MPU150/MDU150 Series Data Sheet  
Features  
RoHS lead free solder and lead solder exempted products  
are available  
Power Factor Correction (PFC) meets EN61000-3-2  
Low-profile height fits 1U constraints  
Dual main outputs provide 3.3V and 5V for mixed mode  
applications  
Single wire current sense on outputs V1 and V2  
Remote sense on outputs V1 and V2  
Overtemperature, overload, and overvoltage protection  
Available with metric or SAE mountings  
Greater than 340,000 Hours MTBF  
MDU150 models have 48VDC input  
Description  
The innovative MPU products incorporate Power Factor Correction (PFC) with a low-profile package designed to meet 1U  
height constraints. The MPU150-4530 and MPU150-4350 provide high current +3.3V and +5V on a single platform to support  
mixed-mode, high-speed digital circuitry. Power-One’s unique dual converter architecture combines high reliability with  
exceptional regulation.  
All multiple output models feature remote sense on outputs V1 and V2 to provide independent compensation of output cable  
losses. Other standard features include independent current sharing on V1 and V2, thermal shutdown, and remote inhibit.  
Airflow of 300 linear feet per minute (LFM) is required to deliver the full power density of 3.0 watts per cubic inch.  
The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.  
AC Input, Single Output Model Selection - 180W WITH 300 LFM FORCED-AIR COOLING  
OUTPUT  
VOLTAGE  
ADJUSTMENT  
RANGE  
MAXIMUM OUTPUT  
CURRENT (NOTE 1)  
LINE  
REGULATION  
LOAD  
REGULATION  
RIPPLE & NOISE  
%p-p (NOTE 2)  
INITIAL SETTING  
ACCURACY  
MODEL  
MPU150-S259  
MPU150-S262  
MPU150-S261  
12V  
24V  
48V  
11.6V to 16V  
22.8V to 29.2V  
45V to 56V  
15A (Note 3)  
7.5A (Note 3)  
3.75A (Note 3)  
0.1%  
0.1%  
0.1%  
1%  
1%  
1%  
1%  
1%  
1%  
11.97V to 12.03V  
23.95V to 24.05V  
47.9V to 48.1V  
Model numbers highlighted in yellow or shaded are not recommended for new designs. See MPU200 for new designs.  
AC Input, Multiple Output Model Selection - 150W WITH 300 LFM FORCED-AIR COOLING  
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS  
OUTPUT  
VOLTAGE  
ADJUSTMENT  
RANGE  
OUTPUT  
CURRENT (NOTE 1)  
LINE  
REGULATION  
LOAD  
REGULATION  
RIPPLE & NOISE  
%Pk-Pk (NOTE 2)  
INITIAL SETTING  
ACCURACY  
MODEL  
+3.3V  
+5V  
+12V  
+5V  
+12V  
+24V  
+5V  
+12V  
12V  
3.15V to 3.80V  
5.0V to 5.5V  
Fixed  
5.0V to 5.5V  
10.8V to 13.2V  
Fixed  
35A  
20A  
2A  
17.5A  
4A  
0.6%  
0.4%  
0.4%  
0.4%  
0.4%  
0.4%  
0.4%  
0.4%  
0.4%  
0.4%  
0.8%  
0.6%  
0.4%  
0.4%  
0.6%  
0.4%  
0.4%  
0.4%  
0.4%  
0.6%  
0.4%  
0.4%  
1.5%  
3%  
3%  
1%  
3%  
3%  
1%  
1%  
1%  
1%  
2%  
1.5%  
1%  
1%  
1.5%  
1%  
7%  
7%  
1%  
1.5%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
2%  
1.5%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1.5%  
1%  
1%  
3.28V to 3.32V  
4.98V to 5.02V  
11.76V to 12.24V  
4.98V to 5.02V  
11.94V to 12.06V  
23.52V to 24.48V  
4.98V to 5.02V  
11.94V to 12.06V  
11.94V to 12.06V  
4.98V to 5.02V  
2.49V to 2.51V  
3.28V to 3.32V  
11.94V to 12.06V  
4.98V to 5.0V  
3.28V to 3.32V  
5.00V to 5.04V  
11.94V to 12.06V  
11.94V to 12.06V  
4.98V to 5.02V  
3.28V to 3.32V  
11.94V to 12.06V  
11.94V to 12.06V  
MPU150-3300  
MPU150-3524  
MPU150-4000  
2A  
5.0V to 5.5V  
10.8V to 13.2V  
10.8V to 13.2V  
