing Vo1 to 115% !  
ꢀM0ꢁ1a  
Vi+  
S1+  
12  
16  
Rext2  
4 k  
V
ref = 2.5 V  
R
+
+
Control  
logic  
Vext  
Rext1  
S1–  
Vi–  
14  
Fig. 17  
Output voltage adjustment  
Notes:  
– If the output voltages are increased above Vo nom via R-input control, sense lines, or option T, the output currents should be reduced, so that  
Po nom is not exceeded.  
– The second output of double-output models follows the voltage of the controlled main output.  
Output Voltage Monitor  
The output voltage monitor generates a logic “low” signal (NPN open-collector output) at the D-output (pin 20), when Vo1 0.96 Vo nom  
.
For converters with version V101 (or later), the voltage at S1+ (corresponding to Vo1) must be 0.96 Vo nom and 1.04 Vo nom (typ.  
values). Then, a green LED (Out OK) at the frontplate is illuminated. If the output voltage is adjusted by the R-input, the trigger  
levels are corrected accordingly.  
At low D-output, the current is limited by a 10 protective resistor; for converters with Version V102 (or later) ID should be 100 mA.  
If the D-output is high (open collector), VD should be 75 V. For previous converters: 50 mA and 50 V.  
Note: Output overvoltage activates a latch;see Output Protection.  
ꢀM0ꢁ0  
S1+  
12  
R
p
I
D
NPN open  
collector  
D
20  
14  
10  
V
D
S1–  
Fig. 18  
Output voltage monitor  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 16 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
Indicators  
Two green LED indicators are visible at the front plate:  
- Out OK; see Output Voltage Monitor  
- In OK. This signal is activated when Vi is below 158 V and greater than Vi min, whereas Vi min is defined by the adjust resistor  
connected to the PUL input (pin 24).  
Battery Charging /Temperature Sensor  
All converters with an R-input are suitable for battery charger application. For optimal battery charging and life expectancy of the  
battery an external temperature sensor can be connected to the R-input. The sensor is mounted as close as possible to the battery  
and adjusts the output voltage according to the battery temperature.  
Depending upon cell voltage and the temperature coefficient of the battery, different sensor types are available; see Accessories.  
Cell voltage ꢀVꢁ  
0613ꢂb  
2.45  
030ꢀꢀd  
2.40  
Vo+  
Vo–  
Power  
supply  
Load  
Input  
2.35  
R
2.30  
2.25  
2.20  
2.15  
2.10  
+
+
Vo safe  
Battery  
Temperature sensor  
–20  
–10  
0
10  
20  
30  
40  
50 °C  
VC = 2.27 V, –3 mV/ꢃ  
VC = 2.23 V, –3 mV/ꢃ  
VC = 2.27 V, –3.5 mV/ꢃ  
VC = 2.23 V, –3.5 mV/ꢃ  
Fig. 19  
Fig. 20  
Connection of a temperature sensor  
Trickle charge voltage versus temperature for defined temp.  
coefficient. Vo nom is the output voltage with open R-input.  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 17 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
Electromagnetic Compatibility (EMC)  
A metal oxide VDR together and an efficient input filter form an effective protection against high input transient voltages, which  
typically occur in most installations. The converters have been successfully tested to the following specifications:  
Electromagnetic Immunity  
Table 7: Electromagnetic immunity (type tests)  
Phenomenon  
Standard Level Coupling mode 1 Value  
applied  
Waveform  
Source Test procedure  
imped.  
In  
Perf.  
