PSL156-9R [BEL]

DC-DC Regulated Power Supply Module;
PSL156-9R
型号: PSL156-9R
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

DC-DC Regulated Power Supply Module

文件: 总17页 (文件大小:2117K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
PSC, PSL Series Data Sheet  
Positive Switching Regulators  
®
107  
4.2"  
3 U  
32  
1.3"  
88  
3.5"  
151  
5.9"  
168  
37  
1.5"  
8 TE  
6.6"  
Features  
Input voltage up to 144 VDC  
Single output of 3.3 to 48 VDC  
No input-to-output isolation  
Description  
High efficiency up to 97%  
The PSC and PSL Series positive switching regulators are  
designed as power supplies for electronic systems, where no  
input-to-output isolation is required. Their major advantages  
include a high level of efficiency, high reliability, low output  
ripple, and excellent dynamic response. Models with input  
voltages up to 144 V are specially designed for secondary  
switched and battery-driven mobile applications. The  
converters are suitable for railway applications according to  
EN 50155 and EN 50121.  
Extremely wide input voltage range  
• Low input-to-output differential voltage  
Very good dynamic properties  
Input undervoltage lockout  
• Output voltage adjustment and inhibit function  
Continuously no-load and short-circuit proof  
All boards are coated with a protective lacquer  
Two type of housings are available allowing operation up to  
71 °C. The PSC Series is designed for wall or chassis  
mounting with faston connections, whereas the PSL Series is  
designed for insertion into a 19" DIN-rack and exhibits a H11  
connector.  
Safety-compliant to IEC/EN 60950-1 and UL/CSA  
60950-1 2nd Ed.  
Various options are available to adapt the converters to  
different applications.  
Table of Contents  
Page  
Page  
Electromagnetic Compatibility (EMC) ................................ 12  
Immunity to Environmental Conditions.............................. 13  
Mechanical Data ................................................................. 14  
Safety and Installation Instructions .................................... 15  
Description of Options ....................................................... 16  
Accessories........................................................................ 17  
Description ........................................................................... 1  
Model Selection .................................................................... 2  
Functional Description ......................................................... 4  
Electrical Input Data ............................................................. 5  
Electrical Output Data ........................................................... 7  
Auxiliary Functions .............................................................. 10  
BCD20027-G Rev AA, 18-May-2011  
Page 1 of 17  
www.power-one.com  
PSC, PSL Series Data Sheet  
Positive Switching Regulators  
®
Model Selection  
Table 1: PSC Series  
Output  
voltage  
Vo nom [V]  
Output  
current  
Io nom [A]  
Operating input  
voltage range  
Vi [V]  
Nom. input  
voltage  
Vi nom [V]  
Efficiency 2  
Type  
designation  
Options  
ηmin [%] η typ [%]  
3.3  
12  
7– 40  
20  
77  
PSC3E12-2  
i, R, G  
5.1  
5.1  
5.1  
10  
11  
12  
8 – 80  
8 – 40  
7 – 40  
40  
20  
20  
77.5  
78  
83.5  
79  
79  
85.5  
PSC5A10-7iR  
PSC5A11-2  
PSC5A12-7iR  
-9, L, P, C, D, D1, G  
i, R, G  
-9, L, P, C, D, D1, G  
12  
12  
12  
6
8
9
18 – 1441  
15 – 80  
15 – 40  
60  
40  
30  
88  
88  
89  
89  
90  
90  
PSC126-7iR  
PSC128-7iR  
PSC129-2  
-9, L, P, C, D, D1, G  
-9, L, P, C, D, D1, G  
i, R, G  
15  
15  
15  
6
8
9
22 – 1441  
19 – 80  
19 – 40  
60  
40  
30  
89  
90  
91  
91  
92.5  
93.5  
PSC156-7iR  
PSC158-7iR  
PSC159-2  
-9, L, P, C, D, D1, G  
-9, L, P, C, D, D1, G  
i, R, G  
24  
24  
24  
6
8
9
31 – 1441  
29 – 80  
29 – 60  
60  
40  
40  
93  
93  
94  
94  
95  
96  
PSC246-7iR  
PSC248-7iR  
PSC249-2  
-9, L, P, C, D, D1, G  
-9, L, P, C, D, D1, G  
i, R, G  
36  
36  
6
8
44 – 1441  
42 – 80  
80  
60  
95  
95  
96  
96.5  
PSC366-7iR  
PSC368-7iR  
-9, L, P, C, D, D1, G  
-9, L, P, C, D, D1, G  
48  
6
58 –144 1  
80  
96  
97  
PSC486-7iR  
-9, L, P, D, D1, G  
1
Surges up to 156 V for 2 s; see Electrical Input Data  
2
Efficiency at Vi nom and Io nom  
.
Table 2: PSL Series  
Output  
voltage  
Vo nom [V]  
Output  
current  
Io nom [A]  
Operating input  
voltage range  
Vi [V]  
Nom. input  
voltage  
Vi nom [V]  
Efficiency 2  
ηmin [%] η typ [%]  
Type  
designation  
Options  
5.1  
5.1  
5.1  
10  
11  
12  
8 – 80  
8 – 40  
7 – 40  
40  
20  
20  
77.5  
78  
83.5  
79  
79  
85.5  
PSL5A10-7R  
PSL5A11-2R  
PSL5A12-7R  
-9, L, i, P, C, D, D1, K, G  
-
-9, L, i, P, C, D, D1, K, G  
12  
12  
12  
6
8
9
18 – 1441  
15 – 80  
15 – 40  
60  
40  
30  
88  
89  
89  
89  
90  
90  
PSL126-7R  
PSL128-7R  
PSL129-2R  
-9, L, i, P, C, D, D1, K, G  
-9, L, i, P, C, D, D1, K, G  
-
15  
15  
15  
6
8
9
22 – 1441  
19 – 80  
19 – 40  
60  
40  
30  
89  
90  
91  
91  
92.5  
93.5  
PSL156-7R  
PSL158-7R  
PSL159-2R  
-9, L, i, P, C, D, D1, K, G  
-9, L, i, P, C, D, D1, K, G  
-
24  
24  
24  
6
8
9
31 – 1441  
29 – 80  
29 – 60  
60  
40  
40  
93  
93  
94  
94  
95  
96  
PSL246-7R  
PSL248-7R  
PSL249-2R  
-9, L, i, P, C, D, D1, K, G  
-9, L, i, P, C, D, D1, K, G  
-
36  
36  
6
8
44 – 1441  
42 – 80  
80  
60  
95  
95  
96  
96.5  
PSL366-7R  
PSL368-7R  
-9, L, i, P, C, D, D1, K, G  
-9, L, i, P, C, D, D1, K, G  
48  
6
58 –144 1  
80  
96  
97  
PSL486-7R  
-9, L, i, P, D, D1, K, G  
1
Surges up to 156 V for 2 s  
Efficiency at Vi nom and Io nom  
2
.
BCD20027-G Rev AA, 18-May-2011  
Page 2 of 17  
www.power-one.com  
PSC, PSL Series Data Sheet  
Positive Switching Regulators  
®
Part Number Description  
PSC 12 6 -7 L i R P C D G  
PSC Series  
Positive switching regulator in case C03 .................... PSC  
Nominal output voltage in volt.............................. 3.3 to 48  
Nominal output current in ampere .......................... 6 to 12  
