MPB150-2024G [BEL]

AC-DC Regulated Power Supply Module, 2 Output, 150W, Hybrid, ROHS COMPLIANT;
MPB150-2024G
型号: MPB150-2024G
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

AC-DC Regulated Power Supply Module, 2 Output, 150W, Hybrid, ROHS COMPLIANT

文件: 总5页 (文件大小:970K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
The MPB150 Series incorporates patented high  
efficiency circuitry, high power density and  
active Power Factor Correction (PFC) to meet  
the requirements of networking and data  
ommunications systems, as well as commercial  
industrial configurations.  
MPB150’s deliver a regulated main output plus a  
second 12V output for fans or other system  
functions. The MPB150 is rated for convection  
as well as forced-air cooling. Full output power  
is available with as few as 15 Cubic Feet per  
Minute (CFM) forced-air cooling.  
The MPB150 product line is approved to the  
latest international regulatory standards, and  
displays the CE Mark.  
RoHS Compliant for All Six Substances  
High Power Density  
Industry-Standard 3" x 5" Footprint  
Power Factor Correction (PFC) Meets  
EN61000-3-2  
Main Output Remote Sense  
Power Good Signals  
CE Marked to Low Voltage Directive  
Input Transient & ESD Compliance to  
EN61000-4-2/-3/-4/-5  
North America  
+1-866.513.2839  
Asia-Pacific  
+86.755.29885888  
Europe, Middle East  
+353 61 225 977  
tech.support@psbel.com  
© 2015 Bel Power Solutions, Inc.  
BCD.00605_AA  
MPB150 Dual-Output AC-DC Series  
OUTPUT  
MAXIMUM OUTPUT  
TOTAL REGULATION RIPPLE & NOISE 1  
REGULATION  
RANGE  
MODEL  
VOLTAGE [V] CURRENT (AMPS), 130 LFM  
[%]  
% pk-pk  
+12V  
12V  
12.5A  
0.5A  
6.0A  
0.5A  
3.1A  
0.5A  
±3%  
1%  
11.64V to 12.36V  
11.40V to 12.60V  
23.28V to 24.72V  
11.40V to 12.60V  
46.56V to 49.44V  
11.40V to 12.60V  
MPB150-2012G 2, 3, 4  
±5%  
±3%  
±5%  
±3%  
±5%  
1%  
1%  
1%  
1%  
1%  
+24V  
12V  
MPB150-2024G 2, 3, 4  
MPB150-2048G 2, 3, 4  
+48V  
12V  
NOTES:  
1
Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.  
Maximum forced-air output power is 150 watts with 15 CFM airflow.  
Maximum convection output power is 70 watts.  
2
3
4
V2 is isolated from V1 and can be used as a negative or positive output.  
PARAMETER  
CONDITIONS/DESCRIPTION  
Continuous input range  
AC Input  
MIN  
90  
NOM  
MAX  
264  
63  
UNITS  
VAC  
Hz  
Input Voltage- AC  
Input Frequency  
47  
Lowest AC input voltage that regulation is maintained with full rated  
loads  
Brownout Protection  
90  
17  
VAC  
Hold-up Time  
Input Current  
Over full AC input voltage range at full rated load  
90 VAC at full rated load  
ms  
2.2  
ARMS  
Non-user serviceable internally located AC input line fuse, 250 VAC,  
3.15A  
Input Protection  
110VAC:  
220VAC:  
23  
46  
Inrush Surge Current  
Internally limited by thermistor, one cycle, 25°C  
APK  
Power Factor Circuitry  
Operating Frequency  
Active PFC meets requirements of EN61000-3-2  
Switching frequency of main transformer  
45  
kHz  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Full Load, 230VAC. Varies with distribution of loads among outputs.  
Efficiency  
75  
80  
85  
%
V1 load for full regulation on V2. All models operate at no load  
without any damage and meet all specs on V1 above 0 amps.  
Minimum Loads  
5
Watts  
Full load, 20 MHz bandwidth  
Ripple and Noise  
See Model Selection Chart  
Watts  
At 15 CFM forced-air cooling. See Application Note for details.  
Convection: Consult Factory.  
150  
Output Power (Note 1)  
Overshoot /Undershoot  
Output voltage overshoot/undershoot at turn-on  
10  
%
Varies by output. Total regulation includes: line changes from 85-132  
VAC or 170-264 VAC, changes in load starting at 20% load and  
changing to 100% load.  
Regulation  
See Model Selection Chart  
Maximum deviation due to a 25% load change with unit at 75% load.  
Time required for initial output voltage stabilization  
Transient Response  
Turn-on Delay  
3
%
0.2  
0.2  
1.5  
20  
Sec  
ms  
Time required for output voltage to rise from 10% to 90%  
Turn-on Rise Time  
866.513.2839  
tech.support@psbel.com  
© 2015 Bel Power Solutions, Inc.  
BCD.00605_AA  
MPB150 Dual-Output AC-DC Series  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
MPB150-2012G  
MPB150-2024G  
MPB150-2048G  
13.5  
26.9  
57.6  
16.5  
31.1  
62.4  
Overvoltage Protection  
V1 output  
VDC  
Fully protected against output short circuit or overload.  