oper. crit.2  
Electrostatic  
discharge (to case) 61000-4-2  
IEC/EN  
contact discharge 8000 Vp  
10 pos. & 10 neg.  
discharges  
330 Ω  
150 pF  
4 3  
x 4  
1/50 ns  
yes  
yes  
A
A
air discharge  
antenna  
15000 Vp  
20 V/m  
20 V/m  
10 V/m  
5 V/m  
Electromagnetic  
field  
IEC/EN  
61000-4-3  
AM 80% / 1 kHz  
N/A  
80 – 1000 MHz  
800 – 1000 MHz  
1400 – 2000 MHz  
2000 – 2500 MHz  
5100 – 6000 MHz  
5
antenna  
antenna  
AM 80% / 1 kHz  
N/A  
yes  
A
3 V/m  
10 V/m  
50% duty cycle,  
200 Hz rep. rate  
900 ±5 MHz  
pulse modul.  
3
N/A  
yes  
yes  
A
A
Electrical fast  
transients / burst  
IEC/EN  
61000-4-4  
3 6  
capacitive, o/c 1 ±2000 Vp  
60 s positive  
60 s negative  
transients per  
coupling mode  
burstsof 5/50ns;  
2.5 / 5 kHz over 15 ms;  
burst period: 300 ms  
i/c, +i/–i 1  
±4000 Vp  
direct  
50 Ω  
4
i/c 1  
±2000 Vp  
±1000 Vp  
42 Ω  
Surges  
IEC/EN  
61000-4-5  
5 pos. & 5 neg.  
surges per  
coupling mode  
3 7  
1.2 / 50 µs  
yes  
A
+i/i 1  
0.5 μF  
Conducted  
disturbances  
IEC/EN  
61000-4-6  
10 VAC  
(140 dBµV)  
3 8  
3 9  
-
i, o, signal wires  
AM 80% / 1 kHz  
150 0.15 – 80 MHz  
yes  
yes  
yes  
A
A
A
Power frequency  
magnetic field  
IEC/EN  
61000-4-8  
-
-
300 A/m  
60 s in all 3 axes  
Pulse magnetic  
field  
IEC/EN  
61000-4-9  
5 pulses per axis  
repetit. rate 10 s  
±300 A/m  
1
i = input, o = output, c = case  
2
3
4
5
6
7
8
9
A = normal operation, no deviation from specs.; B = normal operation, temporary loss of function or deviation from specs possible  
Exceeds EN 50121-3-2:2016 table 5.3 and EN 50121-4:2016 table 2.4.  
Corresponds to EN 50121-3-2:2016 table 5.1 and exceeds EN 50121-4:2016 table 2.1.  
Corresponds to EN 50121-3-2:2016 table 5.2 and EN 50121-4:2016 table 2.2 (compliance with digital communication devices).  
Corresponds/exceeds EN 50121-3-2:2016 table 3.2 and EN 50121-4:2016 table 4.2.  
Covers EN 50121-3-2:2016 table 5.3 and EN 50121-4:2016 table 4.3.  
Corresponds to EN 50121-3-2:2016 table 3.1 and EN 50121-4:2016 table 4.1 (radio frequency common mode).  
Corresponds to EN 50121-4:2016 table 2.3.  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 18 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
Electromagnetic Emissions  
All conducted emissions (fig. 21 and 22) have been tested according to EN 55011, group 1, class A. These limits are much  
stronger than requested in EN 50121-3-2:2016, table 2.1, and coincide with EN 50121-4:2016, table 1.1. The limits in fig. 21 and  
22 apply to quasipeak values, which are always lower then peak values.  
In addition, the values for average must hold a limit 10 dBµV below the limits in fig. 21 and 22 (not shown).  
Radiated emissions have been tested according to EN 55011, group 1, class A . These limits are similar to the requirements of  
EN 50121-3-2:2016 and EN 50121-4:2016, both calling up EN 61000-6-4+A1:2011, table 1. The tests were executed with hori-  
zontal and vertical polarization. The worse result is shown in fig. 22 and 23.  
VUS EMC Labatory, Vin = 110 VDC, Iout = 2x 10 A, C115.  
Testdistance 10 m, Class A, HR2320-9RG, B01932739, U00004, 26.07.2012  
dBµV  
VUS EMC Labatory, Vin  
Testdistance 10 m, Class A, HR2320-ꢁRꢂ, B01ꢁ3273ꢁ, U00004, 26.07.2012  
=
24 VDC, Iout  
=
2x 10 A, C115.  
dBµV  
80  
80  
60  
40  
EN 55011 A qp  
