TES113ZD-AN8 [BEL]

DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid;
TES113ZD-AN8
型号: TES113ZD-AN8
厂家: BEL FUSE INC.    BEL FUSE INC.
描述:

DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid

文件: 总3页 (文件大小:180K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
TES SERIES - 150 WATT  
DESCRIPTION  
FEATURES  
• Planar Magnetics  
• Low Voltage Outputs  
• 1500V Isolation  
• 45A “3/4 Brick”  
• Very High Efficiency  
• Open-Frame Packaging  
• 100°C Baseplate  
Operation  
TES single output DC/DC converters provide up to 150  
watts of output power at up to 45 Amperes of output  
current in an industry-standard “3/4 brick” package. The  
TES converters feature open-frame packaging, along with  
planar magnetics and a high efficiency topology, to  
provide maximum useable power density. The TES  
converters use 100% surface-mount construction and are  
fully compatible with production board washing  
processes.  
• Synchronous Rectification  
TECHNICAL SPECIFICATIONS  
Input  
Voltage Range  
48 VDC Nominal  
36 - 72 VDC  
Efficiency vs. Load (48V Input)  
Output  
95  
90  
85  
80  
75  
70  
65  
60  
55  
Setpoint Accuracy  
±1%  
Line Regulation V Min. - V Max., I  
Rated  
0.2% V  
in  
in  
out  
out  
Load Regulation I  
Min. - I  
Max., V Nom.  
0.5% V  
out  
out  
in  
out  
TES150ZE-A  
Remote Sense Headroom  
0.5 VDC  
EFF. (36v)  
EFF. (48v)  
EFF. (75v)  
Minimum Output Current  
10 % I  
Rated  
out  
Dynamic Regulation, Loadstep  
Pk Deviation  
25% I  
out  
out  
4% V  
Settling Time  
Voltage Trim Range  
Current Limit Type  
500 m s  
±10%  
Latch  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
LOAD %  
Current Limit Threshold Range, % of I  
Rated  
Rated  
110 - 140%  
out  
out  
Short Circuit Threshold Range, % of I  
200%  
General  
OVP Trip Range  
115 - 140% V  
Nom.  
out  
out  
Turn-On Time  
Remote Shutdown  
Remote Shutdown Reference  
10 ms  
Positive Logic  
Negative  
UVP Trip Range  
OVP/UVP Type  
70 - 90% V  
Nom.  
Latch  
V
in  
Switching Frequency 5V  
/ 3.3V & 2.5V  
300 kHz / 200 kHz  
out  
out  
Isolation  
Input - Output  
Input - Case  
Output - Case  
Temperature Coefficient  
Case Temperature  
Operating Range  
Storage Range  
Thermal Shutdown Range  
1500 VDC  
1050 VDC  
500 VDC  
Notes  
MTBF predictions may vary slightly from model to model.  
±0.02%/°C  
Specifications typically at 25°C, normal line, and full load, unless  
otherwise stated.  
-40 To +100°C  
-40 To +125°C  
105 to 115°C  
5 g, 10 - 55 Hz  
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with  
commercial wave-soldering equipment.  
Vibration, 3 Axes, 5 Min Each  
6
MTBF(Bellcore TR-NWT-000332)  
Safety  
Weight (Approx.)  
1.0 X 10 hrs  
Safety: Agency approvals may vary from model to model. Please  
consult factory for specific model information.  
UL, cUL, TUV  
3.3 oz  
REV. DEC 20, 2002  
1
TES SERIES - 150 WATT  
INPUT VOLTAGE  
(VOLTS)  
INPUT VOLTAGE  
RANGE (VOLTS)  
MAXIMUM INPUT  
CURRENT (AMPS)*  
OUTPUT  
VOLTAGE (VOLTS)  
RATED OUTPUT  
CURRENT (AMPS)  
RIPPLE & NOISE  
pk-pk (mV)  
TYPICAL  
EFFICIENCY**  
MODEL  
TES113ZD-A  
TES150ZE-A  
48  
48  
36-72  
36-72  
4.0  
5.1  
2.5  
3.3  
45  
45  
100  
100  
80%  
83%  
NOTES:  
*
Maximum input current at minimum input voltage, maximum rated output power.  
** At nominal V , rated output.  
in  
Thermal Impedance  
Natural Convection  