5.0V to 5.5V  
2.25V to 3.0V  
3.15V to 3.8V  
10.8V to 13.2V  
5.0V to 5.5V  
3.15V to 3.80V  
5.0V to 5.5V  
10.8V to 13.2V  
10.8V to 13.2V  
5.0V to 5.5V  
3.15V to 3.60V  
10.8V to 13.2V  
10.8V to 13.2V  
30A (Note 4)  
8A  
3A  
2A  
5V  
+2.5V  
+3.3V  
12V  
5V  
+3.3V  
+5V  
12V  
12V  
+5V  
+3.3V  
12V  
30A (Note 4)  
15A (Note 4)  
4A (Note 5)  
2A (Note 5)  
30A (Note 4)  
15A (Note 4)  
3A (Note 5)  
3A (Note 5)  
30A (Note 4)  
15A (Note 4)  
3A (Note 5)  
3A (Note 5)  
MPU150-4230  
MPU150-4350  
MPU150-4530  
1.5%  
7%  
7%  
12V  
NOTES: 1) The MPU/MDU150 products require a minimum of 300 LFM of forced-air cooling under  
ALL load conditions. It is recommended that the airflow be applied from the input side of the  
power supply blowing towards the output.  
4) Total current between V1 and V2 is 30A, maximum rating.  
5) Total current between V3 and V4 is 5A, maximum rating.  
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.  
3) Total power of 180 Watts.  
MCD10009 Rev. 1.0, 15-Oct-07  
Page 1 of 6  
www.power-one.com  
MPU150/MDU150 Series Data Sheet  
DC Input Model Selection -  
150W WITH 300 LFM FORCED-AIR COOLING  
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS  
OUTPUT  
MODEL  
ADJUSTMENT  
RANGE  
OUTPUT  
CURRENT (NOTE 1)  
LINE  
REGULATION  
LOAD  
REGULATION  
RIPPLE & NOISE  
%Pk-Pk (NOTE 2)  
INITIAL SETTING  
ACCURACY  
VOLTAGE  
+3.3V  
3.15V to 3.80V  
5.0V to 5.5V  
N/A  
35A  
20A  
2A  
0.6%  
0.4%  
0.4%  
0.4%  
0.4%  
0.4%  
0.4%  
2%  
1.5%  
1%  
1%  
1.5%  
1%  
7%  
1.5%  
3%  
3%  
1%  
1%  
1%  
1%  
2%  
1.5%  
1%  
1%  
1.5%  
1%  
7%  
7%  
1.5%  
1%  
1%  
1%  
1%  
1%  
1%  
2%  
1.5%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
3.28V to 3.32V  
4.98V to 5.02V  
11.76V to 12.24V  
4.98V to 5.02V  
11.94V to 12.06V  
11.94V to 12.06V  
4.98V to 5.02V  
2.49V to 2.51V  
3.28V to 3.32V  
11.94V to 12.06V  
4.98V to 5.0V  
3.28V to 3.32V  
5.00V to 5.04V  
11.94V to 12.06V  
11.94V to 12.06V  
4.98V to 5.02V  
MDU150-3300  
MDU150-4000  
+5V  
+12V  
+5V  
+12V  
12V  
5.0V to 5.5V  
10.8V to 13.2V  
10.8V to 13.2V  
5.0V to 5.5V  
2.25V to 3.0V  
3.15V to 3.8V  
10.8V to 13.2V  
5.0V to 5.5 V  
3.15V to 3.8V  
5.0V to 5.5V  
10.8V to 13.2V  
10.8V to 13.2V  
5.0V to 5.5V  
30A (Note 3)  
8A  
3A  
2A  
5V  
+2.5V  
+3.3V  
12V  
5V  
+3.3V  
+5V  
12V  
12V  
+5V  
30A (Note 3)  
15A (Note 3)  
3A  
MDU150-4230  
MDU150-4350  
2A  
30A (Note 5)  
15A (Note 5)  
3A (Note 4)  
3A (Note 4)  
30A (Note 3)  
7%  
0.4%  
1%  
+3.3V  
12V  
12V  
3.15V to 3.60V  
10.8V to 13.2V  
10.8V to 13.2V  
15A (Note 3)  
3A (Note 4)  
3A (Note 4)  
0.6%  
0.4%  
0.4%  
1.5%  
7%  
7%  
1.5%  
1%  
1%  
3.28V to 3.32V  
11.94V to 12.06V  
11.94V to 12.06V  
MDU150-4530  
NOTES: 1) The MPU/MDU150 products require a minimum of 300 LFM of forced-air cooling  
under ALL load conditions. It is recommended that the airflow be applied from the  
input side of the power supply blowing towards the output.  
4) Total current between V3 and V4 is 5A, maximum rating.  
5) Total current between V1 and V2 is 40A, maximum rating  
2) Maximum peak-to-peak noise expressed as a percentage of output voltage,  
20 MHz bandwidth.  
3) Total current between V1 and V2 is 30A, maximum rating.  
Ordering Information:  
OPTIONS  
SUFFIXES TO ADD TO PART NUMBER  
Metric Mounting  
