MPU200-1024G [BEL]

Power Factor Correction (PFC);
MPU200-1024G
型号: MPU200-1024G
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

Power Factor Correction (PFC)

功率因数校正
文件: 总7页 (文件大小:1033K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
The MPU200/MDU200 Series is based upon the proven architecture  
of the MPU150/MDU150 product line. The MPU products incorporate  
Power Factor Correction (PFC) with a low-profile package designed  
to meet 1U height constraints. In this series, 200 watts of continuous  
output power is provided with single or multiple output units suited  
for distributed power or central power applications. The series  
provides high current +3.3V and +5V on a single platform to support  
mixed-mode, high-speed digital circuitry.  
The Bel Power Solutions dual-converter architecture combines high  
reliability with exceptional regulation. All multiple-output models  
feature remote sense on outputs V1 and V2 to provide independent  
compensation of output cable losses.  
Other standard features include independent current sharing on V1  
and V2 quad-model outputs, thermal shutdown, and remote inhibit.  
Airflow of 300 linear feet per minute (LFM) is required to deliver the  
full power density of greater than 4.0 watts per cubic inch.  
RoHS Compliant  
Power Factor Correction (PFC)  
Same size, airflow, and construction as MPU150/MDU150 with over  
33% more power  
Single-wire current sense on quad model outputs V1 and V2  
Remote sense on quad model outputs V1 and V2  
Current share and N+1 redundancy (standard on all models)  
Overtemperature, overload, and overvoltage protection  
Available with SAE mountings  
MDU200 models have 48 VDC input  
Asia-Pacific  
Europe, Middle East  
North America  
+86 755 298 85888  
+353 61 225 977  
+1 866 513 2839  
© 2015 Bel Power Solutions, Inc.  
BCD.00604_AA  
2
200W/225 W PK with 300 LFM Forced-Air Cooling 1  
MAXIMUM  
PEAK  
RIPPLE &  
NOISE  
OUTPUT  
VOLTAGE  
ADJUSTMENT  
RANGE  
LINE  
REGULATION  
LOAD  
REGULATION  
INITIAL SETTING  
ACCURACY  
MODEL7  
OUTPUT  
OUTPUT  
CURRENT 2  
CURRENT 2  
% pk-pk 3  
MPU200-1012G  
MPU200-1024G  
MPU200-1048G  
12V  
24V  
48V  
11.6V to 16V  
22.8V to 29.2V  
45V to 56V  
17.0A  
8.35A  
4.2A  
19.0A  
9.4A  
4.7A  
0.1%  
0.1%  
0.1%  
1%  
1%  
1%  
1%  
1%  
1%  
11.97V to 12.03V  
23.95V to 24.05V  
47.9V to 48.1V  
200 W with 300 LFM Forced-Air Cooling 1 - Isolated V3 and V4 can be used as positive or negative outputs  
MAXIMUM  
OUTPUT  
RIPPLE &  
NOISE  
OUTPUT  
VOLTAGE  
ADJUSTMENT  
RANGE  
LINE  
LOAD  
INITIAL SETTING  
ACCURACY  
MODEL7  
REGULATION REGULATION  
CURRENT 2  
% pk-pk 3  
+5V  
+3.3V  
12V  
5.0V to 5.5V  
3.15V to 3.60V  
10.8V to 13.2V  
10.8V to 13.2V  
30A 4  
0.4%  
0.6%  
0.4%  
0.4%  
1%  
1.5%  
10%  
10%  
1%  
1.5%  
1%  
4.98V to 5.02V  
3.28V to 3.32V  
15A 4  
MPU200-4530G  
5
8A  
11.94V to 12.06V  
11.60V to 12.40V  
12V  
4A 5  
1%  
200 W with 300 LFM Forced-Air Cooling 1  
MAXIMUM  
PEAK  
RIPPLE &  
NOISE  
OUTPUT  
VOLTAGE  
ADJUSTMENT  
RANGE  
LINE  
REGULATION  
LOAD  
REGULATION  
INITIAL SETTING  
ACCURACY  
MODEL7  
OUTPUT  
OUTPUT  
CURRENT 2  
CURRENT 2  
% pk-pk 3  
MDU200-1012G  
MDU200-1024G6  
MDU200-1048G  
12V  
24V  
48V  
11.6V to 16V  
22.8V to 29.2V  
45V to 56V  
17.0A  
8.35A  
4.2A  
19.0A  
9.4A  
4.7A  
0.1%  
0.1%  
0.1%  
1%  
1%  
1%  
1%  
1%  
1%  
11.97V to 12.03V  
23.95V to 24.05V  
47.9V to 48.1V  
