The MBC225 Series of open-frame medical power supplies, with its
wide universal 90-264VACinput range, is available at225 W of output
power and a variety of single and multiple output voltages.
The MBC series is designed and approved to the latest Medical
standards (EN/IEC 60601-1), providing 2 x MOPP isolationfor Class I
& Class II applications.
These power supplies are ideal for medical, telecom, datacom,
industrial equipment and other applications.
Key Features & Benefits
•
•
•
•
•
•
•
•
•
•
•
2 x 4 x 1 Inch Form Factor
225 W with Forced Air Cooling
Approved to EN/IEC 60601-1
Efficiencies up to 94%
-40 to 70 °C Operating Temperature
Dual Fusing
12 V Fan Output, Thermal Shut-Down Feature
3.37 Million Hours, Telcordia - SR332-Issue 3 MTBF
Standby Power <0.5 W
Medical (BF) Safety Approvals
RoHS Compliant
Applications
•
•
•
Diagnostic
Drug Pump
Monitoring
•
•
•
Dialysis
Home Health Care
Portable Equipment
2
MBC225 Series
1. MODEL SELECTION
MAX. LOAD
POWER
MODELNUMBER 1
DESCRIPTION
VOLTAGE
CONVECTION 50˚C
CONVECTION 40˚C
13 CFM
(225 W)
(112.5 W)
(120 W)
MBC225-1T12L
MBC225-1012L
MBC225-1T15L
MBC225-1015L
MBC225-1T24L
MBC225-1024L
MBC225-1T30L
MBC225-1030L
MBC225-1T48L
MBC225-1048L
MBC225-1T58L
MBC225-1058L
Screw Terminal
Molex Connector
Screw Terminal
Molex Connector
Screw Terminal
Molex Connector
Screw Terminal
Molex Connector
Screw Terminal
Molex Connector
Screw Terminal
Molex Connector
12 V
15 V
24 V
30 V
48 V
58 V
9.37 A
7.50 A
4.68 A
3.75 A
2.34 A
1.94 A
10.00 A
8.00 A
5.00 A
4.00 A
2.50 A
2.07 A
18.75 A
15.00 A
9.37 A
7.50 A
4.68 A
3.88 A
225 W
225 W
225 W
225 W
225 W
225 W
COVER-225-XBC2
Metal cover kit (accessory)
1
Class II version available. Add suffix “-2” at the end of the Model Number
When used in Cover Kit, de-rate output power to 70 % under alloperating conditions.
2
2. INPUT SPECIFICATIONS
Specifications are for nominal input voltage, 25°C unless otherwise stated.
PARAMETER
Input Voltage
Input Frequency
Input Current
DESCRIPTION / CONDITION
SPECIFICATION
Universal
85 – 264 VAC / 390 VDC
(Derate from 100% at 100 VAC to 90% at 85 VAC)
47 – 63 Hz
115 VAC:
230 VAC:
2.2 A max.
1.1 A max.
No Load Power
Typical
< 0.5 W
115 VAC:
230 VAC:
264 VAC:
25 A
45 A
75 A
Inrush Current
Typical (N.A. For Class II Option)
Touch current:
300 µA
< 100 µA
Leakage Current
Power Factor
With Full Load
> 0.95
PFC:
PWM:
70 to 130 kHz
50 – 80 kHz
Switching Frequency
tech.support@psbel.com
3
MBC225 Series
3. OUTPUT SPECIFICATIONS
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Output Voltage
Refer to Model selection table
From 12 V to 58 V
With 13 CFM
Convection:
48 V:
225 W
Up to 120 W
94%
Output Power3
Efficiency
24 V, 30 V:
12 V, 15 V:
225 W:
93%
92%
10 ms
16 ms
Hold-up Time
110 W:
Line Regulation5
Load Regulation5
Minimum Load
± 0.5%
± 0.5%
0.0 A
25% step load change, at 0.1A/µs slew rate,
50% duty cycle, 50 Hz = 4%
Transient Response
Recovery time < 5 ms
Ripple4, 5
For all outputs
1.0 % max
55 ms
Rise Time
Typical
Set Point Tolerance 5
Output Voltage Adjustment 6
Over Current Protection
Over Voltage Protection
Short Circuit Protection
± 1%
± 3%
>110%
110 to 140%
Hiccup mode
With 13 CFM forced air cooling (100 to 264 VAC)7
225 W
Up to 120 W
Cooling
With natural convection cooling (100 to 264 VAC)8
3
Combined output power of main output, fan supply shall not exceed max. power rating.
Ripple is peak to peak with 20 MHz bandwidth and 10 μF (Electrolytic capacitor) in parallelwith a 0.1 μF capacitor at rated line
voltage and load ranges.
Fan supply output voltage tolerance including set point accuracy, line and load regulation is +/-15 % and ripple and noiseis less
than 10 %. With V1 fully loaded, Vfan need to have min load of20 mA to be within regulation band.
