PFC375-1048FM [BEL]

AC-DC Regulated Power Supply Module, 450W;
PFC375-1048FM
型号: PFC375-1048FM
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

AC-DC Regulated Power Supply Module, 450W

输出元件
文件: 总5页 (文件大小:144K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
PFC375 AC-DC Series Data Sheet  
Features  
RoHS lead-solder-exempt compliant  
Greater than 1 million hours demonstrated MTBF  
Power Factor Correction (PFC) meets EN61000-3-2  
Fully-regulated outputs  
Main output remote sense  
Current Share, Power Fail, and Power Good signals  
Overtemperature, overvoltage, and overcurrent protected  
Available with metric and SAE mountings  
Input transient & ESD compliance to  
EN61000-4-2/-3/-4/-5  
Fan output voltage and optional fan  
Description  
The PFC375 products of the PerFormanCe Power Series incorporate high performance midrange power, active Power  
Factor Correction (PFC), and high reliability to meet varied commercial and industrial requirements.  
Providing tightly-regulated DC power in a wide variety of single and multiple output configurations, the PFC375 is  
designed to provide full output power with only 300 Linear Feet per Minute (LFM) forced-air cooling (factory installed  
fan optional). Other features include remote sense, power fail, logic level inhibit, and DC power good. Main channel  
current sharing is provided for redundant applications. The PFC375 is available with SAE mountings or optional metric  
mountings.  
The PFC375 product line is approved to the latest international regulatory standards and displays the CE Mark.  
Single-Output Model Selection  
OUTPUT  
VOLTAGE  
ADJUSTMENT  
RANGE  
MAXIMUM OUTPUT  
CURRENT (NOTE 1)  
LINE  
REGULATION  
LOAD  
REGULATION  
RIPPLE & NOISE  
%p-p (NOTE 2)  
INITIAL SETTING  
ACCURACY  
MODEL  
PFC375-1012  
PFC375-1015  
PFC375-1024  
PFC375-1028  
PFC375-1048  
12V  
15V  
24V  
28V  
48V  
10.8V to 13.5V  
12.0V to 17.0V  
21.6V to 26.4V  
25.2V to 30.8V  
46.0V to 56.0V  
30A  
25A  
15A  
13.4A  
7.8A  
0.2%  
0.2%  
0.5%  
0.5%  
0.5%  
0.8%  
0.6%  
0.8%  
0.9%  
1.0%  
1%  
1%  
1%  
0.9%  
1%  
11.94V to 12.06V  
14.94V to 15.06V  
23.88V to 24.12V  
27.86V to 28.14V  
47.52V to 48.48V  
NOTES: 1) Output currents ratings are expressed with 300 LFM forced air.  
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.  
Model numbers highlighted in yellow or shaded are not recommended for new designs.  
MCD10156 Rev. 1.0, 20-Apr-10  
Page 1 of 5  
www.power-one.com  
PFC375 AC-DC Series Data Sheet  
Multiple-Output Model Selection - Isolated V3 and V4 Can Be Used as Positive Or Negative Output  
OUTPUT  
VOLTAGE  
ADJUSTMENT  
RANGE  
OUTPUT  
CURRENT (NOTE 1)  
PEAK OUTPUT  
CURRENT (NOTE 3)  
LINE  
REGULATION  
LOAD  
REGULATION  
RIPPLE & NOISE  
%p-p (NOTE 2)  
INITIAL SETTING  
ACCURACY  
MODEL  
+5V  
+12V  
12V  
5V  
4.5V to 5.5V  
11.3V to 12.6V  
11.3V to 12.6V  
Fixed  
3.5 - 40A  
10A  
6A  
3A  
3.5 - 40A  
10A  
6A  
3A  
3.5 - 40A  
10A  
6A  
3A  
3.5 - 40A  
10A  
4A  
4A  
3.5 - 40A  
10A  
3A  
3A  
1 - 10A  
10A  
4A  
4A  
1 - 10A  
10A  
4A  
4A  
40A  
16A  
6A  
0.4%  
0.9%  
0.9%  
2%  
0.8%  
0.9%  
0.9%  
2%  
1%  
1%  
1%  