Isolation Diode Option - Offered on single-output models. Add “D” at the end of the part number if an isolation diode is needed.  
NOTES:  
1
This product is not rated for convection applications.  
The MPU/MDU200 products require a minimum of 300 LFM of forced-air cooling under ALL load conditions. It is recommended  
2
that the airflow be applied from the input side of the power supply blowing towards the output.  
Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.  
Total current for V1 and V2 is not to exceed 35A.  
Total power on V3 and V4 is not to exceed 100W.  
Derating is required on output voltages above 27VDC. Consult factory.  
Non-G models use lead solder exemption and are not recommended for new designs.  
3
4
5
6
7
OPTIONS  
SUFFIXES TO ADD TO PART NUMBER  
Add “M” as a suffix to the model number to order chassis with M3 x 0.7 mounting inserts.  
Consult factory for availability.  
Metric Mounting  
Offered on single-output models. Add “D” to the part number suffix if an isolation diode is needed.  
Consult factory for availability.  
Isolation Diode  
RoHS lead solder exempt  
No RoHS suffix character required.  
RoHS compliant for all 6 substances Add “G” as the last character of the part number.  
tech.support@psbel.com  
3
PARAMETER  
CONDITIONS / DESCRIPTION  
Continuous input range.  
MIN  
85  
NOM  
MAX  
264  
63  
UNITS  
VAC  
Hz  
Input Voltage - AC  
Input Frequency  
Hold-up Time  
AC input.  
47  
After last AC line peak at 200 watts  
85 VAC at full rated load.  
15  
ms  
Input Current  
4.0  
35  
ARMS  
Input Protection  
Inrush Surge Current  
Power Factor  
Non-user serviceable internally located AC input line fuse.  
Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C.  
Per EN61000-3-2.  
APK  
0.95  
W/VA  
Switching frequency of main output transformer.  
Switching frequency of secondary transformer.  
Switching frequency of Power Factor Correction circuit.  
100  
65  
120  
90  
Operating Frequency  
kHz  
60  
PARAMETER  
CONDITIONS / DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Input Voltage - DC  
Continuous input range.  
36  
75  
VDC  
Lowest DC input voltage that regulation is maintained with full  
rated loads.  
Brown Out Protection  
34  
15  
VDC  
Hold-up Time  
At 200 watts, over DC input range.  
ms  
Input Current  
36 VDC at full rated load.  
8.35  
ARMS  
Input Protection  
Inrush Surge Current  
Non-user serviceable internally located AC input line fuse.  
Consult factory.  
Switching frequency of main output transformer.  
Switching frequency of secondary transformer.  
100  
70  
Operating Frequency  
kHz  
PARAMETER  
CONDITIONS / DESCRIPTION  
MIN  
NOM  
75  
MAX  
UNITS  
Full Rated Load, 110 VAC (MPU) or 48 VDC (MDU).  
Varies with distribution of loads among outputs.  
Efficiency  
65  
%
Minimum load required to maintain  
regulation on, V2 at maximum load.  
Minimum load required on single  
Single output models V1  
output models.  
Quad output model V1  
3
0
Minimum Load, V1  
Minimum Load, V3  
A
A
Minimum load required to maintain  
regulation on V4 at maximum load.  
Quad output model V3  
0.3  
Ripple and Noise  
Full load, 20 MHz bandwidth.  
See Model Selection Charts  
5
Overshoot / Undershoot  
Output voltage overshoot/undershoot at turn-on.  
%
Varies by output. Total regulation includes: line changes over the  
specified. Input range changes in load starting at 20% load and  
changing to 100% load.  