100 LFM  
200 LFM  
300 LFM  
400 LFM  
5.7 °C/W  
3.9 °C/W  
2.6 °C/W  
1.9 °C/W  
1.7 °C/W  
MECHANICAL DRAWING  
Note:  
Thermal impedance data is dependent on  
many environmental factors. The exact  
thermal performance should be validated  
for specific application.  
Pin  
Function  
1
-V  
in  
2
3
Enable  
Case  
4
+V  
in  
5
6
CN2 (opt.)  
CN1 (opt.)  
7
8
9
+V  
out  
+V  
out  
-V  
out  
10  
11  
12  
13  
-V  
out  
-Sense  
Trim  
+Sense  
Tolerances  
Inches:  
.XX ± 0.020  
.XXX ± 0.010  
(Millimeters)  
.X ± 0.5  
.XX ± 0.25  
Pin:  
± 0.002  
± 0.05  
(Dimensions as listed unless otherwise specified.)  
REV. DEC 20, 2002  
2
OPTIONS  
This page is offered as a reference. Consult factory for actual availability of options. When ordering  
equipment options, use the following suffix information. Select preferred option(s) and add the suffix to the  
model number. Ordering option examples are located below the options table.  
OPTION  
Negative Logic  
SUFFIX  
APPLICABLE SERIES  
REMARKS  
N
HAS, HBD, HBS, HES, HLS, HLD, LES,  
QBS, QES, QLS, TES, TQD  
TTL "Low" Turns Module ON  
TTL "High" Turns Module OFF  
Lucent-Compatible Trim  
T
HAS, HBD, HBS, HES, HLS, QBS, QES,  
QLS  
Trim  
1
2
3
IAS, LES  
Enable  
IAD, IAS, LES, SMS  
IAS, LES  
Trim and Enable  
Pin Length and Heatsink Options  
0.110" (2.8mm) Pin Length  
Standard Pin Length is 0.180" (4.6mm)  
8
9
All Leaded Models  
All Leaded Models  
0.150" (3.8mm) Pin Length  
0.24" (6.1mm) Horizontal Heatsink  
1H  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
Includes Thermal Pad  
Includes Thermal Pad  
Includes Thermal Pad  
Includes Thermal Pad  
Includes Thermal Pad  
Includes Thermal Pad  
0.24" (6.1mm) Vertical Heatsink  
0.45" (11.4mm) Horizontal Heatsink  
0.45" (11.4mm) Vertical Heatsink  
0.95" (24.1mm) Horizontal Heatsink  
0.95" (24.1mm) Vertical Heatsink  
1V  
2H  
2V  
3H  
3V  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks  
(Except HLS, HLD, QLS, TLD, and TKD Packages)  
Example Options:  
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95” vertical heatsink.  
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.  
QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110” pin length.  
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,  
equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional President  
of Power-One, Inc.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date  
manufactured. Specifications are subject to change without notice.  
REV. DEC 18, 2002  
3

相关型号:

TES113ZD-AN81H

DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid
BEL

TES113ZD-AN81V

DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid
BEL

TES113ZD-AN82V

DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid
BEL

TES113ZD-AN83H

DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid
BEL

TES113ZD-AN83V

DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid
BEL

TES113ZD-AN9

DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid
BEL

TES113ZD-AN91H

DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid
BEL

TES113ZD-AN92H

DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid
BEL

TES113ZD-AN92V

DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid
BEL

TES113ZD-AN93H

DC-DC Regulated Power Supply Module, 1 Output, 150W, Hybrid
BEL

TES12410V

DC/DC Converters
TRACOPOWER

TES12411

DC/DC Converters
TRACOPOWER