Add “M” as a suffix to the model number to order chassis with M4 x 0.7 mounting inserts. Metric mounting  
inserts are standard for single-output models MPU150-S259, MPU150-S261, and MPU150-S262.  
RoHS lead solder exemption  
No RoHS suffix character required.  
RoHS compliant for all 6 substances  
Add “G” as the last character of the part number.  
MPU150 Input Specifications  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
85  
47  
17.5  
20  
NOM  
MAX  
264  
63  
UNITS  
VAC  
Hz  
Input Voltage - AC  
Input Frequency  
Hold-up Time  
Continuous input range.  
AC input.  
After last AC line peak at 150 watts.  
MPU150-4350  
All other models  
MPU150  
ms  
Input Current  
85 VAC at full rated load.  
3.0  
35  
ARMS  
Input Protection  
Inrush Surge Current  
Power Factor  
Non-user serviceable internally located AC input line fuse.  
Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C.  
Per EN61000-3-2.  
Switching frequency of main output transformer.  
Switching frequency of secondary transformer.  
Switching frequency of Power Factor Correction circuit.  
APK  
W/VA  
0.95  
100  
65  
Operating Frequency  
120  
90  
kHz  
60  
MCD10009 Rev. 1.0, 15-Oct-07  
Page 2 of 6  
www.power-one.com  
MPU150/MDU150 Series Data Sheet  
MDU150 Input Specifications  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
36  
34  
20  
NOM  
MAX  
UNITS  
VDC  
VDC  
ms  
Input Voltage - DC  
Brown Out Protection  
Hold-up Time  
Continuous input range.  
Lowest DC input voltage that regulation is maintained with full rated loads.  
At 150 watts, over DC input range.  
75  
Input Current  
36 VDC at full rated load.  
6.4  
ARMS  
Input Protection  
Operating Frequency  
Non-user serviceable internally located AC input line fuse.  
Switching frequency of main output transformer.  
Switching frequency of secondary transformer.  
Consult factory.  
100  
70  
kHz  
Inrush Current  
Output Specifications  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Efficiency  
Full Rated Load, 110 VAC. Varies with distribution of loads among outputs.  
65  
75  
%
Minimum Load, V1  
Minimum load required to maintain regulation on,  
V2 at maximum load.  
Minimum load required on single output models.  
Triple output models V1  
Quad output models V1  
Single output models V1  
4
3
0
A
A
Minimum Load, V3  
Minimum load required to maintain regulation on  
V4 at maximum load.  
Quad output models V3  
Triple output models V3  
0.3  
0
Ripple and Noise  
Output Power  
Overshoot / Undershoot  
Regulation  
Full load, 20 MHz bandwidth.  
With 300 LFM forced air cooling. (Note 1)  
Output voltage overshoot/undershoot at turn-on.  
Varies by output. Total regulation includes: line changes over the specified.  
input range, changes in load starting at 20% load and changing to 100% load.  
See Model Selection Charts  
150  
Watts  
%
0
3
5
See Model Selection Charts  
Transient Response  
Recovery time, to within 1% of initial set point due to a 50-100% load change,  
5% max. deviation.  
500  
µs  
Turn-on Delay  
Time required for initial output voltage stabilization.  
2
s
Turn-on Rise Time  
Time required for output voltage to rise from 10% to 90%.  
50  
ms  
NOTES: 1) This product is not rated for convection applications.  
Interface Signals and Internal Protection  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Overvoltage Protection  
