NSR510-9LIPC [BEL]

DC-DC Regulated Power Supply Module, 1 Output, METAL, CASE C03, MODULE-11;
NSR510-9LIPC
型号: NSR510-9LIPC
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

DC-DC Regulated Power Supply Module, 1 Output, METAL, CASE C03, MODULE-11

文件: 总10页 (文件大小:212K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
NSR-Family  
Switching Regulators, PCB & Chassis  
Industrial Environment  
NSR: Negative Switching Regulators  
NSR-Family  
Case C03  
No input to output isolation  
Single output of –5 to –36 V DC/50...288 W  
Input voltage up to –80 V DC  
High efficiency up to 94%  
Wide input voltage range  
Low input-to-ouptut differential voltage  
Very good dynamic properties  
Input undervoltage cut-out  
Parallel configurations possible  
Continuous no-load and short-circuit proof  
No derating  
Safety according to IEC 950  
C
Table of Contents  
Page  
Type Survey .............................................................. 4 - 74  
Description ................................................................ 4 - 74  
Safety and Installation Instructions ........................... 4 - 75  
Immunity to Environmental Conditions...................... 4 - 76  
Electromagnetic Compatibility EMC.......................... 4 - 77  
Electrical Input and Output Data ............................... 4 - 78  
Characteristics and Definitions.................................. 4 - 80  
Description of Options............................................... 4 - 81  
Mechanical Data ....................................................... 4 - 83  
Type Key and Product Marking ................................. 4 - 83  
Type Survey  
Table 1: Type survey  
Nominal  
output  
voltage  
Uo nom  
Nominal  
output  
current  
Io nom  
Input  
voltage  
range  
Nominal  
input  
voltage  
Ui nom  
Efficiency  
Type  
designation  
Options  
1
Ui  
η
–5 V  
–5 V  
12 A  
10 A  
8 A  
–7...–40 V  
–8...–80 V  
–20 V  
–40 V  
81%  
70%  
89%  
89%  
91%  
94%  
NSR 512-7  
NSR 510-7  
NSR 128-7  
NSR 158-7  
NSR 248-7  
NSR 368-7  
-9, L, i, P, R, C  
–12 V  
–15 V  
–24 V  
–36 V  
–15...–80 V  
–19...–80 V  
–29...–80 V  
–42...–80 V  
–50 V  
–60 V  
-9, L, i, P, R  
1 See also data Uio min. (Minimum differential voltage Ui Uo)  
Description  
The NSR family of negative switching regulators is desig-  
ned as power supply modules for electronic systems. Their  
major advantages include a high level of efficiency that re-  
mains virtually constant over the entire input range, high  
reliability, low ripple and excellent dynamic response.  
The modules are specially designed for secondary  
switched and battery driven applications with positive sys-  
tem ground.  
External input circuitry  
An external capacitor (see "Application Notes") is required  
in rectifier mode and in DC operation mode only, if the sum  
of the lengths of the two input lines between source and in-  
put is greater than approx. 5 m. For long connection lines  
the use of option L is recommended in order to reduce su-  
perimposed interference voltages or currents and to pre-  
vent oscillation.  
Case C03: Aluminium, black finish and self cooling.  
4 - 74  
Edition 2/96 - © Melcher AG  
MELCHER  
The Power Partners.  
Industrial Environment  
Switching Regulators, PCB & Chassis  
NSR-Family  
Go+  
Gi+  
Control circuit  
–Ui  
Ce  
–Uo  
C (opt.)  
Input  
Filter  
L (opt.)  
Io  
Ii  
Vi–  
Vo–  
i (option)  
R (option)  
Fig. 1  
Block Diagram  
P (option)  
Safety and Installation Instructions  
Safety  
If the output circuit of a switching regulator is operator-ac-  
cessible according to the IEC 950 related safety standards,  
it shall be an SELV circuit (Safety Extra Low Voltage circuit,  
i.e. a circuit, separated from mains by at least basic insula-  
tion, that is so designed and protected that under normal  
and single fault conditions, the voltage between any two  
conductors and between any conductor and earth does not  