Operational ambient temperature range TA  
–10 to 50 °C ........................................................ -2  
–25 to 71 °C ........................................................ -7  
–40 to 71 °C (option) ........................................... -9  
Input filter (option) ............................................................ L  
Inhibit input ....................................................................... i  
Control input for output voltage adjustment 1 .................. R  
Potentiometer 1 (option) ................................................... P  
Thyristor crowbar (option) ............................................... C  
Input/output voltage monitor (option) ........................ D, D1  
RoHS-compliant for all 6 substances ............................. G  
1
Feature R excludes option P and vice versa.  
Example: PSC126-7LiPC designates a positive switching regulator with a 12 V, 6 A output, ambient temperature range of  
–25 to 71 °C, input filter, inhibit input, output adjust potentiometer, and thyristor crowbar.  
PSL Series  
PSL 12 6 -7 L i R P C D K G  
Positive switching regulator in case L04..................... PSL  
Nominal output voltage in volt.............................. 5.1 to 48  
Nominal output current in ampere .......................... 6 to 12  
Operational ambient temperature range TA  
–10 to 50 °C ........................................................ -2  
–25 to 71 °C ........................................................ -7  
–40 to 71 °C (option) ........................................... -9  
Input filter (option) ............................................................ L  
Inhibit input ....................................................................... i  
Control input for output voltage adjustment 1 .................. R  
Potentiometer 1 (option) ................................................... P  
Thyristor crowbar (option) ............................................... C  
Input/output voltage monitor (option) ........................ D, D1  
Coding strip (option) ........................................................ K  
RoHS-compliant for all 6 substances ............................. G  
1
Feature R excludes options i and P and vice versa.  
Example: PSL126-7LiPC designates a positive switching regulator with a 12 V, 6 A output, ambient temperature range of  
–25 to 71 °C, input filter, inhibit input, output adjust potentiometer, and thyristor crowbar.  
Produkt Marking  
Type designation, applicable safety approval marks,  
warnings, pin allocation, Power-One patent nos., and  
company logo.  
protection degree, batch no., serial no., and data code including  
production site, version (modification status), and date of  
production.  
Identification of LED and optional potentiometers. Label with  
input voltage range, nominal output voltage and current,  
BCD20027-G Rev AA, 18-May-2011  
Page 3 of 17  
www.power-one.com  
PSC, PSL Series Data Sheet  
Positive Switching Regulators  
®
Functional Description  
complished by varying the duty cycle (on to off ratio) of the  
power switch.  
The switching regulators are designed using the buck  
converter topology. The input is not electrically isolated from  
the output. During the on period of the switching transistor,  
current is transferred to the output, and energy is stored in the  
output choke. During the off period, this energy forces the  
current to continue flowing through the output, to the load, and  
back through the freewheeling diode. Regulation is ac-  
These regulators are ideal for a wide range of applications,  
where input to output isolation is not necessary, or where  
already provided by an external front end (e.g., a transformer  
with rectifier). To optimize customer’s needs, additional options  
and accessories are available.  
03018a  
Io  
I i  
Vi+  
Vo+  
Fuse  
(option C)  
D
i
Control circuit  
Vi  
Vo  
Option C  
R
G
Gi–  
Vt  
V
o
Go–  
Option D  
Option P  
Fig. 1  
Block diagram PSC  
03021a  
Io  
14  
17  
5
Vo+  
I i  
29  
Vi+  
Fuse  
(Option  
C)  
26  
D
Control circuit  
Vi  
Vo  
Option  
C
R (or i)  
Go–  
20  
23  
2
8
Gi–  
Vt  
Option D  
Vo  
11  
32  
Option P  
Fig. 2  
Block diagram PSL  
BCD20027-G Rev AA, 18-May-2011  
Page 4 of 17  
www.power-one.com  
PSC, PSL Series Data Sheet  
Positive Switching Regulators  
®
Electrical Input Data  
General Conditions: TA = 25 °C, unless TC is specified  
Table 3a: Input data  
Input  
PSC3E12-2  
PSC5A11-2  
PSC129-2  
Unit  
PSL5A11-2R  
PSL129-2R  
Characteristics  
Conditions  
min  
typ max min  
40  
typ max  
min  
typ  
max  
Vi  
Operating input voltage  
Io = 0 – Io nom  
TC min TC max  
7
8
40  
15  
40  
3
V
Vio min Min. diff. voltage Vi Vo  
2.7  
2.9  
Vi UVL  
Ii 0  
Undervoltage lockout  
No load input current  
4.7  
7.3  
50  
150  
75  
5
7.3  
Io = 0, Vi min Vi max  
50  
50  
mA  
A
Iinr p  
Peak value of inrush current  
Vi nom  
PSC  
PSL  
150  
150  
75  
5
tinr r  
Rise time of inrush current  
EN 55011,0.15 – 30 MHz  
5
µs  
Vi RFI  
Vi nom, Io nom,  
A
A
A
Class  
Table 3b: Input data  
Input  
PSC159-2  
PSC249-2  
Unit  
PSL159-2R  
PSL249-2R  
Characteristics  
Conditions  
min  
typ  
max min  
typ max  
Vi  
Operating input voltage  
Io = 0 – Io nom  
TC min TC max  
19  
40  
4
29  
60  
V
Vio min Min. diff. voltage Vi Vo  
5
Vi UVL  
Ii 0  
Iinr p  
tinr r  
Undervoltage lockout  
7.3  
12  
50  
250  
5
No load input current  
Io = 0, Vi min Vi max  
50  
mA  
A
Peak value of inrush current  
Rise time of inrush current  
EN 55011,0.15 – 30 MHz  
Vi nom  
250  
5
µs  
Vi RFI  
Vi nom, Io nom  
A
A
Class  
Table 3c: Input data  
Input  
PSC5A12  
PSL5A12  
PSC5A10  
PSL5A10  
PSC128  
PSL128  
Unit  
Characteristics  
Conditions  
min  
typ  
max min  
typ max  
min  
typ  
max  
80  
Vi  
Operating input voltage  
Io = 0 – Io nom  
TC min TC max  
7
40  
8
80  
15  
V
Viomin Min. diff. voltage Vi Vo  
1.9  
2.9  
3
Vi UVL  
Ii 0  
Undervoltage lockout  
No load input current  
