MPU200-1024G [BEL]
Power Factor Correction (PFC);型号: | MPU200-1024G |
厂家: | BEL FUSE INC. |
描述: | Power Factor Correction (PFC) 功率因数校正 |
文件: | 总7页 (文件大小:1033K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
The MPU200/MDU200 Series is based upon the proven architecture
of the MPU150/MDU150 product line. The MPU products incorporate
Power Factor Correction (PFC) with a low-profile package designed
to meet 1U height constraints. In this series, 200 watts of continuous
output power is provided with single or multiple output units suited
for distributed power or central power applications. The series
provides high current +3.3V and +5V on a single platform to support
mixed-mode, high-speed digital circuitry.
The Bel Power Solutions dual-converter architecture combines high
reliability with exceptional regulation. All multiple-output models
feature remote sense on outputs V1 and V2 to provide independent
compensation of output cable losses.
Other standard features include independent current sharing on V1
and V2 quad-model outputs, thermal shutdown, and remote inhibit.
Airflow of 300 linear feet per minute (LFM) is required to deliver the
full power density of greater than 4.0 watts per cubic inch.
RoHS Compliant
Power Factor Correction (PFC)
Same size, airflow, and construction as MPU150/MDU150 with over
33% more power
Single-wire current sense on quad model outputs V1 and V2
Remote sense on quad model outputs V1 and V2
Current share and N+1 redundancy (standard on all models)
Overtemperature, overload, and overvoltage protection
Available with SAE mountings
MDU200 models have 48 VDC input
Asia-Pacific
Europe, Middle East
North America
+86 755 298 85888
+353 61 225 977
+1 866 513 2839
© 2015 Bel Power Solutions, Inc.
BCD.00604_AA
2
200W/225 W PK with 300 LFM Forced-Air Cooling 1
MAXIMUM
PEAK
RIPPLE &
NOISE
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
LINE
REGULATION
LOAD
REGULATION
INITIAL SETTING
ACCURACY
MODEL7
OUTPUT
OUTPUT
CURRENT 2
CURRENT 2
% pk-pk 3
MPU200-1012G
MPU200-1024G
MPU200-1048G
12V
24V
48V
11.6V to 16V
22.8V to 29.2V
45V to 56V
17.0A
8.35A
4.2A
19.0A
9.4A
4.7A
0.1%
0.1%
0.1%
1%
1%
1%
1%
1%
1%
11.97V to 12.03V
23.95V to 24.05V
47.9V to 48.1V
200 W with 300 LFM Forced-Air Cooling 1 - Isolated V3 and V4 can be used as positive or negative outputs
MAXIMUM
OUTPUT
RIPPLE &
NOISE
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
LINE
LOAD
INITIAL SETTING
ACCURACY
MODEL7
REGULATION REGULATION
CURRENT 2
% pk-pk 3
+5V
+3.3V
12V
5.0V to 5.5V
3.15V to 3.60V
10.8V to 13.2V
10.8V to 13.2V
30A 4
0.4%
0.6%
0.4%
0.4%
1%
1.5%
10%
10%
1%
1.5%
1%
4.98V to 5.02V
3.28V to 3.32V
15A 4
MPU200-4530G
5
8A
11.94V to 12.06V
11.60V to 12.40V
12V
4A 5
1%
200 W with 300 LFM Forced-Air Cooling 1
MAXIMUM
PEAK
RIPPLE &
NOISE
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
LINE
REGULATION
LOAD
REGULATION
INITIAL SETTING
ACCURACY
MODEL7
OUTPUT
OUTPUT
CURRENT 2
CURRENT 2
% pk-pk 3
MDU200-1012G
MDU200-1024G6
MDU200-1048G
12V
24V
48V
11.6V to 16V
22.8V to 29.2V
45V to 56V
17.0A
8.35A
4.2A
19.0A
9.4A
4.7A
0.1%
0.1%
0.1%
1%
1%
1%
1%
1%
1%
11.97V to 12.03V
23.95V to 24.05V
47.9V to 48.1V
Isolation Diode Option - Offered on single-output models. Add “D” at the end of the part number if an isolation diode is needed.
NOTES:
1
This product is not rated for convection applications.
The MPU/MDU200 products require a minimum of 300 LFM of forced-air cooling under ALL load conditions. It is recommended
2
that the airflow be applied from the input side of the power supply blowing towards the output.
Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
Total current for V1 and V2 is not to exceed 35A.
Total power on V3 and V4 is not to exceed 100W.
Derating is required on output voltages above 27VDC. Consult factory.
Non-G models use lead solder exemption and are not recommended for new designs.
3
4
5
6
7
OPTIONS
SUFFIXES TO ADD TO PART NUMBER
Add “M” as a suffix to the model number to order chassis with M3 x 0.7 mounting inserts.