Automatic recovery upon removal of overload condition.  
Overload Protection  
Remote Sense (Note 1)  
Total (+sense and -sense) voltage compensation for cable losses.  
500  
500  
mV  
AC/DC indicator - This signal indicates the status of the AC input or DC  
outputs. When there is sufficient AC voltage and the outputs are  
operating normally, an open collector signal is provided.  
Turn-On delay time from application of AC:  
Warning time before outputs go out of regulation:  
Warning time before outputs deviate ±10% from the nominal value:  
Sink Current  
50  
5
15  
Power Good Signal  
ms  
20  
30  
mA  
V
Pull-up Voltage  
Provided on dual-output models. Open collector signal intended to drive  
an LED.  
Closed collector occurs when the Power Good Signal is in its open  
Power Supply OK Signal  
Thermal Shutdown  
collector state.  
Sink Current  
20  
30  
mA  
V
Pull-up Voltage  
Protected against overtemperature conditions.  
Unit recovers when overtemperature condition is removed.  
Up to 4 units can be connected in parallel.  
There are some limits for parallel operation. See Applications Note.  
N+1 redundancy is provided. V2 needs an external isolation diode for  
N+1 operation.  
Current Share  
Isolation Diode  
Internal isolation diode is provided on V1.  
NOTES: 1) Negative (-) sense must be connected to output common or load common for proper power supply operation.  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Approved to latest edition of the following standards: UL/CSA60950-1,  
IEC60950-1 and EN60950-1.  
Agency Approvals  
Input to Chassis  
Input to Output (Tested by manufacturer only)  
2121  
4242  
VDC  
VDC  
Dielectric Withstand Voltage  
Electromagnetic Interference EN55022 Conducted. Class A  
6
8
dB  
kV  
ESD Susceptibility  
Flicker  
Per EN61000-4-2, Level 4  
Per EN61000-3-3  
Radiated Susceptibility  
EFT/Burst  
Per EN61000-4-3  
3
V/m  
kV  
Per EN61000-4-4  
1
Per EN61000-4-5, Level 3,  
2 kV (Line-to-Gnd) minimum, 1 kV (Line-to-Line) minimum.  
Input Transient Protection  
RF Immunity  
Per EN61000-4-6. 0.15 to 80 MHz (1 kHz sinewave)  
Per EN61000-4-8  
3
1
V/m  
A/m  
Magnetic Fields  
Voltage Dips  
Per EN61000-4-11  
MΩ  
Insulation Resistance  
Leakage Current  
Input to output.  
10  
Per EN60950 (264 VAC)  
1.0  
mA  
866.513.2839  
tech.support@psbel.com  
© 2015 Bel Power Solutions, Inc.  
BCD.00605_AA  
MPB150 Dual-Output AC-DC Series  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Operating  
Non-Operating  
10K  
50K  
50  
Altitude  
ASL Feet  
°C  
Derate linearly from 50 to 70°C to 50% power at 70°C. At 100% load:  
MPB150 models will operate at -20°C, but will not meet all  
specifications.  
0
Operating Temperature  
Storage Temperature  
-40  
85  
°C  
Forced-air cooling of 15 CFM is required for full output power. Air  
velocity is measured with power supply mounted on 0.375" (9.5mm)  
standoffs.  
Forced-Air Cooling  
Airflow direction is from the input section to the output section.  
See Application Note for details.  
Temperature Coefficient  
Relative Humidity  
Included in total regulation of outputs.  
Non-Condensing  
5
85  
%RH  
Gpk  
Operating: 11 ±3ms, 3 axes, Half Sine  
Non-operating: 11 ±3ms, 3 axes, Half Sine  
15  
40  
Shock  
Operating: Random vibration, 5-500 Hz, 10 minutes each axis.  
Non-Operating: Random vibration, 5-500 Hz, 10 minutes each axis.  
2.4  
6.0  
Vibration  
GRMS  
Figure 1 - Mechanical Drawing MBP150 (-2012G, -2024G & -2048G Models)  
866.513.2839  
tech.support@psbel.com  
© 2015 Bel Power Solutions, Inc.  
BCD.00605_AA  
MPB150 Dual-Output AC-DC Series  
MPB150-2012G, -2024G, -2048G  
Housing  
Pins  
09-50-8031  
08-52-0113  
09-50-8061  
08-52-0113  
22-01-3067  
08-50-0114  
22-01-3027  
08-50-0114  
J1  
J2  
J3  
J4  
Housing  
Pins  
Housing  
Pins  
Housing  
Pins  
NOTE: Part numbers are MOLEX; equivalents are acceptable.  
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support  
systems, equipment used in hazardous environments, or nuclear control systems.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending  
on the date manufactured. Specifications are subject to change without notice.  
866.513.2839  
tech.support@psbel.com  
© 2015 Bel Power Solutions, Inc.  
BCD.00605_AA  

相关型号:

MPB150-2048G

Dual-Output AC-DC Series
POWER-ONE

MPB150-2048G

AC-DC Regulated Power Supply Module, 2 Output, 150W, Hybrid, ROHS COMPLIANT