6.3  
7.3  
40  
7.3  
Io = 0, Vi min Vi max  
45  
35  
mA  
A
Iinr p  
Peak value of inrush current  
Vi nom  
without L  
150  
250  
5
250  
350  
5
250  
350  
5
with opt. L  
without L  
with opt. L  
tinr r  
Rise time of inrush current  
EN 55011, 0.15 – 30 MHz  
µs  
25  
25  
25  
Vi RFI  
Vi nom, Io nom  
B 1  
B 1  
B 1  
Class  
1
With option L and an additional external input cap Ci = 120 µF/100 V, e.g., Nichicon or similar  
BCD20027-G Rev AA, 18-May-2011  
Page 5 of 17  
www.power-one.com  
PSC, PSL Series Data Sheet  
Positive Switching Regulators  
®
Table 3d: Input data. General Conditions as per table 3a  
Input  
PSC158  
PSL158  
PSC248  
PSL248  
PSC368  
PSL368  
Unit  
Characteristics  
Conditions  
min  
typ  
max min  
typ max  
min  
typ  
max  
80  
Vi  
Operating input voltage  
Io = 0 – Io nom  
TC min TC max  
19  
80  
4
29  
80  
5
42  
V
Vio min Min. diff. voltage Vi Vo  
6
Vi UVL  
Ii 0  
Undervoltage lockout  
No load input current  
7.3  
12  
19  
Io = 0, Vi min Vi max  
35  
35  
40  
mA  
A
Iinr p  
Peak value of inrush current  
Vi nom  
without L  
250  
350  
5
250  
350  
5
250  
350  
5
with opt. L  
without L  
with opt. L  
tinr r  
Rise time of inrush current  
µs  
25  
25  
25  
Vi RFI  
EN 55011,0.15 – 30 MHz  
Vi nom, Io nom  
B 1  
B 1  
B 1  
Class  
1
With option L and an additional external input cap Ci = 120 µF/100 V, e.g., Nichicon or similar  
Table 3e: Input data  
Input  
PSC126  
PSL126  
PSC156  
PSL156  
PSA246  
PSC246  
Unit  
Characteristics  
Conditions  
min  
typ  
max min  
144 2 22  
6
typ max  
min  
typ  
max  
144 2  
7
Vi  
Operating input voltage  
Io = 0 – Io nom  
TC min TC max  
18  
144 2  
31  
V
Vio min Min. diff. voltage Vi Vo  
7
Vi UVL  
Ii 0  
Undervoltage lockout  
No load input current  
12  
15  
19  
Io = 0, Vi min Vi max  
35  
35  
35  
mA  
A
Iinr p  
Peak value of inrush current  
Vi nom  
without L  
250  
350  
5
250  
350  
5
250  
350  
5
with opt. L  
without L  
with opt. L  
tinr r  
Rise time of inrush current  
EN 55011,0.15 – 30 MHz  
µs  
25  
25  
25  
Vi RFI  
Vi nom, Io nom  
B 1  
B 1  
B 1  
Class  
1
With option L and an additional external input cap Ci = 120 µF/100 V, e.g., Nichicon or similar  
Surges up to 156 V for 2 s  
2
Table 3f: Input data  
Input  
PSC366  
PSL366  
PSC486  
PSL486  
Unit  
Characteristics  
Conditions  
min  
typ  
max min  
144 2 58  
8
typ max  
Vi  
Operating input voltage 1  
Io = 0 – Io nom  
TC min TC max  
44  
144 2  
10  
V
Vio min Min. diff. voltage Vi Vo  
Vi UVL  
Ii 0  
Undervoltage lockout  
No load input current  
29  
40  
Io = 0, Vi min Vi max  
40  
45  
mA  
A
Iinr p  
Peak value of inrush current  
Vi nom  
without L  
250  
350  
5
250  
350  
5
with opt. L  
without L  
with opt. L  
tinr r  
Rise time of inrush current  
EN 55011,0.15 – 30 MHz  
µs  
25  
25  
Vi RFI  
Vi nom, Io nom  
B 1  
B 1  
Class  
1
With option L and an additional external input cap Ci = 120 µF/100 V, e.g., Nichicon or similar  
Surges up to 156 V for 2 s  
2
BCD20027-G Rev AA, 18-May-2011  
Page 6 of 17  
www.power-one.com  
PSC, PSL Series Data Sheet  
Positive Switching Regulators  
®
04016  
External Input Circuitry  
Vo+  
Go–  
Vi+  
+
The sum of the lengths of the supply lines to the source or to  
the nearest capacitor 100 µF (a + b) should not exceed 5 m,  
unless option L is fitted. This option is recommended in order  
to prevent power line oscillations and reduce superimposed  
interference voltages.  
a
b
Gi–  
Fig. 3  
Switching regulator with long supply lines.  
Electrical Output Data  
General conditions:  
TA = 25 °C, unless TC is specified  
– R-input open (or Vo set to Vo nom with option P)  
Table 4a: Output data  
Output  
PSC3E12  
typ  
PSC5A11/PSL5A11  
PSC129/PSL129  
Unit  
Characteristics  
Conditions  
min  
3.25  
0
max min  
typ  
max  
5.15  
11.0  
14.3  
55  
min  
11.6  
0
typ  
max  
12.4  
9.0  
Vo  
Io  
Output voltage  
Vi nom, Io nom  
3.35 5.05  
V
A
Output current  
Vi min Vi max  
TC min TC max  
12.0  
0
IoL  
vo  
Output current limitation  
12.0  
15.6 11.0  
9.0  
11.7  
150  
160  
Output  
voltage  
noise  
Switching freq.  
Total  
Vi nom, Io nom  
IEC/EN 61204  
BW = 20 MHz  
55  
60  
mVpp  
mV  
60  
Vo V  
Vo l  
vo d  
Static line regulation  
Static load regulation  
Vi min Vi max, Io nom  
Vi nom, Io = 0 – Io nom  
100  
100  
100  
100  
240  
120  
Dynamic  
load  
regulation  
Voltage deviat.  
Recovery time  
Vi nom  
Io nom /  
150  
50  
130  
50  
360  
60  
1
3
Io nom  
td  
µs  
IEC/EN 61204  
αVo  
Temperature coefficient  
Vo/TC (TC min TC max  
Vi min Vi max  
Io = 0 – Io nom  
±0.02  
±0.02  
±0.02 %/K  
)
Table 4b Output data. General conditions as per table 4a  
Output  
PSC159/PSL159  
PSC249/PSL249  
Unit  
Characteristics  
Conditions  
min  
14.5  
0
typ  
max min  
15.5 23.3  
typ  
max  
24.7  
9.0  
Vo  
Io  
Output voltage  
Vi nom, Io nom  
V
A
Output current  
Vi min Vi max  
TC min TC max  
9.0  
11.7  
200  
210  
0
IoL  
vo  
Output current limitation  
9.0  
9.0  
11.7  
300  
210  
Output  
voltage  
noise  
Switching freq.  
Total  
Vi nom, Io nom  
IEC/EN 61204  
BW = 20 MHz  
mVpp  
mV  
Vo V  
Vo l  
vo d  
Static line regulation  
Static load regulation  
Vi min Vi max, Io nom  
Vi nom, Io = 0 – Io nom  
300  
150  
480  
240  
Dynamic  
load  
Voltage deviat.  
Recovery time  
Vi nom  
Io nom /  
450  
60  
700  
80  
1
3
Io nom  
td  
µs  
regulation  
IEC/EN 61204  
αVo  
Temperature coefficient  
Vo/TC (TC min TC max  
Vi min Vi max  
Io = 0 – Io nom  
±0.02  
±0.02  
%/K  
)
BCD20027-G Rev AA, 18-May-2011  
Page 7 of 17  
www.power-one.com  
PSC, PSL Series Data Sheet  
Positive Switching Regulators  
®
Table 4c: Output data. General conditions as per table 4a  
Output  
PSC5A12/PSL5A12 PSC5A10/PSL5A10  
PSC128/PSL128  
Unit  
Characteristics  
Conditions  
Vi nom, Io nom  
Vi min Vi max  
min  
5.07  
0
typ  
max min  
typ  
max  
5.13  
11.0  
14.3  
55  
min  
11.93  
0
typ  
max  
12.07  
9.0  
Vo  
Io  
Output voltage  
5.13 5.07  
V
A
Output current  
12.0  
0
T
C min TC max  
IoL  
vo  
Output current limitation  
12.0  
15.6 11.0  
9.0  
11.7  
150  
Output  
voltage  
noise  
Switching freq.  
Total  
Vi nom, Io nom  
IEC/EN 61204  
BW = 20 MHz  
55  
60  
mVpp  
mV  
60  
160  
Vo V  
Vo l  
vo d  
Static line regulation  
Static load regulation  
Vi min Vi max, Io nom  
Vi nom, Io = 0 – Io nom  
100  
100  
100  
100  
240  
120  
Dynamic  
load  
Voltage deviat.  
Recovery time  
Vi nom  
Io nom /  
150  
50  
130  
50  
360  
60  
1
3
Io nom  
td  
µs  
regulation  
IEC/EN 61204  
αVo  
Temperature coefficient  
Vo/TC (TC min TC max  
Vi min Vi max  
Io = 0 – Io nom  
±0.02  
±0.02  
±0.02 %/K  
)
Table 4d: Output data. General conditions as per table 4a  
Output  
PSC158/PSL158  
PSC248/PSL248  
typ max  
PSC368/PSL368  
Unit  
Characteristics  
Conditions  
Vi nom, Io nom  
Vi min Vi max  
min  
typ  
max min  
min typ  
max  
36.22  
8.0  
Vo  
Io  
Output voltage  
14.91  
0
15.09 23.68  
24.14 35.78  
V
A
Output current  
8.0  
10.4  
90  
0
8.0  
10.4  
150  
155  
0
T
C min TC max  
IoL  
vo  
Output current limitation  
8.0  
8.0  
8.0  
10.4  
190  
Output  
voltage  
noise  
Switching freq. Vi nom, Io nom  
50  
54  
55  
60  
80  
85  
mVpp  
mV  
IEC/EN 61204  
BW = 20 MHz  
Total  
94  
195  
Vo V  
Vo l  
vo d  
Static line regulation  
Static load regulation  
Vi min Vi max, Io nom  
Vi nom, Io = 0 – Io nom  
70  
30  
100  
45  
150  
120  
150  
80  
220  
160  
200  
125  
220  
100  
270  
160  
Dynamic  
load  
regulation  
Voltage deviat.  
Recovery time  
Vi nom  
Io nom /  
130  
60  
1
3
Io nom  
td  
µs  
IEC/EN 61204  
αVo  
Temperature coefficient  
Vo/TC (TC min TC max  
Vi min Vi max  
Io = 0 – Io nom  
±0.02  
±0.02  
±0.02 %/K  
)
Table 4e: Output data. General conditions as per table 4a  
Output  
PSC126/PSL126  
PSC156/PSL156  
PSC246/PSL246  
Unit  
Characteristics  
Conditions  
Vi nom, Io nom  
Vi min Vi max  
min  
typ  
max min  
12.07 14.91  
typ  
max  
15.09 23.86  
min  
typ  
max  
24.14  
6.0  
Vo  
Io  
Output voltage  
11.93  
0
V
A
Output current  
6.0  
7.8  
45  
0
6.0  
7.8  
70  
0
T
C min TC max  
IoL  
vo  
Output current limitation  
6.0  
6.0  
6.0  
7.8  
Output  
voltage  
noise  
Switching freq.  
Total  
Vi nom, Io nom  
IEC/EN 61204  
BW = 20 MHz  
30  
34  
50  
54  
50  
54  
70  
mVpp  
mV  
49  
74  
75  
Vo V  
Vo l  
vo d  
Static line regulation  
Static load regulation  
Vi min Vi max, Io nom  
Vi nom, Io = 0 – Io nom  
25  
60  
40  
25  
60  
40  
80  
80  
100  
Dynamic  
load  
Voltage deviat.  
Recovery time  
Vi nom  
Io nom /  
150  
50  
130  
50  
360  
60  
1
3
Io nom  
td  
µs  
regulation  
IEC/EN 61204  
αVo  
Temperature coefficient  
Vo/TC (TC min TC max  
Vi min Vi max  
Io = 0 – Io nom  
±0.02  
±0.02  
±0.02 %/K  
)
BCD20027-G Rev AA, 18-May-2011  
Page 8 of 17  
www.power-one.com  
PSC, PSL Series Data Sheet  
Positive Switching Regulators  
®
Table 4f: Output data. General conditions as per table 4a  
Output  
PSC366/PSL366  
PSC486/PSL486  
Unit  
Characteristics  
Conditions  
min  
typ  
max min  
36.22 47.71  
typ  
max  
48.29  
6.0  
Vo  
Io  
Output voltage  
Vi nom, Io nom  
35.78  
0
V
A
Output current  
Vi min Vi max  
TC min TC max  
6.0  
7.8  
90  
0
IoL  
vo  
Output current limitation  
6.0  
6.0  
7.8  
Output  
voltage  
noise  
Switching freq. Vi nom, Io nom  
50  
54  
55  
95  
110  
mVpp  
mV  
IEC/EN 61204  
BW = 20 MHz  
Total  
94  
115  
Vo V  
Vo l  
vo d  
Static line regulation  
Static load regulation  
Vi min Vi max, Io nom  
Vi nom, Io = 0 – Io nom  
200  
120  
140  
100  
300  
200  
100  
180  
150  
100  
200  
250  
Dynamic  
load  
Voltage deviat.  
Recovery time  
Vi nom  
Io nom /  
1
3
Io nom  
td  
µs  
regulation  
IEC/EN 61204  
αVo  
Temperature coefficient  
Vo/TC (TC min TC max  
Vi min Vi max  
Io = 0 – Io nom  
±0.02  
±0.02 %/K  
)
Vo  
Io/Io nom  
vod  
Vo 1%  
Vo 1%  
05031a  
1.0  
0.9  
vod  
forced  
cooling  
td  
td  
0.8  
0.7  
0.6  
0.5  
0.4  
0.3  
0.2  
0.1  
0
convection cooling  
t
TC max  
Io/Io nom  
1
0.5  
10 µs  
10 µs  
0
t
05102c  
Fig. 4  
TA  
TA min  
50  
60  
70  
80  
90  
°C  
Switching regulator with long supply lines.  
Fig. 5b  
Output current derating versus temperature (models -7 or -9)  
Thermal Considerations  
When a switching regulator is located in free, quasi-stationary  
operated at Io nom, the case temperature TC will be about 95 °C  
after the warm-up phase, measured at the measuring point of  
case temperature TC; see Mechanical Data.  
air (convection cooling) at a temperature TA = 71 °C and is  
Io/Io nom  
Under practical operating conditions, the ambient temperature  
TA may exceed 71 °C, provided that additional measures (heat  
sink, fan, etc.) are taken to ensure that the case temperature TC  
does not exceed its maximum value of 95 °C.  
05032a  
1.0  
0.9  
Forced  
cooling  
0.8  
0.7  
Example: Sufficient forced cooling allows TA max = 85 °C. A  
simple check of the case temperature TC (TC 95 °C) at full  
load ensures correct operation of the system.  
Convection cooling  
0.6  
TC max  
0.5  
0.4  
0.3  
0.2  
0.1  
0
TA  
TA min  
40  
60  
70  
80 [°C]  
50  
Fig. 5a  
Output current derating versus temperature (models -2)  
BCD20027-G Rev AA, 18-May-2011  
Page 9 of 17  
www.power-one.com  
PSC, PSL Series Data Sheet  
Positive Switching Regulators  
®
output protection is not designed to withstand externally  
applied overvoltages.  
Output Protection and Short Circuit Behaviour  
A voltage suppressor diode, which in worst case conditions  
fails into a short circuit (or a thyristor crowbar, option C),  
protects the output against an internally generated over-  
voltage. Such an overvoltage could occur due to a failure of  
either the control circuit or the switching transistor. The  
A constant current limitation circuit holds the output current  
almost constant, when an overload or a short circuit is applied  
to the output. It acts self-protecting and recovers automatically  