Consult factory for availability.
Metric Mounting
Offered on single-output models. Add “D” to the part number suffix if an isolation diode is needed.
Consult factory for availability.
Isolation Diode
RoHS lead solder exempt
No RoHS suffix character required.
RoHS compliant for all 6 substances Add “G” as the last character of the part number.
tech.support@psbel.com
3
PARAMETER
CONDITIONS / DESCRIPTION
Continuous input range.
MIN
85
NOM
MAX
264
63
UNITS
VAC
Hz
Input Voltage - AC
Input Frequency
Hold-up Time
AC input.
47
After last AC line peak at 200 watts
85 VAC at full rated load.
15
ms
Input Current
4.0
35
ARMS
Input Protection
Inrush Surge Current
Power Factor
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C.
Per EN61000-3-2.
APK
0.95
W/VA
Switching frequency of main output transformer.
Switching frequency of secondary transformer.
Switching frequency of Power Factor Correction circuit.
100
65
120
90
Operating Frequency
kHz
60
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Input Voltage - DC
Continuous input range.
36
75
VDC
Lowest DC input voltage that regulation is maintained with full
rated loads.
Brown Out Protection
34
15
VDC
Hold-up Time
At 200 watts, over DC input range.
ms
Input Current
36 VDC at full rated load.
8.35
ARMS
Input Protection
Inrush Surge Current
Non-user serviceable internally located AC input line fuse.
Consult factory.
Switching frequency of main output transformer.
Switching frequency of secondary transformer.
100
70
Operating Frequency
kHz
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
75
MAX
UNITS
Full Rated Load, 110 VAC (MPU) or 48 VDC (MDU).
Varies with distribution of loads among outputs.
Efficiency
65
%
Minimum load required to maintain
regulation on, V2 at maximum load.
Minimum load required on single
Single output models V1
output models.
Quad output model V1
3
0
Minimum Load, V1
Minimum Load, V3
A
A
Minimum load required to maintain
regulation on V4 at maximum load.
Quad output model V3
0.3
Ripple and Noise
Full load, 20 MHz bandwidth.
See Model Selection Charts
5
Overshoot / Undershoot
Output voltage overshoot/undershoot at turn-on.
%
Varies by output. Total regulation includes: line changes over the
specified. Input range changes in load starting at 20% load and
changing to 100% load.
Regulation
See Model Selection Charts
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 5% max. deviation.
μs
s
Transient Response
Turn-on Delay
500
2
Time required for initial output voltage stabilization.
Time required for output voltage to rise from
10% to 90%.
MPU200
MDU200
50
80
Turn-on Rise Time
ms
tech.support@psbel.com
4
PARAMETER
CONDITIONS / DESCRIPTION
MIN
3.8
6.0
14
17.0
32.0
58.0
NOM
MAX
4.2
6.4
19
20.5
38.0
62.7
UNITS
MPU200-4530G 3.3 V output
MPU200-4530G 5 V output
MPU200-4530G 12 V output
MDU200/MPU200-1012G V1
MDU200/MPU200-1024G V1
MDU200/MPU200-1048G V1
Latch style overvoltage
protection.
Overvoltage Protection
V
Fully protected against output overload and short circuit.
Automatic recovery upon removal of overload condition.
Overload Protection
System shutdown due to excessive internal temperature, automatic
reset.
Overtemperature Protection
TTL compatible signal available for V1.
Internal pull-up resistor is 475 Ω.
3.3 V
5 V
3.16
4.75
3.25
V
Signal is high when output is above the specified limits.
Signal shall remain low for 20 ms following loss of Output
Good.
4.95
Output Good Signal
(Transition from Low to High)
MDU200/MPU200-1012G 12 V
MDU200/MPU200-1024G 24 V
MDU200/MPU200-1048G 48 V
10.5
21.5
43.0
11.9
23.5
47.0
V
TTL compatible logic signal. Time before regulation dropout due to
loss of input power. May be used as independent PSOK signal in
redundant applications.
Input Power Fail Warning
5
ms
Accuracy of shared current with up to 6 parallel units. Single wire
current share on V1 and V2 with return via Sense return.
Available on V1 and V2. Total voltage compensation for cable losses
with respect to the main output.
Output voltage is inhibited by application of an external high (5 V)
signal.
Current Share
Remote Sense
Inhibit
10
%
500
mV
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Approved to the latest edition of the following standards:
CSA/UL60950-1, EN60950-1 and IEC60950-1
Safety Approvals
MPU200
MDU200
2600
1414
Dielectric Withstand Voltage Input to output per EN60950.
VDC
FCC CFR title 47 Part 15 Sub-Part B - Conducted.
