QHS12ZH-NT9 [BEL]

1-OUTPUT DC-DC REG PWR SUPPLY MODULE;
QHS12ZH-NT9
型号: QHS12ZH-NT9
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

1-OUTPUT DC-DC REG PWR SUPPLY MODULE

输出元件
文件: 总10页 (文件大小:378K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
QHS DC-DC Series Data Sheet  
Features  
Low profile – 12.7 mm height  
Input/output isolation: 1500VDC, Basic  
insulation  
High efficiency - up to 92% at full load  
Start-up into high capacitive load  
Low conducted and radiated EMI  
Output overcurrent protection  
Output overvoltage protection  
Back drive protection  
Overtemperature protection  
Remote sense  
Applications  
Remote on/off (primary referenced), positive or  
negative logic  
Distributed power architectures  
Telecommunications equipment  
LAN/WAN  
Output voltage trim adjust  
UL1950 recognition, CSA 22.2 No. 950-95  
certification, TUV IEC950  
Data processing  
Description  
The QHS is a series of high efficiency, high-density, single output dc-dc converters for onboard conversion of  
standard telecom and datacom input voltages into isolated low voltage outputs in a through-hole mounting  
package. The two-board construction provides a cool environment for control components and the integrated  
metallic substrate PCB provides superior thermal management for power components resulting in enhanced  
product reliability. A heat sink can be conveniently and effectively attached to the IMS base plate for operations in  
elevated ambient conditions or where airflow is minimal.  
Model Selection  
Model  
Input  
Voltage  
VDC  
Input  
Current, Max  
ADC  
Output  
Voltage  
Vout,  
Output Rated  
Current  
I rated,  
Output  
Ripple/Noise,  
mV p-p  
Typical  
Efficiency @  
I rated,  
%
VDC  
ADC  
QHS12ZH  
QHS25ZG  
QHS40ZE  
QHS40ZD  
QHS40ZB  
QHS50ZA  
QHS50ZY  
36-75  
36-75  
36-75  
36-75  
36-75  
36-75  
36-75  
4.5  
4.3  
4.5  
3.3  
2.5  
2.7  
2.3  
12.0  
5.0  
3.3  
2.5  
1.8  
1.5  
1.2  
12  
25  
40  
40  
40  
50  
50  
150  
150  
150  
100  
100  
100  
100  
91  
92  
89  
88  
85  
79  
76  
REV. JUN 04, 2004  
Page 1 of 10  
QHS DC-DC Series Data Sheet  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely effect long-  
term reliability and cause permanent damage to the converter.  
Table 1. Absolute Maximum Ratings  
Parameter  
Input voltage  
Conditions/Description  
Continuous  
Min  
Max  
75  
80  
Units  
VDC  
VDC  
Transient  
Operating Temperature  
Storage Temperature  
ON/OFF Control Voltage  
Base Plate Temperature  
-40  
-40  
100  
°C  
°C  
VDC  
125  
20  
Referenced to -Vin  
Environmental and Mechanical Specifications  
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.  
Table 2. Environmental and Mechanical Specifications  
Parameter  
Shock  
Conditions/Description  
Halfsine wave, 3 axes  
Min  
50  
1
Nom  
Max  
Units  
g
Sinusoidal Vibration  
Weight  
GR-63-Core, Section 5.4.2  
g
1.2/35  
Yes  
Oz/g  
Water Washing  
MTBF  
Standard process  
Per Bellcore TR-NWT-000332  
1,980  
kHrs  
REV. JUN 04, 2004  
Page 2 of 10  
QHS DC-DC Series Data Sheet  
Isolation Specifications  
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.  
Table 3. Isolation Specifications  
Parameter  
Conditions/Description  
Min  
Nom  
Max  
Units  
Insulation Safety Rating  
Isolation Voltage  
Basic  
Input to output, input to base plate  
Output to base plate  
1500  
500  
10  
VDC  
VDC  
MOhm  
pF  
Isolation Voltage  
Isolation Resistance  
Isolation Capacitance  
1000  
Input Specifications  
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.  
Table 4. Input Specifications  
Parameter  
Conditions/Description  
Min  
Nom  
Max  
Units  
Input Voltage  
Continuous  
36  
48  
75  
VDC  
Turn-On Input Voltage  
Turn-Off Input Voltage  
Input over voltage protection  
Turn-On Time  
Ramping Up  
Ramping Down  
34  
33  
VDC  
VDC  
VDC  
ms  
Ramping up  
76  
84  
5
To Output Regulation Band  
100% Resistive Load  
Full Load, 12uH source inductance  
Input Reflected Ripple Current  
Inrush Transient  
60  
mA p-p  
A2s  
Vin=Vin.max  
0.1  
REV. JUN 04, 2004  
Page 3 of 10  
QHS DC-DC Series Data Sheet  
