MAP110-1005LT [BEL]
AC-DC Regulated Power Supply Module, 1 Output, 110W, Hybrid,;型号: | MAP110-1005LT |
厂家: | BEL FUSE INC. |
描述: | AC-DC Regulated Power Supply Module, 1 Output, 110W, Hybrid, |
文件: | 总5页 (文件大小:209K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
MAP110 AC-DC Series Data Sheet
Features
•
RoHS lead-solder-exempt compliant
•
New 3.3 V and 5 V output models
•
•
Universal input 85-264 VAC
Industry-standard footprint: 7.00" x 4.30" x 1.97"
(177.8mm x 109.2mm x 50.0mm)
•
•
•
Input transient & ESD compliance to EN61000-4-2/-3/-4
Greater than 134,000 hours MTBF
Remote sense and overvoltage protection on single
output units and main output of multiple output units
•
Options include overtemperature protection,
Power Fail signal, chassis, & cover
Description
Power-One’s MAP110 Series of power supplies combines low cost and universal input in a board-only power solution to meet
commercial and industrial requirements. Full international safety, EMI, and ESD compliance ensure worldwide acceptance. All units
bear the CE Mark.
Wide dynamic output current and fixed-frequency operation simplifies system level operation. The MAP110 series is configured to an
international standard footprint. Input and output connections are made via popular single-row Molex connectors.
Single output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage
requirements.
Single-Output Model Selection
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
CONVECTION COOLED
OUTPUT CURRENT
FORCED AIR
OUTPUT CURRENT
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 1)
INITIAL SETTING
ACCURACY
MODEL
MAP110-1005
MAP110-1012 12V/15V
MAP110-1024 24V/28V
5V
4.95V to 5.50V
11.25V to 15.75V
22.8V to 29.2V
16A
22A
0.2%
0.1%
0.1%
1%
0.5%
0.5%
1%
1%
1%
5.09V to 5.11V
11.97V to 12.02V
23.95V to 24.05V
7.5/6A (Note 2)
3.8/3.2A (Note 2)
10/8A (Note 2)
5.0/4.3A (Note 2)
NOTES: 1) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
2) MAP110-1012 output currents are expressed as 12V/15V operation. MAP110-1024 output currents are expressed as 24V/28V operation.
Multiple-Output Model Selection– 80W Convection Cooled, 110W Forced-Air Cooled (200 LFM)
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
CONVECTION COOLED
CURRENT (NOTE 1)
FORCED AIR
CURRENT
LINE
LOAD
RIPPLE & NOISE
%p-p (NOTE 2)
INITIAL SETTING
ACCURACY
MODEL
REGULATION
REGULATION
+5V
+12V
-12V
-5V
4.75V to 5.25V
Fixed
Fixed
Fixed
4.75V to 5.25V
Fixed
Fixed
Fixed
4.75V to 5.25V
Fixed
Fixed
Fixed
4.75V to 5.25V
Fixed
12A/20A PK
5A/9A PK
12A/20A PK
5A/9A PK
0.2%
0.2%
0.2%
0.2%
0.2%
0.1%
0.1%
0.1%
0.2%
0.1%
0.1%
0.1%
0.2%
0.1%
0.1%
0.2%
0.2%
0.1%
0.1%
0.1%
0.5%
1%
1%
1.5%
0.5%
1%
1%
1%
0.5%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
5.09V to 5.11V
11.97V to 12.03V
-11.4V to -12.6V
-4.75V to -5.25V
5.09V to 5.11V
23.94V to 24.06V
-11.4V to -12.6V
11.4V to 12.6V
5.09V to 5.11V
11.97V to 12.03V
-11.4V to -12.6V
11.4V to 12.6V
5.09V to 5.11V
14.96V to 15.04V
-14.3V to -15.7V
-4.75V to -5.25V
5.09V to 5.11V
23.94V to 24.06V
-14.3V to -15.7V
14.3V to 15.7V
MAP110-4000
1A/1.5A PK
1A/1.5A PK
12A/20A PK
3A/4.5A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
5A/7.3A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
3A/4.5A PK
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
3A/4.5A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
5A/7.3A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
3A/4.5A PK
1A/1.5A PK
1A/1.5A PK
+5V
+24V
-12V
+12V