exceed 60 V DC).  
installer or user to assure the compliance with the relevant  
and applicable safety standards.  
If the following table is observed, the output of any switch-  
ing regulator is considered to be an SELV circuit up to a  
nominal output voltage of 36 V.  
Note: Check for hazardous voltages before altering  
any connections. Do not open the module. The input  
and the output circuitry are not separated, i.e. the posi-  
tive path is internally interconnected!  
In the following section an interpretation is provided of the  
IEC 950 safety standard with respect to the safety status of  
the output circuit. However, it is the sole responsibility of the  
Table 2: Insulation concept for SELV circuits  
Nominal Minimum required grade Maximum Minimum required  
Measures to achieve the  
specified safety status  
of the output circuit  
Resulting safety  
status of the  
switching  
mains  
of isolation, to be  
output  
safety status of the  
supply  
provided by the AC-DC  
voltage  
front end output circuit  
voltage front end, including mains from the  
regulator output  
circuit  
(AC)  
supplied battery charger front end  
None  
Battery supply completely  
separated from mains  
60 V  
80 V  
SELV battery circuit  
None  
SELV circuit  
SELV circuit  
Hazardous voltage battery Input fuse 1 and unearthed,  
circuit 2 non operator-accessible case 2  
Hazardous voltage battery Input fuse 1 and earthed output Earthed SELV  
circuit  
circuit 3 and earthed 3 or non  
operator-accessible case  
circuit  
250 V  
Basic  
60 V  
80 V  
Earthed SELV circuit  
ELV circuit  
Earthed input circuit 3  
SELV circuit  
Input fuse 1 and  
earthed output circuit 3  
Earthed SELV  
circuit  
Hazardous voltage  
secondary circuit  
Input fuse 1 and earthed output Earthed SELV  
circuit 3 and earthed 3 or non  
operator-accessible case  
circuit  
Double or reinforced  
60 V  
80 V  
SELV circuit  
None  
SELV circuit  
Double or reinforced insu- Input fuse 1 and unearthed and SELV circuit  
lated unearthed hazardous non operator-accessible case 2  
voltage secondary circuit 2  
1 The installer shall provide an approved fuse (slow blow type with lowest rating suitable for the application, max. 12.5 A) in the positive  
or negative input conductor directly at the input of the switching regulator. For UL's purpose, the fuse needs to be UL-listed. If option  
C is fitted, a suitable fuse is built-in.  
2 Has to be insulated from earth by double or reinforced insulation according to the relevant safety standard, based on the maximum in-  
put voltage of the switching regulator.  
3 The earth connection has to be provided by the installer according to the relevant safety standards, e.g. IEC 950.  
Edition 2/96 - © Melcher AG  
4 - 75  
MELCHER  
The Power Partners.  
NSR-Family  
Switching Regulators, PCB & Chassis  
Industrial Environment  
Standards and Approvals  
Cleaning Agents  
All Melcher power supplies are subject to manufacturing  
surveillance in accordance with ISO 9001 standards.  
In order to avoid possible damage, any penetration of  
cleaning fluids is to be prevented, since the power supplies  
are not hermetically sealed.  
All units are UL recognized as per UL 1950, UL 1012 and  
CAN/CSA C22.2 No. 234-M90.  
Protection Degree  
The protection degree is defined by IP 40. With option P  
this reduces to IP 20.  
Immunity to Environmental Conditions  
Table 3: Mechanical stress  
Test Method  
Standard  
Test Conditions  
Status  
Ca  
Ea  
Eb  
Fc  
Damp heat  
steady state  
DIN 40046 part  
IEC 68-2-3  
MIL-STD-810D section 507.2 Duration:  
Temperature:  
Relative humidity:  
40 ±2 °C  
%
56 days  
Unit not  
operating  
93 +2/-3  
Shock  
(half-sinusoidal)  
DIN 40046 part 7  
IEC 68-2-27  
MIL-STD-810D section 516.3 Number of bumps:  
Acceleration amplitude:  
Bump duration:  
100 gn = 981 m/s2  
6 ms  
18 (3 each direction)  
Unit  
operating  
