PFC500-1028M [BEL]

AC-DC Regulated Power Supply Module, 500W;
PFC500-1028M
型号: PFC500-1028M
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

AC-DC Regulated Power Supply Module, 500W

输出元件
文件: 总4页 (文件大小:176K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
PFC500/PDC500 Series Data Sheet  
Features  
RoHS lead solder exemption compliant  
Power Factor Correction meets EN61000-3-2 (AC input  
versions)  
Fully-regulated outputs  
Remote sense  
Logic level Inhibit  
Current Share, Power Fail, and Power Good Signals  
Overtemperature, overvoltage, and overcurrent protected  
Available with metric or SAE mountings  
Input transient & ESD compliance to  
EN61000-4-2/-3/-4/-5  
Fan output voltage and optional fan  
Optional isolation diodes for parallel or redundant  
operation  
DC input versions (36-75VDC)  
Description  
The PFC500/PDC500 products of the PerFormanCe Power Series combine high performance midrange power with  
high power density (4.4 watts/in3) and high reliability to meet the requirements of communications, commercial, and  
industrial systems.  
Providing tightly regulated DC power, the PFC500/PDC500 delivers full output performance with only 300 Linear Feet  
per Minute (LFM) forced-air cooling (factory-installed fan optional). Main channel current sharing is provided for  
redundant applications, and AC input units can be paralleled with DC input versions. Units are available with SAE  
mountings or optional metric mountings.  
The PFC500/PDC500 product line is approved to the latest international regulatory standards, and displays the CE  
Mark.  
Single-Output Model Selection  
OUTPUT  
VOLTAGE  
ADJUSTMENT  
RANGE  
MAXIMUM OUTPUT  
CURRENT (NOTE 3)  
LINE  
LOAD  
RIPPLE & NOISE  
INITIAL SETTING  
ACCURACY  
MODEL  
REGULATION REGULATION (NOTE 4) %p-p (NOTE 5)  
PFC500-1024/PDC500-1024D 24V  
21.6V to 26.4V  
21A  
0.5%  
0.2%  
1%  
23.88V to 24.12V  
(NOTE 1)  
PFC500-1028 (NOTE 2)  
PFC500-1048 (NOTE 2)  
28V  
48V  
25.2V to 30.8V  
46.0V to 56.0V  
17.9A  
10.4A  
0.5%  
0.5%  
0.2%  
0.5%  
1%  
1%  
27.86V to 28.14V  
47.52V to 48.48V  
NOTES: 1) For AC input, use PFC500 prefix; use PDC500 prefix for DC input versions.  
2) Consult factory for availability of 28V and 48V units with DC input.  
3) Output currents ratings are expressed with 300 LFM forced air.  
4) Remote sense connected. See Application Note #P1 for load regulation when using the D option for 24V units.  
5) Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.  
For ripple/noise on “D” option models, see options data on page 3.  
PFC500 Input Specifications  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
85  
47  
85  
20  
NOM  
MAX  
264  
63  
UNITS  
Input Voltage - AC  
Input Frequency  
Brown Out Protection  
Hold-Up Time  
Continuous input range.  
AC Input.  
Lowest AC input voltage that regulation is maintained with full rated loads.  
Over full AC input voltage range at full rated load.  
85 VAC at full rated load.  
VAC  
Hz  
VAC  
ms  
Input Current  
7.8  
ARMS  
Input Protection  
Inrush Surge Current  
Non-user serviceable internally located AC input line fuse, F10A, 250V.  
Internally limited by thermistor, one cycle, 25°C.  
110 VAC  
220 VAC  
35  
65  
APK  
Power Factor  
Operating Frequency  
Per EN61000-3-2.  
Switching frequency of main transformer.  
0.98  
W/VA  
kHz  
100  
AUG 01, 2003 revised to JUL 13, 2006  
Page 1 of 4  
www.power-one.com  
PFC500/PDC500 Series Data Sheet  
PDC500 Input Specifications  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Input Voltage - DC  
