PFC500-1028M [BEL]
AC-DC Regulated Power Supply Module, 500W;型号: | PFC500-1028M |
厂家: | BEL FUSE INC. |
描述: | AC-DC Regulated Power Supply Module, 500W 输出元件 |
文件: | 总4页 (文件大小:176K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
PFC500/PDC500 Series Data Sheet
Features
•
•
RoHS lead solder exemption compliant
Power Factor Correction meets EN61000-3-2 (AC input
versions)
•
•
•
•
•
•
•
Fully-regulated outputs
Remote sense
Logic level Inhibit
Current Share, Power Fail, and Power Good Signals
Overtemperature, overvoltage, and overcurrent protected
Available with metric or SAE mountings
Input transient & ESD compliance to
EN61000-4-2/-3/-4/-5
•
•
Fan output voltage and optional fan
Optional isolation diodes for parallel or redundant
operation
•
DC input versions (36-75VDC)
Description
The PFC500/PDC500 products of the PerFormanCe Power Series combine high performance midrange power with
high power density (4.4 watts/in3) and high reliability to meet the requirements of communications, commercial, and
industrial systems.
Providing tightly regulated DC power, the PFC500/PDC500 delivers full output performance with only 300 Linear Feet
per Minute (LFM) forced-air cooling (factory-installed fan optional). Main channel current sharing is provided for
redundant applications, and AC input units can be paralleled with DC input versions. Units are available with SAE
mountings or optional metric mountings.
The PFC500/PDC500 product line is approved to the latest international regulatory standards, and displays the CE
Mark.
Single-Output Model Selection
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT (NOTE 3)
LINE
LOAD
RIPPLE & NOISE
INITIAL SETTING
ACCURACY
MODEL
REGULATION REGULATION (NOTE 4) %p-p (NOTE 5)
PFC500-1024/PDC500-1024D 24V
21.6V to 26.4V
21A
0.5%
0.2%
1%
23.88V to 24.12V
(NOTE 1)
PFC500-1028 (NOTE 2)
PFC500-1048 (NOTE 2)
28V
48V
25.2V to 30.8V
46.0V to 56.0V
17.9A
10.4A
0.5%
0.5%
0.2%
0.5%
1%
1%
27.86V to 28.14V
47.52V to 48.48V
NOTES: 1) For AC input, use PFC500 prefix; use PDC500 prefix for DC input versions.
2) Consult factory for availability of 28V and 48V units with DC input.
3) Output currents ratings are expressed with 300 LFM forced air.
4) Remote sense connected. See Application Note #P1 for load regulation when using the D option for 24V units.
5) Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
For ripple/noise on “D” option models, see options data on page 3.
PFC500 Input Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
85
47
85
20
NOM
MAX
264
63
UNITS
Input Voltage - AC
Input Frequency
Brown Out Protection
Hold-Up Time
Continuous input range.
AC Input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Over full AC input voltage range at full rated load.
85 VAC at full rated load.
VAC
Hz
VAC
ms
Input Current
7.8
ARMS
Input Protection
Inrush Surge Current
Non-user serviceable internally located AC input line fuse, F10A, 250V.
Internally limited by thermistor, one cycle, 25°C.
110 VAC
220 VAC
35
65
APK
Power Factor
Operating Frequency
Per EN61000-3-2.
Switching frequency of main transformer.
0.98
W/VA
kHz
100
AUG 01, 2003 revised to JUL 13, 2006
Page 1 of 4
www.power-one.com
PFC500/PDC500 Series Data Sheet
PDC500 Input Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Input Voltage - DC
Continuous input range. Full power at 42-75 VDC.
Derate linearly from 40 VDC to 36 VDC, 400W.
36
75
VDC
Low Voltage Protection
Hold-up Time
Input Current
Lowest DC input voltage.
At full load over DC input range.
48 VDC at full rated load.
34
17
VDC
ms
ADC
14
Input Protection
Inrush Surge Current
Non-user serviceable internally located fuse.
Vin = 75 VDC, cold thermistor.
TBD
APK
Output Specifications (PFC500 and PDC500)
PARAMETER
CONDITIONS/DESCRIPTION
MIN
75
NOM
MAX
UNITS
Efficiency
Full rated load, 110 VAC (PFC500)/ 48VDC (PDC500).
%
Minimum loads
PFC/PDC500-1024
PFC500-1028
PFC500-1048
0.6
0.6
1.2
Amps
Watts
Ripple and Noise
Output Power
Full load, 20 MHz bandwidth.
300 LFM forced air cooling required for operation. See optional fan.
Continuous power, multiple output models. PDC500 requires derating below
42 VDC; see PDC500 input specifications.
See Model Selection Charts
500
Overshoot / Undershoot
Regulation
Output voltage overshoot/undershoot at turn-on.
Without connection of remote sense.
0
V
PFC/PDC500-1024
PFC500-1028
PFC500-1048
0.8
0.7
1.0
%
Transient Response
Recovery time, to within 1% of initial set point due to a 50-100% load change,
3% max. deviation.