Latch style overvoltage protection. Available on  
V1, V2, all models, and V3 on all models except  
MPU150-3300.  
2.5V output, V1 3.0  
3.3V output, V1 4.1  
3.3V output, V2 3.8  
5V output, V1, V2 6.0  
3.25  
4.65  
4.2  
6.4  
12V output, V2  
12V output, V3  
MPU150-4350G 3.3V output, V1 4.3  
MPU150-S259 V1 17.0  
14  
14  
16  
19  
4.65  
20.5  
38.0  
62.7  
V
MPU150-S262 V1 32.0  
MPU150-S261 V1 58.0  
Overload Protection  
Overtemperature Protection  
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.  
System shutdown due to excessive internal temperature, automatic reset.  
Output Good Signal,  
Low to High Transition  
TTL compatible signal available for V1. Pull-up resistor is 10k. Signal  
is high when output is above the specified limits. Signal shall remain low  
3.3V 3.16  
5V 4.75  
3.25  
4.90  
11.9  
23.5  
47.0  
for 20 milliseconds following loss of Output Good.  
MPU150-S259 12V 10.5  
MPU150-S262 24V 21.5  
MPU150-S261 48V 43.0  
V
Input Power Fail Warning  
Current Share  
Remote Sense  
Inhibit  
TTL compatible logic signal. Time before regulation dropout due to loss of input  
power. May be used as independent PSOK signal in redundant applications.  
Accuracy of shared current with up to 6 parallel units. Single wire current share  
on V1 and V2 with return via -Sense return.  
Available on V1 and V2. Total voltage compensation for cable losses with  
respect to the main output.  
Output voltage is inhibited by application of an external high (5V) signal.  
5
ms  
%
10  
500  
mV  
MCD10009 Rev. 1.0, 15-Oct-07  
Page 3 of 6  
www.power-one.com  
MPU150/MDU150 Series Data Sheet  
Safety, Regulatory, and EMI Specifications  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Agency Approvals  
UL1950.  
CSA 22.2 NO. 234/950.  
EN60950 (TÜV).  
Approved  
Dielectric Withstand Voltage  
Electromagnetic Interference  
Input to output per EN60950.  
MPU150 2600  
MDU150 1544  
VDC  
FCC CFR title 47 Part 15 Sub-Part B - Conducted.  
EN55022 / CISPR 22 Conducted.  
B
B
Class  
ESD Susceptibility  
Radiated Susceptibility  
EFT/Burst  
Per EN61000-4-2, level 4.  
Per EN61000-4-3, level 3.  
Per EN61000-4-4, level 3.  
Per EN61000-4-5, class 3.  
8
10  
2
1
2
kV  
V/M  
kV  
Input Transient Protection  
MPU150:  
MPU150:  
MDU150:  
MDU150:  
Line to Line  
Line to Ground  
kV  
Line to Line 0.5  
Line to Ground 0.5  
Insulation Resistance  
Leakage Current  
Input to output.  
Per EN60950.  
10  
M⍀  
Dual output MPU150 at 264 VAC  
Single and triple output MPU150 at 264 VAC  
MDU150 at 72 VDC  
22  
1.7  
mA  
(Not required by EN60950)  
Environmental Specifications  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Altitude  
Operating.  
Non-Operating.  
10k  
40k  
ASL Ft.  
ASL Ft.  
Operating Temperature  
At 100% load  
At 50% load  
0
0
50  
70  
°C  
°C  
Derate linearly above 50°C by 2.5% per °C.  
Storage Temperature  
Temperature Coefficient  
Relative Humidity  
Shock  
-55  
85  
0.05  
95  
20  
6
°C  
0°C to 70°C (after 15 minute warm-up).  
Non-Condensing.  
Peak acceleration.  
0.02  
%/°C  
%RH  
GPK  
5
Vibration  
Random vibration, 10Hz to 2kHz, 3 axis.  
GRMS  
Options  
DESCRIPTION  
NOTES  
SIZE IMPACT  
Metric Mounting  
Add “M” as a suffix to the model number to order chassis with  
