LH2540-2D5 [BEL]

AC-DC Regulated Power Supply Module, 2 Output, 51W, Hybrid,;
LH2540-2D5
型号: LH2540-2D5
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

AC-DC Regulated Power Supply Module, 2 Output, 51W, Hybrid,

文件: 总6页 (文件大小:240K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
H SERIES AC/DC  
Power-Ones H Series of AC/DC power supplies provides a full  
Rated for use in convection applications, the H Series delivers  
high reliability power with a Mean Time Between Failure (MTBF)  
in excess of 300,000 hours. In addition to UL, CUL, and LGA  
regulatory compliance to IEC950/EN60950, the H series displays  
the CE Mark.  
range of features and options for chassis mount applications or 19”  
rack systems. With a universal input from 85 to 255 VAC, the H  
series meets the most rigorous requirements of commercial,  
industrial, and datacom systems. LED indicators display the status  
of the converter and allow visual monitoring of the system.  
FEATURES  
Universal Input, 85-255VAC  
4.2kV Isolation  
Individually Isolated Outputs  
Overtemperature, Overvoltage, and Overcurrent Protected  
CE marked to Low Voltage Directive  
Input Transient & ESD Compliance to EN61000-4-2/-3/-4/-5  
Greater than 300,000 Hours MTBF  
Optional ACFAIL and Undervoltage Detection  
Optional DIN Rail Mounting  
SINGLE OUTPUT MODEL SELECTION CHART  
OUTPUT  
VOLTAGE  
ADJUSTMENT  
RANGE  
MAXIMUM OUTPUT  
CURRENT  
LINE  
REGULATION  
LOAD  
REGULATION  
RIPPLE & NOISE  
mV (NOTE 1)  
INITIAL SETTING  
ACCURACY  
MODEL  
LH 1001-2R  
LH 1301-2R  
LH 1501-2R  
LH 1601-2R  
LH 1901-2R  
5.1V  
12.0V  
15.0V  
2ꢀ.0V  
ꢀ8.0V  
0.0V to 5.5V  
0.0V to 13.2V  
0.0V to 16.5V  
0.0V to 26.ꢀV  
0. 0V to 52.8V  
11.0A  
6.0A  
ꢀ.5A  
3.0A  
1.5A  
1.04  
0.ꢁ4  
0.74  
0.74  
0.ꢀ4  
1.04  
1.254  
1.04  
0.74  
0.ꢀ4  
200  
200  
200  
200  
150  
5.00V to 5.20V  
11.76V to 12.2ꢀV  
1ꢀ.70V to 15.30V  
23.52V to 2ꢀ.ꢀ8V  
ꢀ7.0ꢀ V to ꢀ8.ꢁ6V  
MULTIPLE OUTPUT MODEL SELECTION CHART  
OUTPUT  
ADJUSTMENT  
OUTPUT  
LINE  
LOAD  
RIPPLE & NOISE  
%p-p (NOTE 1)  
INITIAL SETTING  
ACCURACY  
MODEL  
VOLTAGE  
RANGE  
CURRENT  
2.0A  
2.0A  
1.7A  
1.7A  
5.0A  
0.7A  
0.7A  
5.0A  
0.6A  
0.6A  
REGULATION  
REGULATION  
12V  
12V  
15V  
15V  
5.1V  
12V  
12V  
5V  
Fixed  
Fixed  
Fixed  
Fixed  
Fixed  
Fixed  
Fixed  
Fixed  
Fixed  
Fixed  
0.ꢀ4  
0.74  
1.04  
1.04  
0.ꢀ4  
See Graph 1  
0.ꢀ4  
See Graph 2  
0.54  
See Graph 3  
See Graph 3  
0.54  
1.254  
1.254  
1.04  
1.04  
3.04  
1.254  
1.254  
3.04  
1.04  
1.04  
11.76V to 12.2ꢀV  
11.ꢀ0V to 12.60V  
1ꢀ.70V to 15.30V  
1ꢀ.25V to 15.75V  
5.00V to 5.20V  
11.ꢀ0V to 12.60V  
11.ꢀ0V to 12.60V  
5.00V to 5.20V  
LH 2320-2  
ꢀ8 Watts  
LH 2540-2  
51 Watts  
0.64  
LH 3020-2  
1.254  
1.254  
0.64  
1.04  
1.04  
ꢀ2 Watts  
LH 3040-2  
15V  
15V  
See Graph ꢀ  
See Graph ꢀ  
1ꢀ.25V to 15.75V  
1ꢀ.25V to 15.75V  
ꢀꢀ Watts  
NOTE: 1) Maximum peak-to-peak noise, 20 MHz bandwidth.  
Rev. 10/2000  
1
H SERIES AC/DC  
INPUT SPECIFICATIONS (NOTE 1)  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
85  
ꢀ7  
5.0  
10.7  
NOM  
MAX  
255  
63  
UNITS  
VAC  
Hz  
Input Voltage - AC  
Input Frequency  
Hold-up Time  
Continuous input range.  
AC Input.  
At 85VAC.  
mS  
W
At 110VAC.  
No Load Input Power  
Single output models, nominal input.  
Dual output models, nominal input.  
Triple output models, nominal input  