Continuous input range. Full power at 42-75 VDC.  
Derate linearly from 40 VDC to 36 VDC, 400W.  
36  
75  
VDC  
Low Voltage Protection  
Hold-up Time  
Input Current  
Lowest DC input voltage.  
At full load over DC input range.  
48 VDC at full rated load.  
34  
17  
VDC  
ms  
ADC  
14  
Input Protection  
Inrush Surge Current  
Non-user serviceable internally located fuse.  
Vin = 75 VDC, cold thermistor.  
TBD  
APK  
Output Specifications (PFC500 and PDC500)  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
75  
NOM  
MAX  
UNITS  
Efficiency  
Full rated load, 110 VAC (PFC500)/ 48VDC (PDC500).  
%
Minimum loads  
PFC/PDC500-1024  
PFC500-1028  
PFC500-1048  
0.6  
0.6  
1.2  
Amps  
Watts  
Ripple and Noise  
Output Power  
Full load, 20 MHz bandwidth.  
300 LFM forced air cooling required for operation. See optional fan.  
Continuous power, multiple output models. PDC500 requires derating below  
42 VDC; see PDC500 input specifications.  
See Model Selection Charts  
500  
Overshoot / Undershoot  
Regulation  
Output voltage overshoot/undershoot at turn-on.  
Without connection of remote sense.  
0
V
PFC/PDC500-1024  
PFC500-1028  
PFC500-1048  
0.8  
0.7  
1.0  
%
Transient Response  
Recovery time, to within 1% of initial set point due to a 50-100% load change,  
3% max. deviation.  
1
ms  
Turn-on Delay  
Turn-on Rise Time  
Time required for initial output voltage stabilization.  
Time required for output voltage to rise from 10% to 90%.  
1
Sec  
ms  
10  
Interface Signals and Internal Protection (PFC500 and PDC500)  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
27.0  
32.0  
60.0  
NOM  
MAX  
30.7  
35.0  
70.0  
UNITS  
Overvoltage Protection  
PFC/PDC500-1024  
PFC500-1028  
PFC500-1048  
V
Overload Protection  
Overtemperature Protection  
Remote Sense  
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.  
System shutdown due to excessive internal temperature, automatic reset.  
Total voltage compensation for cable losses with respect to the main output.  
Accuracy of shared current with up to 6 parallel units.  
250  
10  
mV  
%
Current Share  
Inhibit  
TTL compatible logic signal will inhibit outputs by the application of a logic low signal.  
An open circuit or external TTL high signal allows normal operation.  
Input Power  
Fail Warning  
Power Good  
TTL compatible logic signal. Time before regulation dropout due to  
loss of input power at 110 VAC.  
4
ms  
V
TTL compatible signal. Signal is low if main output is greater  
or less than 10% of nominal. For models without the  
PFC/PDC500-1024  
PFC500-1028  
22.08  
25.20  
44.20  
27.36  
30.80  
54.72  
“D” option, internal pull-up resistor is 1kꢀꢁ For “D” option, PFC500-1048  
pull-up resistor is 475. See Apps Note #P1 for details.  
Fan Voltage  
Provides 170mA current to user supplied fan if fan option is not selected.  
12  
V
AUG 01, 2003 revised to JUL 13, 2006  
Page 2 of 4  
www.power-one.com  
PFC500/PDC500 Series Data Sheet  
Safety, Regulatory, and EMI Specifications  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Agency Approvals  
UL1950. UL 60950 / CSA60950-00 (cULus Mark)  
EN60950 (TÜV). PDC500 (Pending).  
Meets reinforced insulation of IEC60950.  
Approved  
Dielectric Withstand  
Electromagnetic Interference  
FCC CFR title 47 Part 15 Sub-Part B - Conducted.  
EN55022 / CISPR 22 Conducted.  
B
B
Class  
ESD Susceptibility  
Per EN61000-4-2, level 4.  
Per EN61000-4-3, level 3.  
Per EN61000-4-4, level 4.  
Per EN61000-4-4, level 4.  
8
10  
4
TBD  
1
2
0.5  
0.5  
kV  
V/M  
kV  
Radiated Susceptibility  
EFT/Burst (PFC500)  
EFT/Burst (PDC500)  