EN 55011 A av  
EN 55011 A qp  
EN 55011 A av  
60  
40  
20  
0
20  
0
0.2  
0.5  
1
2
5
10  
20 MHz  
0.2  
0.5  
1
2
5
10  
20 MHz  
Fig. 21  
Fig. 22  
Typ. conducted emissions (peak/quasipeak and average) at  
the input, measured at Vi = 24 V and Io nom (HR2320-9RG).  
Typ. conducted emissions (peak/quasipeak and average) at  
the input, measured at Vi = 110 V and Io nom (HR2320-9RG,  
ER2320-9RG).  
VUS EMC Labatory, Vin  
Testdistance 10 m, Class A, HR2320-ꢀRꢁ, B01ꢀ3273ꢀ, U00004, 26.07.2012  
= 110 VDC, Iout=2x10A, C115.  
VUS EMC Labatory, Vin  
Testdistance 10 m, Class A, HR2320-ꢀRꢁ, B01ꢀ3273ꢀ, U00004, 26.07.2012  
= 24 VDC, Iout=2x10A, C115.  
dBµV/m  
60  
dBµV/m  
60  
EN 5501A  
EN 55011 A  
EN 55011 A  
50  
40  
30  
20  
50  
40  
30  
20  
10  
10  
0
30  
0
30  
50  
100  
200  
500  
1000 MHz  
50  
100  
200  
500  
1000 MHz  
Fig. 23  
Fig. 24  
Typ.radiated emissions in 10 m distance, measured at Vi = 24 V  
Typ.radiated emissions in10m distance,measured at Vi = 110V  
and Io nom (HR2320-9RG).  
and Io nom (HR2320-9RG, ER2320-9RG).  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 19 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
Immunity to Environmental Conditions  
Table 8: Mechanical and climatic stress  
Test method  
Standard  
Test Conditions  
Temperature:  
Status  
Cab Damp heat  
steady state  
IEC/EN 60068-2-78  
MIL-STD-810D section 507.2  
40±2 °C  
Converter  
not operating  
Relative humidity:  
Duration:  
93+2/-3  
%
56 days  
55°C and 25°C  
2
Db 2 Cyclic damp heat  
test  
EN 50155:2017, clause 13.4.7  
IEC/EN 60068-2-30  
Temperature:  
Converter  
not operating  
Cycles (respiration effect)  
Duration:  
2x 24 h  
70°C  
Be  
Ad  
Ka  
Dry heat test  
steady state  
EN 50155:2017, clause 13.4.5  
IEC/EN 60068-2-2  
Temperature:  
Converter  
operating  
Duration:  
6 h  
Low temperature  
start-up test  
EN 50155:2017, clause 13.4.4  
IEC/EN 60068-2-1  
Temperature, duration:  
Performance test:  
-40 °C, 2 h  
+25 °C  
35 ±2 °C  
48 h  
Converter  
not operating  
Salt mist test  
EN 50155:2017, clause 13.4.10 Temperature:  
Duration:  
Converter  
not operating  
sodium chloride  
(NaCl) solution  
Fc  
Fh  
Vibration  
(sinusoidal)  
IEC/EN 60068-2-6  
MIL-STD-810D section 514.3  
Acceleration amplitude:  
0.35 mm (10 – 60 Hz)  
5 gn = 49 m/s2 (60 - 2000 Hz)  
10 – 2000 Hz  
Converter  
operating  
Frequency (1 Oct/min):  
Test duration:  
7.5 h (2.5 h in each axis)  
Random vibration  
broad band (digital  
control) & guidance  
IEC/EN 60068-2-64  
Acceleration spectral density: 0.05 gn2/Hz  
Frequency band:  
8 – 500 Hz  
Converter  
operating  
Acceleration magnitude:  
Test duration:  
4.9 gn  
rms  
1.5 h (0.5 h in each axis)  
50 gn = 490 m/s2  
11 ms  
Ea  
Shock  
(half-sinusoidal)  
IEC/EN 60068-2-27  
MIL-STD-810D section 516.3  
Acceleration amplitude:  
Bump duration:  
Converter  
operating  
Number of bumps:  
Acceleration amplitude:  
Bump duration:  
18 (3 in each direction)  
5.1 gn  
-
-
Shock  
EN 50155:2017 clause 13.4.11,  
EN 61373:2010 sect. 10,  
class B, body mounted 1  
Converter  
operating  
crit. A  
30 ms  
Number of bumps:  
18 (3 in each direction)  
2
Simulated long life  
testing at increased  
random vibration  
levels  
EN 50155:2017 clause 13.4.11.2, Acceleration spectral density: 0.02 gn /Hz  