2.5  
ꢁ.0  
ꢁ.0  
Input Current  
Input Protection  
230 VAC at full rated load.  
Non-user serviceable internal AC input line fuse, 250V, slow blow.  
0.ꢀꢀ  
2.5  
ARMS  
A
Inrush Surge Current  
Internally limited by thermistor, one cycle, 25°C, 255VAC.  
ꢀ2  
APK  
NOTE: 1) All parameters measured at Tc=25°C, pins 2 and 23 connected, nominal input voltage and full rated load unless otherwise noted.  
OUTPUT SPECIFICATIONS (NOTE 1)  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
7ꢀ  
0
NOM  
MAX  
UNITS  
4
Amps  
Efficiency  
Full rated load, 230VAC. Varies with distribution of loads among outputs.  
Minimum load required for regulation.  
Full load, 20 MHz bandwidth.  
83  
Minimum loads  
Ripple and Noise  
Output Power  
See Model Selection Charts  
5V single output model  
56.1  
12V single output model  
15V single output model  
2ꢀV single output model  
ꢀ8V single output model  
Dual and triple output models  
72.0  
67.5  
72.0  
72.0  
Watts  
See Model Selection Chart  
Overshoot / Undershoot  
Transient Response  
Output voltage overshoot/undershoot at turn-on.  
Recovery time, to within 14 of initial set point due to a 50-1004 load change,  
ꢀ4 max. deviation. (Main output only on multi-output units).  
0
120  
V
µS  
Turn-on Rise Time  
Time required for output voltage to  
rise from 104 to ꢁ04, 1004 load.  
5V single output model  
12V single output model  
15V single output model  
2ꢀV single output model  
ꢀ8V single output model  
Dual output models  
5
25  
ꢀ0  
50  
70  
230  
80  
10  
15  
20  
85  
25  
75  
mS  
Triple output models  
210  
NOTE: 1) All parameters measured at Tc=25°C, pins 2 and 23 connected, nominal input voltage and full rated load unless otherwise noted.  
Graph 1  
Graph 3  
LH2320-2 Cross-Regulation  
LH3020-2 Cross-Regulation  
Graph 2  
Graph 4  
LH2540-2 Cross-Regulation  
LH3040-2 Cross-Regulation  
2
H SERIES AC/DC  
INTERFACE SIGNALS AND INTERNAL PROTECTION  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Overvoltage Protection  
5V single output model  
7.5  
21  
2ꢀ  
25  
31  
ꢀ1  
85  
V1, 12V single and dual output models  
V2, V3, 12V dual and triple output models  
V1, 15V single and dual output models  
V2, V3, 15V dual and triple output models  
2ꢀV single output model  
V
ꢀ8V single output model  
Overload Protection  
5V single output model  
12V single output model  
V1, V2, 12V dual output model  
V2, V3, 12V triple output model  
15V single output model  
11.ꢀꢀ  
6.2ꢀ  
2.08  
0.73  
ꢀ.68  
1.77  
0.62  
3.12  
1.56  
Amps  
°C  
V1, V2, 12V dual output model  
V2, V3, 15V dual and triple output models  
2ꢀV single output model  
ꢀ8V single output model  
Overtemperature Protection  
Inhibit Control Voltage  
Case temperature which activates protective shutdown and Inhibit LED.  
Automatic restart below this temperature.  
ꢁ5  
105  
Voltage to enable outputs (or connect pins 2 and 23 together)  
Voltage to disable outputs (or leave open)  
-50  
2.ꢀ  
0.8  
50.0  
V
Inhibit Control Current  
Inhibit LED  
Power OK LED  
Output Adjust Range  
Output Adjust Limits  
Outputs enabled.  
-60  
-100  
-220  
µA  
Red LED illuminated when output is inhibited.  
Green LED illuminated when output is within regulation limits.  
Percentage of output, single output models only.  
Voltage limits of +Voltage Adjust input.  
0
0
110  
8
4
V