2.4%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
1%  
4.98V to 5.02V  
11.9V to 12.1V  
11.9V to 12.1V  
4.9V to 5.1V  
PFC375-4000  
3A  
+5V  
+12V  
12V  
12V  
+5V  
+12V  
12V  
24V  
+5V  
+12V  
15V  
15V  
+5V  
+12V  
24V  
24V  
+24V  
+5V  
12V  
12V  
+24V  
+5V  
15V  
15V  
4.5V to 5.5V  
40A  
16A  
6A  
0.4%  
0.9%  
0.9%  
0.9%  
0.4%  
0.9%  
0.9%  
0.5%  
0.4%  
0.9%  
0.7%  
0.7%  
0.4%  
0.9%  
0.5%  
0.5%  
0.5%  
0.4%  
0.5%  
0.5%  
0.5%  
0.4%  
0.5%  
0.5%  
0.8%  
0.9%  
0.9%  
0.9%  
0.8%  
0.9%  
0.9%  
0.8%  
0.8%  
0.9%  
0.7%  
0.7%  
0.8%  
0.9%  
0.8%  
0.8%  
0.8%  
0.8%  
1%  
4.98V to 5.02V  
11.9V to 12.1V  
11.9V to 12.1V  
11.9V to 12.1V  
4.98V to 5.02V  
11.9V to 12.1V  
11.9V to 12.1V  
23.8V to 24.2V  
4.98V to 5.02V  
11.9V to 12.1V  
14.9V to 15.1V  
14.9V to 15.1V  
4.98V to 5.02V  
11.9V to 12.1V  
23.8V to 24.2V  
23.8V to 24.2V  
23.8V to 24.2V  
4.98V to 5.02V  
11.9V to 12.1V  
11.9V to 12.1V  
23.8V to 24.2V  
4.98V to 5.02V  
14.9V to 15.1V  
14.9V to 15.1V  
11.3V to 12.6V  
11.3V to 12.6V  
11.0V to 15.8V  
4.5V to 5.5V  
11.3V to 12.6V  
11.3V to 12.6V  
22.0V to 28.0V  
4.5V to 5.5V  
11.3V to 12.6V  
14.2V to 15.8V  
14.2V to 15.8V  
4.5V to 5.5V  
11.3V to 12.6V  
22.0V to 28.0V  
22.0V to 28.0V  
21.5V to 26.4V  
4.5V to 5.5V  
PFC375-4001  
(Note 4)  
3A  
40A  
16A  
6A  
PFC375-4002  
(Note 5)  
3A  
40A  
16A  
4A  
PFC375-4004  
4A  
40A  
16A  
3A  
PFC375-4005  
(Note 6)  
3A  
10A  
16A  
4A  
PFC375-4200  
PFC375-4201  
11.4V to 12.6V  
11.4V to 12.6V  
21.5V to 26.4V  
4.5V to 5.5V  
14.2V to 16.0V  
13.7V to 16.0V  
4A  
1%  
10A  
16A  
4A  
0.8%  
0.8%  
0.8%  
0.8%  
4A  
+5V  
+12V  
12V  
5V  
4.5V to 5.5V  
11.3V to 12.6V  
11.3V to 12.6V  
4.5V to 5.5V  
3.5 - 50A  
10A  
50A  
16A  
6A  
0.4%  
0.9%  
0.9%  
2%  
0.8%  
0.9%  
0.9%  
0.9%  
1%  
1%  
1%  
1%  
4.98V to 5.02V  
11.9V to 12.1V  
11.9V to 12.1V  
4.9V to 5.1V  
PFC375-4500  
6A  
3A  
3A  
NOTES: 1) Output currents ratings are expressed with 300 LFM forced air.  
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.  
3) Peak loads up to 450 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 450 Watts.  
4) V4 can be adjusted to 16V with a minimum load of 5A on V1.  
5) For operation of V4 greater than 24V, consult factory.  
6) V3 and V4 may be series connected to obtain 48V.  
Model numbers highlighted in yellow or shaded are not recommended for new designs.  
MCD10156 Rev. 1.0, 20-Apr-10  
Page 2 of 5  
www.power-one.com  
PFC375 AC-DC Series Data Sheet  
Input Specifications  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
85  
47  
85  
20  
NOM  
MAX  
264  
63  
UNITS  
VAC  
Hz  
VAC  
ms  
Input Voltage - AC  
Input Frequency  
Brown Out Protection  
Hold-Up Time  
Continuous input range.  
AC Input.  
Lowest AC input voltage that regulation is maintained with full rated loads.  
Over full AC input voltage range at full rated load.  
85 VAC at full rated load.  
Input Current  
6
ARMS  
Input Protection  
Inrush Surge Current  
Non-user serviceable internally located AC input line fuse, F10A, 250V.  
Internally limited by thermistor, one cycle, 25°C.  
110 VAC  
220 VAC  
35  
65  
APK  
Power Factor  