EN 61373:2010 sect. 8 and 9,  
Converter  
operating  
crit. A  
Frequency band:  
Acceleration magnitude:  
Test duration:  
5 – 150 Hz  
class B, body mounted 1  
0.8 gn rms  
15 h (5 h in each axis)  
1
Body mounted = chassis of a railway coach  
Temperatures  
Table 9: Temperature specifications, valid for an air pressure of 800 – 1200 hPa (800 – 1200 mbar)  
Model  
-9  
Unit  
Characteristics  
Conditions  
min  
- 40  
- 40  
- 55  
typ  
max  
TA  
TC  
TS  
Ambient temperature  
Converter operating  
71 1  
2
Case temperature  
95 1  
° C  
Storage temperature  
Not operational  
85  
1
2
See Thermal Considerations.  
Overtemperature lockout at TC >95 °C (An NTC resistor on primary and secondary heatsink).  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 20 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
Reliability  
Table 10: MTBF and device hours  
Ratings at specified  
case temperature  
Bellcore SR332  
Model  
Ground benign  
40 °C  
Ground fixed  
Ground mobile Life test 1 Device hours 2  
Unit  
40 °C  
176 000  
70 °C  
50 °C  
25 °C  
HR2320  
352 000  
49 000  
38 000  
500 000  
h
1
Life test with 32 converters during 26 days, cycling at 60 °C; confidence level 60%.  
Statistical values, based on an average of 4300 working hours per year and in general field use over 5 years; upgrades and customer-  
2
induced errors are excluded.  
Mechanical Data  
Dimensions in mm. The converters are designed to be inserted into a 19” rack, 160 mm long, according to IEC 60297-3.  
7 TE  
30.3  
5 TE  
3.27  
(171.0 to 171.ꢁ)  
50  
M4  
ꢂM0ꢁ2  
Out Oꢀ  
In Oꢀ  
Measuring point of  
case temperature TC  
d
8
152  
8
27.38  
60  
Front plate  
Back plate  
Main face  
168.5  
Ø5 x ꢁ0°  
Ø2.8  
Screw holes of the  
frontplate  
European  
Projection  
Fig. 25  
Case S03 for HR / ER and HRL / ERL models with heat sink;  
Aluminum, black finish (EP powder coated);  
weight approx. 1.5 kg  
Notes:  
– d 15 mm, recommended minimum distance to next part in order to ensure proper air circulation at full output power.  
– free air location: the converter should be mounted with fins in a vertical position to achieve maximum airflow through the heat sink.  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 21 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
Dimensions in mm. The converters are designed to be inserted into a 19” rack, 160 mm long, according to IEC 60297-3.  
7 TE  
30.3  
ꢀ TE  
3.27  
15ꢀ  
4.5  
ꢁM0ꢀ3  
Out Oꢂ  
In Oꢂ  
d
Measuring point of  
case temperature TC  
50  
27.38  
(171.0 .... 171.ꢀ)  
80  
Front plate  
Back plate  
Main face  
168.5  
Ø5 x ꢀ0°  
Ø2.8  
Screw holes of the  
frontplate  
European  
Projection  
Mounting slots for chassis or wall mounting  
Fig. 26  
Case K03 for HRP and ERP models with heat sink;  
Aluminum, black finish (EP powder coated);  
weight approx. 1.8 kg  
Notes:  
– d 15 mm, recommended minimum distance to next part in order to ensure proper air circulation at full output power.  
– free air location: the converter should be mounted with fins in a vertical position to achieve maximum airflow through the heat sink.  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 22 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
5
47.2  
38.5  
6.5  
11027  
11.8  
±0.2  
17.3  
133.4  
168  
30  
Fig. 27  