SAFETY, REGULATORY, AND EMI SPECIFICATIONS  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Agency Approvals  
UL1ꢁ50.  
CSA 22.2 NO. 23ꢀ/ꢁ50.  
EN60ꢁ50 (LGA).  
Approved  
Dielectric Withstand Voltage  
Electromagnetic Interference  
Input to output.  
Output to output.  
EN55011 / CISPR 11 and EN55022 / CISPR 22 Conducted.  
EN55011 / CISPR 11 and EN55022 / CISPR 22 Radiated.  
ꢀ200  
300  
A
B
VDC  
Class  
ESD Susceptibility  
Per EN61000-ꢀ-2, level 2.  
kV  
Radiated Susceptibility  
Per EN61000-ꢀ-3, level 3.  
Per EN61000-ꢀ-3, level X  
10  
20  
V/M  
EFT/Burst  
Input Transient Protection  
Per EN61000-ꢀ-ꢀ, level 1.  
Per EN61000-ꢀ-5 class 1.  
0.5  
0.5  
0.5  
kV  
kV  
Line to Ground  
Line to Line  
Insulation Resistance  
Leakage Current  
Input to output.  
Per EN60ꢁ50, 26ꢀVAC.  
300  
M
mA  
1.ꢀ  
Output current derating versus temperature  
3
H SERIES AC/DC  
ENVIRONMENTAL SPECIFICATIONS  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Altitude  
Operating.  
Non-Operating.  
10k  
ꢀ0k  
ASL Ft.  
ASL Ft.  
Temperature- Operating  
Operating ambient temperature.  
Operating case temperature.  
-10  
-10  
-25  
50  
80  
100  
°C  
°C  
Temperature- Storage  
Temperature Coefficient  
0°C to 70°C (after 15 minute warm-up).  
5V single and triple output model  
12V single and dual output models  
15V single and dual output models  
2ꢀV single output model  
1.0  
2.ꢀ  
3.0  
ꢀ.8  
ꢁ.6  
mV/°C  
ꢀ8V single output model  
Relative Humidity  
Shock  
Vibration  
MTBF  
Non-Condensing.  
Per EN60068-2-27, MIL-STD-810D section 516.3.  
Per EN60068-2-6, MIL-STD-810D section 51ꢀ.3.  
Calculated, MIL-HDBK-217F, 0°C, ground benign, single output models.  
Calculated, MIL-HDBK-217F, 0°C, ground benign, dual output models.  
Calculated, MIL-HDBK-217F, 0°C, ground benign, triple output models  
5
ꢁ3  
15  
2
4RH  
G
GRMS  
38ꢀ,000  
306,000  
270,000  
Hours  
oz/gm  
Unit Weight  
27.1/770  
OPTIONS  
DESCRIPTION  
OPTION  
NOTES  
Undervoltage Monitor  
-D1 thru -D8  
Input and/or V1 output monitoring circuitry. The input and/or output undervoltage monitoring circuit operates  
independently of the built-in input undervoltage lock-out circuit. A logic "low" (JFET output) or "high" signal  
(NPN output) is generated at pin 5 as soon as one of the monitored voltages drops below the preselected  
threshold level. Consult factory for specific types. Not compatible with -V options.  
ACFAIL Signal (VME)  
-V2  
-V3  
This option defines an undervoltage monitoring circuit for the input voltage. Equivalent to -D option and  
generates an ACFAIL signal (V signal) which conforms to the VME standard. Not compatible with -D option.  
This option defines an undervoltage monitoring circuit for the input and main output voltage. Equivalent to  
–D option and generates an ACFAIL signal (V signal) which conforms to the VME standard.  
Not compatible with -D option.  
Front Panel for 1ꢁ” Rack  
Chassis Mounting Plate  
Order HZZ00802 front panel for 1ꢁ" rack mounting on Schroff systems.  
Order HZZ01215 for chassis mounting plates. Designed for mounting the 1ꢁ" cassette to a chassis/wall where  
only frontal access is given.  
DIN Rail Bracket  
Order HZZ01210 universal mounting bracket for DIN-rail or chassis mounting.  
Mating Connectors  
Order as follows for mating H11 connectors:  
HZZ00101: Faston, straight, 0.250” x 0.030” (6.3 x 0.8 mm)  