Output Specifications  
All specifications apply over specified input voltage, output load and temperature range, unless otherwise noted.  
Table 5. Output Specifications  
Parameter  
Conditions/Description  
Min  
Nom  
Max  
Units  
Output Voltage Setpoint Accuracy  
Vin=Vin.nom, Full Load  
1.8V  
2.5V  
-1.67  
-2.00  
-1.5  
-2.0  
0
1.67  
2.00  
1.5  
%Vout  
%Vout  
%Vout  
%Vout  
%Irated  
%Vout  
%Vout  
%Vout  
3.3V  
12V  
2.0  
Output Current*  
Line Regulation  
Load Regulation  
Total output voltage regulation  
See selection chart for Irated  
Vin.min to Vin.max, Irated  
100  
0.2  
Vin=Vin.nom, 10% to 100%Irated  
0.75  
3
Over all input voltage, load, and  
temperature conditions  
-3  
Remote Sense Headroom***  
Dynamic Regulation  
Peak Deviation  
10%  
%Vout  
50-75% load step change  
5
%Vout  
µs  
Settling Time  
to 1% error band  
Irated, Nom Vin  
12V  
250  
Admissible Load Capacitance  
27,000  
8,000  
150  
µF  
µF  
%Irated  
kHz  
Output Current Limit Threshold**  
Switching Frequency  
Vout0.97Vout.nom  
2.5V and 1.8V  
3.3V  
110  
300  
450  
400  
kHz  
12V  
kHz  
Overvoltage Protection,  
Non Latching  
Over all input voltage and load  
conditions  
120  
90  
140  
110  
%Vout  
Trim Range  
Irated, Vin=Vnom  
%Vout  
* At Iout<Iout.min, the output may contain low frequency component that exceeds ripple specifications.  
** Overcurrent protection is non-latching with auto recovery.  
*** Vout can be increased up to 10% via the sense leads or up to 10% via the trim function, however total output voltage trim from all sources  
should not exceed 10% of Vout  
REV. JUN 04, 2004  
Page 4 of 10  
QHS DC-DC Series Data Sheet  
Feature Specifications  
All specifications apply over specified input voltage, output load and temperature range, unless otherwise noted.  
Table 6. Feature Specifications  
Parameter  
Shutdown (ON/OFF)  
Negative Logic  
Conditions/Description  
On/Off signal is low – converter is ON  
ON/OFF pin is connected to -Vin  
Min  
Nom  
Max  
Units  
Converter ON  
Source Current  
Converter OFF  
-0.5  
3.5  
1.8  
1
20  
5
VDC  
mADC  
VDC  
Open Circuit Voltage  
Positive Logic  
ON/OFF pin is floating  
On/Off signal is low–converter is OFF  
VDC  
Converter ON  
Open Circuit Voltage  
Converter OFF  
3.5  
20  
5
1.8  
1
VDC  
VDC  
VDC  
mADC  
°C  
ON/OFF pin is floating  
-0.5  
Source Current  
Overtemperature Protection  
ON/OFF pin is connected to -Vin  
Average board temperature  
105  
Characteristic Curves  
95  
90  
85  
80  
75  
70  
65  
60  
95  
90  
85  
80  
75  
70  
65  
60  
EFF.(35V)  
EFF.(48V)  
EFF.(75V)  
EFF.(36V)  
EFF.(48V)  
EFF.(75V)  
10 20 30 40 50 60 70 80 90 100  
10 20 30 40 50 60 70 80 90 100  
LOAD %  
LOAD %  
Figure 1. QHS12ZH Efficiency vs. Output Load  
Figure 3. QHS40ZD Efficiency vs. Output Load  
95  
90  
90  
85  
80  
75  
70  
65  
60  
85  
80  
75  
70  
65  
60  
55  
EFF.(36V)  
EFF.(48V)  
EFF.(75V)  
EFF.(36V)  
EFF.(48V)  
EFF.(75V)  
10 20 30 40 50 60 70 80 90 100  
LOAD %  
10 20 30 40 50 60 70 80 90 100  
LOAD %  
Figure 2. QHS40ZE Efficiency vs. Output Load  
Figure 4. QHS40ZB Efficiency vs. Output Load  
REV. JUN 04, 2004  
Page 5 of 10  
QHS DC-DC Series Data Sheet  
4
3.5  
3
5
4.5  
4
3.5  
3
2.5  
2
1.5  
1
0.5  
0
2.5  
2
1.5  
1
0.5  
0
0
10  
20  
30  
40  
50  
60  
70  
Input Voltage (V)  
0
10  
20  
30  
40  
50  
60  
70  
Input Voltage (V)  
Figure 7. QHS40ZD Input Characteristics  
Figure 5. QHS12ZH Input Characteristics  
3
2.5  
2
5
4.5  
4
3.5  
3
1.5  
1
2.5  
2
1.5  
1
0.5  
0
0.5  
0
0
10  
20  
30  
40  
50  
60  
70  
0
10  
20  
30  
40  
50  
60  
70  
Input Voltage (V)  
Input Voltage (V)  
Figure 6. QHS40ZE Input Characteristics  
Figure 8. QHS40ZB Input Characteristics  
REV. JUN 04, 2004  
Page 6 of 10  
QHS DC-DC Series Data Sheet  
control signal must not be referenced ahead of  
EMI filtering, or remotely from the unit. Optically  
coupling the information and locating the optical  
coupler directly at the module will solve any of  
these problems.  
Typical Application  
Figure 9 shows the recommended connections for the  