Continuous shock DIN 40046 part 26  
(half-sinusoidal)  
Acceleration amplitude:  
Bump duration:  
40 gn = 392 m/s2  
6 ms  
6000 (1000 each direction)  
Unit  
operating  
IEC 68-2-29  
MIL-STD-810D section 516.3 Number of bumps:  
Vibration  
(sinusoidal)  
DIN 40046 part 8  
IEC 68-2-6  
MIL-STD-810D section 514.3 Acceleration amplitude:  
Test duration:  
Frequency (1 Oct/min):  
Max. vibration amplitude:  
10...2000 Hz  
Unit  
operating  
0.35 mm (10...60 Hz)  
5 gn = 49 m/s2 (60...2000 Hz)  
7.5 h (2.5 h each axis)  
Fda Random vibration DIN 40046 part 23  
Acceleration spectral density: 0.05 g2/Hz  
Unit not  
wide band  
reproducibility high  
IEC 68-2-35  
Frequency band:  
Acceleration magnitude:  
Test duration:  
20...500 Hz  
4.9 grms  
3 h (1 h each axis)  
operating  
Kb  
Salt mist  
cyclic  
(sodium chloride  
NaCl solution)  
DIN 40046 part 105  
IEC 68-2-52  
Concentration:  
Duration:  
Storage:  
Storage duration:  
Number of cycles:  
5% (30°C)  
Unit not  
operating  
2 h per cycle  
40°C, 93% rel. humidity  
22 h per cycle  
3
Table 4: Temperature specifications, valid for air pressure of 800...1200 hPa (800...1200 mbar)  
Temperature  
Standard -7  
Option -9  
Characteristics  
Conditions  
min  
max  
71  
min  
–40  
–40  
–55  
max  
71  
Unit  
TA  
TC  
TS  
Ambient temperature 1  
Ui min...Ui max  
Io = 0...Io nom  
–25  
–25  
–40  
°C  
Case temperature  
Storage temperature 1  
95  
95  
Not operational  
100  
100  
1
MIL-STD-810D section 501.2 and 502.2  
Table 5: MTBF and device hours  
MTBF  
Ground Fixed  
Ground Mobile  
Device Hours 1  
MTBF acc. to MIL-HDBK-217D  
TC = 40°C  
TC = 70°C  
TC = 40°C  
36'000 h  
TC = 70°C  
17'000 h  
130'000 h  
58'000 h  
1'050'000 h  
1
Statistical values , based on an average of 4300 working hours per year and in general field use  
4 - 76  
Edition 2/96 - © Melcher AG  
MELCHER  
The Power Partners.  
Industrial Environment  
Switching Regulators, PCB & Chassis  
NSR-Family  
Electromagnetic Compatibility EMC  
Immunity  
General condition: Case not earthed  
Table 6: Immunity type tests  
Phenomenon  
Standard  
Class  
Level  
Coupling  
mode4  
Value  
applied  
Waveform  
Source  
Imped.  
Test  
procedure  
In Per-  
oper. form.  
Impulse voltage IEC 255-4  
III  
III  
3
i/o, i/c, o/c  
+i/–i  
5000 Vp  
1.2/50 µs  
500 Ω  
200 Ω  
330 Ω  
3 pos. and 3 neg.  
impulses per  
coupling mode  
no  
yes  
yes  
-
App. E4 5  
(1976)  
1
High frequency IEC 255-4  
i/o, i/c, o/c  
+i/–i  
2500 Vp  
1000 Vp  
400 damped  
1 MHz waves/s  
2 s per  
coupling mode  
disturbance  
App. E5 5  
(1976)  
1
6
Electrostatic  
discharge  
IEC 801-2  
(1991-04)  
contact discharge  
to case  
6000 Vp  
1/50 ns  
10 positive and  
10 negative  
discharges  
1
Electric field  
IEC 801-3  
(1984)  
2
2
antenna in  
1m distance  
3 V/m sine wave mod-  
ulated w. 1 kHz  
26…1000 MHz  
yes  
yes  
2
6
Fast transient/  
burst  
IEC 801-4  
(1988)  
i/c  
1000 Vp bursts of 5/50 ns 50 Ω  
5 kHz rep. rate  
1 min positive  
1 min negative  
bursts per  
transients with  
15 ms burst  
coupling mode  
duration and a  
300 ms period  
2
6
Transient  
IEC 801-5  
(Draft 1993-01)  
II  
2
i/c  
1000 Vp  
500 Vp  
1.2/50 µs  
12 Ω  
2 Ω  
5 pos. and 5 neg.  
impulses per  
coupling mode  
yes  
+i/–i  
7
1
Immunity to  
conducted  
IEC 801-6  
i, o, signal wires  
3 Vrms  
80% amplitude  
modulated  
50 Ω  
AM 0.15...80 MHz yes  
disturbancies  
with 1 kHz  
1 Normal operation, no deviation from specifications  
2 Normal operation, temporary deviation from specs possible  
3 With option C: manual reset  
4 i = input, o = output, c = case  
5 In correspondance with DIN 57435 part 303 and VDE 0435 part 303 (1984-09)  
6 Option L neccessary  
7 Open circuit  
Emission  
For emission levels refer to "Electrical Input and Output  
Data".  
Edition 2/96 - © Melcher AG  
4 - 77  
MELCHER  
The Power Partners.  
NSR-Family  