Option B: Aluminum case S03 with large cooling plate; black finish (EP powder coated).  
Suitable for front mounting.  
Total weight approx. 1.5 kg  
Note: Long case with option B2, elongated by 60 mm for 220 mm rack depth, is available on request. (No LEDs)  
7 TE  
3.27  
4 TE  
50  
38.5  
5
158  
11.8  
ꢁM0ꢀ4  
M 4  
Out Oꢂ  
In Oꢂ  
Measuring point of  
case temperature TC  
5
47.2  
17.3  
133.4  
168  
(171.0 ... 171.ꢀ)  
Fig. 28  
Option B1: Aluminum case S03 with small cooling plate; black finish (EP powder coated).  
Suitable for mounting with access from the backside.  
Total weight approx. 1.4 kg.  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 23 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
Safety and Installation Instructions  
Connector Pin Allocation  
The connector pin allocation table defines the electrical potentials and the physical pin positions on the H15 connector. The  
protective earth is connected by a leading pin (no. 22), ensuring that it makes contact with the female connector first.  
S10002b  
30 26 22 18 14 10  
32 28 24 20 16 12  
6
8
4
Fixtures for retention clips  
Fig. 29  
View of module’s male connectors  
Table 11: Pin allocation  
Pin  
4
Name  
Vo1+  
Vo2+  
Vo1-  
Vo2-  
S1+  
S1-  
R
Function  
Output 1 positive  
Output 2 positive  
Output 1 negative  
Output 2 negative  
Sense line positive  
Sense line negative  
6
8
10  
12  
14  
16  
18 2  
20  
Output voltage adjust  
Current share  
Out OK  
T
D
22 1  
PE  
Protection earth  
24  
PUL  
Vi+  
Vi-  
Programmable undervoltage lockout  
Input positive  
26 + 28  
30 + 32  
Input negative  
1
2
Leading pin (pre-connecting)  
Not connected for HRL models  
Installation Instructions  
The converters are components, intended exclusively for inclusion within other equipment by an industrial assembly operation  
or by professional installers. Installation must strictly follow the national safety regulations in compliance with the enclosure,  
mounting, creepage, clearance, casualty, markings, and segregation requirements of the end-use application.  
Connection to the system shall be made via the female connector H15; see Accessories. Other installation methods may not meet  
the safety requirements.  
Pin no. 22 ( ) is connected with the case. For safety reasons it is essential to connect this pin reliably to protective earth.  
Notes:  
– The PUL function (pin 24) must be programmed to enable the outputs. PUL should be connected to Vi– (pins 30 + 32) by a resistor to adjust  
the start-up voltage; see table 3. Otherwise, the input current may become too high at low input voltage.  
– Do not open the converter, or warranty will be invalidated.  
– If the second output is not used, connect it in parallel with the main output.  
Make sure that there is sufficient airflow available for convection cooling and verify it by measuring the case temperature TC, when  
the converter is installed and operated in the end-use application; see Thermal Considerations.  
Ensure that a converter failure (e.g. an internal short-circuit) does not result in a hazardous condition.  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 24 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
Standards and Approvals  
The converters are safety-approved to UL/CSA 60950-1 2nd Ed. and IEC/EN 60950-1 2nd Ed.  