QHS Series converter.  
QHS40ZX  
Note:  
Fuse  
If the ON/OFF pin is not used, it can be left floating (positive  
logic), or connected to the -Vin pin (negative logic).  
+Vo  
+Vi  
+Sense  
C1  
C2 C3  
Trim  
On/Off  
-Vi  
Output Voltage Trim  
-Sense  
-Vo  
Industry Standard Trim  
The units trim up with a resistor from the TRIM pin  
to the +Sense pin and trim down with a resistor  
from the TRIM pin to the –Sense pin as shown in  
Figure 10.  
Figure 9. Typical Application of the QHS Series  
The QHS Series converters do not require any external  
components for proper operation. However, if the  
distribution of the input voltage to the converter contains  
significant inductance, the capacitor C1 may be  
required to enhance performance of the converter. A  
minimum of a 33µF electrolytic capacitor with the  
ESR<0.7is recommended for the QHS Series.  
Refer to the “Inrush Current Control Application Note”  
on www.power-one.com for suggestions on how to limit  
the magnitude of the inrush current.  
For output decoupling we recommend using a 10µF  
tantalum and a 1µF ceramic capacitors connected  
directly across the output pins of the converter. Note,  
that the capacitors do not substitute the filtering  
required by the load.  
Figure 10. QHS Series Positive Trim Schematic  
Shutdown Feature Description  
The ON/OFF pin in the QHS Series converters  
functions as a normal soft shutdown. It is referenced to  
the –Vin pin (see Figure 7). With the positive logic,  
when the ON/OFF pin is pulled low, the output is turned  
off and the unit goes into a very low input power mode.  
The equations below determine the trim resistor  
value required to achieve a V change in the  
output voltage.  
5.1Vo(100 + ∆%) 510  
Radj up =  
10.2) kΩ  
With negative logic, when the ON/OFF pin is pulled low,  
the unit is turned on.  
1.225%  
%  
An open collector switch is recommended to control the  
voltage between the ON/OFF pin and the -Vin pin of the  
converter. The ON/OFF pin is pulled up internally, so  
no external voltage source is required. The user should  
avoid connecting a resistor between the ON/OFF pin  
and the +Vin pin.  
510  
Radj down =  
10.2) kΩ  
%  
where V% is the output voltage change  
expressed in percents of the nominal output  
voltage, Vout.  
When the ON/OFF pin is used to achieve remote  
control, the user must take care to insure that the pin  
reference for the control is really the -Vin pin. The  
REV. JUN 04, 2004  
Page 7 of 10  
QHS DC-DC Series Data Sheet  
Notes:  
If the voltage source feeding the module is a  
Hazardous Voltage Secondary Circuit, the  
voltage source feeding the module must be  
provided with at least Basic insulation  
between the source to the converter and any  
1. When the output voltage is trimmed up, the output power from  
the converter must not exceed its maximum rating. The power is  
determined by measuring the output voltage on the output pins,  
and multiplying it by the output current.  
2. In order to avoid creating apparent load regulation degradation, it  
is important that the trim resistors are connected directly to the  
remote sense pins, and not to the load or to traces going to the  
load.  
hazardous voltages.  
The entire system,  
including the QHS converter, must pass a  
dielectric withstand test for Reinforced  
insulation. Design of this type of systems  
requires expert engineering and under-  
standing of the overall safety requirements  
and should be performed by qualified  
personnel.  
3. The QHS Series converters will trim down further than the 10%  
limit. In general, this is permissible. The user must confirm that  
the results are acceptable in the application.  
Safety Considerations  
The QHS Series converters feature 1500 Volt DC  
isolation from input to output. The input to output  
resistance is greater than 10MOhm. These converters  
are provided with Basic insulation between input and  
output circuits according to all IEC60950 based  
standards. Nevertheless, if the system using the  
converter needs to receive safety agency approval,  