+5V
+12V
-12V
+12V
+5V
MAP110-4001
MAP110-4002
MAP110-4003
MAP110-4004
1%
0.5%
1%
+15V
-15V
-5V
Fixed
Fixed
4.75V to 5.25V
Fixed
1%
1.5%
0.5%
1%
1%
1%
+5V
+24V
-15V
+15V
Fixed
Fixed
APR 04, 2006 revised to JUL 13, 2006
Page 1 of 5
www.power-one.com
MAP110 AC-DC Series Data Sheet
Multiple-Output Model Selection (Cont.) – 80W Convection Cooled, 110W Forced-Air Cooled (200 LFM)
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
CONVECTION COOLED
CURRENT (NOTE 1)
FORCED AIR
CURRENT
LINE
REGULATION
LOAD
REGULATION
RIPPLE & NOISE
%p-p (NOTE 2)
INITIAL SETTING
ACCURACY
MODEL
+5V
+12V
-5V
-12V
+5V
+12V
-12V
+24V
+5V
+12V
-15V
+15V
+12V
+24V
-12V
+5V
4.75V to 5.25V
Fixed
Fixed
Fixed
4.75V to 5.25V
Fixed
Fixed
Fixed
4.75V to 5.25V
Fixed
Fixed
Fixed
11.55V to 12.45V
Fixed
Fixed
Fixed
3.2V to 3.4V
Fixed
Fixed
Fixed
3.2V to 3.4V
Fixed
12A/20A PK
5A/9A PK
1A/1.5A PK
3A/4A PK
12A/20A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
5A/9A PK
12A/20A PK
5A/9A PK
1A/1.5A PK
3A/4A PK
12A/20A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
5A/9A PK
0.2%
0.1%
0.2%
0.3%
0.2%
0.1%
0.1%
0.1%
0.2%
0.1%
0.1%
0.1%
0.2%
0.2%
0.2%
0.2%
0.3%
0.2%
0.1%
0.1%
0.3%
0.2%
0.1%
0.1%
0.5%
2%
1.5%
8%
0.5%
1%
1%
1%
0.5%
1%
1%
1%
0.5%
1%
1%
1.5%
0.7%
1%
1%
1%
0.7%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
0.5%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
5.09V to 5.11V
11.97V to 12.03V
-4.75V to -5.25V
-11.5V to -12.5V
5.09V to 5.11V
11.97V to 12.03V
-11.4V to -12.6V
23.2V to 24.8V
5.09V to 5.11V
11.97V to 12.03V
-14.4V to -15.6V
14.4V to 15.6V
11.96V to 12.03V
23.94V to 24.06V
-11.4V to -12.6V
4.75V to 5.25V
3.29V to 3.31V
4.98V to 5.02V
-11.4V to -12.6V
11.4V to 12.6V
3.29V to 3.31V
4.98V to 5.02V
-4.75V to -5.25V
11.4V to 12.6V
MAP110-4010
MAP110-4011
MAP110-4015
MAP110-4200
1A/1.5A PK
1A/1.5A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
5A/9A PK
4A/4.5A PK
1A/1.5A PK
2A/2.5A PK
12A/20A PK
5A/12A PK
1A/1.5A PK
1A/1.5A PK
12A/15A PK
5A/12A PK
1A/1.5A PK
1A/1.5A PK
4A/4.5A PK
1A/1.5A PK
2A/2.5A PK
15A/20A PK
8A/12A PK
1A/1.5A PK
1A/1.5A PK
15A/20A PK
8A/12A PK
1A/1.5A PK
1A/1.5A PK
+3.3V
+5V
-12V
+12V
+3.3V
+5V
MAP110-4300
(Note 3)
MAP110-4305
-5V
+12V
Fixed
Fixed
(Note 3)
1%
NOTES: 1) Peak loads up to 110 watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 110 watts.
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3) Sum of the output currents of V1 + V2 may not exceed 15 A continuous, 22 A peak.
Model numbers highlighted in yellow or shaded are not recommended for new designs.
Maximum Output Rtating:
MODEL/OUTPUT
OPTION
MULTIPLE OUTPUT
BOARD ONLY
SINGLE OUTPUT
BOARD ONLY
MULTIPLE OUTPUT
‘L’-BRACKET
SINGLE OUTPUT
‘L’-BRACKET
MULTIPLE OUTPUT
‘C’-COVER
SINGLE OUTPUT
C’-COVER
65W/120W
120W
CONVECTION
CONTINUOUS/PEAK
80W/110W
110W
90W/120W
120W
80W/110W
110W
90W/120W
120W
60W/110W
110W
FORCED AIR
200 LFM
Input Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
85
47
85
40
20
NOM
MAX
UNITS
VAC
Hz
VAC
mS
Input Voltage - AC
Input Frequency
Brown Out Protection
Hold-up Time
Continuous input range.
AC input.
Lowest AC input voltage that regulation is maintained with full rated loads.
264
63
Nominal AC input voltage (110 VAC)
50% load:
Full rated load:
Input Current
85 VAC (110W load).
110VAC (110W load).
3.5
2.8
ARMS
Input Protection
Non-user serviceable internally located AC input line fuse.
Inrush Surge Current
Internally limited by thermistor. Vin = 264 VAC (one cycle). 25 °C.