after removal of the overload or short circuit condition.  
Parallel and Series Connection  
Vo/Vo nom  
05033a  
Outputs of equal nominal voltages can be parallel-connected.  
However, the use of a single regulator with higher output  
power, is always the better solution.  
1.0  
Io nom  
0.8  
Io L  
In parallel-connected operation, one or several outputs may  
operate continuously at their current limit knee-point which will  
cause an increase of the heat generation. Consequently, the  
max. ambient temperature should be reduced by 10 K.  
0.6  
0.4  
0.2  
Outputs can be series-connected with any other regulator. In  
series-connection the maximum output current is limited by  
the lowest current limitation, but electrically separated source  
voltages are needed for each regulator.  
0
0.2  
0.4  
0.6  
0.8  
1.0  
1.2 Io/Io nom  
Fig. 6  
Overload, short-circuit behaviour Vo versus Io.  
Iinh [mA]  
Auxiliary Functions  
06034a  
5
i Inhibit (Remote On / Off)  
4
3
2
The inhibit input allows the switching regulator output to be  
disabled via a control signal. In systems with several  
converters, this feature can be used, for example, to control  
the activation sequence of the converters by a logic signal  
(TTL, C-MOS, etc.). An output voltage overshoot will not  
occur, when switching on or off.  
Output off  
Output on  
1
0
Vinh  
Note: With open i-input, the output is enabled.  
–20  
0
–40  
20  
40  
V
Fig. 7  
Typical inhibit current Iinh versus inhibit voltage Vinh  
Table 5: Inhibit characteristics  
06009a  
Characteristics  
Conditions  
min typ max Unit  
Vo+  
i
Vi+  
Vinh Inhibit input voltage Vo = on Vi min Vi max  
–50  
+0.8  
+50  
V
Iinh  
TC min TC max  
Vo = off  
+2.4  
t r Switch-on time  
t f Switch-off time  
Vi = Vi nom  
RL =Vo nom/Ionom  
130  
25  
ms  
mA  
Vinh  
Go–  
Gi–  
Ii inh Input current when inhibited Vi = Vi nom  
25  
Fig. 8  
Definition of Iinh and Vinh  
BCD20027-G Rev AA, 18-May-2011  
Page 10 of 17  
www.power-one.com  
PSC, PSL Series Data Sheet  
Positive Switching Regulators  
®
Vo/Vo nom  
1
06001  
LED Output Voltage Indicator  
0.1  
0
An LED indicator (yellow for PSC, green for PSL) is illuminated,  
when the output voltage is higher than approx. 3 V.  
t
tf  
tr  
Inhibit  
1
t
0
Fig. 9  
Output response as a function of inhibit signal  
R Control (Output Voltage Adjust)  
Note: With open R input, Vo Vo nom  
.
The output voltage Vo can either be adjusted with an external  
voltage source (Vext) or with an external resistor (Rext1 or Rext2).  
The adjustment range is 0 – 108% of Vo nom. The minimum  
differential voltage Vio min between input and output (see  
Electrical Input Data) should be maintained.  
a) Vo = 0 – Vo max, using Vext between R and G (Go– for PSL):  
Vo  
Vext  
–––––  
Vonom  
–––––  
2.5 V  
Vext 2.5 V •  
Vo Vo nom •  
Caution: To prevent damage, Vext should not exceed 20 V, nor  
be negative.  
b) Vo = 0 to Vo nom, using Rext1 between R and G (Go– for  
PSL):  
4000 Vo  
–––––––––––  
V
Rext1  
–-–onom–––––––  
Rext1  
Vo ≈  
V
o nom Vo  
Rext1 + 4000 Ω  
c) Vo = Vo nom to Vo max, using Rext2 between R and G (Go– for  
PSL):  
4000 Vo • (Vo nom – 2.5 V)  
2.5 V • (Vo – Vo nom)  
–––––––––––––––––––––––––  
Rext2  
Vo nom • 2.5 V • Rext2  
2.5 V • (Rext2 + 4000 ) Vo nom • 4000 Ω  
–––––––––––––––––––––––––––––––––  
Vo ≈  
Caution: To prevent damage, Rext2 should never be less than  
47 k.  
JM073  
Vi+  
Vo+  
R
Rext2  
4 kΩ  
Vref = 2.5 V  
+
+
Control  
logic  
Vext  
Rext1  
G
Gi–  
Go–  
Fig. 10  
Voltage adjustment via R-input  
BCD20027-G Rev AA, 18-May-2011  
Page 11 of 17  
www.power-one.com  
PSC, PSL Series Data Sheet  
Positive Switching Regulators  
®
Electromagnetic Compatibility (EMC)  
Electromagnetic Immunity  
General condition: Case not earthed.  
Table 6: Immunity type tests  
Phenomenon  
Standard  
Class  
Level  
Coupling  
mode  
Value  
applied  
Waveform  
Source  
Imped.  
Test  
procedure  
In  
Perf.  
1
2
oper. crit.  
3
Voltage surge 3  
IEC 60571-1  
i/c, +i/i  
800 Vp  
1500 Vp  
3000 Vp  
4000 Vp  
7000 Vp  
100 µs  
50 µs  
5 µs  
100 Ω  
1 pos. and 1 neg.  
surge per  
coupling mode  
yes  
B
1 µs  
100 ns  
1/50 ns  
3
4
Electrostatic  
discharge  
IEC/EN  
61000-4-2  
4 3 contact discharge 8000 Vp  
2 4  
330 Ω  
10 positive and  
10 negative  
discharges  
yes  
yes  
A 5  
to case  
4000 Vp  
Electromagnetic IEC/EN  
field  
3 3  
2 4  
antenna  
10 V/m3  
3 V/m4  
AM 80%  
1 kHz  
80 – 1000 MHz  
A
61000-4-3  
Electrical fast  
transients/burst 61000-4-4  
IEC/EN  
3
i/c, +i/–i  
2000 Vp bursts of 5/50 ns 50 Ω  
5 kHz rep. rate  
60 s positive  
60 s negative  
transients per  
coupling mode  
yes A 5, B4  
transients with  
15 ms burst  
duration and a  
300 ms period  
Surges  
IEC/EN  
61000-4-5  
33  
33  
i/c  
2000 Vp  
1000 Vp  
1.2/50 µs  
12 Ω  
2 Ω  
5 pos. and 5 neg.  
surges per  
coupling mode  
yes  
yes  
B 5  
A
+i/–i  
Conducted  
disturbances  
IEC/EN  
61000-4-6  
33  
24  
i, o, signal wires  
10 VAC3  
3 VAC4  
AM 80%  
1 kHz  
150 Ω  
0.15 – 80 MHz  
1
i = input, o = output, c = case.  
2
3
4
5
A = Normal operation, no deviation from specifications, B = Normal operation, temporary loss of function or deviation from specs possible  
Not applicable for -2 models  
Valid for -2 models  
Option L neccessary; with option C, manual reset might be necessary.  
Electromagnetic Emission  
For emission levels refer to Electrical Input Data.  
[dBµV]  
07017  
90  
80  
EN 55022 A  
EN 55022 B  
70  
60  
50  
40  
30  
20  
10  
0
Fig. 11  
Typical disturbance voltage (quasi-peak) at the input  
according to EN 55011, measured at Vi nom and Io nom  
MHz  
.
BCD20027-G Rev AA, 18-May-2011  
Page 12 of 17  
www.power-one.com  
PSC, PSL Series Data Sheet  
Positive Switching Regulators  
®
Immunity to Environmental Conditions  
Table 7: Mechanical and climatic stress  
Test Method  
Standard  
Test Conditions  
Status  
Cab  
Damp heat  
steady state  
IEC/EN 60068-2-78  
MIL-STD-810D section 507.2  
Temperature:  
Relative humidity:  
Duration:  
40±2 °C  
Regulator  
not  
operating  
93+2/-3  
%
56 days  
Ea  
Shock  
(half-sinusoidal)  
IEC/EN 60068-2-27  
MIL-STD-810D section 516.3  
Acceleration amplitude:  
Bump duration:  
50 gn = 490 m/s2  
11 ms  
Regulator  
operating  
Number of bumps:  
18 (3 each direction)  
Eb  
Bump  
(half-sinusoidal)  
IEC/EN 60068-2-29  
MIL-STD-810D section 516.3  
Acceleration amplitude:  
Bump duration:  
25 gn = 245 m/s2  
11 ms  
Regulator  
operating  
Number of bumps:  
6000 (1000 each direction)  
Fc  
Vibration  
(sinusoidal)  
IEC/EN 60068-2-6  
MIL-STD-810D section 514.3  
Acceleration amplitude:  
0.35 mm (10 – 60 Hz)  
5 gn = 49 m/s2 (60 – 2000 Hz)  
10 – 2000 Hz  
Regulator  
operating  
Frequency (1 Oct/min):  
Test duration:  
7.5 h (2.5 h each axis)  
Fda  
Kb  
Random vibration  
wide band  
Reproducibility  
high  
IEC/EN 60068-2-35  
DIN 40046 part 23  
Acceleration spectral density: 0.05 g2/Hz  
Regulator  
operating  
Frequency band:  
Acceleration magnitude:  
Test duration:  
20 – 500 Hz  
4.9 gn rms  
3 h (1 h each axis)  
Salt mist, cyclic  
(sodium chloride  
NaCl solution)  
IEC/EN 60068-2-52  
Concentration:  
Duration:  
Storage:  
Storage duration:  
Number of cycles:  
5% (30 °C)  
Regulator  
not  
operating  
2 h per cycle  
40 °C, 93% rel. humidity  
22 h per cycle  
3
Temperatures  
Table 8: Temperature specifications, valid for an air pressure of 800 - 1200 hPa (800 - 1200 mbar)  
Temperature  
-2  
-7  
-9 (Option)  
min max  
Characteristics  
Conditions  
min  
–10  
–10  
–25  
max  
50  
min  
–25  
–25  
–40  
max  
71  
Unit  
TA  
TC  
TS  
Ambient temperature 1  
Regulator  
operating  
–40  
–40  
–55  
71  
95  
°C  
Case temperature  
Storage temperature 1  
80  
95  
Non operational  
100  
100  
100  
1
See Thermal Considerations and Overtemperature Protection.  
Reliability  
Table 9: Typical MTBF and device hours  
1
MTBF  
Ground Benign  
Ground Fixed  
Ground Mobile  
TC = 50 °C  
Device Hours  
MTBF acc. to MIL-HDBK-217F  
TC = 40 °C  
TC = 40 °C  
TC = 70 °C  
660 000 h  
143 000 h  
81 000 h  
68 000 h  
2 800 000 h  
1
Statistical values, based on an average of 4300 working hours per year and in general field use  
BCD20027-G Rev AA, 18-May-2011  
Page 13 of 17  
www.power-one.com  
PSC, PSL Series Data Sheet  
Positive Switching Regulators  
®
Mechanical Data  
Yellow LED output  
voltage indicator  
Potentiometer  
(option D)  
Potentiometer  
(option P)  
PSC models  
09023a  
European  
Projection  
Vt  
Vo  
Dimensions in mm.  
Gi–  
D
G
Go– Vo+  
Vi+  
Vo  
R
i
1
151  
Distance between M4 mounting screws  
144  
0.5  
5
Measuring point  
of case temperature TC  
Fig. 12  
Case C03, weight 440 g  
Aluminium, black finish  
and self cooling  
11.3  
18.5  
1
12.5  
40  
7.5 (14)  
10 7.5 10  
7.5  
27.5 7.5  
PSL models  
The regulators are designed to be inserted into a DIN-rack  
according to IEC 60297-3. Dimensions in mm.  
168.5  
M2.5  
2 TE  
17.4 10.9  
159.4  
127  
0.5  
4.9  
6 TE  
20  
Green LED  
09027a  
Potentio-  
meter (opt. P)  
2
min. 5  
ø5.2  
ø3  
Threads M3; 4 mm deep  
(for mounting screws)  
0.9  
32  
1.5  
0.5  
173.7  
11  
6.4  
(19.1)  
20.32  
Mounting plane of  
connector H11  
4 TE  
Measuring point of  
case temperature TC  
Potentiometer (option D)  
Fig. 13  
Case L04, weight 550 g  
Aluminium, fully enclosed, black finish EP  
powder-coated, and self cooling  
BCD20027-G Rev AA, 18-May-2011  
Page 14 of 17  
www.power-one.com  
PSC, PSL Series Data Sheet  
Positive Switching Regulators  
®
Standards and Approvals  
Safety and Installation Instructions  
All switching regulators are class-I equipment and have been  
approved according to UL 60950, CSA 60950, and IEC/EN  
60950-1 2nd Ed.  
Pin Allocation  
The pins of PSC models are printed onto the case of the  
regulator.  
The regulators have been evaluated for:  
• Building in  
The pin allocation of PSL models is shown in the table below:  
• The use in a pollution degree 2 environment  
Table 10: H11 connector pin allocation (PSL models)  
• Connecting the input to a secondary circuit, which is subject  
to a maximum transient rating of 1500 V.  
Electrical Determination  
Type H11  
Pin No.  
Design.  
The switching regulators are subject to manufacturing  
surveillance in accordance with the above mentioned  
standards and with ISO 9001:2000.  
R-input (or inhibit input) 1  
2
5
R (i)  
D
Undervoltage monitor (Option D)  
Output voltage (negative)  
Output voltage (negative)  
Output voltage(positive)  
Output voltage (positive)  
8
Go–  
Go–  
Vo+  
Vo+  
Isolation  
11  
14  
17  
The resistance of the protective earth connection (max. 0.1 ) is  
tested only for PSL models.  
PSC models: Electric strength test voltage between input  
connected with output against case: 2200 VDC, 1 s (for some  
PSC models only with version V103 or higher).  
Input voltage (negative)  
Input voltage (negative)  
Input voltage (positive)  
Input voltage (positive)  
Protective ground (leading pin)  
20  
23  
26  
29  
32  
Gi–  
Gi–  
Vi+  
Vi+  
PSL models: The electric strength between the input, intercon-  
nected with the output, and the case is tested with 500 VDC (all  
-2 models), 750 VDC (models with Vi max = 80 V), or 1500 VDC  
(models with Vi max = 144) during 1 s.  
1
R-input is used for the inhibit function. Consequently, option R  
and i exclude each other.  
These tests are performed in the factory as routine test in  
accordance with EN 50116 and IEC/EN 60950. The electric  
strength test should not be repeated by the customer.  
Installation Instruction  
Railway Application  
Installation must strictly follow the national safety regulations  
in compliance with the enclosure, mounting, creepage,  
clearance, casualty, markings, and segregation requirements  
of the end-use application.  
The regulators have been developed observing the railway  
standards EN 50155 and EN 50121. All boards are coated with  
a protective lacquer.  
Check for hazardous voltages before connecting.  