Switching Regulators, PCB & Chassis  
Industrial Environment  
Electrical Input and Output Data  
General Conditions  
TA = 25°C, unless TC is specified.  
– With option P or R, output voltage Uo = Uo nom at Io nom  
Table 7a: Input and output data  
Characteristics  
Conditions  
NSR 512  
NSR 510  
NSR 128  
Unit  
min  
typ  
max  
–5.03  
15.6  
min  
–4.97  
10.0  
typ  
max  
–5.03  
13.0  
min  
typ  
max  
Output  
Uo  
Output voltage  
Ui nom, Io nom  
–4.97  
12.0  
–11.92  
8.0  
–12.07  
V
A
Io nom Output current  
Ui min...Ui max  
TC min...TC max  
12.0  
10.0  
8.0  
IoL  
Output current  
10.4  
150  
85  
limitation response  
uo  
Ripple at output  
(BW = 20 MHz)  
Ui nom  
Io nom  
35  
60  
50  
85 1  
35  
60  
50  
85 1  
80  
50  
mVpp  
mV  
Uo U Static control deviation Ui min...Ui max  
30  
45  
55 1  
30  
45  
25  
versus input voltage Ui Io nom  
Uo I Static control deviation Ui nom  
20  
25  
20  
28  
35  
55 1  
versus output current Io Io = 0…Io nom  
uo d  
tr  
Dynamic control  
deviation 2  
Ui nom  
o nom 1/  
Ionom  
135  
40  
130  
50  
130  
60  
I
3
Dynamic load transient  
time recovery 2  
µs  
αuo  
Temperature coefficient Ui min...Ui max  
±1  
±1  
±2  
mV/K  
%/K  
Uo/TC  
TC min...TC max  
Io = 0...Io nom  
±0.02  
±0.02  
±0.02  
Input  
Ui  
Input voltage  
Io = 0...Io nom  
TC min...TC max  
–7  
–40  
–8  
–80  
40  
–15  
–80  
V DC  
V
Uio min Minimum differential  
–2  
–3  
–3  
3
voltage Ui - Uo  
Ui o  
Ii 0  
Undervoltage cut-out  
–6.3  
–7.3  
–7.3  
No load  
input current  
Io = 0  
Ui min...Ui max  
45  
35  
mA  
A
Ii m  
Peak value of  
inrush current 4  
Ui nom  
150  
250  
250  
ti s  
ti r  
Rise time 4  
5
5
5
µs  
Tail half value time 4  
40  
40  
40  
Ii m  
Peak value of  
inrush current 4  
Ui nom  
with option L  
250  
350  
350  
A
ti s  
Rise time 4  
25  
25  
25  
µs  
ti r  
Tail half value time 4  
125  
125  
125  
ui rfi  
RFI level at input,  
0.01...30 MHz  
VDE 0871 (6.78)  
Uinom, Io nom  
A
A
A
dB  
(µV)  
Efficiency  
η
Efficiency  
Ui nom, Io nom  
81  
76  
88  
%
Isolation  
Uis  
Isolation test voltage  
electronics to case  
Inputs/outputs  
interconnected  
500  
500  
500  
V DC  
1
2
3
Lower row represents option -9 data only  
See “Dynamic Characteristics”  
The minimum differential voltage Uio min between input and output increases linearly from 0 to 1 V at TA = 46°C and 71°C  
(TC = 70°C and 95°C)  
Definitions according to VDE 0433, part 3  
4
4 - 78  
Edition 2/96 - © Melcher AG  
MELCHER  
The Power Partners.  
Industrial Environment  
Switching Regulators, PCB & Chassis  
NSR-Family  
Table 7b: Input and output data  
Characteristics  
Conditions  
NSR 158  
NSR 248  
NSR 368  
Unit  
min  
typ  
max  
min  
typ  
max  
min  
–35.78  
8.0  
typ  
max  
Output  
Uo  
Output voltage  
Ui nom, Io nom  
–14.91  
8.0  
–15.09  
–23.85  
8.0  
–24.14  
–36.22  
V
A
Io nom Output current  
Ui min...Ui max  
TC min...TC max  
8.0  
8.0  
8.0  
IoL  
Output current  
10.4  
150  
105  
10.4  
250  
220  
160  
10.4  
300  
limitation response  
uo  
Ripple at output  
(BW = 20 MHz)  
Ui nom  
Io nom  
80  
70  
100  
150  
120  
150  
80  
150  
200  
125  
225  
100  
mVpp  
mV  
Uo U Static control deviation Ui min...Ui max  
270  
370 1  
versus input voltage Ui Io nom  
Uo I Static control deviation Ui nom  
33  
45  
651  
160  
320 1  
versus output current Io Io = 0…Io nom  
uo d  
tr  
Dynamic control  
deviation 2  
Ui nom  
o nom 1/  
Io nom  
130  
60  
I
3
Dynamic load transient  
time recovery 2  
µs  
αuo  
Temperature coefficient Ui min...Ui max  
±3  
±5  
±8  
mV/K  
%/K  
Uo/TC  
TC min...TC max  
Io = 0...Io nom  
±0.02  
±0.02  
±0.02  
Input  
Ui  
Input voltage  
Io = 0...Io nom  
TC min...TC max  
–19  
–80  
–29  
–80  
35  
–42  
–80  
V DC  
V
Uio min Minimum differential  
–4  
–5  
–6  
3
voltage Ui - Uo  
Ui o  
Ii 0  
Undervoltage cut-out  
–7.3  
–12  
–19  
No load  