41
25
APK
kHz
Operating Frequency
Switching frequency of main transformer, (fixed frequency).
20
APR 04, 2006 revised to JUL 13, 2006
Page 2 of 5
www.power-one.com
MAP110 AC-DC Series Data Sheet
Output Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Efficiency
Full load, 230 VAC. Varies with distribution of loads among outputs.
65
75
80
%
Minimum Loads
Single output models.
Multiple output models, V1 + V2 (Note 1).
0
1
Amps
Amps
Ripple and Noise
Output Power
Full Load, 20 MHz Bandwidth.
Multiple output units with convection cooling.
Multiple output units with 200 LFM forced air cooling.
See Model Selection Chart.
5
5
80
Watts
Watts
110
Overshoot / Undershoot
Regulation
Output voltage overshoot/undershoot at turn-on.
0
V
Varies by output, regulation includes: line changes from 90-132
VAC or 175-264, changes in load starting at 20% load and changing
to 100% load.
See Model Selection Chart.
Transient Response
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output only on multiple output units).
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
500
µS
Sec
mS
Turn-on Delay
Turn-on Rise Time
1
20
Interface Signals and Internal Protection
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Overvoltage Protection
Provided on single output models and the
main output of multiple output models.
MAP110-1005
MAP110-1012
MAP110-1024
MAP110-4200
MAP110-4300
All other models.
6.10
17.3
32.2
13.8
3.7
7.20
20.2
37.8
16.2
4.35
6.75
V
5.75
Overload Protection
Remote Sense
Input Power Fail
Warning
Fully protected against output overload and short circuit.
Automatic recovery upon removal of overload condition.
Voltage drop compensated for at the load.
Option, TTL compatible logic signal. Time before regulation dropout due
to loss of input power at 110 VAC. Active low.
150
5
200
%
250
mV
mS
3
Overtemperature Protection
Option, system shutdown due to excessive internal temperature.
Safety, Regulatory, and EMI Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Agency Approvals
UL1950.
CSA 22.2 No. 234/950.
EN60950 (TUV).
Approved.
Dielectric Withstand Voltage
Input to Output.
2600
VDC
Electromagnetic
Interference,
Conducted
FCC CFR title 47 part 15 sub-part B - conducted & radiated.
EN55022 / CISPR 22 conducted.
EN55022 / CISPR 22 radiated (Note 2).
B
B
A
Class
Input Transient Protection
Insulation Resistance
Leakage Current
EN61000-4-5 level 3.
Input to output.
Per EN60950, 264 VAC.
2
10
kV
M⍀
µA
750
NOTES: 1) Minimum load is required only to meet the regulation limits of V3 and V4. If V3 and V4 are unused, no minimum load is necessary.
2) The following units meet Class B: MAP110-1005, MAP110-4000/4011/4015/4200/4300.
APR 04, 2006 revised to JUL 13, 2006
Page 3 of 5
www.power-one.com
MAP110 AC-DC Series Data Sheet
Environmental Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Altitude
Operating.
Non-operating.
10k
50k
ASL Ft.
ASL Ft.
Operating Temperature
Derate linearly above 50°C by 2.5% per° C
to a maximum temperature of 70°C.
At 100% load:
At 50% load:
0
0
50
70
°C
°C
Storage Temperature
Temperature Coefficient
Relative Humidity
-55
85
0.05
95
°C
%/°C
%RH
0°C to 70°C.
Non-condensing.
0.03
Options
DESCRIPTION
NOTES
DIMENSIONS
L-Bracket
Add ‘L’ suffix to model number.
7.15" x 4.50" x 2.40"
(182.0mm x 115.0mm x 61.0mm)
Cover
Add ‘C’ suffix to model number. Includes L-Bracket.
7.20" x 4.50" x 2.40"
(183.0mm x 115.0mm x 61.0mm)
Power Fail
Signal
Add ‘P’ suffix to model number. Provides >5 mS typical warning time before
main output drops 5%. Warning time increases at reduced load levels.
N/A
Thermal
Shutdown
Add ‘T’ suffix to model number. Initiates shut-down in the event of an overtemperature
condition. Automatic recovery.
N/A
APR 04, 2006 revised to JUL 13, 2006
Page 4 of 5
www.power-one.com
MAP110 AC-DC Series Data Sheet
OVERALL SIZE: 7.00" X 4.30" X 1.97" (177.8mm x 109.2mm x 50.0mm)
OVERALL WEIGHT: 1.3 lb (0.59 kg)
NOTE 1
Contact factory for dimensions for L-bracket and cover.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date
manufactured. Specifications are subject to change without notice.
APR 04, 2006 revised to JUL 13, 2006
Page 5 of 5
www.power-one.com