certain rules must be followed in the design of the  
system. In particular, all of the creepage and clearance  
requirements of the end-use safety requirements must  
be observed. These documents include UL60950 -  
CSA60950-00 and EN60950, although other or  
additional requirements may be needed for specific  
applications.  
Thermal Considerations  
The QHS Series converters are designed for  
natural or forced convection cooling.  
The  
maximum allowable output current of the  
converters is determined by meeting the derating  
criteria for all components used in the converters.  
For example, the maximum semiconductor  
junction temperature is not allowed to exceed  
120°C to ensure reliable long-term operation of  
the converters.  
Contact Power-One for the  
complete list of the derating criteria.  
The graphs in Figures 11-14 show the maximum  
output current of the QHS Series converters at  
different ambient temperatures under both natural  
and forced (longitudinal airflow direction, from pin  
1 to pin 3) convection.  
The QHS Series converters have no internal fuse. The  
external fuse must be provided to protect the system  
from catastrophic failure as shown in Figure 7. The  
user can select a fuse based upon the highest inrush  
transient at the maximum input voltage and the  
maximum input current of the converter, which occurs  
at the minimum input voltage. Both input traces and the  
chassis ground trace (if applicable) must be capable of  
conducting a current of 1.5 times the value of the fuse  
without opening. The fuse must not be placed in the  
grounded input line, if any.  
For example, from Figure 11, the QHS40ZE  
operating at 55°C can deliver up to 18A reliably  
with 100LFM forced air, while up to 25A reliably  
with 400LFM forced air.  
12  
10  
8
In order for the output of the QHS Series converter to  
be considered as SELV (Safety Extra Low Voltage) or  
TNV-1, according to all IEC60950 based standards, one  
of the following requirements must be met in the system  
design:  
6
0
4
100LFM  
200LFM  
2
If the voltage source feeding the module is SELV or  
TNV-2, the output of the converter may be  
grounded or ungrounded.  
300LFM  
400LFM  
0
25 30 35 40 45 50 55 60 65 70 75 80 85  
Ambient Temperature (C)  
If the voltage source feeding the module is ELV, the  
output of the converter may be considered SELV  
only if the output is grounded per the requirements  
of the standard.  
Figure 11. QHS12ZH (12V) Derating Curves  
REV. JUN 04, 2004  
Page 8 of 10  
QHS DC-DC Series Data Sheet  
40  
35  
30  
25  
20  
15  
10  
5
40  
35  
30  
25  
20  
0
15  
10  
5
0
100LFM  
200LFM  
300LFM  
400LFM  
100LFM  
200LFM  
300LFM  
400LFM  
0
0
25 30 35 40 45 50 55 60 65 70 75 80 85  
Ambient Temperature (C)  
25 30 35 40 45 50 55 60 65 70 75 80 85  
Ambient Temperature (C)  
Figure 12. QHS40ZE (3.3V) Derating Curves  
Figure 14. QHS40ZB (1.8V) Derating Curves  
40  
35  
30  
25  
20  
15  
10  
5
0
100LFM  
200LFM  
300LFM  
400LFM  
0
25 30 35 40 45 50 55 60 65 70 75 80 85  
Ambient Temperature (C)  
Figure 13. QHS40ZD (2.5V) Derating Curves  
REV. JUN 04, 2004  
Page 9 of 10  
QHS DC-DC Series Data Sheet  
Mechanical Drawing  
Figure 15. Mechanical Drawing  
Table 7. Pinout/Functions  
Pin  
1
Function  
-Vin  
2
3
On/off  
+Vin  
Mechanical Tolerances  
Inches  
4
5
6
7
-Vout  
-Sense  
Trim  
+Sense  
+Vout  
Millimeters  
X.X 0.5  
X.XX 0.25  
X.XX  
0.020  
X.XXX 0.010  
8
Pin  
0.002  
0.05  
Ordering:  
Table 8. Ordering Information  
Suffixes to add to part number  
Options  
Remote ON/OFF  
Positive- Standard, no suffix required  
Negative- Add “NT” suffix  
0.18”- Standard, no suffix required  
0.11”- Add “8” suffix  
Pin Length  
0.15”- Add “9” suffix  
Notes:  
Consult factory for the complete list of available options.  
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,  
equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional  
president of Power-One, Inc.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on  
the date manufactured. Specifications are subject to change without notice.  
REV. JUN 04, 2004  
Page 10 of 10  