M4 x 0.7 mounting inserts. Metric mounting inserts are standard for  
single-output models MPU150-S259, MPU150-S261, and MPU150-S262.  
8.00" x 4.20" x 1.50"  
(203.2mm x 106.7mm x 38.1mm)  
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components  
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective  
divisional president of Power-One, Inc.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date  
manufactured. Specifications are subject to change without notice.  
MCD10009 Rev. 1.0, 15-Oct-07  
Page 4 of 6  
www.power-one.com  
MPU150/MDU150 Series Data Sheet  
Overall Size: 8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm) Weight: 1.8 lb (0.82 kg)  
OUTPUTS:  
SINGLE OUTPUT  
8-32 SCREW  
CONNECTIONS  
(4PL)  
+V1  
RTN  
INTERFACE CONNECTIONS (J300)  
PIN  
V1,V.  
10. +S, V1  
9. -S, V1  
ADJ.  
J1  
INPUT  
L
8. CURRENT SHARE, V1  
7. NO CONNECTION  
N
6. NO CONNECTION  
5. NO CONNECTION  
4. OUTPUT GOOD, V1  
3. POWER FAIL WARNING  
2. INHIBIT  
1. SIGNAL GROUND  
MOLEX SERIES 5268-NA, P/N: 22-05-7105, PINS  
ON 2.50mm CENTERS.  
MATES WITH MOLEX:  
HOUSING SERIES 5264-N, P/N: 50-37-5103 (&)  
PINS SERIES 5263, P/N: 80-70-1040 (LOOSE)  
M4 X 0.7, 8 PLACES.  
MAXIMUM TORQUE: 3.5 IN/LBS (0.40 N/M)  
NOTE:  
MAX. LEAD PROTRUSION IS 0.0625" (1.588mm)  
ON THE FOUR BOTTOM MOUNTING HOLES.  
MAX. LEAD PROTRUSION OF 0.25" (6.25mm)  
IS ACCEPTABLE ON THE FOUR SIDE MOUNTING  
HOLES.  
MOLEX  
SERIES  
41695  
41695  
2139  
PIN  
PINS  
PINS  
WIRE  
CONNECTOR  
J1  
HOUSING  
CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY,  
GAUGE  
SERIES  
(LOOSE)  
(CHAIN)  
09-50-8051  
09-50-8051  
09-50-3051  
6838  
2478  
2478  
08-50-0189  
08-50-0106  
08-50-0106  
08-50-0187  
08-50-0105  
08-50-0105  
18-20AWG  
18-20AWG  
18-20AWG  
WITH CLEAR FINISH  
(ALL MODELS)  
J300  
5264-N  
50-37-5103  
5263  
08-70-1040  
08-70-1039  
22-28AWG  
MCD10009 Rev. 1.0, 15-Oct-07  
Page 5 of 6  
www.power-one.com  
MPU150/MDU150 Series Data Sheet  
Overall Size: 8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm) Weight: 2.0 lb (0.89 kg)  
NOTE:  
MAX. LEAD PROTRUSION IS 0.0625" (1.588mm)  
ON THE FOUR BOTTOM MOUNTING HOLES.  
MAX. LEAD PROTRUSION OF 0.25" (6.25mm)  
IS ACCEPTABLE ON THE FOUR SIDE MOUNTING  
HOLES.  
MOLEX  
SERIES  
PIN  
SERIES  
PINS  
(LOOSE)  
PINS  
(CHAIN)  
WIRE  
GAUGE  
CONNECTOR  
HOUSING  
41695  
41695  
2139  
5051-N  
5051-N  
41695  
41695  
2139  
09-50-8051  
09-50-8051  
09-50-3051  
22-01-1022  
22-01-1022  
09-50-8021  
09-50-8021  
09-50-3021  
09-50-8061  
09-50-8061  
09-50-3061  
50-37-5103  
6838  
2478  
2478  
2759  
2759  
6838  
2478  
2478  
6838  
2478  
2478  
5263  
08-50-0189  
08-50-0106  
08-50-0106  
08-50-0114  
08-65-0805  
08-50-0189  
08-50-0106  
08-50-0106  
08-50-0189  
08-50-0106  
08-50-0106  
08-70-1040  
08-50-0187  
08-50-0105  
08-50-0105  
08-50-0113  
08-65-0804  
08-50-0187  
08-50-0105  
08-50-0105  
08-50-0187  
08-50-0105  
08-50-0105  
08-70-1039  
18-20AWG  
18-20AWG  
18-20AWG  
22-30AWG  
22-30AWG  
18-20AWG  
18-20AWG  
18-20AWG  
18-20AWG  
18-20AWG  
18-20AWG  
22-28AWG  
J1  
CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY,  
WITH CLEAR FINISH  
(ALL MODELS)  
J2  
(TRIPLE OUTPUT)  
J3  
(TRIPLE OUTPUT)  
41695  
41695  
2139  
J3  
(QUAD OUTPUT)  
J300  
5264-N  
MCD10009 Rev. 1.0, 15-Oct-07  
Page 6 of 6  
www.power-one.com  