The converters correspond to Class I equipment (with case connected to ground). They have been evaluated for:  
• Building-in  
• Basic insulation between input and case based on 250 VA. Double or reinforced insulation between input and outputs  
• Functional insulation between outputs  
• Overvoltage category II  
• Pollution degree 2 environment  
• Max. altitude: 2000 m  
• The converters fulfill the requirements of a fire enclosure.  
The output voltage is considered as SELV, except HR/HRP/ER/ERP2880 with both outputs in series connection.  
The converters are subject to manufacturing surveillance in accordance with the above mentioned standards and ISO 9001:2015.  
CB-scheme is available on request.  
Protection Degree and Cleaning Liquids  
The protection degree is IP 40, provided that the female connector is fitted to the converter.  
In order to avoid possible damage, any penetration of cleaning fluids has to be prevented, since the power supplies are not  
hermetically sealed.  
Railway Application and Fire Protection  
The converters have been designed by observing the railway standards EN 50155, EN 50121-3-2, and EN 50121-4. All boards  
are coated with a protective lacquer.  
The converters comply with NF-F16 (I2/F1). They also comply with EN 45545-1, EN 45545-2, if installed in a technical compartment  
or cabinet.  
Isolation and Protective Earth  
The electric strength test is performed in the factory as routine test according to EN 50514 and IEC/EN 60950 and should not be  
repeated in the field. The Company will not honor warranty claims resulting from incorrectly executed electric strength tests. The  
resistance case to the earth pin (<0.1 ) is tested with 25 A for 1 s.  
Table 12: Isolation  
Characteristics  
Input to  
Case + Outputs  
Output(s)  
to Case  
Output 1 to  
Output 2  
Unit  
Electric strength test  
Factory test 10 s  
2.8 1  
1.4  
1.0  
0.3  
0.21  
>100 2  
-
kVDC  
kVAC  
MΩ  
AC test voltage equivalent to factory test  
2.0  
Insulation resistance  
>300  
≥ 3.5 3  
>300  
≥ 2.5  
Creepage distances  
mm  
1
According to EN 50514 and IEC/EN 60950, subassemblies connecting input to output are pre-tested with 5.6 kVDC or 4 kVAC.  
Tested at 150 VDC  
Input to outputs: 6.4 mm  
2
3
Description of Options  
B, B1 Cooling Plates  
Where a cooling surface is available, we recommend the use of a cooling plate instead of the standard heat sink. The mounting  
system should ensure that the maximum case temperature TC max is not exceeded. The cooling capacity is calculated by (η see  
Model Selection):  
(100% – η)  
PLoss  
=
–––––––––– • Vo Io  
η
For the dimensions of the cooling plates; see Mechanical Data.  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 25 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
Accessories  
A variety of electrical and mechanical accessories are available including:  
– Front panels for 19” DIN-rack: Schroff or Intermas, 12 or 16TE /3U; see fig. 30 and the data sheet BCD.00495.  
– Mating H15 connectors with screw, solder, faston, or press-fit terminals; see fig. 31  
– Coding clips for connector coding HZZ00202  
– Pair of connector retention clips HZZ01209-G; see fig. 32  
– Connector retention brackets HZZ01216-G; see fig. 33  
– Cage clamp adapter HZZ00144-G; see fig. 34  
– Cable hood for H15 connectors (fig 35):  
