LES015YH-83H [BEL]
DC-DC Regulated Power Supply Module, 1 Output, 15W, Hybrid;型号: | LES015YH-83H |
厂家: | BEL FUSE INC. |
描述: | DC-DC Regulated Power Supply Module, 1 Output, 15W, Hybrid |
文件: | 总3页 (文件大小:83K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
LES DC/DC Series Data Sheet
Features
Description
•
Industry Standard
Package
Industry Standard Pinout
100°C Case Operation
Short Circuit Protection
LES DC/DC converters provide up to 15 watts of output
power in an industry-standard package and footprint. With
a maximum case temperature of 100°C, the LES is well
suited for the most demanding telecom, networking, and
industrial applications. The LES features 1500VDC
isolation, short circuit protection, and six-sided shielding.
The LES is available with optional enable and voltage trim
pins. Please see the IAD Series for dual output
applications.
•
•
24V and 48V Inputs
Input Pi Filter and
6-Sided Shielding
Regulated Outputs
1500V Isolation
•
•
•
•
•
Efficiency vs. Load (24V Input)
85
80
75
70
65
60
55
50
45
LES010YE-A
EFF. (18v)
EFF. (24v)
EFF. (36v)
Technical Specifications
Input
Voltage Range
24 VDC Nominal
48 VDC Nominal
Reflected Ripple
±8 - 36 VDC
36 - 75 VDC
50 mA
10
20
30
40
50
60
70
80
90
100
LOAD %
Efficiency vs. Load (48V Input)
Output
85
80
75
70
65
60
55
50
Setpoint Accuracy
Line Regulation Vin Min. - Vin Max., Iout Rated
±±1
0.21
Vout
Load Regulation Iout Min. - Iout Max., Vin Nom.
Minimum Output Current
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
Voltage Trim Range
0.51 Vout
±01 Iout Rated
251 Iout
21 Vout
500 ms
±±01
LES010ZE
LES015ZG
Short Circuit / Overcurrent Protection
Current Limit Threshold Range, 1 of Iout Rated
Short Circuit Current Max.
Shutdown / Hiccup
±±0 - ±501
2001 Iout
(±2Vout & ±5Vout : 4.0A when Vout= 0.25V)
10
20
30
40
50
LOAD %
60
70
80
90
100
Ovp Trip Range
Ovp Type
±±5 -±401 Vout Nom.
Second Control Loop
General
Notes
Turn-On Time
10 ms
Positive/Negative Logic
400 kHz
† MTBF predictions may vary slightly from model to model.
Remote Shutdown
Switching Frequency
Isolation
Input - Output
Output - Case
Temperature Coefficient
Case Temperature
Operating Range
Storage Range
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
Specifications typically at 25°C, normal line, and full load,
unless otherwise stated.
1500 VDC
500 VDC
0.02 ppm/°C
Soldering Conditions: I/O pins, 260°C, ten seconds; fully
compatible with commercial wave-soldering equipment.
-40 To +100°C
-40 To +100°C
95%
Safety: Agency approvals may vary from model to model.
Please consult factory for specific model information.
5 g, 10 - 55 Hz
Units are water-washable and fully compatible with commercial
spray or immersion post wave-solder washing equipment.
6
MTBF† (Bellcore TR-NWT-000332)
Safety
2.5 X 10 hrs
UL, cUL, TUV
REV. JUL 11, 2003
Page 1 of 3
LES DC/DC Series Data Sheet
Model Selection
INPUT VOLTAGE
INPUT VOLTAGE
RANGE (VOLTS)
MAXIMUM INPUT
CURRENT (AMPS)*
OUTPUT
VOLTAGE (VOLTS)
RATED OUTPUT
CURRENT (AMPS)
RIPPLE & NOISE
pk-pk (mV)
TYPICAL
EFFICIENCY**
MODEL
(VOLTS)
LES008YD
LES010YE
LES015YG
24
24
24
±8-36
±8-36
±8-36
0.6
0.8
±.±
2.5
3.3
5
3.00
3.00
3.00
75
±00
±00
771
8±1
841
LES015YH
LES015YJ
LES008ZD
LES010ZE
LES015ZG
LES020ZG-3N
LES015ZH
LES015ZJ
24
24
48
48
48
48
48
48
±8-36
±8-36
36-75
36-75
36-75
40-60
36-75
36-75
±.3
±.3
±2
±5
2.5
3.3
5
±.25
±.00
3.00
3.00
3.00
4.00
±.25
±.00
±20
±50
75
851
861
771
8±1
831
841
861
861
0.35
0.4
±00
±00
±00
±20
±50
0.6
0.63
0.65
0.65
5
±2
±5
NOTES: * Maximum input current at minimum input voltage, maximum rated output power.
** At nominal V , rated output.
in
Mechanical Drawing
Thermal Impedance
Tolerances
Pin
Function
Inches:
.XX 0.020
.XXX 0.010
(Millimeters)
.X 0.5
.XX 0.25
Natural Convection
±00 LFM
200 LFM
300 LFM
400 LFM
±5.4 °C/W
±2.2 °C/W
9.3 °C/W
7.4 °C/W
6.4 °C/W
±
2
3
+Vin
-Vin
no pin
(Optional shutdown
Pin:
0.002
Pin)
0.05
4
5
+Vout
Case:
+ 0.04, - 0.00
no pin
Note:
+ 1.0, - 0.00
(Optional Trim Pin)
Thermal impedance data is
dependent on many environmen-
tal factors. The exact thermal
performance should be validated
for specific application.
6
-Vout
(Dimensions as listed unless otherwise
specified.)
REV. JUL 11, 2003
Page 2 of 3
OPTIONS
This page is offered as a reference. Consult factory for actual availability of options. When ordering
equipment options, use the following suffix information. Select preferred option(s) and add the suffix to the
model number. Ordering option examples are located below the options table.
OPTION
Negative Logic
SUFFIX
APPLICABLE SERIES
REMARKS
N
HAS, HBD, HBS, HES, HLS, HLD, LES,
QBS, QES, QLS, TES, TQD
TTL "Low" Turns Module ON
TTL "High" Turns Module OFF
Lucent-Compatible Trim
T
HAS, HBD, HBS, HES, HLS, QBS, QES,
QLS
Trim
±
2
3
IAS, LES
Enable
IAD, IAS, LES, SMS
IAS, LES
Trim and Enable
Pin Length and Heatsink Options
0.±±0" (2.8mm) Pin Length
Standard Pin Length is 0.±80" (4.6mm)
8
9
All Leaded Models
All Leaded Models
0.±50" (3.8mm) Pin Length
0.24" (6.±mm) Horizontal Heatsink
±H
All ±/4-Bricks, ±/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
0.24" (6.±mm) Vertical Heatsink
0.45" (±±.4mm) Horizontal Heatsink
0.45" (±±.4mm) Vertical Heatsink
0.95" (24.±mm) Horizontal Heatsink
0.95" (24.±mm) Vertical Heatsink
±V
2H
2V
3H
3V
All ±/4-Bricks, ±/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All ±/4-Bricks, ±/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All ±/4-Bricks, ±/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All ±/4-Bricks, ±/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All ±/4-Bricks, ±/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
Example Options:
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president
of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
REV. JUL 11, 2003
Page 3 of 3
相关型号: