The ABS/MBS400 Series of AC-DC power supplies provides up to
400 W of regulated output power through wide input voltage range
90 – 264 VAC in single outputs of 12, 24, 36 or 48 VDC.
The ABS/MBS400 Series comes in a 83.0 x 212.0 x 42.0 mm form
factor, offering 12 and 5 VSB standby outputs and a full set of
protection features. Available control signals include Power Good
(Power_OK), remote On/off (PS_ON) and remote sense (+RS).
The sealed and full potted package allows an IP67 ingress
protection index and can be installed in contact with thermo-
conductive part of the system to transfer heat by conduction.
The ABS400/MBS Series complies with the latest international
safety standards for IT and medical equipment, offering 2x MoPP
protection grade and displays the CE-Mark for the European Low
Voltage Directive (LVD).
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Universal input voltage range (90 – 264 VAC)
Input surge current limiting
400 W rated power (440 W peak up to 10 s)
High efficiency up to 94%
Low stand-by consumption (<0.5 W)
12, 24, 36 and 48 V standard output voltages
Active PFC, EN61000-3-2 compliant (Class C, >25% load).
Low earth / touch leakage current
Over temperature protection, OV, OC and SC protections
Stand by +5 V, 2 A and auxiliary / fan 12 VDC, 1 A outputs.
Remote On / Off signal
Power good and remote sense signals
Sealed, potted package IP67 rated, fits 1U applications
Medical safety approval to IEC 60601-1 3rd edition, 2x MoPP rated
and BF appliances compatible.
•
•
•
•
IT safety approval to UL/IEC 60950-1
Medical version compatible with 4000 m altitude operation
Optional heatsink accessory available (HSKIT-400-XBS)
Suitable for harsh environments
•
•
•
•
•
•
Video Wall Display & Entertainment
Industrial Process Control
Telecommunications
Laboratory Equipment
Test & Measurement Equipment
Medical Applications
2
ABS/MBS400 Series
INPUT VOLTAGE NOM. OUTPUT MAX. OUTPUT
MAX. OUTPUT
CURRENT
[A]
MODEL NUMBER PACKAGE & COOLING
RANGE
[VAC]
VOLTAGE
[VDC]
POWER
[W]
DIMENSIONS
ABS400-1012
MBS400-1012
ABS400-1024
MBS400-1024
ABS400-1036
MBS400-1036
ABS400-1048
MBS400-1048
HSKIT-400-XBS
33.3
16.7
11.1
8.3
Sealed Chassis
Convection / Conduction
90 - 264
90 - 264
90 - 264
90 - 264
12
24
36
48
400
400
400
400
Dimensions without
heatsink:
83.0 x 212.0 x 42.0 mm
3.27 x 8.34 x 1.65 in
Sealed Chassis
Convection / Conduction
Sealed Chassis
Convection / Conduction
Dimensions with
heatsink:
83.0 x 212.0 x 70.1 mm
3.27 x 8.34 x 2.76 in
Sealed Chassis
Convection / Conduction
- Heatsink accessory (optional) Mounting kit includes 4x screws, M4x10, and the thermally conductive graphite sheet
PARAMETER
AC Input Voltage
DC Input Voltage
Input Frequency
DESCRIPTION / CONDITION
MIN
90
NOM
100-240
-
MAX
264
UNIT
VRMS
VDC
PS starts and operates at 90 VAC at all load conditions
170
47
270
50/60
440
Hz
RMS at 180 VAC, maximum load, 50 / 60 Hz
RMS at 90 VAC, maximum load, 50 / 60 Hz
2.5
5.0
Input Current
-
-
A
Inrush Current
Fusing
265 VAC, 25 °C ambient, cold start.
20
6.3
-
A
A
2x Time Lag 6.3 A, 250 V on both L and N
-
-
-
-
-
-
20% rated load
100 % load
90
92
90
94
At 115 VAC
-
Efficiency
%
20% full load
-
At 230 VAC
50 – 100 % full load
-
Power on, 115-230 VRMS, no load
Stand by, 115-230 VRMS, no load
-
-
1
0.4
1.5
0.5
Input Power Consumption
Power Factor
W
-
At full rated load, 115 VAC, 60 Hz and 230 VAC, 50 Hz input voltages
0.95
-
-
Harmonic Current
Fluctuations and Flicker
Complies with EN-61000-3-2 Class C at 230 VAC 50 Hz, load >50 W.
Complies with EN-61000-3-3 at nominal voltages and full load.
Normal conditions, 240 VRMS, 60 Hz.
Leakage Current
300
µA
tech.support@psbel.com
3
ABS/MBS400 Series
PARAMETER
DESCRIPTION / CONDITION
MIN
NOM
MAX
UNIT
-
-
-
-
-
-
-
12
24
36
48
-
-
-
-
-
-
V1 Output Voltage
±0.5% set point accuracy on all outputs
V
W
A
-
All models, convection cooling
All models, conduction cooling / heat sink
All models, peak power (≤ 10 s)
350
400
440
33.3
16.7
11.1
8.3
29.2
14.6
9.7
7.3
V1 Output Power Rating
V1 Output Current
V1: 12 VDC
V1: 24 VDC
V1: 36 VDC
V1: 48 VDC
V1: 12 VDC
V1: 24 VDC
V1: 36 VDC
V1: 48 VDC
* Conduction (with heatsink)
** Convection (without heatsink)
A
V1 Voltage Adjustment Range
V1 Load-Line-Cross Regulation
V1 Line Regulation
±5
-
-
-
-
-
-
%V1
V1 Load: 0 – 33.3 A (12 V)
0 – 16.7 A (24 V)
0 – 11.1 A (36 V)
0 – 8.3 A (48 V)
V2 Load: 0 – 1 A
5VSB Load: 0 – 2 A
VAC: 90 – 264 VRMS
VAC: 90 – 264 VRMS
±2
%V1
%V1
-
±0.1
±5
25% load changes at 1 A/µs
12 V at 2200 µF Load / IOUT> 0.5 A
24 V at 1000 µF Load / IOUT> 0.5 A
36 V at 820 µF Load / IOUT> 0.5 A
48 V at 560 µF Load / IOUT> 0.5 A
5VSB at 560 µF Load / IOUT> 0.1 A
Transient Response
(Voltage Deviation)
V1, 5VSB
%V1
%5VSB
-
All models, Peak-to-peak, 20 MHz BW.
100 nF ceramic and 10µF tantalum to the load.
V1 Ripple & Noise
Start-up Rise Time
-
-
-
1
%V1
ms
90<VIN<264, any load conditions.
5
85
V1 in regulation after PS_ON is asserted
V1 in regulation after AC is applied
5VSB in regulation after AC is applied
200
750
500
Start-up Delay
-
-
-
ms
10
10
10
16
20
35
%V1
%V2
%VSB
Turn-on Overshoot
At 500 mA output current, V1 in regulation within 50 ms.
-
At nominal VIN, 400 W, for all outputs
At nominal VIN, 365 W, for all outputs
At nominal VIN, 200 W, for all outputs
-
-
-
-
-
-
Hold-up Time
ms
A
Minimum Load ***
All models; V1, V2 and 5VSB
0
-
-
12 V
24 V
36 V
48 V
-
-
-
-
-
-
-
-
33000
16000
10000
7000
At nominal VIN, 25 °C ambient
Maximum Load Capacitance
µF
Temperature Drift
V2 Output Voltage
-1.2
11.25
-
-
12.5
-
+1.2
mV/°C
V
All versions.
Load on V2: from 5 to 1000 mA
Load on V1: from 0.1 to 16.7 A
13.75
V2 Output Current
V2 Ripple
All models, convection/forced air cooling
Peak-to-Peak measured at 20 MHz Bandwidth.
