OES033ZE-A8 [BEL]

DC-DC Regulated Power Supply Module, 1 Output, 40W, Hybrid;
OES033ZE-A8
型号: OES033ZE-A8
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

DC-DC Regulated Power Supply Module, 1 Output, 40W, Hybrid

文件: 总3页 (文件大小:167K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
OES DC/DC Series Data Sheet  
Features  
• Ultra-dense 40W converter  
• Industry-standard package  
• 100 °C baseplate operation  
• Open-frame packaging  
• 5, 3.3, 2.5, and 2.1V outputs  
• Remote enable pin  
• 1500V isolation  
• Input Pi filter  
Description  
OES DC/DC converters are ultra-dense, 40 watt, single output converters produced for the telecom and  
networking markets. Making use of open-frame packaging, planar magnetics, high efficiency topologies, and surface-  
mount design, the OES has superior thermal performance. The OES features 1500 VDC isolation and overvoltage  
protection, as well as input undervoltage lockout.  
Technical Specifications  
Input  
Voltage Range  
48 VDC Nominal  
Input Under Voltage Lockout  
Input Undervoltage Hysteresis  
36 - 72 VDC  
<34V  
1V Nominal  
Efficiency vs. Load (48V Input)  
Reflected Ripple  
50 mA pk-Pk  
95  
90  
85  
80  
75  
70  
65  
60  
55  
50  
45  
40  
Input Reverse Voltage Protection  
Shunt Diode  
Output  
Setpoint Accuracy  
3.3/5.0 V Line Regulation V Min. - V Max., I  
±1%  
Rated  
Rated  
0.2% V  
in  
in  
out  
out  
out  
OES021ZC-A  
2.5/2.1 V Line Regulation V Min. - V Max., I  
0.4% V  
in  
in  
out  
OES025ZD-A  
OES033ZE-A  
OES040ZG-A  
Load Regulation I  
Min. - I  
Max., V Nom.  
0.5% V  
out  
out  
in  
out  
Minimum Output Current  
10%, I  
Rated  
out  
Dynamic Regulation, Loadstep  
Pk Deviation  
25% I  
6% V  
out  
out  
1
2
3
4
5
6
7
8
9
10  
X10 = LOAD %  
Settling Time  
Voltage Trim Range  
Short Circuit / Overcurrent Protection  
500 m s  
±10%  
Shutdown / Hiccup  
General  
Current Limit Threshold Range, % of I  
Rated  
110 - 140%  
Turn-On Time  
Remote Shutdown  
Switching Frequency, 3.3V Output  
Switching Frequency, 5.0, 2.5, 2.1V Outputs  
Isolation  
10 ms  
Positive Logic  
400 kHz  
out  
OVP Trip Range  
120 - 140% V  
Nom.  
out  
300 kHz  
Remote Shutdown Reference  
V
Negative  
in  
Input - Output  
Input - Case  
Output - Case  
1500 VDC  
1050 VDC  
500 VDC  
Notes  
MTBF predictions may vary slightly from model to model.  
Temperature Coefficient  
Case Temperature  
Operating Range  
±0.03%/°C  
Specifications typically at 25°C, normal line, and full load, unless otherwise  
stated.  
-40 To +100°C  
-40 To +125°C  
105 To 115°C  
5 g, 10 - 55 Hz  
Storage Range  
Thermal Shutdown Range  
Vibration, 3 Axes, 5 Min Each  
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with  
commercial wave-soldering equipment.  
6
MTBF (Bellcore TR-NWT-000332)  
2.5 X 10 hrs  
Safety  
Weight (Approx.)  
UL, cUL, TUV  
1.4 oz  
Units are water-washable and fully compatible with commercial spray or  
immersion post wave-solder washing equipment.  
REV. OCT 03, 2003  
Page 1 of 3  
OES DC/DC Series Data Sheet  
Model Selection  
INPUT VOLTAGE  
INPUT VOLTAGE  
RANGE (VOLTS)  
MAXIMUM INPUT  
CURRENT (AMPS)*  
OUTPUT  
VOLTAGE (VOLTS)  
RATED OUTPUT  
CURRENT (AMPS)  
RIPPLE & NOISE  
pk-pk (mV)  
TYPICAL  
EFFICIENCY**  
MODEL  
(VOLTS)  
OES021ZC-A  
OES025ZD-A  
OES033ZE-A  
OES040ZG-A  
48  
48  
48  
48  
36-72  
36-72  
36-72  
36-72  
0.77  
0.87  
1.12  
1.31  
2.1  
2.5  
3.3  
5
10.00  
10.00  
10.00  
8.00  
50  
50  
75  
75  
84%  
81%  
85%  
89%  
NOTES: * Maximum input current at minimum input voltage, maximum rated output power.  
** At nominal V , rated output.  
in  
Mechanical Drawing  
Thermal Impedance  
Pin  
Function  
Tolerances  
Inches:  
.XX ± 0.020  
.XXX ± 0.010  
(Millimeters)  
.X ± 0.5  
.XX ± 0.25  
Natural Convection  
11.3 C/W  
8.9 C/W  
6.2 C/W  
4.4 C/W  
3.4 C/W  
1
2
+V  
in  
100 LFM  
200 LFM  
300 LFM  
400 LFM  
-V  
in  
3
4
5
No Conn.  
Enable  
Pin:  
± 0.002  
± 0.05  
+V  
out  
(Dimensions as listed unless otherwise specified.)  
6
7
-V  
out  
Note:  
Trim  
Thermal impedance data is dependent on  
many environmental factors. The exact  
thermal performance should be validated  
for specific application.  
REV. OCT 03, 2003  
Page 2 of 3  
OPTIONS  
This page is offered as a reference. Consult factory for actual availability of options. When ordering  
equipment options, use the following suffix information. Select preferred option(s) and add the suffix to the  
model number. Ordering option examples are located below the options table.  
OPTION  
Negative Logic  
SUFFIX  
APPLICABLE SERIES  
REMARKS  
N
HAS, HBD, HBS, HES, HLS, HLD, LES,  
QBS, QES, QLS, TES, TQD  
TTL "Low" Turns Module ON  
TTL "High" Turns Module OFF  
Lucent-Compatible Trim  
T
HAS, HBD, HBS, HES, HLS, QBS, QES,  
QLS  
Trim  
1
2
3
IAS, LES  
Enable  
IAD, IAS, LES, SMS  
IAS, LES  
Trim and Enable  
Pin Length and Heatsink Options  
0.110" (2.8mm) Pin Length  
Standard Pin Length is 0.180" (4.6mm)  
8
9
All Leaded Models  
All Leaded Models  
0.150" (3.8mm) Pin Length  
0.24" (6.1mm) Horizontal Heatsink  
1H  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
Includes Thermal Pad  
Includes Thermal Pad  
Includes Thermal Pad  
Includes Thermal Pad  
Includes Thermal Pad  
Includes Thermal Pad  
0.24" (6.1mm) Vertical Heatsink  
0.45" (11.4mm) Horizontal Heatsink  
0.45" (11.4mm) Vertical Heatsink  
0.95" (24.1mm) Horizontal Heatsink  
0.95" (24.1mm) Vertical Heatsink  
1V  
2H  
2V  
3H  
3V  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
Example Options:  
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95” vertical heatsink.  
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.  
QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110” pin length.  
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,  
equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president  
of Power-One, Inc.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the  
date manufactured. Specifications are subject to change without notice.  
REV. OCT 03, 2003  
Page 3 of 3  