相关型号:

MDU150-4350MG

AC-DC Power Factor Correction Module,
BEL

MDU150-4530

Power Factor Correction (PFC) Meets EN61000-3-2
POWER-ONE

MDU150-4530G

DC-DC Regulated Power Supply Module, 4 Output, 150W, Hybrid, ROHS COMPLIANT PACKAGE-10
BEL

MDU150-4530M

AC-DC Power Factor Correction Module,
BEL

MDU150-4530MG

AC-DC Power Factor Correction Module,
BEL

MDU1511

Single N-channel Trench MOSFET 30V, 100.0A, 2.4m(ohm)
MGCHIP

MDU1511RH

Single N-channel Trench MOSFET 30V, 100.0A, 2.4m(ohm)
MGCHIP

MDU1512

Single N-channel Trench MOSFET 30V, 100.0A, 3.4m(ohm)
MGCHIP

MDU1512RH

Single N-channel Trench MOSFET 30V, 100.0A, 3.4m(ohm)
MGCHIP

MDU1513

Single N-channel Trench MOSFET 30V, 88.1A, 4.6m(ohm)
MGCHIP

MDU1513URH

Single N-channel Trench MOSFET 30V, 88.1A, 4.6m(ohm)
MGCHIP

MDU1514

Single N-channel Trench MOSFET 30V, 66.3A, 6.0m(ohm)
MGCHIP