All models (3% set point accuracy)
1
240
-
A
mV
V
5VSB Output Voltage
-
5
All models, convection cooling
All models, conduction cooling / heat sink
-
-
-
-
1.5
2
5VSB Output Current
A
North America
Asia-Pacific
Europe, Middle East
+1 408 785 5200
+86 755 298 85888
+353 61 225 977
© 2020 Bel Power Solutions & Protection
BCD.01062_A
4
ABS/MBS400 Series
V1 Load: 0 – 33.3 A (12 V)
0 – 16.7 A (24 V)
0 – 11.1 A (36 V)
0 – 8.3 A (48 V)
5VSB Load-Line-Cross
Regulation
VAC: 90 – 264 VRMS
-
-
±5
%5VSB
V2 Load: 0 – 1 A
5VSB Load: 0 – 2 A
Peak-to-Peak measured at 20 MHz Bandwidth.
5VSB Ripple
50
mV
* The combined output power of V1, V2 and 5VSB for all models, when conduction cooled or convection cooled with heat sink
mounted, must not exceed 400 W up to 50 °C, and 300 at 70 °C ambient temperature.
** The combined output power of V1, V2 and 5 VSB for all models, when convection cooled and VIN ≥ 180 VRMS, must not exceed
350 W up to 50 °C, and 240 W at 70 °C ambient temperature. See de-rating curves below.
*** When the load on the main output is less than 100 mA, V2 output voltage might regulate below its minimum value.
Contact Bel for details.
Sealed Box without Heatsink
Sealed Box without Heatsink
Figure 2. Power Derating Curves
tech.support@psbel.com
5
ABS/MBS400 Series
Base signals and controls are accessible from signal connector P204.
SIGNAL
PS_ON
DESCRIPTION / CONDITION
Active low, +5 V TTL signal compatible. Input low voltage
Input high voltage (IIN = 200 µA)
MIN
0
NOM
MAX
2.0
-
UNIT
-
-
V
V
3.0
V1 and V2 disabled when PS_ON is open
5VSB not affected by PS_ON
V1 and V2 enabled with PS_ON connected to RTN
+5 V TTL compatible
P_OK
Logic level low (<10 mA sinking)
-
2.4
0.05
1
-
-
-
-
-
0.7
5
V
V
Logic level high (100 µA sourcing)
Low to high time after V1 in regulation
Power down warning time
0.1
-
s
ms
ms
Active and in regulation after a 90<VAC<264 is applied
5VSB not affected by PS_ON
5VSB output
-
200
Above waveforms are expected with AC Input ON/OFF:
Standby on - Main outputs on
Main output Rise Time
50 ms ≤ T1 ≤ 250 ms
5 ms ≤ T2 ≤ 110 ms
4 ms ≤ T10 ≤ 20 ms
25 ms ≤ T3 ≤ 100 ms
T4 ≥ 1 ms
5 VSB rise time
Main outputs On – P_OK delay
Power down warning 1
Main Output off – Standby off 2
Hold-up time (AC off – P_OK low)
AC_ON - Standby turn on time
T5 ≥ 1.2 s
T6 ≥ 15 ms (115/ 230 VAC)
T7 ≤ 500 ms
North America
Asia-Pacific
Europe, Middle East
+1 408 785 5200
+86 755 298 85888
+353 61 225 977
© 2020 Bel Power Solutions & Protection
BCD.01062_A
6
ABS/MBS400 Series
Above waveforms are expected with PS_ON Signal ON/OFF state change:
Main Output Rise Time
5 ms ≤ T2 ≤ 110 ms
25 ms ≤ T3 ≤ 100 ms
Main Outputs on – P_OK delay
Power down warning 1
1 ms ≤ T4 ≤ 5 ms
T8 ≤ 1 ms
PS_ON - Main Output (off) Timing
PS_ON - Main Output (on) Timing
T9 ≤ 200 ms
1 T4 parameter measurement setup will assume at least 10% of the maximum load on each output.
2 T5 parameter measurement setup will assume 50% of the maximum load on 5VSB
.
