QKS48T21120-PCA0 [BEL]

DC-DC Regulated Power Supply Module, 1 Output, 252W, Hybrid, PACKAGE-5;
QKS48T21120-PCA0
型号: QKS48T21120-PCA0
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

DC-DC Regulated Power Supply Module, 1 Output, 252W, Hybrid, PACKAGE-5

文件: 总9页 (文件大小:271K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
QKS48T21120 DC-DC Bus Converter Data Sheet  
Quarter-Brick with 48VDC Input; 12VDC @ 21A Output  
Benefits  
Simplifies power system design; reduces design  
time and technical risk  
Compatible with all (12 Vin nom.) POLs available in  
the market  
Features  
RoHS lead free solder and lead solder exempted  
products are available  
Loosely regulated output  
High output power of 252 W  
Efficiency to 94%  
Wide-input voltage range from 36 to 75 VDC  
100V/100ms input voltage surge withstand  
Input-to-output isolation: 1500 VDC  
Basic insulation  
Applications  
Power systems utilizing Intermediate Bus  
Architecture  
Networking equipment  
Data/voice processing  
Wireless communications  
Computing  
Backdrive protection  
Start-up into pre-biased load  
Output overcurrent protection  
Output overvoltage protection  
Overtemperature protection  
ATCA  
Remote on/off (primary referenced), positive or  
negative logic option  
Designed to comply with NEBS GR-1089 and GR-63  
Safety: UL60950-1, CSA C22.2 No. 60950-1,TUV  
EN60950-1, IEC60950-1  
Description  
The QKS is a high density and highly efficient, isolated DC-DC converter that operates over an input voltage range  
of 36 VDC to 75VDC. It provides a 12 VDC nominal, loosely-regulated output voltage at up to 21 ADC of current.  
The converter is an ideal choice for building a complete power system utilizing the Intermediate Bus Architecture  
(IBA). The thermally-optimized construction of the QKS allows the converter to provide high output current over a  
wide operating temperature range while maintaining a safe guardband for component electrical and thermal  
ratings. The QKS employs 100% surface-mount components for consistency and reliability in the production  
process.  
Model Selection  
Input  
Voltage  
VDC  
Input  
Current,  
Max ADC  
Output  
Voltage  
VDC  
Output Rated  
Current I rated  
ADC  
Output  
Ripple/Noise,  
mV p-p  
Typical  
Eff.@ 75%  
I rated, 40C,  
48Vi  
Model  
%
QKS48T21120  
35-75  
7.5  
21  
94  
12 (NOM.)  
120 (NOM.)  
Model numbers highlighted in yellow or shaded are not recommended for new designs.  
The QKS48T21120 is not recommended for new designs. Please refer to the  
QME48T20120 data sheet for a similar product.  
.
MCD10089 Rev. 1.1, 8-Oct-08  
Page 1 of 9  
www.power-one.com  
QKS48T21120 DC-DC Bus Converter Data Sheet  
Quarter-Brick with 48VDC Input; 12VDC @ 21A Output  
Absolute Maximum Ratings  
Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely effect long-  
term reliability, and cause permanent damage to the converter.  
Parameter  
Conditions/Description  
Continuous  
Min  
Max  
75  
Units  
VDC  
VDC  
°C  
Input Voltage  
Transient, 100 ms  
PC Board Temperature  
100  
100  
125  
Operating Temperature  
Storage Temperature  
-40  
-40  
°C  
Environmental and Mechanical Specifications  
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.  
Parameter  
Operating Humidity  
Storage Humidity  
Shock  
Conditions/Description  
Relative Humidity, Non-cond.  
Relative Humidity, Non-cond.  
(Half-sinewave, 6ms), 3 axes  
GR-63-CORE, Section 5.4.2  
Min  
Nom  
Max  
95  
Units  
%
95  
%
50  
1
g
Sinusoidal Vibration  
Weight  
g
1.2/35  
Yes  
1.8  
Oz/g  
Water Washing  
MTBF  
Standard process  
Per Bellcore TR-NWT-000332  
MHrs  
Isolation Specifications  
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.  
Parameter  
Conditions/Description  
Min  
Nom  
Max  
Units  
Insulation Safety Rating  
Isolation Voltage  
Basic  
Input to Output  
1500  
10  
VDC  
MOhm  
pF  
Isolation Resistance  
Isolation Capacitance  
1000  
Input Specifications  
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.  
Parameter  
Conditions/Description  
Min  
Nom  
Max  
Units  
Input Voltage  
Continuous  
36  
48  
75  
VDC  
Input Undervoltage Lockout  
Turn-on Voltage Threshold  
Turn-off Voltage Threshold  
Hysteresis  
33.5  
32  
1.5  
34.5  
33  
35.5  
34  
Vin  
V
Power up Turn-on delay time  
(Time from VIN @ UVLO to Vo @  
10% of Vo nominal)  
Enable Turn-on delay time  
(Time from Venable @ 0.8V to Vo  
@ 10% of Vo nominal)  
All  
All  
0.5  
0.5  
30  
11  
ms  
ms  
MCD10089 Rev. 1.1, 8-Oct-08  
Page 2 of 9  
www.power-one.com  
QKS48T21120 DC-DC Bus Converter Data Sheet  
Quarter-Brick with 48VDC Input; 12VDC @ 21A Output  
Parameter  
Conditions/Description  
Min  
Nom  
Max  
Units  
Output Rise Time at Turn-on  
(Time from Vo @ 10% Vo  
nominal to Vo @ 90% of Vo  
nominal)  
All  
0.5  
30  
ms  
w/ Load = resistor + 330 µF  
capacitor  
Turn-on Output Overshoot  
Input Reflected Ripple Current  
Vo  
13.2  
200  
VDC  
mA p-p  
Full Load, 12μH source inductance  
-
-
Inrush Transient  
i2t  
2
A2s  
Output Specifications  
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.  
Parameter  
Conditions/Description  
Min  
11  
0
Nom  
Max  
13  
Units  
VDC  
A
Output Voltage Set Point  
(Vin = 48V, Iout = ½ full load, 25°C)  
Output Current  
Vo  
Io  
11.5  
21  
Output Ripple  
(DC to 20MHz, 25°C)  
Output Line regulation  
(Vi=36V to 75V, Iout = full load, 25°C)  
Output Load regulation  
(lout from 0 to full load)  
Output Temperature Regulation:  
(Tcase =-40°C to +110°C)  
Transient Response  
Vo  
25  
3
70  
mVp-p  
Vo  
Vo  
Vo  
8
mV  
mV  
500  
%/°C  
± 0.03  
(50% to 75% Load Step, Io/Δt=1A/µs,  
with 220µF, ESR<0.07ohm on output  
side)  
Vo  
11  
-
-
13  
10  
V
ms  
Peak Deviation  
Settling Time (Vo, 1% of Vo)  
Admissible Load Capacitance  
Output Current Limit Threshold*  
Switching Frequency  
Irated, Nom Vin  
Io  
330  
110  
5000  
150  
μF  
%Irated  
kHz  
135  
350  
Overvoltage Protection,  
Hiccup, auto recovery  
Over all input voltage and load  
conditions  
14  
15  
VDC  
* Overcurrent protection is non-latching with auto recovery.  
MCD10089 Rev. 1.1, 8-Oct-08  
Page 3 of 9  
www.power-one.com  
QKS48T21120 DC-DC Bus Converter Data Sheet  
Quarter-Brick with 48VDC Input; 12VDC @ 21A Output  
Feature Specifications  
All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted.  
Parameter  
Min  
Nom  
Max  
Units  
Remote On/Off, Primary Side  
Positive Logic  
Off – State Voltage  
On – State Voltage  
-0.5  
2.5  
0.3  
40  
VDC  
VDC  
Negative Logic (-N option)  
Off – State Voltage  
2.5  
-0.5  
40  
0.3  
VDC  
VDC  
VDC  
On – State Voltage  
Open Circuit Voltage (internal pull up  
circuit at On/Off pin)  
Sink Current-Logic Low  
Thermal Shutdown  
(PCB temperature)  
Hysteresis (Latching Optional)  
5
0.50  
mA  
+129  
20  
+137  
°C  
* Overtemperature protection is auto recovery via hysteresis loop. Optionally, latched overtemperature protection can specified by adding “S1”  
in the special options field of the part number (see page 9).  
MCD10089 Rev. 1.1, 8-Oct-08  
Page 4 of 9  
www.power-one.com  
QKS48T21120 DC-DC Bus Converter Data Sheet  
Quarter-Brick with 48VDC Input; 12VDC @ 21A Output  
Shutdown Feature Description  
Efficiency Curve  
The ON/OFF pin in the QKS48T21120 converter  
functions as a normal soft shutdown. It is referenced  
to the –Vin pin (see Figure 2). With the positive  
logic, when the ON/OFF pin is pulled low, the output  
is turned off and the unit goes into a very low input  
power mode.  
With negative logic, when the ON/OFF pin is pulled  
low, the unit is turned on.  
An open collector switch is recommended to control  
the voltage between the ON/OFF pin and the -Vin  
pin of the converter. The ON/OFF pin is pulled up  
internally, so no external voltage source is required.  
The user should avoid connecting a resistor between  
the ON/OFF pin and the +Vin pin.  
When the ON/OFF pin is used to achieve remote  
Figure 1. QKS48T21120 Efficiency vs. Output Load  
control, the user must take care to insure that the pin  
reference for the control is really the -Vin pin. The  
control signal must not be referenced ahead of EMI  
filtering, or remotely from the unit. Optically coupling  
the information and locating the optical coupler  
directly at the module will solve any of these  
problems.  
Typical Application  
Figure 2 shows the recommended connections for  
the QKS48T21120 converter.  
Note:  
Fuse  
If the ON/OFF pin is not used, it can be left floating (positive logic),  
or connected to the -Vin pin (negative logic).  
+Vo  
+Vi  
C1  
C3  
On/Off  
-Vi  
-Vo  
Figure 2. Typical Application of QKS48T21120  
The QKS48T21120 converter does not require any  
external components for proper operation. However,  
a 100 µF low ESR input capacitor and a 330 µF  
output capacitor are recommended for optimal  
performance  
Refer to the “Inrush Current Control Application  
Note” on www.power-one.com for suggestions on  
how to limit the magnitude of the inrush current.  
MCD10089 Rev. 1.1, 8-Oct-08  
Page 5 of 9  
www.power-one.com  
QKS48T21120 DC-DC Bus Converter Data Sheet  
Quarter-Brick with 48VDC Input; 12VDC @ 21A Output  
Safety Considerations  
The QKS48T21120 converter features 1500 Volt DC  
isolation from input to output. The input-to-output  
resistance is greater than 10 M. This converter is  
provided with basic insulation between input and  
output circuits according to all IEC60950 based  
standards. Nevertheless, if the system using the  
converter needs to receive safety agency approval,  
certain rules must be followed in the design of the  
system. In particular, all of the creepage and  
clearance requirements of the end-use safety  
requirements must be observed. These documents  
include UL60950 - CSA60950-00 and EN60950,  
although other or additional requirements may be  
needed for specific applications.  
The QKS48T21120 converter has no internal fuse.  
The external fuse must be provided to protect the  
system from catastrophic failure. The fuse with a  
rating not greater than 10A is recommended. The  
user can select a lower rating fuse based upon the  
highest inrush transient at the maximum input  
voltage and the maximum input current of the  
converter, which occurs at the minimum input  
voltage. Both input traces and the chassis ground  
trace (if applicable) must be capable of conducting a  
current of 1.5 times the value of the fuse without  
opening. The fuse must not be placed in the  
grounded input line, if any.  
In order for the output of the QKS48T21120  
converter to be considered as SELV (Safety Extra  
Low Voltage) or TNV-1, according to all IEC60950  
based standards, one of the following requirements  
must be met in the system design:  
If the voltage source feeding the module is SELV  
or TNV-2, the output of the converter may be  
grounded or ungrounded.  
If the voltage source feeding the module is ELV,  
the output of the converter may be considered  
SELV only if the output is grounded per the  
requirements of the standard.  
If the voltage source feeding the module is a  
Hazardous Voltage Secondary Circuit, the  
voltage source feeding the module must be  
provided with at least Basic insulation between  
the source to the converter and any hazardous  
voltages.  
The entire system, including the  
QKS48T21120 converter, must pass a dielectric  
withstand test for Reinforced insulation. Design  
of this type of systems requires expert  
engineering and understanding of the overall  
safety requirements and should be performed by  
qualified personnel.  
MCD10089 Rev. 1.1, 8-Oct-08  
Page 6 of 9  
www.power-one.com  
QKS48T21120 DC-DC Bus Converter Data Sheet  
Quarter-Brick with 48VDC Input; 12VDC @ 21A Output  
term operation of the converter. Contact Power-One  
for a complete list of the derating criteria.  
Thermal Considerations  
The graph in figure 3 shows the maximum output  
The QKS48T21120 converter is designed for natural  
or forced-convection cooling. The maximum  
current of the QKS48T21120 converter at different  
ambient temperatures under both natural and forced  
convection.  
allowable output current of the converter is  
determined by meeting the derating criteria for all  
components used in the converter. For example, the  
maximum semiconductor junction temperature is not  
allowed to exceed 125 °C to ensure reliable long-  
For example, the QKS48T21120 operating at 70 °C  
can deliver up to 15.7A reliably with 200 LFM forced  
air.  
THERMAL DERATING CURVE  
QKS48T21120-NCA0  
Vin = 48V, Orientation : Vin- to Vin +  
Data Rev: 01  
24  
20  
16  
12  
8
4
NC (25 - 35 LFM)  
100 LFM  
40  
200 LFM  
300 LFM  
55  
400 LFM  
0
25  
70  
85  
Ambient Temperature (Deg C)  
Figure 3. QKS48T21120 Derating Curves  
MCD10089 Rev. 1.1, 8-Oct-08  
Page 7 of 9  
www.power-one.com  
QKS48T21120 DC-DC Bus Converter Data Sheet  
Quarter-Brick with 48VDC Input; 12VDC @ 21A Output  
Mechanical Drawing  
MCD10089 Rev. 1.1, 8-Oct-08  
Page 8 of 9  
www.power-one.com  
QKS48T21120 DC-DC Bus Converter Data Sheet  
Quarter-Brick with 48VDC Input; 12VDC @ 21A Output  
Converter Part Numbering Ordering Information  
Series  
# Out  
Vin nom.  
I/O type  
Io  
Vo  
(nom. X 10)  
120  
-
On/Off Height  
logic  
Pin  
length options  
A, B, C  
Special  
QK  
1/4-  
Brick,  
S
48  
T
21  
ADC  
-
P, N  
C
0
Single  
output  
35 – 75Vdc  
Thru-hole  
VDC  
See table below  
Features & Options1  
Descriptions:  
Suffix code:  
Remote ON/OFF  
Positive logic  
Negative logic  
0.50” nom. (fixed value, no alternative height)  
0.18” (standard model length)  
0.145”  
-Pxxx  
-Nxxx  
-xCxx  
-xxAx  
-xxBx  
-xxCx  
-xxx0  
Unit Height  
Pin Length  
0.110”  
Special Options 1  
None (standard model, no special options)  
Latched Thermal Shutdown Protection  
Customer-specific models  
-xxxS1  
-xxxS#  
RoHS  
Add to Part Number  
RoHS lead solder exemption  
RoHS compliant for all six substances  
No RoHS character required.  
Add "G" as the last character of the part number.  
Example:  
Standard QKS with negative logic & 0.145 pin length; the resulting part number is QKS48T2112–NCB0  
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical  
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written  
consent of the respective divisional president of Power-One, Inc.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on  
the date manufactured. Specifications are subject to change without notice.  
MCD10089 Rev. 1.1, 8-Oct-08  
Page 9 of 9  
www.power-one.com  