Input Transient Protection  
kV  
PFC500 Per EN61000-4-5 class 3. PDC500 (class 2)  
Line to Line (PFC500)  
Line to Ground (PFC500)  
Line to Line (PDC500)  
kV  
Line to Ground (PDC500)  
Insulation Resistance  
Input to output.  
10  
Mꢀ  
Leakage Current (PFC500)  
Per EN60950, 264 VAC.  
2.0  
mA  
Environmental Specifications  
PARAMETER  
CONDITIONS/DESCRIPTION  
MIN  
NOM  
MAX  
UNITS  
Altitude  
Operating.  
Non-Operating.  
10k  
40k  
ASL Ft.  
ASL Ft.  
Operating Temperature  
At 100% load  
At 50% load  
0
0
50  
70  
°C  
°C  
Derate linearly above 50°C by 2.5% per °C.  
Storage Temperature  
Forced Air Cooling  
-55  
85  
°C  
Forced air cooling of 300 LFM (400 LFM for PDC500) is required if the internal  
fan is not specified Cooling air velocity is measured at the output exiting window  
(2.5” x 5”). Airflow direction is from the input section to the output section.  
Temperature Coefficient  
Relative Humidity  
Shock  
0°C to 70°C (after 15 minute warm-up).  
Non-Condensing.  
Operating: 10 3mSec, 3 axis, Half Sine.  
0.02  
0.05  
95  
20  
40  
%/°C  
%RH  
5
G
Non-operating: 10 3mSec, 3 axis, Half Sine.  
Vibration  
Operating:  
5-32Hz  
32-2000Hz Sinusoidal  
0.02  
1
in (DA)  
GPK  
Non-operating:  
6.15  
GRMS  
Options  
DESCRIPTION  
NOTES  
SIZE IMPACT  
Isolation Diodes  
Add “D” as a suffix to the model number to order factory installed isolation diodes  
for parallel or redundant operation. For 24V models with the “D” option, external caps  
are required to meet the 1% noise/ripple spec. Power Good has a pull-up  
resistor of 475on the 24V models. See Application Note #P1 for details.  
N/A  
Fan  
Add “F” as a suffix to the model number to order integral fan.  
Fan provides the required 300 LFM (400 LFM for PDC500) of forced air cooling,  
or otherwise provided by the end user.  
10.50" x 5.00" x 2.50"  
(266.7mm x 127.0mm x 63.5mm)  
Metric Mounting  
Add “M” as a suffix to the model number to order chassis with  
M4 x 0.7 mounting inserts.  
N/A  
AUG 01, 2003 revised to JUL 13, 2006  
Page 3 of 4  
www.power-one.com  
PFC500/PDC500 Series Data Sheet  
Overall Size: 9.00" x 5.00" x 2.50" (228.6mm x 127.0mm x 63.5mm)  
Overall Length With Fan: 10.50" (266.7mm)  
Weight: 4.3 lb (1.95 kg)  
SUGGESTED AIRFLOW *  
DC+ or  
DC- or  
Input and Output Connections: 6-32 Screw Terminal on 0.375" (9.5mm) centers  
Chassis: 0.090" (2.3mm) Aluminum Alloy, With Clear Finish  
* Airflow should be measured at the exiting window (5” x 2.5”).  
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical  
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of  
the respective divisional president of Power-One, Inc.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the  
date manufactured. Specifications are subject to change without notice.  
AUG 01, 2003 revised to JUL 13, 2006  
Page 4 of 4  
www.power-one.com  

相关型号:

PFC500-1048

PerFormanCe POWER
POWER-ONE

PFC500-1048F

PSU 500W 1 O/P
POWER-ONE

PFC500-1048FM

AC-DC Regulated Power Supply Module, 500W
BEL

PFC500-1048G

Power Factor Correction meets EN61000-3-2 (AC input versions)
BEL

PFCA

Thin Film Surface Mount Attenuators
TTELEC

PFCA120650R-10D0

Thin Film Surface Mount Attenuators
TTELEC

PFCA120650R-1D00

Thin Film Surface Mount Attenuators
TTELEC

PFCA120650R-20D0

Thin Film Surface Mount Attenuators
TTELEC

PFCA120650R-2D00

Thin Film Surface Mount Attenuators
TTELEC

PFCA120650R-3D00

Thin Film Surface Mount Attenuators
TTELEC

PFCA120650R-4D00

Thin Film Surface Mount Attenuators
TTELEC

PFCA120650R-5D00

Thin Film Surface Mount Attenuators