- HZZ00141-G, screw version  
- HZZ00142-G, use with retention brackets HZZ01218-G  
- HZZ00143-G, metallic version providing fire protection  
– Wall-mounting plate K02 (HZZ01213-G) for models with option B1; see fig. 36  
– DIN-rail mounting assembly HZZ0615-G (DMB-K/S); see fig. 37  
– Additional external input and output filters  
– Different battery sensors S-KSMH... for using the converter as a battery charger. Different cell characteristics can be selected;  
see fig. 38, table 13, and Battery Charging/Temperature Sensors.  
For additional accessory product information, see the accessory data sheets listed with each product series or individual  
model at our web site belfuse.com/power-solutions.  
Fig. 31  
Different mating connectors  
Fig. 30  
Fig.32  
Different front panels  
Connector retention clips to fasten the H15 connector to the  
rear plate; see fig.29. HZZ01209-G consists of 2 clips.  
20 to 30 Ncm  
Fig. 33  
Fig. 34  
Connector retention brackets HZZ01216-G  
Cage clamp adapter HZZ00144-G  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 26 of 27  
ER / HR Series  
144 / 288 W 10:1 DC-DC Converters  
Fig. 35  
Fig. 36  
Different cable hoods  
Chassis- or wall-mounting plate HZZ01213-G (Mounting  
plate K02)  
European  
Projection  
26 (1.02")  
09125a  
L
56 (2.2")  
adhesive tape  
L = 2 m (standard length)  
other cable lengths on request  
Fig. 37  
Fig. 38  
Battery temperature sensor  
DIN-rail mounting assembly HZZ00615-G (DMB-K/S)  
Table 13: Battery temperature sensors  
Battery  
voltage nom.  
[V]  
Sensor type  
Cell  
Cell temp. Cable  
voltage coefficient length  
[V]  
[mV/K]  
–3.0  
–3.5  
–3.0  
–3.5  
–3.5  
–3.5  
–3.5  
–3.0  
–3.5  
[m]  
2
12  
12  
24  
24  
24  
24  
24  
48  
48  
S-KSMH12-2.27-30-2  
S-KSMH12-2.27-35-2  
S-KSMH24-2.27-30-2  
S-KSMH24-2.27-35-2  
S-KSMH24-2.31-35-0  
S-KSMH24-2.31-35-2  
S-KSMH24-2.35-35-2  
S-KSMH48-2.27-30-2  
S-KSMH48-2-27-35-2  
2.27  
2.27  
2.27  
2.27  
2.31  
2.31  
2.35  
2.27  
2.27  
2
2
2
4.5  
2
2
2
2
NUCLEAR AND MEDICAL APPLICATIONS - These products are not designed or intended for use as critical components in life support systems,  
equipment used in hazardous environments, or nuclear control systems.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the  
date manufactured. Specifications are subject to change without notice.  
tech.support@psbel.com  
belfuse.com/power-solutions  
BCD.00185 Rev AH, 07-Jun-2018  
© 2018 Bel Power Solutions & Protection  
Page 27 of 27  

相关型号:

HR2340

Loadable PLD, CMOS
HONEYWELL

HR24-8AJ4P2200A

Circular Connector, 4 Contact(s), Brass, Male, Jack
HRS

HR24-8AJ4P3050A

Circular Connector, 4 Contact(s), Brass, Male, Jack
HRS

HR24-8AJ4P5050A(01)

Circular Connector, 4 Contact(s), Brass, Male, Jack
HRS

HR24-8AJ4P550A

Circular Connector, 4 Contact(s), Brass, Male, Jack
HRS

HR24-8ALJ4P1050A(01)

Circular Connector, 4 Contact(s), Brass, Male, Jack
HRS

HR24-8ALJ4P2200A(01)

Circular Connector, 4 Contact(s), Brass, Male, Jack
HRS

HR24-8ALJ4P3050A

Circular Connector, 4 Contact(s), Brass, Male, Jack
HRS

HR24-8ALJ4P5050A(01)

Circular Connector, 4 Contact(s), Brass, Male, Jack
HRS

HR24-8ALJ4P550A(01)

Circular Connector, 4 Contact(s), Brass, Male, Jack
HRS

HR24-8ALP4S1050A

Circular Connector, 4 Contact(s), Brass, Female, Plug
HRS