Operating Frequency  
Per EN61000-3-2.  
Switching frequency of main transformer.  
0.98  
W/VA  
kHz  
100  
Output Specifications  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
68  
0
NOM  
MAX  
UNITS  
Efficiency  
Minimum Loads  
Full rated load, 110 VAC. Varies with distribution of loads among outputs.  
Single output models.  
%
Multiple output models, 5V main output only.  
Multiple output models, 24V main output only.  
Full load, 20MHz bandwidth.  
300 LFM forced air cooling required for operation. See optional fan.  
Continuous power, multiple output models.  
Peak power, all models.  
Output voltage overshoot/undershoot at turn-on.  
Varies by output. Total regulation includes: line changes from 85-132 VAC or  
170-264 VAC, changes in load starting at 20% load and changing to 100% load.  
3.5  
1
Amps  
Ripple and Noise  
Output Power  
See Model Selection Charts  
375  
450  
0
Watts  
V
Overshoot / Undershoot  
Regulation  
See Model Selection Charts  
Transient Response  
Recovery time, to within 1% of initial set point due to a 50-100% load change,  
3% max. deviation. (Main output only on multi-output units).  
1
ms  
Turn-On Delay  
Turn-On Rise Time  
Time required for initial output voltage stabilization.  
Time required for output voltage to rise from 10% to 90%.  
1
Sec  
ms  
10  
MCD10156 Rev. 1.0, 20-Apr-10  
Page 3 of 5  
www.power-one.com  
PFC375 AC-DC Series Data Sheet  
Interface Signals and Internal Protection  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Overvoltage Protection  
Provided on single output units and the main output only of multiple output units.  
PFC375-30XX, PFC375-40XX, PFC375-45XX  
PFC375-1012  
6.0  
6.4  
13.5  
17.0  
27.0  
30.8  
60.0  
27.0  
15.5  
19.5  
30.7  
35.0  
70.0  
30.7  
PFC375-1015  
PFC375-1024  
PFC375-1028  
PFC375-1048  
V
PFC375-42XX  
Overload Protection  
Overtemperature Protection  
Remote Sense  
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.  
System shutdown due to excessive internal temperature, automatic reset.  
Total voltage compensation for cable losses with respect to the main output.  
Accuracy of shared current with up to 6 parallel units.  
250  
10  
mV  
%
Current Share  
Inhibit  
TTL compatible logic signal will inhibit outputs by the application of a logic low signal.  
An open circuit or external TTL high signal allows normal operation.  
Input Power  
Fail Warning  
Power Good  
Fan Voltage  
TTL compatible logic signal. Time before regulation dropout due to  
loss of input power at 110 VAC.  
TTL compatible signal. Signal is low if main output is greater or less than 10% of nominal.  
Provides 170 mA current to user-supplied fan, if fan option is not selected.  
5
ms  
V
12  
Safety, Regulatory, and EMI Specifications  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Agency Approvals  
UL1950.  
CSA 22.2 NO. 234/950.  
EN60950 (TÜV).  
Input to output.  
FCC CFR title 47 Part 15 Sub-Part B - Conducted.  
EN55022 / CISPR 22 Conducted.  
Approved  
Dielectric Withstand Voltage  
Electromagnetic Interference  
2600  
B
B
VDC  
Class  
ESD Susceptibility  
Radiated Susceptibility  
EFT/Burst  
Per EN61000-4-2, level 4.  
Per EN61000-4-3, level 3.  