Regulation  
See Model Selection Charts  
Recovery time, to within 1% of initial set point due to a 50-100%  
load change, 5% max. deviation.  
μs  
s
Transient Response  
Turn-on Delay  
500  
2
Time required for initial output voltage stabilization.  
Time required for output voltage to rise from  
10% to 90%.  
MPU200  
MDU200  
50  
80  
Turn-on Rise Time  
ms  
tech.support@psbel.com  
4
PARAMETER  
CONDITIONS / DESCRIPTION  
MIN  
3.8  
6.0  
14  
17.0  
32.0  
58.0  
NOM  
MAX  
4.2  
6.4  
19  
20.5  
38.0  
62.7  
UNITS  
MPU200-4530G 3.3 V output  
MPU200-4530G 5 V output  
MPU200-4530G 12 V output  
MDU200/MPU200-1012G V1  
MDU200/MPU200-1024G V1  
MDU200/MPU200-1048G V1  
Latch style overvoltage  
protection.  
Overvoltage Protection  
V
Fully protected against output overload and short circuit.  
Automatic recovery upon removal of overload condition.  
Overload Protection  
System shutdown due to excessive internal temperature, automatic  
reset.  
Overtemperature Protection  
TTL compatible signal available for V1.  
Internal pull-up resistor is 475 Ω.  
3.3 V  
5 V  
3.16  
4.75  
3.25  
V
Signal is high when output is above the specified limits.  
Signal shall remain low for 20 ms following loss of Output  
Good.  
4.95  
Output Good Signal  
(Transition from Low to High)  
MDU200/MPU200-1012G 12 V  
MDU200/MPU200-1024G 24 V  
MDU200/MPU200-1048G 48 V  
10.5  
21.5  
43.0  
11.9  
23.5  
47.0  
V
TTL compatible logic signal. Time before regulation dropout due to  
loss of input power. May be used as independent PSOK signal in  
redundant applications.  
Input Power Fail Warning  
5
ms  
Accuracy of shared current with up to 6 parallel units. Single wire  
current share on V1 and V2 with return via Sense return.  
Available on V1 and V2. Total voltage compensation for cable losses  
with respect to the main output.  
Output voltage is inhibited by application of an external high (5 V)  
signal.  
Current Share  
Remote Sense  
Inhibit  
10  
%
500  
mV  
PARAMETER  
CONDITIONS / DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Approved to the latest edition of the following standards:  
CSA/UL60950-1, EN60950-1 and IEC60950-1  
Safety Approvals  
MPU200  
MDU200  
2600  
1414  
Dielectric Withstand Voltage Input to output per EN60950.  
VDC  
FCC CFR title 47 Part 15 Sub-Part B - Conducted.  
EN55022 / CISPR 22 Conducted.  
B
B
Electromagnetic Interference  
Class  
ESD Susceptibility  
Radiated Susceptibility  
EFT/Burst  
Per EN61000-4-2, level 4.  
8
kV  
V/M  
kV  
Per EN61000-4-3, level 3.  
Per EN61000-4-4, level 3.  
10  
±2  
MPU200: Line to Line  
MPU200: Line to Ground  
MDU200: Line to Line  
1
2
0.5  
0.5  
Input Transient Protection  
Per EN61000-4-5, class 3.  
Input to Output.  
kV  
MDU200: Line to Ground  
Insulation Resistance  
Leakage Current  
10  
MV  
mA  
MPU200 Quad Output Model  
MPU200 Single Output Models  
MDU200 at 72 VDC (Not required by EN60950)  
2.2  
1.7  
N/A  
Per EN60950.  
tech.support@psbel.com  
5
PARAMETER  
CONDITIONS / DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Operating.  
Non-Operating.  
10k  
40k  
Altitude  
ASL Ft.  
At 100% load  
At 50% load  
0
0
50  
70  
Operating Temperature  
°C  
Derate linearly above 50°C by 2.5% per °C.  
Storage Temperature  
Temperature Coefficient  
Relative Humidity  
Shock  
-55  
85  
±0.05  
95  
°C  
0°C to 70°C (after 15 minute warm-up).  
Non-Condensing.  
±0.02  
%/°C  