相关型号:

QKS48T21120-PCA0G

DC-DC Regulated Power Supply Module, 1 Output, 252W, Hybrid, ROHS COMPLIANT PACKAGE-5
BEL

QKS48T21120-PCAS#

DC-DC Regulated Power Supply Module, 1 Output, 252W, Hybrid, PACKAGE-5
BEL

QKS48T21120-PCAS1G

DC-DC Regulated Power Supply Module, 1 Output, 252W, Hybrid, ROHS COMPLIANT PACKAGE-5
BEL

QKS48T21120-PCB0

DC-DC Regulated Power Supply Module, 1 Output, 252W, Hybrid, PACKAGE-5
BEL

QKS48T21120-PCB0G

DC-DC Regulated Power Supply Module, 1 Output, 252W, Hybrid, ROHS COMPLIANT PACKAGE-5
BEL

QKS48T21120-PCBS#

DC-DC Regulated Power Supply Module, 1 Output, 252W, Hybrid, PACKAGE-5
BEL

QKS48T21120-PCBS#G

DC-DC Regulated Power Supply Module, 1 Output, 252W, Hybrid, ROHS COMPLIANT PACKAGE-5
BEL
BEL

QKS48T21120-PCC0G

DC-DC Regulated Power Supply Module, 1 Output, 252W, Hybrid, ROHS COMPLIANT PACKAGE-5
BEL

QKS48T21120-PCCS#

DC-DC Regulated Power Supply Module, 1 Output, 252W, Hybrid, PACKAGE-5
BEL

QKS48T21120-PCCS#G

DC-DC Regulated Power Supply Module, 1 Output, 252W, Hybrid, ROHS COMPLIANT PACKAGE-5
BEL

QKS48T21120-PCCS1

DC-DC Regulated Power Supply Module, 1 Output, 252W, Hybrid, PACKAGE-5
BEL