input current  
Io = 0  
Ui min...Ui max  
35  
40  
mA  
A
Ii m  
Peak value of  
inrush current 4  
Ui nom  
250  
250  
250  
ti s  
ti r  
Rise time 4  
5
5
5
µs  
Tail half value time 4  
40  
40  
40  
Ii m  
Peak value of  
inrush current 4  
Ui nom  
with option L  
350  
350  
350  
A
ti s  
Rise time 4  
25  
25  
25  
µs  
ti r  
Tail half value time 4  
125  
125  
125  
ui rfi  
RFI level at input,  
0.01...30 MHz  
VDE 0871 (6.78)  
Uinom, Io nom  
A
A
A
dB  
(µV)  
Efficiency  
η
Efficiency  
Ui nom, Io nom  
89  
91  
94  
%
Isolation  
Uis  
Isolation test voltage  
electronics to case  
Inputs/outputs  
interconnected  
500  
500  
500  
V DC  
1 Lower row represents option -9 data only  
2 See “Dynamic Characteristics”  
3 The minimum differential voltage Uio min between input and output increases linearly from 0 to 1 V at TA = 46°C and 71°C  
(TC = 70°C and 95°C)  
4 Definitions according to VDE 0433, part 3  
Edition 2/96 - © Melcher AG  
4 - 79  
MELCHER  
The Power Partners.  
NSR-Family  
Switching Regulators, PCB & Chassis  
Industrial Environment  
Characteristics and Definitions  
Parallel and Series Connection  
Output Protection  
A voltage suppressor diode protects the output against an  
internally generated overvoltage, which could occur due to  
a failure of the control circuit, which in worst case condi-  
tions fails into a short circuit. The suppressor diode is not  
designed to withstand externally applied overvoltages. The  
user should ensure that systems with Melcher power sup-  
plies, in the event of a failure, do not result in an unsafe  
condition (fail-safe).  
Outputs of equal nominal voltages can be parallel-con-  
nected. However, the use of a single unit with higher output  
power, because of its power dissipation, is always a better  
solution.  
In parallel-connected operation, one or several outputs may  
operate continuously at their current limit knee-point which  
will cause an increase of the case temperature. Conse-  
quently, the max. ambient temperature value should be re-  
duced by 10 K.  
Dynamic Characteristics  
Outputs can be series-connected with any other module. In  
series-connection the maximum output current is limited by  
the lowest current limitation. Galvanically separated source  
voltages are needed for each module!  
Uo  
uod  
Uo I  
Uo I  
uod  
Short circuit behaviour  
tr  
tr  
A constant current limitation circuit holds the output current  
almost constant whenever an overload or a short circuit is  
applied to the regulator's output. It acts self-protecting and  
recovers - in contrary to the fold back method - automati-  
cally after removal of the overload or short circuit condition.  
t
I /I  
o
o nom  
3/3  
2/3  
1/3  
0
Uo/Uo nom  
t
I
10 µs  
10 µs  
1.2  
1.0  
Fig. 2  
0.8  
Behaviour and characteristics under varying load condi-  
Io L  
tions.  
0.6  
0.4  
0.2  
Temperature  
When a converter is located in free, quasi-stationary air at a  
temperature TA = 71°C and is operated at its nominal output  
power, the case temperature TC will be about 95°C after the  
warm-up phase measured at the measuring point of case  
temperature TC (see "Mechanical Data").  
Io/Io nom  
0
0.2  
0.4  
0.6  
0.8  
1.0  
1.2  
1.4  
Fig. 4  
Overload, short-circuit behaviour Uo versus Io  
Under practical operating conditions, the ambient tempera-  
ture TA may exceed 71°C, provided additional measures  
are taken to ensure that the case temperature TC does not  
exceed its maximum value of 95°C ( heat sink, fan, etc.).  
Example: Sufficient forced cooling allows TA max = 85°C. A  
simple check of the case temperature TC (TC 95°C) at full  
load ensures correct operation of the system  
Po [%]  
110  
100  
Po max (forced cooling)  
Po max  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
(convection cooling)  
TC max  
TA [°C]  
50  
60  
70  
80  
90  
100  
–40  
Fig. 3  
Output power derating versus ambient temperature  