EN55022 / CISPR 22 Conducted.
B
B
Electromagnetic Interference
Class
ESD Susceptibility
Radiated Susceptibility
EFT/Burst
Per EN61000-4-2, level 4.
8
kV
V/M
kV
Per EN61000-4-3, level 3.
Per EN61000-4-4, level 3.
10
±2
MPU200: Line to Line
MPU200: Line to Ground
MDU200: Line to Line
1
2
0.5
0.5
Input Transient Protection
Per EN61000-4-5, class 3.
Input to Output.
kV
MDU200: Line to Ground
Insulation Resistance
Leakage Current
10
MV
mA
MPU200 Quad Output Model
MPU200 Single Output Models
MDU200 at 72 VDC (Not required by EN60950)
2.2
1.7
N/A
Per EN60950.
tech.support@psbel.com
5
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Operating.
Non-Operating.
10k
40k
Altitude
ASL Ft.
At 100% load
At 50% load
0
0
50
70
Operating Temperature
°C
Derate linearly above 50°C by 2.5% per °C.
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
-55
85
±0.05
95
°C
0°C to 70°C (after 15 minute warm-up).
Non-Condensing.
±0.02
%/°C
%RH
GPK
5
Peak acceleration.
20
Vibration
Random vibration, 10 Hz to 2 kHz, 3 axis.
6
GRMS
PARAMETER
CONDITIONS / DESCRIPTION
Add “M” as a suffix to the model number to order chassis with M3 x 0.7 mounting
inserts. Consult factory for availability.
Metric Mounting
Offered on single-output models. Add “D” to the part number suffix if an isolation
diode is needed. Consult factory for availability.
Isolation Diode
PARAMETER
Dimensions
Weight:
DESCRIPTION
8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm)
2 lb (0.89 kg)
tech.support@psbel.com
6
Figure 1. Mechanical Drawing – Single Output
CONNECTOR
MOLEX SERIES
41695
HOUSING
09-50-8051
09-50-8051
09-50-3051
50-37-5103
PIN SERIES
6838
PINS (LOOSE)
08-50-0189
08-50-0106
08-50-0106
08-70-1040
PINS (CHAIN)
08-50-0187
08-50-0105
08-50-0105
08-70-1039
WIRE GAUGE
18-20 AWG
18-20 AWG
18-20 AWG
22-28 AWG
J1
41695
2478
(ALL MODELS)
2139
2478
J300
5264-N
5263
CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY, WITH CLEAR FINISH
tech.support@psbel.com
7
Figure 2. Mechanical Drawing – Quad Output
CONNECTOR
MOLEX SERIES
HOUSING
PIN SERIES
PINS (LOOSE)
PINS (CHAIN)
WIRE GAUGE
41695
41695
2139
09-50-8051
09-50-8051
09-50-3051
22-01-1022
22-01-1022
09-50-8021
09-50-8021
09-50-3021
09-50-8061
09-50-8061
09-50-3061
50-37-5103
6838
2478
2478
2759
2759
6838
2478
2478
6838
2478
2478
5263
08-50-0189
08-50-0106
08-50-0106
08-50-0114
08-65-0805
08-50-0189
08-50-0106
08-50-0106
08-50-0189
08-50-0106
08-50-0106
08-70-1040
08-50-0187
08-50-0105
08-50-0105
08-50-0113
08-65-0804
08-50-0187
08-50-0105
08-50-0105
08-50-0187
08-50-0105
08-50-0105
08-70-1039
18-20AWG
18-20AWG
18-20AWG
22-30AWG
22-30AWG
18-20AWG
18-20AWG
18-20AWG
18-20AWG
18-20AWG
18-20AWG
22-28AWG
J1 (ALL MODELS)
5051-N
5051-N
41695
41695
2139
J2 (TRIPLE
OUTPUT)
J3 (TRIPLE
OUTPUT)
41695
41695
2139
J3 (QUAD
OUTPUT)
J300
5264-N
CHASSIS: 0.063" (1.6mm) ALUMINUM ALLOY, WITH CLEAR FINISH
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on
the date manufactured. Specifications are subject to change without notice.
tech.support@psbel.com
相关型号:
MPU200-1048
Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints
POWER-ONE
MPU200-4530
Power Factor Correction (PFC) with a low-profile package designed to meet 1U height constraints
POWER-ONE
MPU200-4530G
DC-DC Regulated Power Supply Module, 4 Output, 200W, Hybrid, ROHS COMPLIANT PACKAGE-10
BEL
MPU200-4530MG
DC-DC Regulated Power Supply Module, 4 Output, 200W, Hybrid, ROHS COMPLIANT PACKAGE-10
BEL
©2020 ICPDF网 联系我们和版权申明