TQD080ZE2.0-AN [BEL]
DC-DC Regulated Power Supply Module, 2 Output, 100W, Hybrid;![TQD080ZE2.0-AN](http://pdffile.icpdf.com/pdf2/p00243/img/icpdf/TQD100ZGE-AN_1474726_icpdf.jpg)
型号: | TQD080ZE2.0-AN |
厂家: | ![]() |
描述: | DC-DC Regulated Power Supply Module, 2 Output, 100W, Hybrid |
文件: | 总3页 (文件大小:89K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
TQD DC/DC Series Data Sheet
Dual Output, 100 Watts
Features
• Independent dual outputs
• Flexible load sharing
• High efficiency
• Open-frame design
• Planar magnetics
• Independent trim for each output
• Synchronous rectification
• 1500V isolation
• 100°C baseplate operation
Description
The TQD DC/DC converters are high power, dual output, fully-isolated converters that feature high efficiency, 1500
VDC isolation, and open-frame packaging. The TQD family allows board designers to deliver any combination of
power from either output, up to each model’s maximum rating. The TQD Series is available in 5V/3.3V or 3.3V/2.5V
combinations. The TQD uses planar magnetics and has an MTBF of over a million hours.
Technical Specifications
Input
Voltage range
5 VDC nominal
12 VDC nominal
Reflected ripple
18 - 36 VDC
36 - 72 VDC
50 mA
Input Reverse Voltage Protection
Shunt Diode
Efficiency vs. Load (48V Input)
Output
90
85
80
75
70
65
60
55
Setpoint Accuracy
1%
Line Regulation V Min. - V Max., I
Rated, Output 1
0.2% V
in
out
in
Min. - I
out
Max., V Nom., Output 1
out
Load Regulation I
0.3% V
out
out
in
Minimum Output Current, Each Output
Dynamic Regulation, Loadstep
Pk Deviation
10 % I
Rated
out
25% I
4% V
out
out
Settling Time
Voltage Trim Range
Power Limit Threshold Range, % of I
OVP Trip Range
UVP Trip Range
500 m s
10%
TQD085ZED
TQD100ZGE
Rated
110 - 130%
Nom.
70 - 90%
out
115 - 140% V
out
General
10
20
30
40
50
60
70
80
90
100
LOAD %
Turn-On Time
20 ms
Positive Logic
250 kHz
Remote Shutdown
Switching Frequency
Isolation
Input - Output
Input - Case
Output - Case
1500 VDC
1050 VDC
500 VDC
Notes
MTBF predictions may vary slightly from model to model.
Temperature Coefficient
Case Temperature
Operating Range
Storage Range
0.03 %/°C
†
-40 To +100°C
-40 To +125°C
105 To 115°C
95%
Specifications typically at 25°C, normal line, and full load, unless
otherwise stated.
Thermal Shutdown Range
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
†
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
5 g
Units are water-washable and fully compatible with commercial spray or
immersion post wave-solder washing equipment.
6
MTBF (Bellcore TR-NWT-000332)
Safety
1.2 X 10 hrs
UL, cUL, TUV
3.8 oz
Weight (Approx.)
REV. AUG 11, 2003
Page 1 of 3
TQD DC/DC Series Data Sheet
Dual Output, 100 Watts
Model Selection
INPUT VOLTAGE
INPUT VOLTAGE
RANGE (VOLTS)
MAXIMUM INPUT
CURRENT (AMPS)*
OUTPUT
VOLTAGE (VOLTS)
RATED OUTPUT
CURRENT (AMPS)
RIPPLE & NOISE
pk-pk (mV)
TYPICAL
EFFICIENCY**
MODEL
(VOLTS)
TQD080ZE2.0-A
TQD085ZED-A
TQD100ZGE-A
48
48
48
36-72
36-72
36-72
1.9
2.5
3.7
3.3/2.0
3.3/2.5
5.0/3.3
15/15
20/25
20/25
100/75
100/75
100/75
80%
82%
83%
NOTES:
*
Maximum input current at minimum input voltage, maximum rated output power.
** At nominal V , rated output.
in
Current can be drawn from either output to its maximum value, or from both outputs.
Mechanical Drawing
Pin
Function
Tolerances
(Millimeters)
Thermal Impedance
Natural Convection
100 LFM
200 LFM
300 LFM
400 LFM
1
-V
in
Enable
Case
Inches:
.XX
.XXX 0.010
5.7 °C/W
3.9 °C/W
2.6 °C/W
1.9 °C/W
1.7 °C/W
2
3
4
0.020
.X 0.5
.XX 0.25
+V
in
Pin:
0.002
5
+V
out1
0.05
6
7
8
9
+ Sense 1
Trim 1
- Sense 1
(Dimensions as listed unless
otherwise specified.)
Note:
-V
Thermal impedance data is dependent
on many environmental factors. The
exact thermal performance should be
validated for specific application.
out1
10
-V
out2
11
12
13
14
- Sense 2
Trim 2
+ Sense 2
+ V
out2
REV. AUG 11, 2003
Page 2 of 3
OPTIONS
This page is offered as a reference. Consult factory for actual availability of options. When ordering
equipment options, use the following suffix information. Select preferred option(s) and add the suffix to the
model number. Ordering option examples are located below the options table.
OPTION
Negative Logic
SUFFIX
APPLICABLE SERIES
REMARKS
N
HAS, HBD, HBS, HES, HLS, HLD, LES,
QBS, QES, QLS, TES, TQD
TTL "Low" Turns Module ON
TTL "High" Turns Module OFF
Lucent-Compatible Trim
T
HAS, HBD, HBS, HES, HLS, QBS, QES,
QLS
Trim
1
2
3
IAS, LES
Enable
IAD, IAS, LES, SMS
IAS, LES
Trim and Enable
Pin Length and Heatsink Options
0.110" (2.8mm) Pin Length
Standard Pin Length is 0.180" (4.6mm)
8
9
All Leaded Models
All Leaded Models
0.150" (3.8mm) Pin Length
0.24" (6.1mm) Horizontal Heatsink
1H
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
Includes Thermal Pad
0.24" (6.1mm) Vertical Heatsink
0.45" (11.4mm) Horizontal Heatsink
0.45" (11.4mm) Vertical Heatsink
0.95" (24.1mm) Horizontal Heatsink
0.95" (24.1mm) Vertical Heatsink
1V
2H
2V
3H
3V
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
All 1/4-Bricks, 1/2-Bricks, 3/4-Bricks, Full-Bricks
(Except HLS, HLD, QLS, TLD, and TKD Packages)
Example Options:
HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent-compatible trim, and 0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent-compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of
Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.
REV. AUG 11, 2003
Page 3 of 3
相关型号:
©2020 ICPDF网 联系我们和版权申明