4 - 80  
Edition 2/96 - © Melcher AG  
MELCHER  
The Power Partners.  
Industrial Environment  
Switching Regulators, PCB & Chassis  
NSR-Family  
Description of Options  
Option i Inhibit  
Go+  
Gi+  
Note: With open i-input, output is enabled (Uo = on).  
Uinh  
The inhibit input allows the switching regulators to be disa-  
bled via a control signal. In systems with several units, this  
feature can be used, for example, to control the activation  
sequence of the regulators by a logic signal (TTL, C-MOS,  
etc.).  
Iinh  
i
Vi–  
Vo–  
An output voltage overshoot will not occur when the units  
are switched on or off.  
Fig. 5  
Definition of Iinh and Uinh  
Iinh [mA]  
t
0
2
1
0
10%  
100%  
tr  
tf  
-1  
-2  
Uo off  
Uo on  
Uo/Uo nom  
0
t
-3  
-4  
-5  
U
U
Uinh [V]  
Uinh  
-20  
-50  
-30  
-10  
0
-40  
10 20 30 40 50  
Fig. 6  
Fig. 7  
Inhibit current Iinh versus inhibit voltage Uinh  
Output response as a function of inhibit signal  
Table 8: Inhibit characteristics  
Characteristics  
Conditions  
min  
–0.8  
–50  
typ  
max  
+50  
Unit  
Uinh  
Inhibit input voltage to keep Uo = on  
Ui min...Ui max  
TC min...TC max  
V DC  
regulator output voltage...  
Uo = off  
–2.4  
tr  
Switch-on time after inhibit command  
Switch-off time after inhibit command  
Input current when inhibited  
Ui = Ui nom  
RL = Uo nom /Io nom  
5
ms  
tf  
10  
10  
Ii off  
Io = 0, Ui = Ui nom  
mA  
Option R Output voltage adjustment  
Note: with an open R-pin, Uo = 1.08 Uo nom  
!
ferential voltage Ui o min between input and output voltages  
as specified in relevant tables must be maintained. Options  
R and P cannot be supported simultaneously.  
The output voltage Uo can be adjusted either with an exter-  
nal resistance Rex or an external reference voltage Uex.The  
adjustment range is 0.65...1.08 of Uo nom. The minimum dif-  
Uref  
Vo–  
Vo–  
Uref  
4020 Ω  
4020 Ω  
R
R
Uex  
Rex  
Go+  
Go+  
Fig. 8  
Fig. 9  
Voltage adjustment with Rex [|  
Voltage adjustment with Uex [V]  
U
Uo 1.08 • Uex ––o nom–  
Uref  
R
(Uref = –2.49 V ±4%)  
Uo 1.08 • Uo nom • –––––ex––––  
Rex + 4020  
U
R
ex 4020 • ––––––––o–––––––  
Caution: To prevent damage Uex should not exceed  
1.08 • Uo nom Uo  
Uref nor be positive!  
All formulae give approximate values only.  
Edition 2/96 - © Melcher AG  
4 - 81  
MELCHER  
The Power Partners.  
NSR-Family  
Switching Regulators, PCB & Chassis  
Industrial Environment  
Option -9 Extended Temperature Range  
The operational ambient temperature range is extended to  
TA = –40...71°C.  
Option L Input filter  
With option L, the maximum permissible additionally super-  
imposed ripple ui of the input voltage (rectifier mode) at a  
specified input frequencyf i has the following values:  
Option L is recommended to reduce superimposed inter-  
ference voltages, and to prevent oscillations, if input lines  
exceed approx. 5 m in total length. The fundamental wave  
(approx. 120 kHz) of the reduced interference voltage be-  
tween Vi+ and Gi– has, with an input line inductance of  
Input voltage up to 80 V:  
ui max = 22 Vpp at 100 Hz or Vpp = 2200 Hz/fi • 1 V  
Input voltage up to 40 V:  
5 µH a maximum magnitude of 4 mVrms  
.
The input impedance of the switching regulator at 120 kHz  
is about 50 m. The harmonics are small in comparison  
with the fundamental wave. See also data: RFI.  
ui max = 12 Vpp at 100 Hz or Vpp = 1200 Hz/fi • 1 V  
Option P Potentiometer  
Option P excludes R option. The output voltage Uo can be  
adjusted with a screwdriver in the range from 0.92…1.08 of  
However, the minimum differential voltage Uio min between  
input and output voltages as specified in "Electrical Input  
and Output Data" should be maintained.  
the nominal output voltage Uo nom  
.
Option C Thyristor Crowbar  
Note: As a central overvoltage protection device, the crow-  
bar is usually connected to the external load via distributed  
