OBD DC-DC Series Data Sheet
Dual-Output, 25 Watts
Features
•
•
•
•
•
•
•
Industry-standard package
48 V input
Fixed-frequency design
100 °C case operation
Trim and enable pins
6-sided shielding
Description
1500 V isolation
OBD dual-output dc-dc converters provide up to 25 watts
of output power in an industry-standard package and
footprint. These units feature excellent efficiency, six-sided
shielding, and fixed switching frequency. With 100 °C case
operation, the OBS Series is well suited to telecom,
networking, and industrial applications. The OBD Series is
100% surface-mount construction and fully compatible with
production board washing processes.
Efficiency vs. Load (24V Input)
90
85
80
75
70
65
Technical Specifications
Input
Voltage Range
48 VDC Nominal
Reflected Ripple
Input Reverse Voltage Protection
EFF. OBD25YHH
34 - 75 VDC
25 mA
Shunt Diode
10
20
30
40
50
60
70
80
90
100
LOAD %
Output
Setpoint Accuracy
±±1
Line Regulation V Min. - V Max., I
Rated
0.21 V
in
in
Min. - I
out
Max., V Nom.
out
Load Regulation I
Minimum Output Current
0.51 V
out
Efficiency vs. Load (48V Input)
out
out
in
±0 1 I
Rated
out
100
90
80
70
60
50
40
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
251 I
41 V
out
out
500 µs
±±01
Voltage Trim Range
Short Circuit / Overcurrent Protection
Current Limit Threshold Range, 1 of I
OVP Trip Range
Hiccup
±±0 - ±401
Rated
out
±±5 - ±401 V
Nom.
Second Control Loop
EFF. OBD025ZJJ
EFF. OBD025ZGG
EFF. OBD025ZHH
out
OVP and UVP Type
General
Turn-On Time: 24 & 48V Input
Remote Shutdown
Remote Shutdown Reference
Switching Frequency
Isolation
±0 ms
Positive
Negative
400 kHz
10
20
30
40
50
60
70
80
90
100
LOAD %
V
in
Notes
Input - Output
±500 VDC
±050 VDC
500 VDC
0.031/°C
Input - Case (±2 V and 24 V units)
†
in
in
MTBF predictions may vary slightly from model to model.
Industrial temp range available.
Output - Case (48 V units)
in
††
Temperature Coefficient
Case Temperature
Specifications typically at 25 °C, normal line, and full load, unless
otherwise stated.
Operating Range (±2V Input Max. Temp +85°C)
Storage Range
-40 to +±00 °C
-40 to +±25 °C
5 g, ±0 - 55 Hz
Soldering Conditions: I/O pins, 260 °C, ten seconds; fully
compatible with commercial wave-soldering equipment.
Vibration, 3 Axes, 5 Min. Each
6
†
MTBF (Bellcore TR-NWT-000332)
±.9 x ±0 hrs
Safety
Weight (Approx.)
UL, cUL, TUV
±.4 oz
Units are water-washable and fully compatible with commercial
spray or immersion post wave-solder washing equipment.
JUN 04, 2004 revised to APR 05, 2006
Page 1 of 2
www.power-one.com
OBD DC-DC Series Data Sheet
Dual-Output, 25 Watts
Model Selection
INPUT VOLTAGE
INPUT VOLTAGE
RANGE (VOLTS)
MAXIMUM INPUT
CURRENT (AMPS)*
OUTPUT
VOLTAGE (VOLTS)
RATED OUTPUT
CURRENT (AMPS)
RIPPLE & NOISE
pk-pk (mV)
TYPICAL
EFFICIENCY**
MODEL
(VOLTS)
OBD025YHH
OBD025ZGG
OBD025ZHH
OBD025ZJJ
24
48
48
48
±8 - 36
34 - 75
34 - 75
34 - 75
±.7
±±2
±5
±±2
±±5
±±.0
±2.5
±±.0
±20
75
±20
±50
861
801
861
881
0.93
0.9±
0.9±
±0.85
NOTES:
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal V , rated output.
in
Model numbers highlighted in yellow or shaded are not recommended for new designs.
Mechanical Drawing
Tolerances
(Millimeters)
Thermal Impedance
Inches:
.XX ± 0.020
.XXX ± 0.010
.X ± 0.5
.XX ± 0.25
Natural Convection
±00 LFM
200 LFM
300 LFM
400 LFM
±0.3 °C/W
7.7 °C/W
6.3 °C/W
5.± °C/W
4.± °C/W
Pin
Function
1
2
3
4
5
6
7
8
+V
in
Pin:
± 0.002
-V
± 0.05
in
No Conn.
Enable
Note:
Case:
+ 0.04, - 0.00
Thermal impedance data is dependent
on many environmental factors. The
exact thermal performance should be
validated for specific application.
+ 1.0, - 0.0
+V
out
Common
(Tolerances as listed unless otherwise
specified.)
-V
out
Trim
NUCLEAR AND MEDICALAPPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
JUN 04, 2004 revised to APR 05, 2006
Page 2 of 2
www.power-one.com