Connections of PSC models can be made using fast-on or  
soldering technique. PSL models should be plugged into a  
DIN-rack  
The input and the output circuit are not separated, i.e., the  
negative path is internally interconnected.  
The regulators should be connected to a secondary circuit.  
Do not open the regulator !  
Ensure that a unit failure (e.g., by an internal short-circuit)  
does not result in a hazardous condition.  
Cleaning Agents  
In order to avoid possible damage, any penetration of  
cleaning fluids must be prevented, since the power supplies  
are not hermetically sealed.  
Protection Degree  
The protection degree is IP 30 (IP 20, if equipped with option  
P, D, or D1). It applies only, if the regulator is plugged-in or the  
matching female connector is properly attached.  
BCD20027-G Rev AA, 18-May-2011  
Page 15 of 17  
www.power-one.com  
PSC, PSL Series Data Sheet  
Positive Switching Regulators  
®
The switching characteristics of the option D output are shown  
in fig. Definition of Vt and VH.  
Description of Options  
-9 Extended Temperature Range  
The voltage Vt can be externally adjusted by  
a trim  
potentiometer. The hysteresis VH of Vt is <2%. Pin D stays low  
for a minimum time tlow min, in order to prevent any oscillation. Vt  
can be set to a value between Vi min and Vi max. Note that the  
JFET becomes conductive, when VD exceeds approx. 7 V.  
This option defines an extended temperature range as  
specified in table 8.  
P
Potentiometer  
11025  
Note: Option P is not recommended, if several regulators are  
operated in parallel connection.  
10 kΩ  
ID  
Option P excludes R function; the R-input (pin 16) should be  
left open-circuit. The output voltage Vo can be adjusted in the  
D
8.2 V  
Go –  
Vi +  
+5 V  
range 90 – 110% of Vo nom  
.
JFET  
Vt  
VD  
100 pF  
However, the minimum differential voltage Vi o min between  
input and output specified in Electrical Input Data should be  
observed.  
Gi –  
L
Input Filter  
Fig. 14  
Option L is recommended to reduce superimposed inter-  
ference voltages and to prevent oscillations, if input lines  
exceed the length of approx. 5 m in total. The fundamental  
wave (approx. 120 kHz) of the reduced interference voltage  
between Vi+ and Gi– has, with an input line inductance of  
5 µH, a maximum magnitude of 4 mVAC.  
Test circuit with definition of voltage VD and current ID  
VH  
VD  
VD high  
11026  
The input impedance of the switching regulator at 120 kHz is  
about 3.5 . The harmonics are small in comparison with the  
fundamental wave.  
With option L, the maximum permissible additionally  
superimposed ripple vi of the input voltage (rectifier mode) at  
a specified input frequency fi has the following values:  
VD low  
Vi  
Vt  
Fig. 15  
Definition of Vt and VH  
vi max = 10 Vpp at 100 Hz or Vpp = 1000 Hz/fi • 1V  
C
Thyristor Crowbar  
Table 12: Data of option D  
Option C protects the load against power supply malfunction.  
It is not designed to sink external currents. A fixed-value  
monitoring circuit checks the output voltage Vo. When the  
trigger voltage Vo c is reached, the thyristor crowbar triggers  
and disables the output. It may be deactivated by removal of  
the input voltage. In case of a defect switching transistor, the  
internal fuse prevents excessive current.  
Characteristics  
Conditions  
PSC/PSL  
min typ max  
0.8  
Unit  
VD low Low impedance Vi < Vt, ID 2.5mA  
V
VD high Highimpedance Vi > Vt + VH,  
ID > 25 mA  
4.75  
tlow min Min.durat. VDlow  
30  
1
ms  
ms  
mA  
Note: The crowbar can be reset by removal of the input voltage  
only. The inhibit signal cannot deactivate the thyristor.  
t D f  
ID  
Response toVDlow  
Current through D  
20  
D or D1 Input/Output Undervoltage Monitor  
Note: Output instead of input undervoltage monitor is  
available on request (Option D1).  
K
Connector Coding Strip  
For PSL models only.  
Terminal D and Go– are connected to a normally conducting  
field effect transistor (JFET). A 0.5 W Zener diode protects  
against overvoltages.  
G
RoHS Compliance  
Models with G are RoHS-compliant for all six substances.  
Table 11: Crowbar trigger levels  
Characteristics  
Conditions  
Vo = 5.1 V  
Vo = 12 V  
Vo = 15 V  
Vo = 24 V  
Vo = 36 V  
Unit  
min typ max min typ max min typ max min typ max min typ max  
Vo c Trigger voltage TC min TC max 5.8  
Vi min Vi max  
6.8 13.5  
1.5  
16 16.5  
1.5  
19  
27  
31  
40  
45  
V
ts  
Delay time  
1.5  
1.5  
1.5  
µs  
Io = 0 – Io nom  
BCD20027-G Rev AA, 18-May-2011  
Page 16 of 17  
www.power-one.com  
PSC, PSL Series Data Sheet  
Positive Switching Regulators  
®
Accessories  
European  
Projection  
A variety of electrical and mechanical accessories are  
available including:  
PCB-tags and isolation pads for easy and safe PCB-  
mounting.  
30  
09125  
Ring core chockes for ripple and interference reduction.  
Battery sensor [S-KSMH...] for using the regulator as  
battery charger. Different cell characteristics can be  
selected.  
l
65  
adhesive tape  
l: 2 m standard length  
other cable lengths on request  
Accessories suitable for PSL models only:  
Various mating H11 connectors STV-H11-xxx including  
screw, solder, fast-on, or press-fit terminals  
Battery temperature sensor  
Code key system for connector coding CODIERKEIL(5X)  
Various front panels for 19" racks with 3U heigth, Schroff or  
Intermas  
For additional accessory product information, see the  
accessory data sheets listed with each product series  
or individual model listing at www.power-one.com.  
H11 female connector with  
screw terminals and code  
key system  
Different front  
panels  
Different filters  
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,  
equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional  
president of Power-One, Inc.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on  
the date manufactured. Specifications are subject to change without notice.  
BCD20027-G Rev AA, 18-May-2011  
Page 17 of 17  
www.power-one.com  