inductance of the lines. For this reason, the overvoltage at  
the load can temporarily exceed the trigger voltage Uo c. De-  
pending on the application, further decentralized over-  
voltage protection elements may have to be used addition-  
ally.  
This option is recommended to protect the load against  
power supply malfunction, but it is not designed to sink ex-  
ternal currents.  
A fixed-value monitoring circuit checks the output voltage  
Uo. When the trigger voltage Uoc is reached, the thyristor  
crowbar triggers and disables the output. It may be deacti-  
vated by removal of the input voltage. In case of a switching  
transistor defect, an internal fuse prevents excessive cur-  
rent.  
Option C is not available for NSR 368 type.  
Table 9: Crowbar trigger levels  
Characteristics  
Conditions  
–5 V  
min  
–5.8  
–12 V  
min max  
–15 V  
min max  
–24 V  
Unit  
max  
–6.8  
1.5  
min  
–27  
max  
–31  
1.5  
Ui min...Ui max  
Io = 0...Io nom  
TC min...TC max  
Uo c Trigger voltage  
–13.5 –16  
1.5  
–16.5 –19  
1.5  
V
ts  
Delay time  
µs  
Option U Ambient Temp. Range acc. UL Recognition  
PCB material with a higher maximum temperature specifi-  
cation.  
Underwriters Laboratories (UL) have approved the NSR-  
family as recognized components up to an ambient tem-  
perature of TA max – 25 K, given by the upper temperature  
limit of the standard PCB material. If the full maximum am-  
bient temperature TA max is required with UL approval, op-  
tion U should be requested. It consists of an alternative  
The European approval boards have in contrast to UL ac-  
cepted the standard PCB material to be operated up to  
TA max = 71°C without any further precautions.  
4 - 82  
Edition 2/96 - © Melcher AG  
MELCHER  
The Power Partners.  
Industrial Environment  
Switching Regulators, PCB & Chassis  
NSR-Family  
Mechanical Data  
Dimensions in mm.Tolerances ±0.3 mm unless otherwise specified.  
European  
Projection  
LED-output  
voltage indicator  
Potentiometer  
(option P)  
Uo  
R
Gi+  
Go+  
Vo–  
Vi–  
U
G
i
o
151 ±1  
Distance between M4 mounting screws  
144  
5 ±0.5  
Measuring point  
of case temperature T  
C
11.3  
40  
18.5  
Fig. 10  
Case C03 (weight 440 g)  
12.5 ±1  
7.5  
10 7.5 10  
(14)  
7.5  
27.5  
7.5  
Type Key and Product Marking  
Type Key  
NSR 12 8 -7 L i R P C  
Negative switching regulator in case C03 .................. NSR  
Blank ..................................................................................  
Nominal output voltage in volt ............................... –5...–36  
Nominal output current in ampere............................. 8...12  
Ambient temperature range  
TA = –25...71°C ................................................... -7  
TA = –40...71°C ................................................... -9  
Input filter ......................................................................... L  
Inhibit input........................................................................ i  
External output voltage adjustment................................. R  
Potentiometer...................................................................P  
Thyristor-Crowbar ........................................................... C  
Example:NSR 128-7iP = A negative switching regulator with a –12 V, 8 A output, ambient temperature range of  
–25…71°C, inhibit input and potentiometer.  
Produkt Marking  
Main face: Family designation, applicable safety approval and recognition marks, warnings, Melcher patent nos. and com-  
pany logo.  
Cover:  
Specific type designation, input voltage range, nominal output voltage and current, pin allocation, identification  
of LED, potentiometers and degree of protection.  
Rear side: Label with batch no., serial no. and data code comprising production site, modification status of the main PCB  
and date of production.  
Edition 2/96 - © Melcher AG  
4 - 83  
MELCHER  
The Power Partners.  