HZZ00102: Screw terminals, ꢁ0°, #13 AWG (2.5 mm2) max  
HZZ00103 Solder pin 0.200” (5.2 mm), Ø 0.063” (1.6 mm)  
PglienSin  
Output  
Dual  
Output  
Triple  
Output  
2
5
8
Inhibit Control  
-D or -V Option  
+V1  
Inhibit Control  
-D or -V Option  
Inhibit Control  
-D or -V Option  
+V3  
-V3  
+V2  
-V2  
+V1  
11  
1ꢀ  
17  
20  
23  
26  
2ꢁ  
32  
-V1  
+Voltage Adjust  
-Voltage Adjust  
+V1  
-V1  
GND (note1)  
Neutral  
+V2  
-V2  
+V1  
-V1  
-V1  
GND (note1)  
Neutral  
Line  
GND (note1)  
Neutral  
Line  
Line  
Note 1: Leading pin (pregrounded)  
4
H SERIES AC/DC  
OUTPUT VOLTAGE ADJUSTMENT  
As a standard feature, single output modules offer an adjustable output voltage, identified by the letter “R” in the part number. The output voltage V1 can either be adjusted  
with an external voltage (Vext) or with an external resistor (R1 or R2) to the new value, V1A. The adjustment range of V1A is approximately 0% to 110% of the nominal  
output voltage, V1. For output voltages above the nominal output value, the minimum input voltage must be increased proportionally to the increase in output. For example,  
to increase the output of an H Series power supply to 110% of initial value, the minimum input voltage must be increased by an additional 10%.  
Method 1:  
Adjust output voltage V1A from 0% to 110% of V1 using Vext between +VOLTAGE ADJUST (pin 14) and -VOLTAGE ADJUST (pin 17). NOTE: Values of Vext must be  
between 0.0V and 8.0V.  
Vext X V1  
2.5V  
2.5V X V1A  
V1A = ————— where Vext =———————  
V1  
Voltage Adjustment with external voltage Vext  
Method 2:  
Adjust output voltage V1A from 0% to 100% of V1 using resistor R1 between +VOLTAGE ADJUST (pin 14) and -VOLTAGE ADJUST (pin 17).  
V1 X R1  
R1 + 4000  
4000 X V1A  
V1- V1A  
V1A = —————— where Vext = ———————  
Voltage Adjustment with external resistor R1 or R2  
Method 3:  
Adjust output voltage V1A from 100% to 110% of V1 using resistor R2 between +VOLTAGE ADJUST (pin 14) and output V1 (pin 20).  
4000 x V1A x (V1 -2.5V)  
2.5V X (V1A -V1)  
V1X 2.5V X R2  
R2=  
and V1A=  
2.5V X (R2 + 4000 )-(V1 X 4000 )  
NOTES: To prevent damage, R2 should never be less than ꢀ7k . R inputs of n units with paralleled outputs may be paralleled,  
but if one single external resistor is to be used, its value should be R1/n, or R2/n respectively.  
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,  
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.  
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the  
date manufactured. Specifications are subject to change without notice.  
5
H SERIES AC/DC  
OVERALL SIZE: 6.61" x 4.38" x 1.52" (168.5Mmm x 111.2mm x 38.7mm) WEIGHT: 27.1 OZ. (770gm)  
6

相关型号:

LH2540-2D6

AC-DC Regulated Power Supply Module, 2 Output, 51W, Hybrid,
BEL

LH2540-2D8

AC-DC Regulated Power Supply Module, 2 Output, 51W, Hybrid,
BEL

LH25400-1

Class H/K5 and R Fuse Blocks
LITTELFUSE

LH25400-3

Class H/K5 and R Fuse Blocks
LITTELFUSE

LH254001CR

FUSE BLOK CART 250V 400A CHASSIS
LITTELFUSE

LH254003CR

FUSE BLOK CART 250V 400A CHASSIS
LITTELFUSE

LH2559AAC

Telecom Circuit, 1-Func, PDSO8, SOG-8
INFINEON

LH2559AAC-TR

Telecom Circuit, 1-Func, PDSO8, SOG-8
INFINEON

LH2559AB

Telecom Circuit, 1-Func, PDIP8, DIP-8
INFINEON

LH2559AC

Telecom Circuit, 1-Func, PDSO8, SOG-8
INFINEON

LH25600-1

Class H/K5 and R Fuse Blocks
LITTELFUSE

LH25600-3

Class H/K5 and R Fuse Blocks
LITTELFUSE