相关型号:

QHS12ZH8

DC-DC Regulated Power Supply Module, 1 Output, 14W, Hybrid, PACKAGE-8
BEL

QHS12ZH9

DC-DC Regulated Power Supply Module, 1 Output, 14W, Hybrid, PACKAGE-8
BEL

QHS12ZHN

DC-DC Regulated Power Supply Module, 1 Output, 14W, Hybrid, PACKAGE-8
BEL

QHS12ZHN-T

DC-DC Regulated Power Supply Module, 1 Output, 14W, Hybrid, PACKAGE-8
BEL

QHS12ZHN-T8

DC-DC Regulated Power Supply Module, 1 Output, 14W, Hybrid, PACKAGE-8
BEL

QHS12ZHN-T9

DC-DC Regulated Power Supply Module, 1 Output, 14W, Hybrid, PACKAGE-8
BEL

QHS12ZHN9

DC-DC Regulated Power Supply Module, 1 Output, 14W, Hybrid, PACKAGE-8
BEL

QHS12ZHNT-7

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, QUARTER BRICK PACKAGE-8
BEL

QHS12ZHNT-8

1-OUTPUT DC-DC REG PWR SUPPLY MODULE, QUARTER BRICK PACKAGE-8
BEL

QHS25ZG

DC-DC Regulated Power Supply Module, 1 Output, 12W, Hybrid, PACKAGE-8
BEL

QHS25ZG-7

DC-DC Regulated Power Supply Module, 1 Output, Hybrid, QUARTER BRICK PACKAGE-8
BEL

QHS25ZG-8

1-OUTPUT DC-DC REG PWR SUPPLY MODULE, QUARTER BRICK PACKAGE-8
BEL