LDB120 [BEL]
Output: 12 or 24 VDC model dependent;型号: | LDB120 |
厂家: | BEL FUSE INC. |
描述: | Output: 12 or 24 VDC model dependent |
文件: | 总4页 (文件大小:409K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
LDB120 Series is a single phase 120 W integrated DIN Rail Battery
Charger / DC UPS Power Supplies, suitable for wide variety of
industrial applications.
In case of mains or unit failure the DC UPS function enables the power
supply to feed the load from the battery without any interruption, until
the mains is recovered or the battery reaches the “Deep Discharge
Voltage” threshold.
These units have received excellent market approval for their high
efficiency, excellent reliability and compactness. Simple but elegant
look and easy installation make them market leaders for various
industrial applications.
LDB120 Series are isolation devices suitable for SELV and PELV
circuitry and are designed to be mounted on DIN rail and installed
inside a protective enclosure.
Input: 120 - 240 VAC
•
•
•
Output: 12 or 24 VDC model dependent
To be used with Lead Acid batteries or lithium batteries
(compatible with Lead Acid batteries)
Efficiency up to 86%
•
•
•
Economic solution for general purpose applications
Instantaneous LOAD switch BACKUP mode
2
LDB120 Series
LDB120-12
LDB120-24
120 - 240 VAC (140 - 345 VDC)
120 - 240 VAC (140 - 345 VDC)
1
1
12 VDC
24 VDC
7 A
5 A
Technical parameters are typical, measured in laboratory environment at 25°C and 240 VAC / 50 Hz, at nominal values, after
minimum 5 minutes of operation.
Nominal
Range
120 - 240 VAC
100 - 264 VAC
Input AC Voltage Range
Input DC Voltage Range
Input Frequency
Rated
110 - 345 VDC
47 - 63 Hz
Vin = 120 VAC
Vin = 240 VAC
2.0 A
1.1 A
Input AC Current
Input DC Current
Vin = 140 VDC
Vin = 345 VDC
1.4 A
0.5 A
Inrush peak current ² / I²t
Touch (Leakage) Current
Internal Protection Fuse
≤ 24 A / 0.50 A²s
≤ 0.6 mA
Not user replaceable
Fuse 3.15 AT
Fuse 4 AT or MCB 4 A C curve /
Cartridge fuse Class CC 4AT 250 VAC
It is strongly recommended to provide external surge
arresters (SPD) according to local regulations
Recommended External Protection 1
1 In order to be UL compliant use Listed Cartridge nonrenewable (JDDZ) fuse Class CC 4AT 250 VAC.
2 Peak current measured after 0.2 ms from main connection; 240 VAC/ 50 Hz; Ambient temperature at 25°C; Cold Start.
Output Power
120 W
LDB120-12 (to be set at 14 VDC for battery charging) 12 VDC (12 – 15 VDC)
LDB120-24 (to be set at 27 VDC for battery charging) 24 VDC (23 – 28 VDC)
Rated Voltage (Adjustable Voltage Range)
Continuous Current
LDB120-12
LDB120-24
LDB120-12
LDB120-24
LDB120-12
LDB120-24
7 A
5 A
11.5 A
6.5 A
> 20 A / 40 ms
> 16 A / 80 ms
Overload Limit
Short Circuit Peak Current
Load Regulation
Ripple & Noise 3
≤ 1%
≤ 100 mVpp
Vin = 120 VAC
Vin = 240 VAC
Vin = 120 VAC
Vin = 240 VAC
≥ 10 ms
≥ 80 ms
≥ 10 ms
≥ 55 ms
LDB120-12
LDB120-24
Hold up Time
Overload/short circuit: Hiccup mode
Thermal protection
Output overvoltage
LDB120-12
Protections
≥ 18 VDC
≥ 33 VDC
Output Overvoltage Protection (Active)
Battery Protections
LDB120-24
Against short-circuit with resettable fuse (9 A)
Against reverse polarity connection
Against deep discharge
tech.support@psbel.com
3
LDB120 Series
LDB120-12
LDB120-24
10.5 VDC ± 0.5 V
20.5 VDC ± 0.5 V
Deep Discharge Cut-Off Voltage
LOAD ON PSU - green LED
Status Signals
LOAD ON BATTERY - amber LED
Dry contact (SPDT, 24 VDC / 1 A)
Not Recommended
Parallel Connection
Efficiency
LDB120-12
LDB120-24
LDB120-12
LDB120-24
> 83.5%
> 86%
< 21 W
< 20 W
Dissipated Power
Battery Information
Rated Voltage
LDB120-12
LDB120-24
12 - 14.4 VDC
24 - 28.8 VDC
Max Charging Current
0.8 A
3 Ripple and Noise are measured with 20MHz bandwidth, probe terminated with a 0.1μF MKP parallel capacitor.
NOTE: Power rating, losses, efficiency, ripple, thermal behaviour and start-up may change outside of the nominal rated input range.
Contact factory for details.
Operating Temperature 4
Storage Temperature
UL certified up to 50°C
- 40 to + 70°C
- 40 to + 80°C
LDB120-12
LDB120-24
- 0.75 W/°C over 50°C
- 1.2 W/°C over 50°C
Derating
Humidity
Non-condensing
5 - 95% RH
Lifetime Expectancy
at 25°C ambient full load
167’953 h (19.1 years)
MTBF
at 25°C ambient full load, according to MIL-HDBK-217F > 600 000 h
Overvoltage Category
Pollution Degree
EN 50178
IEC 60664-1
III
2
Protection Class
Class I
Input to Output
Input to Ground
Output to Ground
UL508 (certified)
EN 60950 (reference)
EN 50178 (reference)
EN 55022 (CISPR22)
EN 55011 (CISPR11)
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-11
4.2 kVDC
2.2 kVDC
0.75 kVDC
Isolation Voltage
Safety Standards & Approvals
EMC Standards
Emission
Immunity
Class A
Class A
Level 3
Level 2
Level 2
Level 3
Level 2
Protection Degree
Vibration Sinusoidal
EN 60529
IP20
5-17.8 Hz: ±1.6 mm; 17.8-500 Hz: 2 g
2 hours / axis (X, Y, Z)
IEC 60068-2-6
30 g 6 ms, 20 g 11 ms;
3 bumps / direction, 18 bumps total
Shock
IEC 60068-2-27
4 Start-up type tested: - 40°C, possible at nominal voltage with load deration.
North America
+1 408 785 5200
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
© 2021 Bel Power Solutions & Protection
BCD.00856_AC
4
LDB120 Series
Weight
500 g
Dimensions
54 x 115 x 110 mm
IEC 60715/H15/TH35-7.5(-15)
2.5 mm²
Mounting Rail
Connection Terminals
Case Material
Screw type pluggable (24 - 12 AWG)
Aluminum
Figure 1. Mechanical Drawing
INPUT CONNECTION
OUTPUT CONNECTION
▪
▪
▪
▪
LOAD + = Positive DC
LOAD - = Negative DC
BATTERY + = Positive DC Battery
BATTERY - = Negative DC Battery
Single phase:
L = Line
N = Neutral
= Earth ground
Signaling:
SPDT dry contact
DC:
L = + Positive DC
N = - Negative DC
▪
▪
▪
NO
NC
COM
= Earth ground
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.