相关型号:

NSR510-9LIR

DC-DC Regulated Power Supply Module, 1 Output, METAL, CASE C03, MODULE-11
BEL

NSR510-9LIRC

DC-DC Regulated Power Supply Module, 1 Output, METAL, CASE C03, MODULE-11
BEL

NSR512-79C

DC-DC Regulated Power Supply Module, 1 Output, Hybrid
BEL

NSR512-79I

DC-DC Regulated Power Supply Module, 1 Output, Hybrid
BEL

NSR512-79IPC

DC-DC Regulated Power Supply Module, 1 Output, Hybrid
BEL

NSR512-79IPR

DC-DC Regulated Power Supply Module, 1 Output, Hybrid
BEL

NSR512-79LC

DC-DC Regulated Power Supply Module, 1 Output, Hybrid
BEL

NSR512-79LI

DC-DC Regulated Power Supply Module, 1 Output, Hybrid
BEL

NSR512-79LIC

DC-DC Regulated Power Supply Module, 1 Output, Hybrid
BEL

NSR512-79LIP

DC-DC Regulated Power Supply Module, 1 Output, Hybrid
BEL

NSR512-79LIPC

DC-DC Regulated Power Supply Module, 1 Output, Hybrid
BEL

NSR512-79LIPR

DC-DC Regulated Power Supply Module, 1 Output, Hybrid
BEL