1
ms
Turn-on Delay
Turn-on Rise Time
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
1
Sec
ms
10
Interface Signals and Internal Protection (PFC500 and PDC500)
PARAMETER
CONDITIONS/DESCRIPTION
MIN
27.0
32.0
60.0
NOM
MAX
30.7
35.0
70.0
UNITS
Overvoltage Protection
PFC/PDC500-1024
PFC500-1028
PFC500-1048
V
Overload Protection
Overtemperature Protection
Remote Sense
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
System shutdown due to excessive internal temperature, automatic reset.
Total voltage compensation for cable losses with respect to the main output.
Accuracy of shared current with up to 6 parallel units.
250
10
mV
%
Current Share
Inhibit
TTL compatible logic signal will inhibit outputs by the application of a logic low signal.
An open circuit or external TTL high signal allows normal operation.
Input Power
Fail Warning
Power Good
TTL compatible logic signal. Time before regulation dropout due to
loss of input power at 110 VAC.
4
ms
V
TTL compatible signal. Signal is low if main output is greater
or less than 10% of nominal. For models without the
PFC/PDC500-1024
PFC500-1028
22.08
25.20
44.20
27.36
30.80
54.72
“D” option, internal pull-up resistor is 1kꢀꢁ For “D” option, PFC500-1048
pull-up resistor is 475ꢀ. See Apps Note #P1 for details.
Fan Voltage
Provides 170mA current to user supplied fan if fan option is not selected.
12
V
AUG 01, 2003 revised to JUL 13, 2006
Page 2 of 4
www.power-one.com
PFC500/PDC500 Series Data Sheet
Safety, Regulatory, and EMI Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Agency Approvals
UL1950. UL 60950 / CSA60950-00 (cULus Mark)
EN60950 (TÜV). PDC500 (Pending).
Meets reinforced insulation of IEC60950.
Approved
Dielectric Withstand
Electromagnetic Interference
FCC CFR title 47 Part 15 Sub-Part B - Conducted.
EN55022 / CISPR 22 Conducted.
B
B
Class
ESD Susceptibility
Per EN61000-4-2, level 4.
Per EN61000-4-3, level 3.
Per EN61000-4-4, level 4.
Per EN61000-4-4, level 4.
8
10
4
TBD
1
2
0.5
0.5
kV
V/M
kV
Radiated Susceptibility
EFT/Burst (PFC500)
EFT/Burst (PDC500)
Input Transient Protection
kV
PFC500 Per EN61000-4-5 class 3. PDC500 (class 2)
Line to Line (PFC500)
Line to Ground (PFC500)
Line to Line (PDC500)
kV
Line to Ground (PDC500)
Insulation Resistance
Input to output.
10
Mꢀ
Leakage Current (PFC500)
Per EN60950, 264 VAC.
2.0
mA
Environmental Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Altitude
Operating.
Non-Operating.
10k
40k
ASL Ft.
ASL Ft.
Operating Temperature
At 100% load
At 50% load
0
0
50
70
°C
°C
Derate linearly above 50°C by 2.5% per °C.
Storage Temperature
Forced Air Cooling
-55
85
°C
Forced air cooling of 300 LFM (400 LFM for PDC500) is required if the internal
fan is not specified Cooling air velocity is measured at the output exiting window
(2.5” x 5”). Airflow direction is from the input section to the output section.
Temperature Coefficient
Relative Humidity
Shock
0°C to 70°C (after 15 minute warm-up).
Non-Condensing.
Operating: 10 3mSec, 3 axis, Half Sine.
0.02
0.05
95
20
40
%/°C
%RH
5
G
Non-operating: 10 3mSec, 3 axis, Half Sine.
Vibration
Operating:
5-32Hz
32-2000Hz Sinusoidal
0.02
1
in (DA)
GPK
Non-operating:
6.15
GRMS
Options
DESCRIPTION
NOTES
SIZE IMPACT
Isolation Diodes
Add “D” as a suffix to the model number to order factory installed isolation diodes
for parallel or redundant operation. For 24V models with the “D” option, external caps
are required to meet the 1% noise/ripple spec. Power Good has a pull-up
resistor of 475ꢀ on the 24V models. See Application Note #P1 for details.
N/A
Fan
Add “F” as a suffix to the model number to order integral fan.
Fan provides the required 300 LFM (400 LFM for PDC500) of forced air cooling,
or otherwise provided by the end user.
10.50" x 5.00" x 2.50"
(266.7mm x 127.0mm x 63.5mm)
Metric Mounting
Add “M” as a suffix to the model number to order chassis with
M4 x 0.7 mounting inserts.
N/A
AUG 01, 2003 revised to JUL 13, 2006
Page 3 of 4
www.power-one.com
PFC500/PDC500 Series Data Sheet
Overall Size: 9.00" x 5.00" x 2.50" (228.6mm x 127.0mm x 63.5mm)
Overall Length With Fan: 10.50" (266.7mm)
Weight: 4.3 lb (1.95 kg)
SUGGESTED AIRFLOW *
DC+ or
DC- or
Input and Output Connections: 6-32 Screw Terminal on 0.375" (9.5mm) centers
Chassis: 0.090" (2.3mm) Aluminum Alloy, With Clear Finish
* Airflow should be measured at the exiting window (5” x 2.5”).
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of
the respective divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
AUG 01, 2003 revised to JUL 13, 2006
Page 4 of 4
www.power-one.com
相关型号:
©2020 ICPDF网 联系我们和版权申明