Per EN61000-4-4, level 4.  
Per EN61000-4-5 class 3.  
8
10  
4
1
2
kV  
V/M  
kV  
Input Transient Protection  
Line to Line  
Line to Ground  
kV  
Insulation Resistance  
Leakage Current  
Input to output.  
Per EN60950, 264 VAC.  
10  
M  
mA  
2.0  
Environmental Specifications  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Altitude  
Operating.  
Non-Operating.  
10k  
40k  
ASL Ft.  
ASL Ft.  
Operating Temperature  
At 100% load  
At 50% load  
0
0
50  
70  
°C  
°C  
Derate linearly above 50°C by 2.5% per °C.  
Storage Temperature  
Forced Air Cooling  
-55  
85  
°C  
Forced air cooling of 300 LFM is required if the internal fan option is not specified.  
Cooling air velocity is measured 1/4" above, at the middle of the chassis.  
Airflow direction is from the input section to the output section.  
Temperature Coefficient  
Relative Humidity  
Shock  
0°C to 70°C (after 15-minute warmup).  
Non-Condensing.  
Operating: 10 3mS, 3 axis, Halfsine.  
0.02  
0.05  
95  
20  
40  
%/°C  
%RH  
5
G
Non-operating: 10 3mS, 3 axis, Halfsine.  
Vibration  
Operating:  
5-32 Hz  
32-2000 Hz Sinusoidal  
0.02  
1
in (DA)  
GRMS  
Non-operating:  
6.15  
GRMS  
MCD10156 Rev. 1.0, 20-Apr-10  
Page 4 of 5  
www.power-one.com  
PFC375 AC-DC Series Data Sheet  
Options  
DESCRIPTION  
NOTES  
SIZE IMPACT  
Fan  
Add “F” as a suffix to the model number to order integral fan.  
(provides required 300 LFM of forced air cooling).  
10.50" x 5.00" x 2.50"  
(266.7mm x 127.0mm x 63.5mm)  
Metric Mounting  
Add “M” as a suffix to the model number to order chassis with  
M4 x 0.7 mounting inserts.  
9.00" x 5.00" x 2.50"  
(228.6mm x 127.0mm x 63.5mm)  
Overall Size: 9.00" x 5.00" x 2.50" (228.6mm x 127.0mm x 63.5mm)  
Overall Length With Fan: 10.50" (266.7mm)  
Weight: 4.3 lb (1.95 kg)  
Input and Output Connections:  
6-32 Screw Terminal on 0.375" (9.5mm) Centers  
Bus Bar Main Output, E1 & E2, 10-32 Screw Terminal  
Chassis: 0.090" (2.3mm) Aluminum Alloy, With Clear  
Finish  
TERMINAL BLOCKS have 6-32 (PHILSLOT) screw connections on 0.375"  
(9.53mm) centers; open space clearance for connections is 0.31" (7.87mm).  
Rated current per connection is 20 Amps maximum. UL94V-0 thermoplastic  
rating. Recommended torque is 6-8 inch lbs.  
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical  
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of  
the respective divisional president of Power-One, Inc.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the  
date manufactured. Specifications are subject to change without notice.  
MCD10156 Rev. 1.0, 20-Apr-10  
Page 5 of 5  
www.power-one.com  

相关型号:

PFC375-3001F

PSU 375W 3 O/P
ETC

PFC375-4000

PerFormanCe POWER
POWER-ONE

PFC375-4000F

PSU 350 WATT 4 O/P
ETC

PFC375-4000G

Greater than 1 million hours demonstrated MTBF
BEL

PFC375-4001

PerFormanCe POWER
POWER-ONE

PFC375-4001F

PSU 350 W 4 O/P
ETC

PFC375-4001G

Greater than 1 million hours demonstrated MTBF
BEL

PFC375-4002

PerFormanCe POWER
POWER-ONE

PFC375-4002F

PSU 350 W 4 O/P
ETC

PFC375-4002G

Greater than 1 million hours demonstrated MTBF
BEL

PFC375-4004

PerFormanCe POWER
POWER-ONE

PFC375-4004G

Greater than 1 million hours demonstrated MTBF
BEL