相关型号:

OES033ZE-A82V

DC-DC Regulated Power Supply Module, 1 Output, 40W, Hybrid
BEL

OES033ZE-A9

DC-DC Regulated Power Supply Module, 1 Output, 40W, Hybrid
BEL

OES033ZE-A91V

DC-DC Regulated Power Supply Module, 1 Output, 40W, Hybrid
BEL

OES033ZE-A92H

DC-DC Regulated Power Supply Module, 1 Output, 40W, Hybrid
BEL

OES033ZE-A92V

DC-DC Regulated Power Supply Module, 1 Output, 40W, Hybrid
BEL

OES033ZE-A93H

暂无描述
BEL

OES033ZE-A93V

DC-DC Regulated Power Supply Module, 1 Output, 40W, Hybrid
BEL

OES040ZG

DC-DC Regulated Power Supply Module, 1 Output, 40W
BEL

OES040ZG-A

Ultra-Dense 40W converter
POWER-ONE

OES040ZG-A1V

DC-DC Regulated Power Supply Module, 1 Output, 40W, Hybrid
BEL

OES040ZG-A3H

DC-DC Regulated Power Supply Module, 1 Output, 40W, Hybrid
BEL

OES040ZG-A8

DC-DC Regulated Power Supply Module, 1 Output, 40W, Hybrid
BEL