相关型号:

PSL156-9RCDA

DC-DC Regulated Power Supply Module, 1 Output, METAL, CASE L04, MODULE
BEL

PSL156-9RG

Positive Switching Regulators
BEL

PSL158-7I

DC-DC Regulated Power Supply Module
BEL

PSL158-7LIPCD1A

DC-DC Regulated Power Supply Module, 1 Output, METAL, CASE L04, MODULE
BEL

PSL158-7LIPCDA

DC-DC Regulated Power Supply Module, 1 Output, METAL, CASE L04, MODULE
BEL

PSL158-7LIPD1A

DC-DC Regulated Power Supply Module, 1 Output, METAL, CASE L04, MODULE
BEL

PSL158-7LIPDA

DC-DC Regulated Power Supply Module, 1 Output, METAL, CASE L04, MODULE
BEL

PSL158-7LIRCDA

DC-DC Regulated Power Supply Module, 1 Output, METAL, CASE L04, MODULE
BEL

PSL158-7LIRPCDA

DC-DC Regulated Power Supply Module, 1 Output, METAL, CASE L04, MODULE
BEL

PSL158-7LRCD1A

DC-DC Regulated Power Supply Module, 1 Output, METAL, CASE L04, MODULE
BEL

PSL158-7LRD1A

DC-DC Regulated Power Supply Module, 1 Output, METAL, CASE L04, MODULE
BEL

PSL158-7LRDA

DC-DC Regulated Power Supply Module, 1 Output, METAL, CASE L04, MODULE
BEL