QES036ZB-A-NT1V [BEL]
1-OUTPUT 66W DC-DC REG PWR SUPPLY MODULE;型号: | QES036ZB-A-NT1V |
厂家: | BEL FUSE INC. |
描述: | 1-OUTPUT 66W DC-DC REG PWR SUPPLY MODULE 局域网 输出元件 |
文件: | 总3页 (文件大小:349K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
QES SERIES
66 WATT
Powering Communications and Technology
DESCRIPTION
QES single output DC/DC converters provide up to 66
Watts of output power in an industry standard, quarter-
brick package. The QES converters feature open-frame
packaging, along with planar magnetics and a high
efficiency topology to provide maximum useable power
with minimal thermal constraints. The QES is suited to
telecom, networking, and industrial applications, and is
fully compatible with production board washing processes.
Efficiency vs. Load (48V Input)
FEATURES
95
90
85
80
75
70
• Industry Standard
• Wide Range Input
Voltage
Package
• 100°C Case Operation • 1500V Isolation
• Optional Trim and
Enable
• Short Circuit Protection
OES021ZC-A
OES025ZD-A
OES033ZE-A
OES040ZG-A
65
60
55
50
45
40
TECHNICAL SPECIFICATIONS
1
2
3
4
5
6
7
8
9
10
X10 = LOAD %
Input
Voltage Range
General
24 VDC Nominal
18 - 36 VDC
36 - 75 VDC
Shunt Diode
48 VDC Nominal
Turn-On Time
Remote Shutdown
30 ms
Input Reverse Input Current
Positive or Negative Logic
Remote Shutdown Reference
Switching Frequency
Isolation
V
Negative
300 kHz
in
Output
Input - Output
1500 VDC
1050 VDC
1050 VDC
±0.02%/°C
Input - Case
Output - Case
Setpoint Accuracy
±1%
Line Regulation V Min. - V Max., I
Rated
0.2% V
0.5% V
0.5 VDC
in
in
Min. - I
out
Max., V Nom.
out
out
Temperature Coefficient
Case Temperature
Operating Range
Load Regulation I
Remote Sense Headroom
Minimum Output Current
out
out
in
-40 To +100°C
-40 To +125°C
105 to 115°C
5 g, 10 - 55 Hz
2.5 X
Storage Range
10 %, I
Rated
out
Thermal Shutdown Range
Vibration, 3 Axes, 5 Min Each
Dynamic Regulation, Loadstep 25% I
Pk Deviation
out
4% V
†
out
MTBF (Bellcore TR-NWT-000332)
6
Settling Time
Voltage Trim Range
Short Circuit And Overcurrent Protection
Short Circuit Current Limit
Current Limit Threshold Range, % of I
OVP Trip Range
500 mS
±10%
Shutdown
200% I
10 hrs
Safety
Weight (Approx.)
UL, cUL, TUV
1.7 oz
out
110 - 140%
Notes
Rated
115 - 140% V
70 - 90% V
out
Nom.
Nom.
Latching
out
out
†
MTBF predictions may vary slightly from model to model.
UVP Trip Range
OVP/UVP Type
Specifications typically at 25°C, normal line, and full load,
unlessotherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully
compatible with commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model.
Please consult factory for specific model information.
Units are water-washable and fully compatible with commercial
spray or immersion post wave-solder washing equipment.
1
QES SERIES
66 WATT
Powering Communications and Technology
MODELS - (See the last page of Section for options.)
Selection Chart
Vin
(Volts)
Vin Range
(Volts)
Iin Max.*
(Amps)
Vout
(Volts)
Iout Rated
(Amps)
Ripple & Noise
Pk-Pk (mV)
Efficiency
Typ. **
Model
QES050YE-A
QES066YE-A
QES036ZB-A
QES038ZD-A
QES050ZD-A
QES050ZE-A
QES066ZE-A
24
24
48
48
48
48
48
18 - 36
18 - 36
36 - 75
36 - 75
36 - 75
36 - 75
36 - 75
3.3
4.4
1.4
1.4
1.8
1.6
2.2
3.3
3.3
1.8
2.5
2.5
3.3
3.3
15
20
20
15
20
15
20
100
100
75
100
100
100
100
85%
85%
76%
85%
83%
86%
86%
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
-0.14"
(-3.6mm)
2.010"
(51.1mm)
MOUNTING INSERTS
M3X0.5 THROUGH 2PL
0
MECHANICAL DRAWING
0.895"(22.7mm)
0.600"(15.2mm)
4
5
6
7
8
1
2
0.450"(11.4mm)
0.300"(7.6mm)
0.150"(3.8mm)
0
1.45"
(36.8mm)
BOTTOM VIEW
3
-0.295"(-7.5mm)
-0.425"(-10.8mm)
2.000"
(50.8mm)
-0.010"
(-0.3mm)
2.28"
(57.9mm)
DIA 0.040"
(1.0mm)
DIA 0.062"
(1.6mm)
0.18"(4.6mm)
0.50"
(12.7mm)
Thermal Impedance
Tolerances
Pin
Function
-V
Natural Convection 10.1 °C/W
Inches:
(Millimeters)
1
.XX ± 0.020
.XXX ± 0.010
.X ± 0.5
in
On/Off
+V
100 LFM
200 LFM
300 LFM
400 LFM
8.0 °C/W
5.4 °C/W
4.4 °C/W
3.4 °C/W
.XX ± 0.25
2
3
in
Pin:
4
-V
out
± 0.002
± 0.05
5
6
7
8
-Sense
Trim
(Dimensions as listed unless
otherwise specified.)
+Sense
Note:
+V
out
Thermal impedance data is
dependent on many environmental
factors. The exact thermal
performance should be validated
for specific application.
2
OPTIONS
Powering Communications and Technology
When ordering equipment options, use the following suffix information. Select the option(s) that you prefer and
add them to the model number. Example ordering options are located below the options table.
OPTIONS
Negative Logic
SUFFIX
APPLICABLE SERIES
REMARKS
N
HAS, HBD, HBS, HES, HLS, LES,
QBS, QES, QLS, TES, TQD
TTL "Low" Turns Module ON
TTL "High" Turns Module OFF
HAS, HBD, HBS, HES, HLS, QBS, QES,
QLS
Lucent Compatible Trim
Terminal Strip
T
TS
XWS, XWD, XWT
Trim
1
2
IAS, LES
Enable
IAD, IAS, LES, SMS
Trim and Enable
Current Share
3
4
Y
IAS, LES
SMS
Headerless
PIN LENGTH AND HEATSINK
OPTIONS
Encapsulated EWS, IWS, OWS
Standard Pin Length is 0.180"
(4.6mm)
0.110" (2.8mm) Pin Length
0.150" (3.8mm) Pin Length
8
9
All Units (Except SMS)
All Units (Except SMS)
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
All Units (Except DIP, HLS, HLD, QLS,
SIP, SM TLD, and TKD Packages)
0.24" (6.1mm) Horizontal Heatsink
0.24" (6.1mm) Vertical Heatsink
0.45" (11.4mm) Horizontal Heatsink
0.45" (11.4mm) Vertical Heatsink
0.95" (24.1mm) Horizontal Heatsink
0.95" (24.1mm) Vertical Heatsink
1H
1V
2H
2V
3H
3V
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Example Options:
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and 0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems, equipment used
in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manu-
factured. Specifications are subject to change without notice.
3
相关型号:
©2020 ICPDF网 联系我们和版权申明