PARAMETER
Input Under Voltage
Input Fuse
DESCRIPTION / CONDITION
Auto-recovering, hiccup mode.
2x Time Lag 6.3 A, 250 V on L and N
MIN
60
-
NOM
MAX
-
UNIT
VAC
A
75
-
6.3
At nominal input voltages.
V1: Hiccup mode. auto-recovering.
V2: PTC limiting, auto-recovering.
5VSB: Hiccup mode, auto-recovering.
At nominal input voltages.
V1: Hiccup mode. auto-recovering.
V2: PTC limiting, auto-recovering.
5VSB: Hiccup mode, auto-recovering.
12V
Over Current
110
-
-
-
155
-
%I1MAX
Short Circuit
Over Voltage
24V
48V
110
-
136
%VNOM
5VSB
Shut down, latch-off.
Over Temperature (on primary stage)
Over Temperature (on secondary side)
Shut down, latch off.
-
-
-
-
-
-
Hiccup mode, auto-recovering.
5660
4000
-
-
-
-
VDC
VAC
Isolation Primary to Secondary
Reinforced (2x MoPP)
Isolation Input to Earth
Isolation V1 to V2
Basic (1x MoPP)
Functional
1500
100
VAC
VDC
VAC
-
-
-
-
Isolation Output to Earth
Basic (1x MoPP)
1500
tech.support@psbel.com
7
ABS/MBS400 Series
PARAMETER
DESCRIPTION / CONDITION
PS starts up at -30 °C
See graphs above for output power de-rating against TAmb and VIn.
MIN
-20
-40
-
NOM
MAX
70
UNIT
Operating Temperature Range
Storage Temperature Range
Humidity
-
-
-
-
°C
85
°C
RH, Non-condensing Operating
Non-operating
90
95
%
%
Operating Altitude
-
4000
m
EN 60068-2-27
Shock
Operating: Half sine, 30 g, 18 ms, 3 axes, 6x each (3 positive and 3 negative).
Non-Operating: Half sine, 50 g, 11 ms, 3 axes, 6x each (3 positive and 3 negative).
EN 60068-2-64
Operating: Sine,10 – 500 Hz, 1 g, 3 axes, 1 oct/min., 60 min.
Random, 5 – 500 Hz, 0.02 g2/Hz, 1 gRMS, 3 axes, 30 min.
Non-Operating: 5 – 500 Hz, 2.46 gRMS (0.0122 g2/Hz), 3 axes, 30 min.
Vibration
MTBF
Full Load, 120 VAC, 50 °C ambient 70% Duty cycle, Telcordia Issue 1 400000
-
-
Hours
Convection with or without heat sink and conduction providing an
adequate thermal path between the unit and the external
environment.
Cooling
Case hot spot temperature, Tc, should not exceed 90 °C in any
working condition.
Useful Life
Low line range, 200 W, 40 °C ambient, natural convention.
-
4
-
Years
PERFORMANCE
CLASS
PARAMETER
DESCRIPTION / CONDITION
STANDARD
115 VRMS, 230 VRMS. Maximum load.
4 dB minimum margin
EN 55022 (ITE)
EN 55011 (ISM)
Conducted
B
EN 60601-1-2 (Medical)
At 10 m distance
EN 55022 (ITE)
EN 55011 (ISM)
Radiated
B
EN 60601-1-2 (Medical)
Line Voltage Fluctuation and
Flicker
At 20%, 50% and 100% maximum load.
Nominal input voltages.
EN 61000-3-3
Nominal input voltages.
Output load > 50 W.
Harmonic Current Emission
EN 61000-3-2
C
North America
+1 408 785 5200
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
© 2020 Bel Power Solutions & Protection
BCD.01062_A
8
ABS/MBS400 Series
PARAMETER
DESCRIPTION / CONDITION
STANDARD
TEST LEVEL
CRITERIA
Reference standard for the medical version
EN 60601-1-2
15 kV air discharge, 8 kV contact,
at any point of the system.