%RH  
GPK  
5
Peak acceleration.  
20  
Vibration  
Random vibration, 10 Hz to 2 kHz, 3 axis.  
6
GRMS  
PARAMETER  
CONDITIONS / DESCRIPTION  
Add “M” as a suffix to the model number to order chassis with M3 x 0.7 mounting  
inserts. Consult factory for availability.  
Metric Mounting  
Offered on single-output models. Add “D” to the part number suffix if an isolation  
diode is needed. Consult factory for availability.  
Isolation Diode  
PARAMETER  
Dimensions  
Weight:  
DESCRIPTION  
8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm)  
2 lb (0.89 kg)  
tech.support@psbel.com  
6
Figure 1. Mechanical Drawing Single Output  
CONNECTOR  
MOLEX SERIES  
41695  
HOUSING  
09-50-8051  
09-50-8051  
09-50-3051  
50-37-5103  
PIN SERIES  
6838  
PINS (LOOSE)  
08-50-0189  
08-50-0106  
08-50-0106  
08-70-1040  
PINS (CHAIN)  
08-50-0187  
08-50-0105  
08-50-0105  
08-70-1039  
WIRE GAUGE  
18-20 AWG  
18-20 AWG  
18-20 AWG  
22-28 AWG  
J1  
41695  
2478  
(ALL MODELS)  
2139  
2478  
J300  
5264-N  
5263  
CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY, WITH CLEAR FINISH  
tech.support@psbel.com  
7
Figure 2. Mechanical Drawing Quad Output  
CONNECTOR  
MOLEX SERIES  
HOUSING  
PIN SERIES  
PINS (LOOSE)  
PINS (CHAIN)  
WIRE GAUGE  
41695  
41695  
2139  
09-50-8051  
09-50-8051  
09-50-3051  
22-01-1022  
22-01-1022  
09-50-8021  
09-50-8021  
09-50-3021  
09-50-8061  
09-50-8061  
09-50-3061  
50-37-5103  
6838  
2478  
2478  
2759  
2759  
6838  
2478  
2478  
6838  
2478  
2478  
5263  
08-50-0189  
08-50-0106  
08-50-0106  
08-50-0114  
08-65-0805  
08-50-0189  
08-50-0106  
08-50-0106  
08-50-0189  
08-50-0106  
08-50-0106  
08-70-1040  
08-50-0187  
08-50-0105  
08-50-0105  
08-50-0113  
08-65-0804  
08-50-0187  
08-50-0105  
08-50-0105  
08-50-0187  
08-50-0105  
08-50-0105  
08-70-1039  
18-20AWG  
18-20AWG  
18-20AWG  
22-30AWG  
22-30AWG  
18-20AWG  
18-20AWG  
18-20AWG  
18-20AWG  
18-20AWG  
18-20AWG  
22-28AWG  
J1 (ALL MODELS)  
5051-N  
5051-N  
41695  
41695  
2139  
J2 (TRIPLE  
OUTPUT)  
J3 (TRIPLE  
OUTPUT)  
41695  
41695  
2139  
J3 (QUAD  
OUTPUT)  
J300  
5264-N  
CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY, WITH CLEAR FINISH  
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,  
equipment used in hazardous environments, or nuclear control systems.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on  
the date manufactured. Specifications are subject to change without notice.  
tech.support@psbel.com  

相关型号:

MPU200-1024M

DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, MODULE-10
BEL

MPU200-1024MDG

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, ROHS COMPLIANT PACKAGE-10
BEL

MPU200-1048

Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints
POWER-ONE

MPU200-1048G

Power Factor Correction (PFC)
BEL

MPU200-1048M

DC-DC Regulated Power Supply Module, 1 Output, 200W, Hybrid, MODULE-10
BEL

MPU200-4530

Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints
POWER-ONE

MPU200-4530D

DC-DC Regulated Power Supply Module, 4 Output, 200W, Hybrid, MODULE-10
BEL

MPU200-4530G

DC-DC Regulated Power Supply Module, 4 Output, 200W, Hybrid, ROHS COMPLIANT PACKAGE-10
BEL

MPU200-4530M

DC-DC Regulated Power Supply Module, 4 Output, 200W, Hybrid, MODULE-10
BEL

MPU200-4530MG

DC-DC Regulated Power Supply Module, 4 Output, 200W, Hybrid, ROHS COMPLIANT PACKAGE-10
BEL

MPU250S12yF

MPU-250F Series
MPD

MPU250S12YZ

MPU-250Series
MPD