Adjustment potentiometer is located on the SMT side of the PCB
Refer to Mechanical Drawing
4
5
6
7
8
Refer to Derating Curve
4. EMC SPECIFICATIONS
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Conducted Emissions
EN 55011-B, CISPR22-B, FCC PART15-B
Pass
EN 55011 A;
Pass
Level B
Radiated Emissions
with external core (King coreK5B RC 25x12x15-M in input cable)
Input Current Harmonics
Voltage Fluctuation and Flicker
ESD Immunity
EN 61000-3-2
EN 61000-3-3
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
Class D
Pass
Level 4, Criterion A
Level 3, Criterion A
Level 3, Criterion A
Level 3, Criterion A
Level 3, Criterion A
Level 4, Criterion A
Criterion B
Radiated Field Immunity
Electrical Fast Transient Immunity
Surge Immunity
Conducted Immunity
Magnetic Field Immunity
Voltage Dips, Interruptions
North America
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
+1 408 785 5200
© 2020 Bel Power Solutions & Protection
BCD.00555_AG
4
MBC225 Series
5. SAFETY SPECIFICATIONS
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Input to Output: (Medicalapplications)
Input to GND: (Not ApplicableFor Class II Option)
Output to GND: For typeBF
4000 VAC
1500 VAC
1500 VAC
500 VAC
Isolation Voltage
For type B (NotApplicable For Class II Option)
Safety Standard(s)
Agency Approvals
CE mark
EN60601-1, IEC 60601-1 (ed.3), ANSI / AAMI ES 60601 - 1, CSA C22.2 No. 60601-1
Nemko, UL, C-UL
Complies with LVD Directive
6. ENVIRONMENTAL SPECIFICATIONS
PARAMETER
DESCRIPTION / CONDITION
SPECIFICATION
Operating Temperature
-40 to +70°C
-40 to 0°C startup guaranteed, with spec deviation 9
Storage Temperature
Relative Humidity
-40 to +85°C
5% to 95%
Noncondensing
Operating:
16,000 ft
40,000 ft.
3.37 million hours
Altitude
Reliability
9
Nonoperating:
MTBF according to Telcordia -SR332-issue3:
Output ripple can be more than 10% ofthe output voltage.
Forced air cooled load: 225 W up to 50°C
De-rate above 50 °C @ 2.5% per °C
Convection load: 120 W up to 40 °C
De-rate between 40-50 °C @ 0.625% per °C
De-rate above 50 °C @ 2.33% per °C
Power de-rating with Cover Kit
Convection load: 84 W up to 40 °C
De-rate between 40-50 °C @ 0.625% per °C
De-rate above 50 °C @ 2.33% per °C
Figure 1. Derating Curves
tech.support@psbel.com
5
MBC225 Series
Figure 2. Efficiency Graph at 115 VAC
Figure 3. Efficiency Graph at 230 VAC
7. CONNECTOR & PIN DESCRIPTION
CONNECTOR
PIN
DESCRIPTION/CONDITION
MANUFACTURER / PN
Pin 1
Pin 2
Pin 3
AC Line
Not Fitted
AC Neutral
Molex: 26-60-4030
Mating: 09-50-3031; Pins: 08-50-0106
AC Input Connector
J1
Screw Terminal (Option 1)
Molex Connector (Option 2)
Molex: 39357 Series or equivalent
Pin 1,2,3
Pin 4,5,6
V1 +VE
V1 - VE
DC Output Connector
Aux (Fan) Output
J2
J3
Molex: 26-60-4060
Mating: 09-50-3061; Pins: 08-50-0106
AMP :640456-2
Pin 1
Pin 2
FAN +VE
FAN - VE
Mating: 640440-2
8. MECHANICAL SPECIFICATIONS
PARAMETER
Weight
DESCRIPTION/CONDITION
200 g approx.
50.8 x 101.6 x 25.4 mm (2 x 4 x 1 inch)
Dimensions
North America
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
+1 408 785 5200
© 2020 Bel Power Solutions & Protection
BCD.00555_AG
6
MBC225 Series
Figure 4. Mechanical Drawing – Screw Terminal (Option 1)
Figure 5. Mechanical Drawing – Molex Connector (Option 2)
tech.support@psbel.com
7
MBC225 Series
Figure 6. Mechanical Drawing – With Cover Kit
NOTES: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following:
1
2
3
Stand off, used to mount PCB has OD of 5.4 mm max.
Screws, used to fix PCB on stand off, have head dia of 6.0 mm max.
Washer, if used, to have dia of 6.5 mm max.
For more information on these products consult: tech.support@psbel.com
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for useas critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
North America
Asia-Pacific
Europe, Middle East
+86 755 298 85888
+353 61 225 977
+1 408 785 5200
© 2020 Bel Power Solutions & Protection
BCD.00555_AG
相关型号:
©2020 ICPDF网 联系我们和版权申明