3 V/m, 80-1000 MHz, 1 KHz/2 Hz 80% AM.
Dwell time is 3 sec for 2 Hz modulation
Dwell time is 1 sec for 1KHz modulation
±2 kV on AC power port for 1 minute;
±1 kV on signal/control lines
ESD
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
4
3
3
A
A
A
Radiated Field
Electric Fast Transient
± 2kV line to line;
± 4 KV line to earth;
on AC power port; ±0.5 kV for outdoor cables
A
B
Surge
EN 61000-4-5
EN 61000-4-6
3
3
Conducted RF Immunity
3 VRMS, 0,15-80 MHz, 1 KHz/2 Hz 80% AM
A
Dip to 30% for 5 cycle (10 ms)
Dip to 40% for 5 cycles (100 ms)
Dip to 70% for 25 cycles (500 ms)
Drop-out to 5% for 10 ms
EN61000-4-11
EN61000-4-11
EN61000-4-11
EN61000-4-11
EN61000-4-11
A
B
B
B
B
Dips and Interruptions
Interrupts > 95% for 5 s
CERTIFICATION BODY SAFETY STANDARDS
CATEGORY
CSA C22.2 No. 60950-1, UL 60950-1; 2007, 2nd edition
CSA C22.2 No.601.1, ANSI/AAMI ES60601-1 3rd edition
IEC/EN 60950-1 2nd edition
Information Technology Equipment
Medical
Information Technology Equipment
CSA/UL
IEC IECEE
CB Certification
IEC/EN 60601-1 3rd edition
Low Voltage Directive (LDV) 2006/95/EC
Low Voltage Directive (LDV) 2007/47/EC MDD
Medical
Information Technology Equipment
Medical
CE
CONNECTIONS
AC Input
WIRES GAUGE AND LENGTH
ASSIGNMENT
Live (L)
COLOUR/PIN
Brown
3x 18 AWG, black external insulation, 300 V, 105°C,
UL2517 cord, 310 ± 10 mm extension from grommet.
Neutral (N)
Blue
Protective Earth (PE)
Green Yellow
Red
12 V version:
3x (2x) +V1 Output (+V1)
6 x 14 AWG, Style 1015, 600 V, 105°C, 260±10 mm
24, 48 V versions:
4x 14 AWG, Style 1015, 600 V, 105°C, 260±10 mm
DC Output
3x (2x) V1 Return (RTN)
Black
+5 V Stand-by Output (+5VSB
Output Power Good (P_OK)
- Fan Voltage (-V2)
)
Red / 1
Auxiliary Voltages
Control Signals
Green / 2
Brown / 3
Grey / 4
Yellow / 5
Blue / 6
Wires: 8x 22 AWG, black external insulation, 300 V,
105°C, UL2517 cord, 220 ± 10 mm extension from
grommet to connector.
Remote On/Off (PS_ON)
Housed by Connector: Molex 90142-0008
Terminals: Molex 90119-0109 (Tin plating)
+ Terminal Remote Sense (+RS)
Stand-by/Signals Return (RTN)
+ Fan Voltage (+V2)
Mates with Molex 90130-1106 or equivalent.
Terminals: Tin plating termination
White / 7
Black / 8
Stand-by/Signals Return (RTN)
tech.support@psbel.com
9
ABS/MBS400 Series
PARAMETER
DESCRIPTION / CONDITION
1300 g (2.87 lb) – without heatsink
1665 g (3.67 lb) – with heatsink
Weight
83.0 x 212.0 x 42.0 mm (3.27 x 8.34 x 1.65 in) - without heatsink
83.0 x 212.0 x 70.1 mm (3.27 x 8.34 x 2.76 in) - with heatsink
Overall Dimensions
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
North America
Asia-Pacific
Europe, Middle East
+1 408 785 5200
+86 755 298 85888
+353 61 225 977
© 2020 Bel Power Solutions & Protection
BCD.01062_A
相关型号:
©2020 ICPDF网 联系我们和版权申明